Background/Purpose
Several methods are used to evaluate the outcome of total hip arthroplasty (THA), however, their relationship at different time points after surgery is unclear. The purpose of this exploratory study was to investigate correlations between self-report function, performance-based tests (PBTs) and biomechanical parameters in patients 12 months after THA.
Methods
Eleven patients were included in this preliminary cross-sectional study. Hip disability and Osteoarthritis Outcome Score (HOOS) was completed for self-reported function. As PBTs, the Timed-up-and-Go test (TUG) and 30-Second-Chair-Stand test (30CST) were used. Biomechanical parameters were derived from analyses of hip strength, gait and balance. Potential correlations were calculated using Spearman correlation coefficient r.
Results
HOOS scores and parameters of PBTs showed moderate to strong correlations (0.3 < r < 0.7). Correlation analysis between HOOS scores and biomechanical parameters revealed moderate to strong correlations for hip strength whereas correlations with gait parameters and balance were rather weak (r < 0.3). Moderate to strong correlations were also found between parameters of hip strength and 30CST.
Conclusion
For THA outcome assessment 12 months after surgery, our first results indicate that self-report measures or PBTs could be used. Analysis of hip strength also appears to be reflected in HOOS and PBT parameters and may be considered as an adjunct. Given the weak correlations with gait and balance parameters, we suggest that gait analysis and balance testing should be performed in addition to PROMs and PBTs as they may provide supplementary information, especially for THA patients that are at risk for falls.
Da Perturbationen die Hauptursache für Stürze in der Ebene darstellen, befasst sich diese Studie mit der Erzeugung von Gangstörungen unter sicheren Laborbedingungen. Dies hat sich als nützliches Werkzeug im Bereich der Rehabilitation bewährt. Zunächst wurde ein Perturbationstest auf einem instrumentierten Laufband unter Verwendung von Matlab entwickelt. Anschließend wird dieser auf die Präzision und Wiederholbarkeit evaluiert. Hierfür wurden die Parameter Auslöseverzögerung, maximale Laufbandgeschwindigkeit und Abweichung der zu störenden Schritte untersucht sowie der Einfluss der Faktoren Plot, Ganggeschwindigkeit und Perturbationsintensität auf die Parameter bestimmt. Die Auslöseverzögerung liegt bei 0,24 ± 0,004 s und wird maßgeblich von dem Faktor Plot beeinflusst. Die maximale Laufbandgeschwindigkeit liegt bei 3,10 ± 0,03 m/s und wird signifikant von dem Faktor Störungsintensität beeinflusst. Die Abweichung der Schritte beträgt 3,9 ± 3,6 Schritte und wird stark von dem Faktor Plot beeinflusst. Die erreichten Werte sind für Studien mit normalen Ganggeschwindigkeiten und mittlerer Perturbationsintensität ausreichend. Für höhere Belastungen ist eine Überarbeitung des Matlab-Skripts erforderlich.