We present a densitometric quantification method for triclosan in toothpaste, separated by high-performance thin-layer chromatography (HPTLC) and using a 48-bit flatbed scanner as the detection system. The sample was band-wise applied to HPTLC plates (10 × 20 cm), with fluorescent dye, Merck, Germany (1.05554). The plates were developed in a vertical developing chamber with 20 min of chamber saturation over 70 mm, using n-heptane–methyl tert-butyl ether–acetic acid (92:8:0.1, V/V) as solvent. The RF value of triclosan is hRF = 22.4, and quantification is based on direct measurements using an inexpensive 48-bit flatbed scanner for color measurements (in red, green, and blue) after plate staining with 2,6-dichloroquinone-4-chloroimide (Gibbs' reagent). Evaluation of the red channel makes the measurements of triclosan very specific. For linearization, an extended Kubelka–Munk expression was used for data transformation. The range of linearity covers more than two orders of magnitude and is between 91 and 1000 ng. The separation method is inexpensive, fast and reliable.
We present a video-densitometric high-performance thin-layer chromatography (HPTLC) quantification method for patulin in apple juice, developed in a vertical chamber from the starting point to a distance of 50 mm, using MTBE, n-pentane (9 + 5, v/v) as mobile phase. After separation the plate is sprayed with methyl-benzothiazolinone hydrazone hydrochloride monohydrate (MBTH) solution (40 mg in 20 mL methanol) and heated at 105 °C for 15 min. Patulin zones are transformed into yellow spots. The quantification is based on direct measurements using an inexpensive 48-bit flatbed scanner for color measurements (in red, green, and blue). Evaluation of the blue channel makes the measurements very specific. Quantification in fluorescence was also done by use of a 16-bit CCD-camera and UV-366 nm illumination as well as using a HPTLC DAD-scanner. For linearization the extended Kubelka–Munk expression for data transformation was used. The range of linearity covers more than two magnitudes and lies between 5 and 800 ng patulin. The extraction of 20 g apple juice and an extract application on plate up to 50 µL allows statistically defined checking the limit of detection (LOD) of 50 ng patulin per track, which is equivalent to 50 µg patulin per kg apple juice.