Refine
Year of publication
- 2013 (41) (remove)
Document Type
- Conference Proceeding (41) (remove)
Conference Type
- Konferenzartikel (28)
- Konferenz-Abstract (10)
- Sonstiges (2)
- Konferenz-Poster (1)
Is part of the Bibliography
- yes (41) (remove)
Keywords
- Herzkrankheit (3)
- Kommunikation (3)
- Synchronisierung (3)
- Batterie (2)
- Brennstoffzelle (2)
- Energieversorgung (2)
- Messung (2)
- RoboCup (2)
- Roboter (2)
- Sensortechnik (2)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (41) (remove)
Open Access
- Closed Access (21)
- Open Access (20)
- Bronze (3)
Das Ausmaß der elektrischen ventrikulären Desynchronisation bei reduzierter linksventrikulärer Funktion ist von Bedeutung für den Erfolg der Resynchronisationstherapie der Herzinsuffizienz mit biventrikulärer Stimulation. Das Ziel der Untersuchung besteht in der nichtinvasiven Messung der elektrischen inter-ventrikulären Desynchronisation mit und ohne ischämische Herzerkrankung bei kardialen Resynchronisationstherapie Respondern. Bei Patienten mit 25,3 ± 7,3 % reduzierter linksventrikulärer Ejektionsfraktion und 166,9 ± 38,5 ms QRS-Dauer wurde das transösophageale linksventrikuläre EKG abgeleitet. Die QRS-Dauer korrelierte mit dem interventrikulären und links-ventrikulären Delay bei Resynchronisationstherapie Respondern mit nicht-ischämischer Herzerkrankung.
In this paper we propose a motion framework forbipedal robots that decouples motion definitions from stabilizingthe robot. This simplifies motion definitions yet allows dynamicmotion adaptations. Two applications, walking and stopping onone leg, demonstrate the power of the framework. We show thatour framework is able to perform walking and stopping on one legeven under extreme conditions and improves walking benchmarkssignificantly in the RoboCup 3D soccer simulation domain.
Transösophageales interventrikuläres Delay bei Vorhofflimmern und kardialer Resynchronisation
(2013)
Die transösophageale linksventrikuläre Elektrokardiographie ermöglicht die Evaluierung der elektrischen ventrikulären Desynchronisation im Rahmen der kardialen Resynchronisationstherapie der Herzinsuffizienz. Das Ziel der Untersuchung besteht in der präoperativen Abschätzung des transösophagealen interventrikulären Delays bei Vorhofflimmern und kardialer Resynchronisationstherapie. Bei Patienten mit Vorhofflimmern, Herzinsuffizienz New York Heart Association Klasse 3,0 ± 0,2 und QRS-Dauer 159,6 ± 23,9 ms wurde das fokusierte transösophageale linksventrikuläre EKG abgeleitet. Die kardiale Resynchronisationstherapie Responder QRS-Dauer korrelierte mit dem transösophagealen interventrikulären Delay bei Vorhofflimmern.
This paper describes the magmaOffenburg 3D simulation team trying to qualify for RoboCup 2013. While last year’s TDP focused on different ways how robot behavior can be defined in the magmaOffenburg framework this year we focus on how we statistically evaluate new features on distributed systems. We also show some results gained through such analysis.
Ranging errors are inevitable in all local positioning systems, including those based on Time-of-Flight (ToF) technique. Results of experiments show that the major cause for these errors is a signal degradation from multipath propagation. This effect is especially critical in case of Non-Light-of-Sight (NLOS) conditions. This paper describes causes that affects ranging errors for nanoLOC™-TOF-technology and presents estimations for the probability density functions of such errors under different NLOS conditions. The provided estimations allow the improvement of the accuracy of the localization through the subsequent mitigation of the ranging errors from the measurements. Additionally, it is proposed to increase the number of cases of NLOS-conditions for the improvement of the accuracy.
Network landscape of recent time contains many different network technologies, a wide range of end-devices with a large scale of capabilities and power, and an immense quantity of information and data represented in different formats. Research on 3D imaging, virtual reality and holographic techniques will result in new user interfaces (UI) for mobile devices, will increase their diversity and variety. In this paper software architecture has been proposed to establish device and content format independent communication including 3D imaging and virtual reality data as content. As experimental validation the concept is implemented in collaborative Language Learning Game (LLG), which is a learning tool for language acquisition.
The combination of fossil-derived fuels with ethanol and methanol has acquired relevance and attention in several countries in recent years. This trend is strongly affected by market prices, constant geopolitical events, new sustainability policies, new laws and regulations, etc. Besides bio-fuels these materials also include different additives as anti-shock agents and as octane enhancer. Some of the chemical compounds in these additives may have harmful properties for both environment and public health (besides the inherent properties, like volatility). We present detailed Raman spectral information from toluene (C7H8) and ethanol (C2H6O) contained in samples of ElO gasoline-ethanol blends. The spectral information has been extracted by using a robust, high resolution Fourier-Transform Raman spectrometer (FT-Raman) prototype. This spectral information has been also compared with Raman spectra from pure additives and with standard Raman lines in order to validate its accuracy in frequency. The spectral information is presented in the range of 0 cm-1 to 3500 cm-1 with a resolution of 1.66cm-1. This allows resolving tight adjacent Raman lines like the ones observed around 1003cm-1 and 1030cm-1 (characteristic lines of toluene). The Raman spectra obtained show a reduced frequency deviation when compared to standard Raman spectra from different calibration materials. The FT-Raman spectrometer prototype used for the analysis consist basically of a Michelson interferometer and a self-designed photon counter cooled down on a Peltier element arrangement. The light coupling is achieved with conventional62.5/125μm multi-mode fibers. This FT-Raman setup is able to extract high resolution and frequency precise Raman spectra from the additives in the fuels analyzed. The proposed prototype has no additional complex hardware components or costly software modules. The mechanical and thermal disturbances affecting the FT-Raman system are mathematically compensated by accurately extracting the optical path information of the Michelson interferometer. This is accomplished by generating an additional interference pattern with a λ = 632.8 nm Helium-Neon laser (HeNe laser). It enables the FT-Raman system to perform reliable and clean spectral measurements from the materials under observation.
The formation of secondary phases in the porous electrodes is a severe mechanism affecting the lifetime of solid oxide fuel cells (SOFC). It can occur via various chemical mechanisms and it has a significant influence on cell performance due to pore clogging and deactivation of active surfaces and triple-phase boundary (TPB). We present a modeling and simulation study of nickel oxide formation (reoxidation) and carbon formation (coking) within the SOFC anode. We use a 2D continuum model based on a multi-phase framework [Neidhardt et al., J. Electrochem. Soc., 159, 9 (2012)] that allows the introduction of arbitrary solid phases (here: Ni, YSZ, NiO, Carbon) plus gas phase. Reactions between the bulk phases are modeled via interface-adsorbed species and are described by an elementary kinetic approach. Published experimental data are used for parameterization and validation. Simulations allow the prediction of cell performance under critical operation conditions, like (i) a non-fuel operation test, where NiO formation is taking place (Figure 1a), or (ii) an open circuit voltage (OCV) stability test under hydrocarbon atmosphere, where solid carbon is formed (Figure 1b). Results are applied for enhanced interpretation of experimental data and for prediction of safe operation conditions.
In the dual membrane fuel cell (DM-Cell), protons formed at the anode and oxygen ions formed at the cathode migrate through their respective dense electrolytes to react and form water in a porous composite layer called dual membrane (DM). The DM-Cell concept was experimentally proven (as detailed in Part I of this paper). To describe the electrochemical processes occurring in this novel fuel cell, a mathematical model has been developed which focuses on the DM as the characteristic feature of the DM-Cell. In the model, the porous composite DM is treated as a continuum medium characterized by effective macro-homogeneous properties. To simulate the polarization behavior of the DM-Cell, the potential distribution in the DM is related to the flux of protons and oxygen ions in the conducting phases by introducing kinetic and transport equations into charge balances. Since water pressure may affect the overall formation rate, water mass balances across the DM and transport equations are also considered. The satisfactory comparison with available experimental results suggests that the model provides sound indications on the effects of key design parameters and operating conditions on cell behavior and performance.
Special implant connection module was developed to combine full features of two commercial heart rhythm simulators, ARSI-4 and Intersim II, into a master-slave teaching system. Seven workstations were equipped with the Carelink and Homemonitoring remote patient monitoring systems. This combination enables in-vitro training of physicians, nurses and students in pace-maker and defibrillator measurements during implantation and individual programming in the follow-up. Thus, extended sets of arrhythmias and electrode problems can be used to simulate problems and their solutions in a wide range of the clinical routine.
In the brain-cell microenvironment, diffusion plays an important role: apart from delivering glucose and oxygen from the vascular system to brain cells, it also moves informational substances between cells. The brain is an extremely complex structure of interwoven, intercommunicating cells, but recent theoretical and experimental works showed that the classical laws of diffusion, cast in the framework of porous media theory, can deliver an accurate quantitative description of the way molecules are transported through this tissue. The mathematical modeling and the numerical simulations are successfully applied in the investigation of diffusion processes in tissues, replacing the costly laboratory investigations. Nevertheless, modeling must rely on highly accurate information regarding the main parameters (tortuosity, volume fraction) which characterize the tissue, obtained by structural and functional imaging. The usual techniques to measure the diffusion mechanism in brain tissue are the radiotracer method, the real time iontophoretic method and integrative optical imaging using fluorescence microscopy. A promising technique for obtaining the values for characteristic parameters of the transport equation is the direct optical investigation using optical fibers. The analysis of these parameters also reveals how the local geometry of the brain changes with time or under pathological conditions. This paper presents a set of computations concerning the mass transport inside the brain tissue, for different types of cells. By measuring the time evolution of the concentration profile of an injected substance and using suitable fitting procedures, the main parameters characterizing the tissue can be determined. This type of analysis could be an important tool in understanding the functional mechanisms of effective drug delivery in complex structures such as the brain tissue. It also offers possibilities to realize optical imaging methods for in vitro and in vivo measurements using optical fibers. The model also may help in radiotracer biomarker models for the understanding of the mechanism of action of new chemical entities.