Refine
Year of publication
- 2017 (76) (remove)
Document Type
- Conference Proceeding (36)
- Article (reviewed) (17)
- Letter to Editor (6)
- Article (unreviewed) (6)
- Contribution to a Periodical (4)
- Book (3)
- Part of a Book (2)
- Patent (1)
- Report (1)
Conference Type
- Konferenzartikel (21)
- Konferenz-Abstract (10)
- Sonstiges (3)
- Konferenz-Poster (2)
Has Fulltext
- no (76) (remove)
Is part of the Bibliography
- yes (76)
Keywords
- CST (7)
- HF-Ablation (7)
- CRT (5)
- Götz von Berlichingen (3)
- RoboCup (3)
- IVD (2)
- Aktivierung (1)
- Anti-Windup-Maßnahmen (1)
- Beamforming (1)
- Beobachter (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (76) (remove)
Open Access
- Closed Access (35)
- Open Access (29)
- Bronze (3)
- Closed (3)
Since their dawning, space communications have been among the strongest driving applications for the development of error correcting codes. Indeed, space-to-Earth telemetry (TM) links have extensively exploited advanced coding schemes, from convolutional codes to Reed-Solomon codes (also in concatenated form) and, more recently, from turbo codes to low-density parity-check (LDPC) codes. The efficiency of these schemes has been extensively proved in several papers and reports. The situation is a bit different for Earth-to-space telecommand (TC) links. Space TCs must reliably convey control information as well as software patches from Earth control centers to scientific payload instruments and engineering equipment onboard (O/B) spacecraft. The success of a mission may be compromised because of an error corrupting a TC message: a detected error causing no execution or, even worse, an undetected error causing a wrong execution. This imposes strict constraints on the maximum acceptable detected and undetected error rates.
In this TDP we describe a new tool created for testing the strategy layer of our soccer playing agents. It is a complete 2D simulator that simulates the games based on the decisions of 22 agents. With this tool, debugging the decision and strategy layer of our agents is much more efficient than before due to various interaction methods and complete control over the simulation.
In the future, the tool could also serve as a measure to run simulations of game series much faster than with the 3D simulator. This way, the impact of different play strategies could be evaluated much faster than before.
In den vergangenen Jahren ist das technische Gas Schwefelhexafluorid (SF6) immer wieder Gegenstand von Diskussionen des Klimaschutzes und der technischen Notwendigkeit für den Betrieb von Schaltanlagen gewesen und wird dies wohl auch noch für längere Zeit bleiben. Das Gas, welches sich aus einem Schwefelatom und sechs Fluoratomen zusammensetzt, wird seit Ende der sechziger 1960er Jahre in Schaltanlagen der Mittel- und Hochspannung eingesetzt. So günstig dessen Eigenschaften im technischen Einsatz auch sind, so klimaschädlich ist es beim Entweichen in die Atmosphäre. SF6 ist das Klimagas mit dem größten bekannten Treibhauspotenzial, es weist ein CO2-Äquivalent (GWP) von 23.900 und eine atmosphärische Lebensdauer von ca. 3.200 Jahren auf. Neben nur wenig verbliebenen Anwendungen in Industrie, Militär und Medizin kommt es heute hauptsächlich bei der elektrischen Energieversorgung als Isolier- und Lichtbogenlöschgas in Schaltanlagen von Übertragungs- und Verteilnetzen zum Einsatz. Grund genug die technische Notwendigkeit, mögliche Alternativen und Konsequenzen drohender Verbote zu diskutieren. In diesem Artikel werden zunächst die Grundlagen moderner SF6- Hochspannungsschaltanlagen vorgestellt, die Klimabelastung durch entweichendes SF6 evaluiert, ein Überblick über den Stand der Forschung gegeben und mögliche Konsequenzen eines Verbotes von Schwefelhexafluorid in der Energieversorgung diskutiert.
In the past two decades much has been published on whiplash injury, yet both the confusion regarding the condition, and the medicolegal discussion about it have increased. In this paper, functional imaging research results are summarized using MRIcroGL3D visualization software and assembled in an image comprising regions of cerebral activation and deactivation.
Electrolyte-Gated Field-Effect Transistors Based on Oxide Semiconductors: Fabrication and Modeling
(2017)
Gelingt den Studienanfängern eine strukturierte Ergebnissicherung der Lehrveranstaltungen? Oder sind viele allein schon mit einem vollständigen Mitschrieb überfordert? Laufen aktivierende Methoden, Medienwechsel und der Wunsch nach strukturierter Sicherung der Inhalte des Lehrgesprächs teilweise sogar auseinander? Immer mehr Studierende (möchten) auch per Tablet mitschreiben. Wie könnte man in der Lehre auf diese Aspekte stärker eingehen?
Es wird ein praktischer Ansatz gezeigt, Mathematik-Vorlesungen über ein Tablet-basiertes Mitmach-Skript zu gestalten. Dieses dient als Schrittmacher zwischen Input- und Verarbeitungsphasen und unterstützt die strukturierte Verschriftlichung, indem es Vorteile von Tafel, PPT und klassischem Skript vereint. Traditionelle Methoden werden mit technologischen Möglichkeiten kombiniert, um die angesprochenen Herausforderungen bewusster im Lehrstil zu berücksichtigen. Verbindungen zu Virtual Classroom und Video-gestützter Lehre werden aufgezeigt.
Gaps in basic math knowledge are among the biggest obstacles to a successful start in university. Students starting their studies in STEM disciplines display significant diversity, “math anxiety” is a widespread phenomenon, and the transition to a self-determined way of studying presents a huge challenge. Universities offer support measures such as preparatory courses. Over the years, Offenburg University realized that with increased diversity, traditional ways of teaching in front of the class have become inefficient. The majority of the students remained inactive and just listened to the teachers’ explanations and the few active participants’ answers.
Since 2013 our new course concept fosters a shift from teaching to active learning on a large scale, involving several hundred participants of our on-site preparatory math courses. This switch to broad active practicing, however, must go hand in hand with providing individual support for an increasingly diverse student body. Meanwhile students bring along their mobile devices, and the training App TeachMatics serves as a facilitator. The course concept has been very well received by both students and teachers.
This paper describes the Sweaty II humanoid adult size robot trying to qualify for the RoboCup 2017 adult size humanoid competition. Sweaty came 2nd in RoboCup 2016 adult size league. The paper describes the main characteristics of Sweaty that made this success possible, and improvements that have been made or are planned to be implemented for RoboCup 2017.
In this paper we show that a model-free approach to learn behaviors in joint space can be successfully used to utilize toes of a humanoid robot. Keeping the approach model-free makes it applicable to any kind of humanoid robot, or robot in general. Here we focus on the benefit on robots with toes which is otherwise more difficult to exploit. The task has been to learn different kick behaviors on simulated Nao robots with toes in the RoboCup 3D soccer simulator. As a result, the robot learned to step on its toe for a kick that performs 30% better than learning the same kick without toes.
Background: R-wave synchronised atrial pacing is an effective temporary pacing
therapy in infants with postoperative junctional ectopic tachycardia. In the technique
currently used, adverse short or long intervals between atrial pacing and ventricular
sensing (AP–VS) may be observed during routine clinical practice.
Objectives: The aim of the study was to analyse outcomes of R-wave synchronised
atrial pacing and the relationship between maximum tracking rates and AP–VS
intervals.
Methods: Calculated AP–VS intervals were compared with those predicted by experienced
pediatric cardiologist.
Results: A maximum tracking rate (MTR) set 10 bpm higher than the heart rate (HR)
may result in undesirable short AP–VS intervals (minimum 83 ms). A MTR set 20 bpm
above the HR is the hemodynamically better choice (minimum 96 ms). Effects of either
setting on the AP–VS interval could not be predicted by experienced observers. In our
newly proposed technique the AP–VS interval approaches 95 ms for HR > 210 bpm
and 130 ms for HR < 130 bpm. The progression is linear and decreases strictly
(− 0.4 ms/bpm) between the two extreme levels.
Conclusions: Adjusting the AP–VS interval in the currently used technique is complex
and may imply unfavorable pacemaker settings. A new pacemaker design is advisable
to allow direct control of the AP–VS interval.
Cellular phone antennas are generally designed to have radiation patterns that are as omnidirectional as possible. Omnidirectional antennas allow a phone’s radio to work well for many orientations of the phone with respect to the cellular base station. Recent studies, however, are generating uncertainty about the health effects of prolonged exposure to electromagnetic (EM) radiation from cellular phones. In this paper, an antenna array is designed primarily to minimize users’ exposure to EM radiation. The antenna comprises a beamforming 4 by 3 array of microstrip patch antennas that is controlled by an accelerometer-only inertial navigation system. The proposed design reduces radiated power directed toward the user to below 10% of the total in the worst case.
Background: Cardiac resynchronization therapy (CRT) with biventricular (BV) pacing is an established therapy for heart failure (HF) patients (P) with sinus rhythm, reduced left ventricular (LV) ejection fraction (EF) and electrical ventricular desynchronization. The aim of the study was to evaluate electrical interventricular delay (IVD) and left ventricular delay (LVD) in right ventricular (RV) pacemaker pacing before upgrading to CRT BV pacing.
Methods: HF P (n=11, age 69.0 ± 7.9 years, 1 female, 10 males) with DDD pacemaker (n=10), DDD defibrillator (n=1), RV pacing, New York Heart Association (NYHA) class 3.0 ± 0.2 and 24.5 ± 4.9 % LVEF were measured by surface ECG and transesophageal bipolar LV ECG before upgrading to CRT defibrillator (n=8) and CRT pacemaker (n=3). IVD was measured between onset of QRS in the surface ECG and onset of LV signal in the transesophageal ECG. LVD was measured between onset and offset of LV signal in the transesophageal ECG. CRT atrioventricular (AV) and BV pacing delay were optimized by impedance cardiography.
Results: Interventricular and intraventricular desynchronization in RV pacemaker pacing were 228.2 ± 44.8 ms QRS duration, 86.5 ± 32.8ms IVD, 94.4 ± 23.8ms LVD, 2.6 ± 0.8 QRS-IVD-ratio with correlation between IVD and QRS-IVD-ratio (r=-0.668 P=0.0248) and 2.3 ± 0.7 QRS-LVD-ratio. The LVEF-IVD-ratio was 0.3 ± 0.1 with correlation between IVD and LVEF-IVD-ratio (r=-0.8063 P=0.00272) and with correlation between QRS duration and LVEF-IVD-ratio (r=-0.7251 P=0.01157). Optimal sensing and pacing AV delay were 128.3 ± 24.8 ms AV delay after atrial sensing (n=6) and 173.3 ± 40.4 ms AV delay after atrial pacing (n=3). Optimal BV pacing delay was -4.3 ± 11.3 ms between LV and RV pacing (n=7). During 30.4 ± 29.6 month CRT follow-up, the NYHA class improved from 3.1 ± 0.2 to 2.2 ± 0.3.
Conclusions: Transesophageal electrical IVD and LVD in RV pacemaker pacing may be additional useful ventricular desynchronization parameters to improve P selection for upgrading RV pacemaker pacing to CRT BV pacing.
Background: The electrical field (E-field) of the biventricular (BV) stimulation is important for the success of cardiac resynchronization therapy (CRT) in patients with cardiac insufficiency and widened QRS complex. The 3D modeling allows the simulation of CRT and high frequency (HF) ablation.
Purpose: The aim of the study was to model different pacing and ablation electrodes and to integrate them into a heart model for the static and dynamic simulation of atrial and BV stimulation and high frequency (HF) ablation in atrial fibrillation (AF).
Methods: The modeling and simulation was carried out using the electromagnetic simulation software CST (CST Darmstadt). Five multipolar left ventricular (LV) electrodes, one epicardial LV electrode, four bipolar right atrial (RA) electrodes, two right ventricular (RV) electrodes and one HF ablation catheter were modeled. Selected electrodes were integrated into the Offenburg heart rhythm model for the electrical field simulation. The simulation of an AV node ablation at CRT was performed with RA, RV and LV electrodes and integrated ablation catheter with an 8 mm gold tip.
Results: The right atrial stimulation was performed with an amplitude of 1.5 V with a pulse width of 0.5. The far-field potentials generated by the atrial stimulation were perceived by the right and left ventricular electrode. The far-field potential at a distance of 1 mm from the right ventricular electrode tip was 36.1 mV. The far-field potential at a distance of 1 mm from the left ventricular electrode tip was measured with 37.1 mV. The RV and LV stimulation were performed simultaneously at amplitude of 3 V at the LV electrode and 1 V at the RV electrode with a pulse width of 0.5 ms each. The far-field potentials generated by the BV stimulations could be perceived by the RA electrode. The far-field potential at the RA electrode tip was 32.86 mV. AV node ablation was simulated with an applied power of 5 W at 420 kHz and 10 W at 500 kHz at the distal 8 mm ablation electrode.
Conclusions: Virtual heart and electrode models as well as the simulations of electrical fields and temperature profiles allow the static and dynamic simulation of atrial synchronous BV stimulation and HF ablation at AF. The 3D simulation of the electrical field and temperature profile may be used to optimize the CRT and AF ablation.
Hintergrund: Das elektrische interventrikuläre Delay (IVD) ist bei Patienten (P) mit Herzinsuffizienz (HF), reduzierter linksventrikulärer (LV) Funktion und verbreitertem QRS Komplex von Bedeutung für den Erfolg der kardialen Resynchronisationstherapie (CRT). Die transösophageale LV Elektrokardiographie (EKG) ermöglicht die Bestimmung des elektrischen IVD und linksventrikulären Delays (LVD). Das Ziel der Studie besteht in der Untersuchung des transösophagealen elektrischen IVD, LVD und deren Verhältnis zur QRS Dauer bei rechtsventrikulärer (RV) Stimulation vor Aufrüstung auf eine biventrikuläre (BV) Stimulation.
Methoden: Bei 11 HF P (Alter 69,0 ± 7,9 Jahre; 10 Männer und 1 Frau) mit DDD Schrittmacher (n=10), DDD Defibrillator (n=1) und RV Stimulation, New York Heart Association (NYHA) Klasse 3,0 ± 0,2, LV Ejektionsfraktion 24,5 ± 4,9 % und QRS-Dauer 228,2 ± 44,8 ms wurden das elektrische IVD als Intervall zwischen Beginn des QRS-Komplexes im Oberflächen EKG und Beginn des LV Signals im transösophagealen LV EKG und das elektrische LVD als Intervall zwischen Beginn und Ende des LV Signals im transösophagealen LV EKG präoperativ vor Aufrüstung auf CRT Defibrillator (n=8) und CRT Schrittmacher (n=3) bestimmt. Der Anstieg des arteriellen Pulse Pressure (PP) wurde zwischen RV Stimulation und transösophagealer LV Stimulation mit unterschiedlichem AV-Delay (n=5) vor Aufrüstung von RV auf BV Stimulation getestet.
Ergebnisse: Bei RV Stimulation betrugen IVD 86,54 ± 32,80 ms, LVD 94,45 ± 23,80 ms, QRS-IVD-Verhältnis 2,63 ± 0,81 mit negativer Korrelation zwischen IVD und QRS-IVD-Verhältnis (r=-0,668 P=0,0248) (Fig.) und QRS-LVD-Verhältnis 2,33 ± 0,73. Vorhofsynchrone ventrikuläre Stimulation führte zu 63,6 ± 27,7 mmHg PP bei RV Stimulation und 80,6 ± 38,5 mmHg PP bei LV Stimulation und der PP erhöhte sich bei LV Stimulation mit optimalem AV Delay um 17 ± 11,2 mmHg gegenüber RV Stimulation (P<0,001). Nach Aufrüstung von RV Stimulation auf BV Stimulation verbesserten sich die NYHA Klasse von 3,1 ± 0,2 auf 2,2 ± 0,3 während 30,4 ± 29,6 Monaten CRT.
Schlussfolgerungen: Das transösophageale LV EKG ermöglicht die Bestimmung des elektrischen IVD und LVD bei RV Stimulation zur Evaluierung der interventrikulären und linksventrikulären elektrischen Desynchronisation. IVD, LVD und deren Verhältnis zur QRS Dauer können möglicherweise zur Vorhersage einer CRT Response vor Aufrüstung von RV auf BV Stimulation genutzt werden.