Refine
Year of publication
- 2014 (192) (remove)
Document Type
- Conference Proceeding (76)
- Article (unreviewed) (43)
- Article (reviewed) (32)
- Part of a Book (15)
- Book (14)
- Patent (8)
- Contribution to a Periodical (1)
- Other (1)
- Periodical Part (1)
- Report (1)
Conference Type
- Konferenzartikel (57)
- Konferenz-Abstract (11)
- Konferenz-Poster (3)
- Konferenzband (3)
- Sonstiges (2)
Has Fulltext
- no (192) (remove)
Keywords
- Kommunikation (5)
- Intelligentes Stromnetz (4)
- Lithiumbatterie (4)
- Produktentwicklung (4)
- Produktion (4)
- E-Learning (3)
- Elektrolyt (3)
- Herzkrankheit (3)
- Management (3)
- Mathematik (3)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (102)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (44)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (28)
- Fakultät Wirtschaft (W) (24)
- INES - Institut für nachhaltige Energiesysteme (15)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (6)
- IUAS - Institute for Unmanned Aerial Systems (4)
- Zentrale Einrichtungen (4)
- POIM - Peter Osypka Institute of Medical Engineering (2)
- Rektorat/Verwaltung (1)
Open Access
- Closed Access (49)
- Open Access (49)
- Closed (25)
- Bronze (13)
This paper investigates the maximum torque capability and torque ripple reduction using the asymmetric stator teeth for interior permanence magnet (IPM) synchronous machines. Traditional electric machines have the identical width for all stator teeth and the winding function is fixed. Using different widths for different stator teeth changes the winding function, therefore, the torque ripple components. The mathematical modeling of interior permanent magnet (IPM) synchronous machine torque ripple and finite element analysis simulation results for the characteristic properties of electric machines are presented. Compared with a similar rating IPM machine, certain combinations of the teeth widths can reduce the torque ripple by 80% with less than 4% average torque decline.
A recognizable division appears between students with a comprehensive knowledge of the Web and those that are less certain about its resources. This is where, the teaching innovation Web Mentoring: Peer-to-Peer has been developed to help the students to cope better with the demands of media education. Furthermore, this presents the opportunity for master’s degree students to begin mentoring undergraduate students. Mentoring sessions have already been carried out successfully in the previous two semesters and are being presented, evaluated and discussed.
Introduction: Despite lots of developments in the last years, radiofrequency ablation of rhythm diseases is a safe but still complex procedure that requires special experience and expertise of the physicians and biomedical engineers. Thus, there is a need of special trainings to become familiar with the different equipment and to explain several effects that can be observed during clinical routine.
Methods: The Offenburg University of Applied Sciences offers a biomedical engineering study path specialized in the fields of cardiology, electrophysiology and cardiac electronic implants. It`s Peter Osypka Institute for Pacing and Ablation provides teaching following the slogan “Learning by watching, touching and adjusting”. It conducts lots of trainings for students as well as young physicians interested in electrophysiology and radiofrequency ablation.
Results: In-vitro trainings will be provided using the Osypka HAT 200 and HAT300s, Stockert EPshuttle and SmartAblate system as well as the Boston EPT-1000XP and Maestro 3000 and the Radionics RFG-3E cardiac radio frequency ablation generators. All of them require different handling as well as special accessories like catheter connection cables or boxes and back plates. The participants will be trained in the setup of temperature, power and cut-off impedance dependent on different ablation catheters. Furthermore troubleshooting in hard- and software is part of the program. Performing procedures in pork or animal protein and using physiological saline solution to simulate the blood flow, they can study the influence of contact force and impedance on lesion geometry etc. and to avoid adverse effects like “plops”. Lots of catheter types are available: 4mm tip, 8mm standard and gold tip, open and closed irrigated tip ablation catheters of different companies. The experiments will be completed by measuring the lesion size dependent on the used catheter type and ablation settings.
Conclusion: In-vitro training in radiofrequency ablation is a challenge for biomedical engineering students and young physicians.
Pressure dynamics in metal-oxygen (metal-air) batteries: a case study on sodium superoxide cells
(2014)
Electrochemical reactions in metal–oxygen batteries come along with the consumption or release of gaseous oxygen. We present a novel methodology for investigating electrode reactions and transport phenomena in metal–oxygen batteries by measuring the pressure dynamics in an enclosed gas reservoir above the oxygen electrode. The methodology is exemplified by a room-temperature sodium–oxygen battery forming sodium superoxide (NaO2) in an electrolyte of diethylene glycol dimethyl ether (diglyme) and sodium trifluoromethanesulfonate (NaOSO2CF3, NaOTf). The experiments are supported by microkinetic simulations with a one-dimensional multiphysics continuum model. During galvanostatic cycling over 30 cycles, a constant oxygen consumption/release rate is observed upon discharge/charge. The number of transferred electrons per oxygen molecule is calculated to 1.01 ± 0.02 and 1.03 ± 0.02 for discharge and charge, respectively, confirming the nature of the oxygen reaction product as superoxide O2–. The same ratio is observed in cyclic voltammetry experiments with low scan rate (<1 mV/s). However, at higher scan rates, the ratio increases as a result of oxygen transport limitations in the electrolyte. We introduce electrochemical pressure impedance spectroscopy (EPIS) for simultaneously analyzing current, voltage, and pressure of electrochemical cells. Pressure recording significantly increases the sensitivity of impedance toward oxygen transport properties of the porous electrode systems. In addition, we report experimental data on the diffusion coefficient and solubility of oxygen in electrolyte solutions as important parameters for the microkinetic models.
Cardiac resynchronization therapy is an established therapy for heart failure patients with sinus rhythm, reduced left ventricular ejection fraction and prolongation of QRS duration. The aim of the study was to evaluate ventricular desynchronization with electrical interventricular delay (IVD) to left ventricular delay (LVD) ratio in atrial fibrillation heart failure patients. IVD and LVD were measured by transesophageal posterior left ventricular ECG recording. In atrial fibrillation heart failure patients with prolonged QRS duration, the mean IVD-to-LVD-ratio was 0.84 +/- 0.42 with a range from 0.17 to 2.2 IVD-to-LVD-ratio. IVD-to-LVD-ratio correlated with QRS duration. IVD-to-LVD-ratio may be a useful parameter to evaluate electrical ventricular desynchronization in atrial fibrillation heart failure patients.
Hintergrund: Das elektrische interventrikuläre Delay (IVD) und die Lage der linksventrikulären (LV) Elektrode zum Ort der spätesten LV Erregung sind bei Patienten (P) mit Herzinsuffizienz (HF), reduzierter LV Funktion und breiter QRS Dauer (QRSD) von Bedeutung für den Erfolg der kardialen Resynchronisationstherapie (CRT). Die LV Elektrokardiographie ermöglicht eine Abschätzung des elektrischen IVD. Ziel der Studie besteht in der nicht-invasiven Evaluierung des elektrischen IVD bei Patienten (P) mit Vorhofflimmern (AFib) mit und ohne CRT mit biventrikulärer (BV) Stimulation.
Methoden: Bei 49 HF P mit AFib (Alter 63,9 ± 10,8 Jahre; 43 Männer und 6 Frauen) mit New York Heart Association (NYHA) Klasse 2,9 ± 0,4, LV Ejektionsfraktion 26,03 ± 7,99 % und QRS-Dauer (QRSD) 143,69 ± 35,62 ms wurde das elektrische IVD als Intervall zwischen Beginn des QRS-Komplexes im Oberflächen EKG und Beginn des LV Signals im transösophagealen LV EKG bei 31 HF P mit AFib und bei 18 HF P mit AFib und CRT präoperativ bestimmt. Das fokussierte bipolare LV EKG wurde mittels Osypka TO Sonde mit halbkugelförmigen Elektroden in Höhe des maximalen LV Signals registriert.
Ergebnisse: Bei 31 HF P mit AFib betrugen QRSD 135,48 ± 38,78 ms, IVD 49,55 ± 26,38 ms, QRSD-IVD-Verhältnis 3,12 ± 1,11 und das IVD korrelierte mit der QRSD (r=0,75, P<0,001) und dem QRSD-IVD-Verhältnis (r=-0,67, P<0,001) (Fig.). Bei 18 HF P mit AFib und CRT Defibrillator betrugen QRSD 157,83 ± 24,38 ms, IVD 61,94 ± 26,88 ms, QRSD-IVD-Verhältnis 3,12 ± 1,89 und das IVD korrelierte mit der QRSD (r=0,47, P=0,049) und dem QRSD-IVD-Verhältnis (r=-0,73, P<0,001). Bei 72,2 % CRT Responder (R) (n=13) betrugen QRSD 158,15 ± 22,4 ms, IVD 64,23 ± 24,62 ms, QRSD-IVD-Verhältnis 2,82 ± 1,32 und das IVD korrelierte mit der QRSD (r=0,57, P=0,043) und dem QRSD-IVD-Verhältnis (r=-0,76, P=0,0024). Bei 27,8 % CRT Non-Responder (NR) (n=5) betrugen QRSD 157 ± 31,94 ms, IVD 56 ± 34,52 ms, QRSD-IVD-Verhältnis 3,88 ± 2,98 und das IVD korrelierte nicht mit der QRSD (r=0,33, P=0,591) und dem QRSD-IVD-Verhältnis (r=-0,732, P=0,159). Die CRT R verbesserten sich in der NYHA Klasse von 3 ± 0,2 auf 2,2 ± 0,3 (P<0,001) während 15,3 ± 13,1 Monaten BV Stimulation. Bei 15 CRT NR kam es zu keiner Verbesserung der NYHA Klasse von 3 auf 3,3 ± 0,97 (P=0,529) während 18,8 ± 20,7 Monaten BV Stimulation.
Schlussfolgerungen: Das transösophageale LV EKG ermöglicht bei HF-P mit AFib die nichtinvasive Messung des elektrischen IVD präoperativ vor CRT. IVD und QRSD-IVD-Verhältnis sind möglicherweise einfach anwendbare Parameter zur Vorhersage von CRT R und CRT NR bei P mit AFib.
Cardiac resynchronization therapy with atrioventricular and interventricular pacing delay optimized biventricular pacing is an established therapy for heart failure patients with sinus rhythm and reduced left ventricular ejection fraction. The aim of the study was to evaluate atrioventricular and interventricular pacing delay optimization in cardiac resynchroniza-tion therapy by transthoracic impedance cardiography in biventricular pacing with different left ventricular electrode po-sition. In biventricular pacing heart failure patients with lateral, posterolateral and anterolateral left ventricular electrode position, the mean optimal atrioventricular sening delay was 108.6 ± 20.3 ms and the mean optimal interventricular pac-ing delay -12.3 ± 25.9 ms. Transthoracic impedance cardiography may be a useful technique to optimize atrioventricular and interventricular pacing delay in biventricular pacing with different left ventricular electrode position.
The characteristic features and applications of linear and nonlinear guided elastic waves propagating along surfaces (2D) and wedges (1D) are discussed. Laser-based excitation, detection, or contact-free analysis of these guided waves with pump–probe methods are reviewed. Determination of material parameters by broadband surface acoustic waves (SAWs) and other applications in nondestructive evaluation (NDE) are considered. The realization of nonlinear SAWs in the form of solitary waves and as shock waves, used for the determination of the fracture strength, is described. The unique properties of dispersion-free wedge waves (WWs) propagating along homogeneous wedges and of dispersive wedge waves observed in the presence of wedge modifications such as tip truncation or coatings are outlined. Theoretical and experimental results on nonlinear wedge waves in isotropic and anisotropic solids are presented.
The process of establishing an industry standard for TRIZ has been initiated: VDI Guideline 4521 will cover TRIZ. Work is going on on the first part of the standard which will define and explain basic TRIZ vocabulary and notions. A first draft of a list of terms has been compiled by V. Souchkov and is currently being discussed at MATRIZ. The standardization committee consists of TRIZ specialists of various degrees together with TRIZ users from industry. It is working in close connection with MATRIZ. In parallel, translations for the elements of TRIZ terminology into several languages are being sought. According to schedule, work on the first part of the standard may be finished by July 2014 and may go into print by the end of the year.
Lithium–sulfur (Li/S) cells are promising candidates for a next generation of safe and cost-effective high energy density batteries for mobile and stationary applications. At present, most Li/S cells still suffer from relatively poor cyclability, capacity loss under moderate current densities and self-discharge. Furthermore, the underlying chemical mechanisms of the general discharge/charge behavior as well as Li/S-specific phenomena like the polysulfide shuttle are not yet fully understood. Here we present a thermodynamically consistent, fully reversible continuum model of a Li/S cell with simplified four-step electrochemistry, including a simple description of the polysulfide shuttle effect. The model is parameterized using experimental discharge curves obtained from literature and reproduces behavior at various current densities with fairly high accuracy. While being instructively simple, the presented model can still reproduce distinct macroscopic Li/S-cell features caused by the shuttle effect, e.g., seemingly infinite charging at low charge current densities, and suboptimal coulombic efficiency. The irreversible transport of active material from the cathode to the anode results in a voltage drop and capacity loss during cycling, which can also be observed experimentally.
WirelessHART protocol was specifically designed for real-time communication in the wireless sensor networks domain for industrial process automation requirements. Whereas the major purpose of WirelessHART is the read-out of sensors with moderate real-time requirements, an increasing demand for integration of actuator applications can be observed. Therefore, it must be verified that the WirelessHART protocol gives sufficient support to real-time industry requirements. As a result, the delay of especially burst and command messages from actuator and sensor nodes to the gateway and vice versa must be analyzed. In this paper, we implemented a WirelessHART network scenario in WirelessHART simulator in NS-2 [8], simulated and analyzed its time characteristics under ideal and noisy conditions. We evaluated the performance of the implementation in order to verify whether the requirements of industrial process and control can be met. This implementation offers an early alternative to expensive test beds for WirelessHART in real-time actuator applications.
Höchste Korrosionsschutzanforderungen sind für bestimmte technische Produkte insbesondere im Offshore Anwendungsbereich, nach ISO 20340, zwingend zu erfüllen, um deren Funktion und Betriebssicherheit dauerhaft gewährleisten zu können. Bis heute werden viele dieser Produkte am Ende ihrer Wertschöpfungskette nass überlackiert, mit einer kompletten Kunststoffhaut, der Korrosionsschutz-Lackschicht, überzogen. Diese Lackierung ist unter anderem deshalb erforderlich, weil es im klassischen Maschinenbau, insbesondere in der Antriebstechnik, viele mechanische Schnittstellen gibt, die vor der endgültigen Produktmontage quasi metallisch blank bleiben müssen, um den erforderlichen und definierten geometrischen Oberflächenzustand nach Form und Lage als Pass- und Fügefläche zu gewährleisten. Eine dieser mechanischen Schnittstellen sind Schraubenverbindungen. Mit dem derzeit gültigen Regelwerk ist die Berechnung einer Schraubenverbindung mit Lackschichten in den Trennfugen oder auf der Kopf- und Mutternauflagefläche nicht möglich, da lackierte Bauteile in der derzeit geltenden VDI-Richtlinie 2230 nicht berücksichtigt sind. Nach einem Praxisbericht anhand von Stellantrieben für Industriearmaturen über deren Umstellung von Nasslackierung des Gesamtproduktes auf Pulverbeschichtung von Einzelteilen wird die experimentelle Validierung der Betriebs- und Funktionssicherheit von Schraubenverbindungen mit lackierten Bauteilen vorgestellt. Daraus resultierend wurde im März 2014 an der Hochschule Offenburg ein Forschungsprojekt gestartet, dessen Ziel es ist für die oben genannte Problemstellung einen systematischen Lösungsansatz zu erarbeiten. Künftig soll es Entwicklungsingenieuren und Konstrukteuren bereits in der Phase von Entwicklung und Konstruktion möglich sein Schraubenverbindungen mit lackierten Bauteilen zuverlässig zu berechnen und auszulegen oder diese in der Prototypenphase zuverlässig zu testen. Die letzten beiden Abschnitte geben den Lösungsansatz und den aktuellen Stand der Forschung wider.
Since direct current high energy shock fulguration was initially performed in the mid 1980s, ablation of cardiac arrhythmias has come to widespread use. Today the most frequently used energy source for catheter ablation is radio frequency (RF). It was the German engineer Peter Osypka who made available the HAT 100 as the first simple commercial RF ablator.
Nevertheless, in the first years of ablation, physicians were effectively working in the dark. Until today with an increasing understanding of arrhythmia mechanisms, both at the atrial and ventricular levels, this curative technology has made tremendous progress. Now, due to crucial improvement of RF ablation generators, temperature and contact force sensor catheters in combination with non-flouroscopic electroanatomical mapping technologies, computerized temperature and impedance controlled radiofrequency catheter ablation can be used to cure all types of arrhythmias including atrial and ventricular fibrillation. For the latter, cooled ablation by saline solution irrigated catheters has been developed to a widely used standard method. This procedure resulting in pulmonary vein isolation requires transseptal puncture and is technically demanding. Nevertheless, it has shown to be more effective than antiarrhythmic drug therapy.
While earliest RF ablations were performed with non-steerable catheters, today are used steerable sensor catheters without or with external and internal cooling and tips of 4mm or 8mm length. Further innovations like integration of mapping and cardiac imaging give exact information of the number of pulmonary veins and branching patterns and help to correlate electrical signals with anatomical structures.
The magnetic navigation significantly improved the success rates and safety of catheter ablation. Thus, in most cases RF catheter ablation has developed in the treatment of supraventricular arrhythmias from an alternative approach to drug therapy into the first therapeutic choice providing low complication rates.
In future, robotic navigation will further simplify procedures and reduce radiation exposure of this curative approach.
Introduction: Radiofrequency ablation allows successful treatment of most supraventricular reentrant and focal tachycardias and an increasing number of ventricular tachycardias. Different catheter tips are used. While AV nodal reentrant tachycardias require catheters with a tip of 4mm length, an 8 mm tip electrodes will be used for atrial flutter. A pulmonary vein isolation will be performed using 4 mm irrigated tip electrodes to achieve larger and deeper lesions. The need of a tubing set and pump for saline transfusion is a disadvantage of this technique. Gold tip electrodes can alternatively be used to produce increases in lesion size. Aim of this study was to compare RF ablation catheters of exactly the same geometry with either platin-iridum or gold tip.
Methods: Gold provides an almost four-fold thermal conductivity compared with platinum-iridium. The Cerablate G flutter (Osypka AG, Rheinfelden-Herten) is a newly designed radiofrequency ablation catheter with an 8 mm gold tip. Its power delivery was compared with the Cerablate flutter of same geometry but platin-iridium tip. Therefore, in-vitro RF ablations were performed using pork meat in a 0.9% saline solution at 37°C temperature. A pulsed volume flow was generated using a pump to simulate the blood flow. Temperature controlled ablations of 60 seconds using 45, 55 and 65°C and a maximum of 70W RF power were performed.
Results: Using the Osypka HAT300smart ablator, cumulative power of 167, 474 and 672W was delivered with gold tip against 121, 227 and 310 W with platin-iridium tip. By the Stockert SmartAblate G4 ablator, 202, 546 and 1075W was delivered with gold tip against 117, 246 and 394W with platin-iridium using 45, 55 and 65°C temperature.
Conclusion: During in-vitro investigations, the gold tip electrodes allowed a in power delivery increase of 117 up to 173%. Thus, gold tips can be used to increase lesion depth and diameter without cooling equipment.
In addition to traditional methods in product development, the increasing availability of additive manufacturing AM technologies offer new opportunities in product development processes today. This contribution explores several ways in which AM can productively be used in education. New to this approach is amongst others that the students assemble and install the 3D-printers themselves. In two case studies is demonstrated how students in design education are able to autonomously research and realize technical possibilities and limitations of AM technologies, as well as economic constraints.