Refine
Year of publication
- 2012 (51) (remove)
Document Type
- Conference Proceeding (29)
- Article (reviewed) (5)
- Article (unreviewed) (4)
- Patent (3)
- Part of a Book (2)
- Contribution to a Periodical (2)
- Working Paper (2)
- Bachelor Thesis (1)
- Book (1)
- Master's Thesis (1)
Conference Type
- Konferenzartikel (19)
- Konferenz-Abstract (7)
- Konferenzband (2)
- Sonstiges (1)
Keywords
- Mikroelektronik (2)
- Optimierung (2)
- RoboCup (2)
- Signaltechnik (2)
- Aircraft (1)
- Angewandte Informatik (1)
- Arzneimittelprüfung (1)
- Asynchronmaschine (1)
- Attenuation (1)
- BLE (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (51) (remove)
Open Access
- Open Access (28)
- Closed (10)
- Bronze (9)
- Closed Access (8)
The Humboldt digital library (HDL) represents an innovative system to access the works and legacy of Alexander von Humboldt in a digital form on the Internet (www.avhumboldt.net). It contributes to the key question about how to present interconnected data in an appropriate form using information technologies. The HDL has been created as a dynamic digital library with the capability of connecting multilingual and multimedia data from diverse online archives. Humboldt’s volumes have become available, but beyond that any relevant information related to the observations of Humboldt, even outside the works can become immediately accessible. This makes it possible to recognize natural changes and compare Humboldt’s descriptions with recent situations. The technology we have developed addresses the issues of sustainability and makes it possible to detect changes in the environment since the time of Humboldt’s observations.
Die immer weitreichenderen Anwendungen des Smart Metering und des Smart Grid stellen immer höhere Anforderungen an Kommunikationstechnologien, die die Zielkonflikte aus Echtzeitfähige, Stabilität, Kosten und Energieeffizienz möglichst anwendungsoptimiert und auf einem immer höheren Niveau lösen. Insbesondere im Bereich der so genannten Primärkommunikation zwischen einem Sensor- oder Aktorknoten und einem Datensammler mit Gatewayfunktionalität konnten in den vergangenen Jahren wesentliche Fortschritte erzielt werden. Zu nennen sind hierbei insbesondere die Aktivitäten der ZigBee Alliance rund um den offenen Spezifikationsprozess des ZigBee Smart Energy Profiles (SEP) und der OMS-Gruppe beim ZVEI, die auf dem Wireless M-Bus nach EN13757-4 aufbauen, der sich seinerseits lebhaft und zielgerichtet weiter entwickelt. Der Beitrag diskutiert die vorhandenen Einschränkungen und die verfügbaren Lösungsansätze. Er illustriert diese anhand einiger öffentlich geförderter Projekte, an denen das Team des Autors beteiligt ist.
Es sollte in dieser Schrift untersucht werden, inwieweit bei Änderungen im Bereich der Planung, Durchführung und Auswertung von klinischen Arzneimittelprüfungen die Bewertung mit wissenschaftlichen oder politischen Begründungen erfolgt und inwieweit wissenschaftliche Regeln für politische Zwecke genutzt werden.
The invention relates to a container (1) for a liquid medium (3), in particular a blood bag, comprising a flexible outer wall (5) and a device (13) connected to the container (1) for acquiring and/or storing data. According to the invention, the device (13) for acquiring and/or storing data is arranged within the flexible outer wall (5), wherein positioning means (15) are provided which hold the device (13) for acquiring and/or storing data in a floating manner in the liquid medium when the container (1) is filled with said liquid medium (3), and wherein the device (13) or the device (13) and the positioning means (15) are designed such that the mass of liquid medium (3) which is displaced in each case is essentially equal to the mass of the device (13) or to the mass of the device (13) and the positioning means (15).
Die Erfindung betrifft ein Behältnis (1) für ein flüssiges Medium (3), insbesondere Blutbeutel, mit einer flexiblen Außenwandung (5) und einer mit dem Behältnis (1) verbundenen Vorrichtung (13) zur Erfassung und/oder Speicherung von Daten. Erfindungsgemäß ist die Vorrichtung (13) zur Erfassung und/oder Speicherung von Daten innerhalb der flexiblen Außenwandung (5) angeordnet, wobei Positionierungsmittel (15) vorgesehen sind, welche die Vorrichtung (13) zur Erfassung und/oder Speicherung von Daten bei mit dem flüssigen Medium (3) gefüllten Behältnis (1) schwimmend im flüssigen Medium (3) halten, und wobei die Vorrichtung (13) oder die Vorrichtung (13) und die Positionierungsmittel (15) so ausgebildet sind, dass die jeweils verdrängte Masse von flüssigem Medium (3) im Wesentlichen gleich der Masse der Vorrichtung (13) oder der Masse der Vorrichtung (13) und der Positionierungsmittel (15) ist.
Seit den ersten Projekten der 90er Jahre arbeiten Hochschulen daran, geeignete Servicestrukturen für E-Learning zu etablieren, die die erforderliche technische, didaktische und organisatorische Unterstützung hochschulweit zur Verfügung stellen. Ging es zunächst darum, Services überhaupt dauerhaft zu sichern, steht heute die Frage des „wie“ im Vordergrund. Dabei wird am Bereich E-Learning ein eigentlich viel allgemeineres Problem deutlich: Die bisher überwiegende Organisation der Hochschule nach funktionellen Einheiten stößt an ihre Grenzen. Wir schlagen eine stärker prozessorientierte Sichtweise vor, analog zu Entwicklungen bei der Organisation von Unternehmen.
The following paper presents the results of a feasibility study about Bluetooth Low Energy (BLE) based wireless sensors. The development of industrial wireless sensors leads to important demands for the wireless technologies like a low energy consumption and a resource saving simple protocol stack. Bluetooth Low Energy (BLE) is a rather new wireless standard which will completely fulfill these fundamental requirements. A self-designed BLE sensor system has been used to explore the common applicability of BLE for wireless sensor systems. The evaluation results of various analyses with the BLE sensor system are now presented in this paper.
Die Erfindung betrifft ein Behältnis (1) für ein flüssiges Medium (3), insbesondere Blutbeutel, mit einer flexiblen Außenwandung (5) und einer mit dem Behältnis (1) verbundenen Vorrichtung (13) zur Erfassung und/oder Speicherung von Daten. Erfindungsgemäß ist die Vorrichtung (13) zur Erfassung und/oder Speicherung von Daten innerhalb der flexiblen Außenwandung (5) angeordnet, wobei Positionierungsmittel (15) vorgesehen sind, welche die Vorrichtung (13) zur Erfassung und/oder Speicherung von Daten bei mit dem flüssigen Medium (3) gefüllten Behältnis (1) schwimmend im flüssigen Medium (3) halten, und wobei die Vorrichtung (13) oder die Vorrichtung (13) und die Positionierungsmittel (15) so ausgebildet sind, dass die jeweils verdrängte Masse von flüssigem Medium (3) im Wesentlichen gleich der Masse der Vorrichtung (13) oder der Masse der Vorrichtung (13) und der Positionierungsmittel (15) ist.
This paper describes the magmaOffenburg 3D simulation team trying to qualify for RoboCup 2012. While last year’s TDP focused on the tool set created for 3D simulation and the support for heterogeneous robot models, this year we focus on the different ways how robot behavior can be defined in the magmaOffenburg framework and how those behaviors can be improved by learning.
Experiences with a telecare platform integration of ZigBee sensors into a middleware platform
(2012)
Responder-rate in cardiac resynchronization therapy (CRT) of patients in sinus rhythm (SR) or atrial fibrillation (AF) mainly depends on accurat selection, optimal position of the left ventricular electrode and individualization of hemodynamical parameters of the implanted biventricular pacing system during follow-up. High resolution esophageal left heart electrocardiography offers a quick and semi-invasive approach to the electrical activity of left atrium and left ventricle. It was used in 62 heart failure patients in sinus rhythm and 11 in atrial fibrillation after implantation of CRT systems to compare the semi-invasive interventricular conduction delay (IVCDE) with QRS width. In all of the patients, guideline decision for CRT was linked with IVCDE of about 40ms and up. From logical point of view, IVCDE provides the minimal target interval for the left ventricular electrode placement in order to exclude non-responders. Esophageal measurement of interatrial conduction intervals in VDD and DDD pacing was utilized to individualize the AV delay and to exclude adverse hemodynamic effects.
Geleitwort
(2012)
Capture threshold (CT) for transesophageal left atrial (LA) pacing (TLAP) and transesophageal left ventricular (LV) pacing (TLVP) with conventional cylindrical electrodes (CE) are higher than TLAP feeling threshold (FT). Purpose of the study was to evaluate focused TLAP CT and FT for supraventricular tachycardia (SVT) initiation and focused TLVP CT for cardiac resynchronisation therapy (CRT) simulation.
Methods: SVT initiation in patients (P) with palpitations (n=49, age 47 ± 17 years) was analysed during spontaneous rhythm and during focused bipolar TLAP with atrial constant current stimulus output, distal CE and three or seven 6 mm hemispherical electrodes (HE) (TO, Osypka AG, Rheinfelden, Germany). CRT simulation in heart failure P (n=75, age 62 ± 11 years) was evaluated by focused bipolar TLAP and/or TLVP with ventricular constant voltage stimulus output and different pacing mode.
Results: Focused electrical pacing field between CE and HE (n=28) allowed low threshold TLAP with 8.0 ± 2.6 mA CT at 9.9 ms stimulus duration (SD) which was lower than 9.2 ± 4.5 mA FT at 9.9 ms SD. Focused electrical pacing field between HE and HE (n=21) allowed low threshold TLAP with 8.1 ± 2.2 mA CT at 9.9 ms SD which was lower than 9.8 ± 5.0 mA FT at 9.9 ms SD. SVT initiation by programmed AAI TLAP was possible in 23 P and not possible in 26 P. CRT simulation was evaluated with TLAP and TLVP with VAT, D00 and V00 pacing mode and 95.5 ± 10.9 V TLVP CT at 4.0 ms SD.
Conclusions: Programmed focused AAI TLAP allowed initiation of SVT with very low CT and high FT and focused electrical pacing field between CE-HE and HE-HE.CRT simulation with focused TLAP and/or TLVP with VAT, D00 and V00 pacing mode may be a useful technique to detect responders to CRT.
Cardiac resynchronization therapy (CRT) with biventricular (BV) pacing is an established therapy in approximately two-thirds of symptomatic heart failure (HF) patients (P) with left bundle branch block (LBBB). The aim of this study was to evaluate left atrial (LA) conduction delay (LACD) and left ventricular (LV) conduction delay (LVCD) using pre-implantational transesophageal electrocardiography (ECG) in sinus rhythm (SR) CRT responder (R) and non-responder (NR).
Methods: SR HF P (n=52, age 63.6±10.4 years; 6 females, 46 males) with New York Heart Association (NYHA) class 3.0±0.2, 24.4±7.1 % LV ejection fraction and 171.2±37.6 ms QRS duration (QRSD) were measured by bipolar filtered transesophageal LA and LV ECG recording with hemispherical electrodes (HE) TO catheter (Osypka AG, Rheinfelden, Germany). LACD was measured between onset of P-wave in the surface ECG and onset of LA deflection in the LA ECG. LVCD was measured between onset of QRS in the surface ECG and onset of LV deflection in the LV ECG.
Results: There were 78.8 % SR CRT R (n=41) with 171.2±36.9 ms QRSD, 73.3±25.7 ms LACD, 80.0±24.0 ms LVCD and 2.3±0.5 QRSD-LVCD-ratio. SR CRT R QRSD correlated with LACD (r=0.688, P<0.001) and LVCD (r=0.699, P<0.001). There were 21.2 % SR CRT NR (n=11) with 153.4±22.4 ms QRSD (P=0.133), 69.8±24.8 ms LACD (n=6, P=0.767), 54.2±31.0 ms LVCD (P<0.0046) and 3.9±2.5 QRSD-LVCD-ratio (P<0.001). SR CRT NR QRSD not corre-lated with IACD (r=-0.218, P=0.678) and IVCD (r=0.042, P=0.903). During a 22.8±21.3 month CRT follow-up, the CRT R NYHA class improved from 3.1±0.3 to 1.9±0.3 (P<0.001). In CRT NR, NYHA class not improved (2.9±0.4 to 2.9±0.2, P=1) during 11.2±9.8 months BV pacing.
Conclusions: Transesophageal LA and LV ECG with HE can be utilized to analyse LACD and LVCD in HF P. Pre-implantational LVCD and QRSD-LVCD-ratio may be additional useful parameters to improve P selection for SR CRT.
Machine-to-machine communication is continuously extending to new application fields. Especially smart metering has the potential to become the first really large-scale M2M application. Although in the future distributed meter devices will be mainly connected via dedicated primary communication protocols, like ZigBee, Wireless
M-Bus or alike, a major percentage of all meters will be connected via point to point communication using GPRS or UMTS platforms. Thus, such meter devices have to be extremely cost and energy efficient, especially if the devices are battery based and powered several years by a single battery. This paper presents the development of an automated measurement unit for power and time, thus energy characteristics can be recorded. The measurement unit includes a hardware platform for the device
under test (DUT) and a database based software environment for a smooth execution and analysis of the measurements.