Refine
Year of publication
Document Type
- Article (reviewed) (43)
- Contribution to a Periodical (27)
- Article (unreviewed) (16)
- Conference Proceeding (9)
- Patent (9)
- Part of a Book (4)
- Book (2)
Conference Type
- Konferenzartikel (8)
- Konferenz-Abstract (1)
Is part of the Bibliography
- yes (110)
Keywords
- Dünnschichtchromatographie (27)
- Chromatographie (7)
- HPTLC (6)
- Chromatography (5)
- Faseroptik (5)
- Laboratory Medicine (5)
- Monitoring/Environmental Analysis (5)
- Pharmacy (5)
- Analyse (4)
- Densitometrie (3)
Institute
Open Access
- Open Access (37)
- Closed Access (34)
- Hybrid (20)
- Closed (14)
- Gold (1)
Die quantitative Dünnschichtchromatographie (HPTLC) mit einem Graustufen-Handscanner ist eine preiswerte, schnelle und präzise Methode zur Schwermetallbestimmung. Als Alternative zu teuren Densitometern wird ein Grünlichtscanner mit einer Auflösung von 256 Graustufen benutzt. Die Ortsauflösung beträgt maximal 400 dpi (dots per inch). Die Chromatogramme werden mit 300 dpi aufgenommen. Zur Entwicklung wird eine Camag-Linearkammer verwendet. Zur Probenvorbereitung werden die zu bestimmenden Schwermetallionen bei pH 4,2 mit Dithizon komplexiert. Nur die Metallkationen Zn(2+), Co(2+), Hg(2+), Cd(2+) und Ni(2+) reagieren zu einem farbigen Metallkomplex, wobei sich Zn(2+)- und Co(2+)-Komplexe chromatographisch abtrennen lassen. Nach Komplexierung der Wasserprobe wird mit Essigsäureethylester ausgeschüttelt, Probe- und Standardlösung auf eine Platte aus Kieselgel SI-60 aufgetragen, mit Essigsäureethylester fokussiert und nach der Trocknung der Platte mit Toluol entwickelt. Die HPTLC-Platte wird mit scannereigener Software eingelesen und im PCX-Format (PC PaintBrusch der Fa. ZSoft) auf die Festplatte abgelegt. Zur Auswertung wird eine Leseroutine benutzt. Die ganze Chromatographiebahn ist mit 150 Einzeldioden aufgenommen, die eine Strecke von 48 mm in 564 Einzelmessungen auflösen. Die Summe aller 150 Einzelaufnahmen liefert das Densitogramm aus dem der Schwermetallgehalt bestimmt wird.
Eine einfache Bestimmung von Mineraloel-KWstoffen - Ersatz des FCKW-haltigen Extraktionsmittels
(1996)
Die Messung von KWstoffen in Abwaessern nach DIN ist eine in der Umweltanalytik haeufig geforderte Bestimmung. Die Abwasserprobe wird dabei mit 1,1,2-Trichlortrifluorethan extrahiert. Anschliessend wird der Extrakt mittels IR-Spektroskopie vermessen. Neben einigen Schwaechen ist bei dieser Bestimmungsmethode besonders die Verwendung des ozonschaedigenden FCKW-Loesemittels heute nicht mehr zeitgemaess. - Die Verf. beschreiben ein schnelles robustes Bestimmungsverfahren, das alle Schwaechen der alten Methode vermeidet.
Nativ-organische Abfälle bilden mit ca. 30 Gew. % den Hauptteil des Hausmülls. Daher leistet die Bioabfallkompostierung einen bedeutenden Schritt hin zu einer sinnvollen Abfallverwertung. Bundesweit werden derzeit jährlich etwa 750 000 t Bioabfallkompost erzeugt. Mit Ausnahme von sieben Land- und Stadtkreisen planen die Landkreise Baden-Württembergs die getrennte Sammlung von Bioabfällen: Einwohner von 23 Landkreisen waren 1993, zum Teil versuchsweise, an Biotonnen angeschlossen. Die Notwendigkeit der Bioabfallkompostierung scheint außer Frage zu stehen, intensiv erörtert werden jedoch die Verfahrenskonzepte, die der Bioabfallkompostierung zugrunde liegen. Kern der Diskussion ist, ob einfache Kompostierungsverfahren wie die dezentrale Kompostierung den technisch aufwendigeren Verfahren zentraler Anlagen gleichwertig sind.
Als erster Landkreis in Baden Württemberg hat der Landkreis Sigmaringen bei der Entsorgung des bei 120 000 Einwohnern im Kreis anfallenden organischen Abfalls neue Wege beschritten und die Landwirtschaft in den Stoffkreislauf miteinbezogen, anstatt das anfallende Material zu deponieren. Auf dem Hintergrund der TA-Siedlungsabfall, die vorschreibt, daß nach einer Übergangszeit organische Abfälle nicht mehr deponiert werden dürfen, sondern kompostiert oder thermisch behandelt werden müssen, hat der Landkreis Sigmaringen im Jahr 1992 ein Konzept zur dezentralen Kompostierung verabschiedet.
An algorithm is presented that has successfully been utilized in practice for several years. It improves data analysis in chromatography. The program runs in an extremely reliable way and evaluates chromatographic raw data with an acceptable error. The algorithm requires a minimum of preliminaries and integrates even unsmoothed noisy data correctly.
Alle Materie strebt nach maximaler Unordnung. Diese Erkenntnis wird durch die thermodynamische Funktion der Entropie beschrieben. Auch bei jeglicher Art menschlichen Handelns wird die Entropie immer erhöht. Wird in der Technik Materie in geordnete Formen gebracht (z. B. beim Herstellen von Pfandflaschen), findet in diesem Produkt eine Entropieerniedrigung statt. Gleichzeitig wird aber an anderer Stelle die Unordnung beträchtlich vergrößert. Diese Entropieerhöhung nennen wir Abfall. Jede Entropieerhöhung ist mit dem Verbrauch wertvoller Ressourcen verbunden. Durch eine optimale Recyclingtechnik kann einer Entropieerhöhung von Materie entgegengearbeitet werden. Aber nur Recyclingraten von über 90 % erlauben eine wirksame Streckung der Ressourcen.
In this paper a high-performance thin-layer chromatography (HPTLC) scanner is presented in which a special fibre arrangement is used as HPTLC plate scanning interface. Measurements are taken with a set of 50 fibres at a distance of 400 to 500 μm above the HPTLC plate. Spatial resolutions on the HPTLC plate of better than 160 μm are possible. It takes less than 2 min to scan 450 spectra simultaneously in a range of 198 to 610 nm. The basic improvement of the item is the use of highly transparent glass fibres which provide excellent transmission at 200 nm and the use of a special fibre arrangement for plate illumination and detection.
HPTLC (High Performance Thin Layer Chromatography) is a well known and versatile separation method which shows many advantages when compared to other separation techniques. The method is fast and inexpensive and does not need time-consuming pretreatments. For visualisation of the sample distribution on a HPTLC-plate we developed a new and sturdy HPTLC-scanner. The scanner allows simultaneous registrations of spectra in a range from 198 nm to 612 nm with a spectral resolution of better than 0.8 nm. The on-plate spatial resolution is better than 160 μm. The measurement of 450 spectra in one separation track does not need more than two minutes. The new diode-array scanner offers a fast survey over a TLC-separation and makes various chemometric applications possible. For compound identification a cross-correlation function is described to compare UV sample spectra with appropriate library data. The cross-correlation function herein described can also be used for purity testing. Unresolved peaks can be virtually separated by use of a least squares fit algorithm. In summary, the diode arry system delivers much more information than the commonly used TLC-scanner.
High performance thin layer chromatography (HPTLC) is a frequently used separation technique which works well for quantification of caffeine and quinine in beverages. Competing separation techniques, e.g. high-performance liquid chromatography (HPLC) or gas chromatography (GC), are not suitable for sugar-containing samples, because these methods need special pretreatment by the analyst. In HPTLC, however, it is possible to separate ‘dirty’ samples without time-consuming pretreatment, because disposable HPTLC plates are used. A convenient method for quantification of caffeine and quinine in beverages, without sample pretreatment, is presented below. The basic theory of in-situ quantification in HPTLC by use of remitted light is introduced and discussed. Several linearization models are discussed.
A home-made diode-array scanner has been used for quantification; this, for the first time, enables simultaneous measurements at different wavelengths. The new scanner also enables fluorescence evaluation without further equipment. Simultaneous recording at different wavelengths improves the accuracy and reliability of HPTLC analysis. These aspects result in substantial improvement of in-situ quantitative densitometric analysis and enable quantification of compounds in beverages.
A new diode-array scanner in combination with a computer-controlled application system meets all the demands of modern HPTLC measurement. Automatic application, simultaneous measurements at different wavelengths, and different linearization models enable appropriate evaluation of all analytical questions. The theory of error propagation recommends quantification at reflectance values smaller than 0.8; this can be verified only by use of diode-array scanning. The same theory also recommends quantification by use of peak height data, because the theory predicts best precision only for peak height evaluation. Diode-array scanning with reflectance monitoring enables appropriate validation in TLC and HPTLC analysis. All these aspects result in substantial improvement of in-situ quantitative densitometric analysis, and simultaneous recording at different wavelengths opens the way for chemometric evaluation, e.g. peak purity monitoring, which improves the accuracy and reliability of HPTLC analysis.
A systematic toxicological analysis procedure using high-performance thin layer chromatography in combination with fibre optical scanning densitometry for identification of drugs in biological samples is presented. Two examples illustrate the practicability of the technique. First, the identification of a multiple intake of analgesics: codeine, propyphenazone, tramadol, flupirtine and lidocaine, and second, the detection of the sedative diphenhydramine. In both cases, authentic urine specimens were used. The identifications were carried out by an automatic measurement and computer-based comparison of in situ UV spectra with data from a compiled library of reference spectra using the cross-correlation function. The technique allowed a parallel recording of chromatograms and in situ UV spectra in the range of 197–612 nm. Unlike the conventional densitometry, a dependency of UV spectra by concentration of substance in a range of 250–1000 ng/spot was not observed.
HPTLC (High Performance Thin Layer Chromatography) is a well known and versatile separation method which shows a lot of advantages and options in comparison to other separation techniques. The method is fast and inexpensive and does not need time-consuming pretreatments. Using fiber-optic elements for controlled light-guiding, the TLC-method was significantly improved: the new HPTLC-system is able to measure simultaneously at different wavelengths without destroying the plate surface or the analytes on the surface. For registration of the sample distribution on a HPTLC-plate we developed a new and sturdy diode-array HPTLC- scanner which allows registration of spectra on the TLC- plates in the range of 198 nm to 610 nm with a spectral resolution better than 1.2 nm. The spatial resolution on plate is better than 160 micrometers . In the spectral mode, the new HPTLC-scanner delivers much more information than the commonly used TLC-scanner. The measurement of 450 spectra of one separation track does not need more than three minutes. However, in the fixed wavelength mode the contour plot can be measured within 15 seconds. In this case, the signal will be summarized and averaged over a spectral range having FWHM from 10 nm to 25 nm depending on the substance under test. The new diode-array HPTLC-scanner makes various chemometric applications possible. The new method can be used easily in clinical diagnostic systems easily, e.g. for blood and uring investigations. In addition, new applications are possible. For example, the rich structured PAHs were studied. Although the separation is incomplete the 16 compounds can be quantified using suitable wavelengths.
The use of a TLC scanner can be regarded as a key step in high performance thin layer chromatography (HPTLC). Densitometric measurements transform the substance distribution on a TLC plate into digital computer data. Systems that allow quantitative measurements have been available for many years for either fluorescence or ultraviolet absorption measurements, while lately the reflection analysis mode for both types is the most common application. New scanning approaches are designed to aid the analyst who has common demands for TLC-densitometry without using special data, such as scanned images. Two examples that have been developed lately in the laboratories of the authors are described in this paper. These approaches were developed on the basis of current needs for analysts who employ TLC as a tool in research, as well as in routine analysis. One approach is aimed to support analysts in economically disadvantaged areas, where cost intensive apparatus is unsuitable but trace analysis by simple means is required. The other system, allows the spectral determination of chromatographic spots on TLC plates covering the ultraviolet and visible range, thus, revealing highly desired information for the analyst.
A Simple and Reliable HPTLC Method for the Quantification of the Intense Sweetener Sucralose®
(2003)
This paper describes a simple and fast thin layer chromatography (TLC) method for the monitoring of the relatively new intense sweetener Sucralose® in various food matrices. The method requires little or no sample preparation to isolate or concentrate the analyte. The Sucralose® extract is separated on amino‐TLC‐plates, and the analyte is derivatized “reagent‐free” by heating the developed plate for 20 min at 190°C. Spots can be measured either in the absorption or fluorescence mode. The method allows the determination of Sucralose® at the levels of interest regarding foreseen European legislation (>50 mg/kg) with excellent repeatability (RSD = 3.4%) and recovery data (95%).
Fluorescence Enhancement of Pyrene Measured by Thin-Layer Chromatography with Diode-Array Detection
(2003)
In-situ densitometry for qualitative or quantitative purposes is a key step in thin-layer chromatography. It offers a simple way of quantifying by measuring the optical density of the separated spots directly on the plate. A new TLC scanner has been developed which is able to measure TLC plates or HPTLC plates, at different wavelengths simultaneously, without destroying the plate surface. The system enables absorbance and fluorescence measurements in one run. Fluorescence measurements are possible without filters or other adjustments.
The measurement of fluorescence from a TLC plate is a versatile means of making TLC analysis more sensitive. Fluorescence measurements with the new scanner are possible without filters or special lamps. Improvement of the signal-to-noise ratio is achieved by wavelength bundling. During plate scanning the scattered light and the fluorescence are both emitted from the surface of the TLC plate and this emitted light provides the desired spectral information from substances on the TLC plate. The measurement of fluorescence spectra and absorbance spectra directly from a TLC plate is based on differential measurement of light emerging from sample-free and sample-containing zones.
The literature recommends dipping TLC plates in viscous liquids to enhance fluorescence. Measurement of the fluorescence and absorbance spectra of pyrene spots reveals the mechanism of enhancement of plate dipping in viscous liquids—blocked contact of the fluorescent molecules with the stationary phase or other sample molecules is responsible for the enhanced fluorescence at lower concentrations.
In conclusion, dipping in TLC analysis is no miracle. It is based on similar mechanisms observable in liquids. The measured TLC spectra are also very similar to liquid spectra and this makes TLC spec-troscopy an important tool in separation analysis.
Vorgestellt wird die Dioden-Array-Dünnschichtchromatographie als eine moderne und preiswerte Messmethode zur densitometrischen Erfassung von Substanzen auf einer DC- oder einer HPTLC-Platte. Sicher identifizierbar sind auch Substanzen mit schwachem Chromophor. Die Kubelka-Munk-Gleichung beschreibt einen linearen Zusammenhang zwischen Remissionslicht und lichtabsorbierender Stoffmenge auf der Platte. Die Auswertung im Spektralbereich von 316 bis 334 nm zeigt den Zusammenhang zwischen transformiertem Messsignal und aufgetragener Substanzmasse. Die schnelle Aufnahme von UV/vis-Spektren eröffnet der HPTLC den gesamten Bereich der Methodenvalidierung auf dem Niveau, auf welchem heute die HPLC-Analytik durchgeführt wird.
Quantitative Bestimmung von Clozapin im Serum mittels Dioden-Array Dünnschichtchromatographie
(2003)
A new formula is presented for transforming fluorescence measurements in accordance with Kubelka-Munk theory. The fluorescence signals, the absorption signals, and data from a selected reference are combined in one expression. Only diode-array techniques can measure all the required data simultaneously to linearize fluorescence data correctly. To prove the new theory HPTLC quantification of the analgesic flupirtine was performed over the mass range 300 to 5000 ng per spot. The fluorescence calibration curve was linear over the whole range. The transformation of fluorescence measurements into linear mass-dependent data extends the technique of in-situ fluorescence analysis to the high concentration range. It also extends Kubelka-Munk theory from absorption to fluorescence analysis. The results presented also emphasize the importance of Kubelka-Munk theory for in-situ measurements in scattering media, especially in planar chromatography.
Thin-layer chromatography (TLC) is a well-established and widely used separation technique. Most undergraduate students of chemistry or food science used TLC as a primitive separation tool, which does not need more than small pieces of TLC plates, a glass jar and some solvents. TLC has evolved from a simple separation method of the past into an instrumental technique that offers automation, reproducibility and accurate quantification for a wide variety of applications [1]. The use of modern 10*10 cm TLC plates with narrow particle size distribution is called high performance thin layer chromatography (HPTLC), to distinguish the method from the use of traditional 20 20 cm TLC plates.
Diode-array planar chromatography is a versatile tool for identification of pharmaceutical substances In this paper thirty-three compounds with benzodiazepine properties were investigated and the separating conditions for silica gel HPTLC plates and three mobile phases were optimized. Diode-array HPTLC makes it possible to identify all the compounds with high certainty down to a level of 20 ng. An algorithm for spectral recognition which is combined with R F values from the three separation steps into one fit factor is presented. This set of data is unique for each of the compounds investigated and enables unequivocal identification. The method is rapid, inexpensive, and sensitive down to a level of 20 ng mL −1.
In thin-layer chromatography the development step distributes the sample throughout the layer, a process which strongly affects the reflection signals. The essential requirement for quantitative thinlayer chromatography is not a constant sample concentration but constant sample distribution in each sample spot. This makes evaporation of the mobile phase extremely important, because all tracks of a TLC plate must be dried uniformly. This paper shows that quantitative TLC is possible even if the concentration of the sample is not constant throughout the layer or if the distribution of the sample is not known. With uniform sample distribution, classical Kubelka-Munk theory is valid for isotropic scattering only. In the absence of this constraint classical Kubelka-Munk theory must be extended to situations where scattering is asymmetric. This can be achieved by modification of the original Kubelka-Munk equation. Extended theory is presented which is not only capable of describing asymmetrical scattering in TLC layers but also includes a formula for absorption and fluorescence in diode-array TLC. With this new theory all different formulas for diode-array thin-layer chromatographic evaluation are combined in one expression.
In thin-layer chromatography, fiber-bundle arrays have been introduced for spectral absorption measurements in the UV-region. Using all-silica fiber bundles, the exciting light will be detected after re-emission on the plate with a fiberoptic spectrometer. In addition, fluorescence light can be detected which will be masked by the re-emitted light. Therefore, it is helpful to separate the absorption and fluorescence on the TLC-plate. A modified three-array assembly has been developed: using one array for detection, the two others are used for excitation with broadband band deuterium-light and with UV-LEDs adjusted to the substances under test. As an example, the quantification of glucosamine in nutritional supplements or spinach leaf extract will be described. Using simply heating of the amino-plate for derivation, the reaction product of Glucosamine can be detected sensitively either by light absorption or by fluorescence, using the new fiber-optic assembly. In addition, the properties of the new 3-row fiber-optic array and the commercially available UV-LEDs will be shown, in the interesting wavelength region for excitation of fluorescence, from 260 nm to 360 nm. The squint angle having an influence on coupling efficiency and spatial resolution will be measured with the inverse farfield method. Some properties of UV-LEDs for analytical applications will be described and discussed, too.
Previous studies of the hyphenation of gas chromatographic separation and spectrophotometric detection in the ultraviolet wavelength range between 168 and 330 nm showed a high potential for applications where the analysis of complex samples is required. Within this paper the development of a state-of-the-art detection system for compounds in the vapour phase is described, offering an improved behaviour compared to previous systems: Dependent on the requirements of established detection systems hyphenated with gas chromatography, the main components of the system have to be designed for optimum performance and reliability of the spectrophotometric detector: A deuterium lamp as a broadband light source has been selected for improved stability in the measurements. A new-type absorption cell based on fiber-optics has been developed considering the dynamic necessary to compete with existing techniques. In addition, the influence of the volume of the cell on the chromatogram needs to be analyzed. Tests for determining the performance of the absorption cell in terms of chemical and thermal influences have been carried out. A new spectrophotometer with adequate spectral resolution in the wavelength range, offering improved stability and dynamic for an efficient use in this application was developed. Furthermore, the influence of each component on the performance, reliability and stability of the sensor system will be discussed. An overview and outlook over the potential applications in the environmental, scientific and medical field will be given.
In-situ densitometry for qualitative or quantitative purposes is a key step in thin-layer chromatography (TLC). It is a simple means of quantification by measurement of the optical density of the separated spots directly on the plate. A new scanner has been developed which is capable of measuring TLC or HPTLC (high-performance thin-layer chromatography) plates simultaneously at different wavelengths without damaging the plate surface. Fiber optics and special fiber interfaces are used in combination with a diode-array detector. With this new scanner sophisticated plate evaluation is now possible, which enables use of chemometric methods in HPTLC. Different regression models have been introduced which enable appropriate evaluation of all analytical questions. Fluorescent measurements are possible without filters or special lamps and signal-to-noise ratios can be improved by wavelength bundling. Because of the richly structured spectra obtained from PAH, diode-array HPTLC enables quantification of all 16 EPA PAH on one track. Although the separation is incomplete all 16 compounds can be quantified by use of suitable wavelengths. All these aspects are enable substantial improvement of in-situ quantitative densitometric analysis.
The identification and quantification of compounds in the gas phase becomes of increasing interest in the context of environmental protection, as well as in the analytical field. In this respect, the high extinction coefficients of vapours and gases in the ultraviolet wavelength region allow a very sensitive measurement system. In addition, the increased performance of the components necessary for setting up a measurement system, such as fibres, light sources and detectors has been improved. In particular the light sources and detectors offer improved stability, and the deep UV performance and solarisation resistance of fused silica fibres allow have been significantly optimized in the past years. Therefore a compact and reliable detection system with high measuring accuracy is developed. Within this paper possible applications of the system under development and recent results will be discussed.
HPTLC on amino plates, with simple heating of the plates for derivatization, has been used for quantification of glucosamine in nutritional supplements. On heating the plate glucosamine reacts to form a compound which strongly absorbs light between 305 and 330 nm, with weak fluorescence. The reaction product can be detected sensitively either by absorption of light or by fluorescence detection. The detection limit in absorption mode is approximately 25 ng per spot. In fluorescence mode a detection limit of 15 ng is achievable. A calibration plot for absorption detection is linear in the range 25 to 4000 ng glucosamine. The derivative formed from glucosamine by heating is stable for months, and the relative standard deviation is 1.64% for 600 ng glucosamine. The amounts of glucosamine found in nutritional supplements were in agreement with the label declarations.
We present an improved quantification method for urethane found in spirits. The quantification is based on a derivatization reaction using cinnamaldehyde in combination with phosphoric acid. Measurements were carried out in the wavelength range from 445 to 460 nm using a diode-TLC device. An LED was used for illumination purposes. It emits very dense light at 365 nm. The quantification range of urethane is in the lower ng range. By applying 20 µL of sprits, the urethane quantification range is from 320 µg/L to 8.1 mg urethane per litre of spirit. The range of linearity covers nearly two magnitudes. The method is cheap, fast and reliable, and is able to monitor all European legislation limits without time-consuming sample pre-treatments.
An interlaboratory comparison was carried out to evaluate the effectiveness of a method based on HPTLC in which reagent-free derivatization is followed by UV/fluorescence detection. The method was tested for the determination of sucralose (C12H19C13O8; (2R,3R,4R,5S,6R)-2-[(2R,3S,4S,5S)-2,5-bis(chloromethyl)-3,4-dihydroxyoxolan-2-yl]oxy-5-chloro-6-hydroxymethyl)oxane-3, 4-diol; CAS Registry No. 56038-13-2) in carbonated and still beverages at the proposed European regulatory limits. For still beverages, a portion of the sample was diluted with methanol-water. For carbonated beverages, a portion of the sample was degassed in an ultrasonic bath before dilution. Turbid beverages were filtered after dilution through an HPLC syringe filter. The separation of sucralose was performed by direct application on amino-bonded (NH2) silica gel HPTLC plates (no cleanup needed) with the mobile phase acetonitrile-water. Sucralose was determined after reagent-free derivatization at 190 degrees C; it was quantified by measurements of both UV absorption and fluorescence. The samples, both spiked and containing sucralose, were sent to 14 laboratories in five different countries. Test portions of a sample found to contain no sucralose were spiked at levels of 30.5, 100.7, and 299 mg/L. Recoveries ranged from 104.3 to 124.6% and averaged 112% for determination by UV detection; recoveries ranged from 98.4 to 101.3% and averaged 99.9% for determination by fluorescence detection. On the basis of the results for spiked samples (blind duplicates at three levels), as well as sucralose-containing samples (blind duplicates at three levels and one split level), the values for the RSDr ranged from 10.3 to 31.4% for determinations by UV detection and from 8.9 to 15.9% for determinations by fluorescence detection. The values for the RSDR values ranged from 13.5 to 31.4% for determinations by UV detection and from 8.9 to 20.7% for determinations by fluorescence detection.
We report improved separation of the highly toxic contact herbicides paraquat, diquat, difenzoquat, mepiquat, and chloromequat by HPTLC. Quantification was based on a new derivatization reaction using sodium tetraphenylborate. Measurements were in the wavelength range from 440 to 480 nm or from 440 to 590 nm. An LED emitting very intense light at 365 nm was used for excitation. The quantification limits of paraquat and diquat in water, using improved solid-phase extraction, was in the low ng L −1 range. The linear range covered more than two orders of magnitude. Recovery was investigated for all the compounds, and was insufficient, ranging from 11 to 92%, but the method is inexpensive, rapid, and works reliably.
A diode array HPTLC method for dequalinium chloride in pharmaceutical preparations is presented. For separation a Nano TLC silica gel plate (Merck) is used with the mobile phase methanol-7.8% aqueous NH(4)(+)CH(3)COO(-) (17:3, v/v) over a distance of 6 cm. Dequalinium chloride shows an R(F) value of 0.58. Pure dequalinium chloride is measured in the wavelength range from 200 to 500 nm and shows several by-products, contour plot visualized in absorption, fluorescence and using the Kubelka-Munk transformation. Scanning of a single track in absorption and fluorescence measuring 600 spectra in the range from 200 to 1100 nm takes 30s. As a sample pre-treatment of an ointment it is simply dissolved in methanol and can be quantified in absorption from 315 to 340 nm. The same separation can also be quantified using fluorescence spectrometry in the range from 355 to 370 nm. A new staining method for dequalinium chloride, using sodium tetraphenyl borate/HCl in water allows a fluorescence quantification in the range from 445 to 485 nm. The linearity range of absorption and fluorescence measurements is from 10 to 2000 ng. Sugar-containing preparations like liquids or lozenges with a reduced sample pre-treatment can be reliably quantified only in fluorescence. The total for the quantification of an ointment sample (measuring four standards and five samples), including all sample pre-treatment steps takes less than 45 min!
BioPower
(2009)
Das Projekt BioPower ist eine Kooperation des Instituts für Angewandte Forschung (IAF) der Hochschule Offenburg mit dem Institut für Mikrosystemtechnik (IMTEK) der Universität Freiburg. Es handelt sich um den Versuch, die im Körper vorhandenen Energiequellen sozusagen direkt anzuzapfen, um sie für technische Zwecke zu nutzen. Von den vielen bestehenden Möglichkeiten konzentriert sich die Forschung hier auf die Nutzung der Glukose im Blut, die auch sonst als Energieträger zur Versorgung der Zellen im Körper dient.
Thin-layer chromatography is a rapid and reliable working method for quantification of mycotoxins which is suitable for checking EC legislation aflatoxin limits for dried figs without an RP-18 pre-column cleaning step. We describe normal-phase chromatography on silica gel plates with 2.4:0.05:0.1:0.05 ( v/v ) methyl t -butyl ether-water-methanol-cyclohexane as mobile phase and reversed-phase chromatography on RP-18 plates with methanol-4% aqueous ZnSO 4 solution-ethyl methyl ketone 15:15:3 ( v/v ) as mobile phase. Sample pretreatment was by modified QuEChERS (Quick, Easy, Cheap, Effective, Rugged, Safe) extraction with tetrahydrofuran or acetone. NaCl was used as QuEChERS salt. Response was a linear function of amount chromatographed in the ranges 3 to 100 pg per zone for aflatoxins B 2 and G 2 , 10 to 350 pg per zone for the aflatoxins B 1 and G 1 , and 0.25 to 2.5 ng per zone for ochratoxin A. Quantification limits for the aflatoxins were between 13 and 35 pg per zone (equivalent to 1.5 and 2.4 ppb, taking the pre-treatment procedure into account). Ochratoxin A was detectable with a limit of quantification of 970 pg per zone, corresponding to 56 ppb in the sample. Normal phase and RP-18 separations work rapidly, reliably, and at low cost. They are also suitable for checking the content of the mycotoxins patulin, penicillic acid, zearalenone, and deoxynivalenol.
Melamine (1,3,5-triazine-2,4,6-triamine or cyanuramide, C3H6N6) is a trimer of cyanamide, with a 1,3,5-triazine skeleton (Figure 3.5-1). The molecule contains 66% nitrogen by mass and, if mixed with resins, has fire retardant properties due to its release of nitrogen gas when burned or charred. The word melamine (from German) is a combination of the word melam (which is a distillation derivative of ammonium thiocyanate) and amine [1]. Melamine is also a metabolite of cyromazine, an insecticide in which the proton of an NH2-group is substituted by a cyclopropyl group.
A simple Method for quantifying Triazine Herbicides using Thin-Layer Chromatography and a CCD-Camera
(2010)
We present a video-densitometric quantification method for the triazine herbicides atraton, terbumeton, simazine, atrazine, and terbutylazine. Triazine herbicides were separated on silica gel using methyl-t-butyl ether, cyclohexane (1 + 1, v/v) as mobile phase. The quantification is based on a derivation reaction using chlorine and starch-iodine which forms red-brown triazine zones. Measurements were carried out using a 16 bit ST-1603ME CCD camera with 1.56 megapixel from Santa Barbara Instrument Group, Inc., Santa Barbara, USA. A white LED was used for illumination purposes. The range of linearity covers two magnitudes using the (1/R-1) expression data transformation. The signal-to-noise ratio increases directly linearly with the measurement time. The separation method is cheap, fast and reliable.
We present a video-densitometric quantification method for the pain killer known as diclofenac and ibuprofen. These non-steroidal anti-inflammatory drugs were separated on cyanopropyl bonded plates using CH2Cl2, methanol, cyclohexane (95 + 5 + 40, v/v) as mobile phase. The quantification is based on a bio-effective-linked analysis using Vibrio fisheri bacteria. Within 10 min a CCD-camera registered the white light of the light-emitting bacteria. Diclofenac and ibuprofen effectively suppressed the bacterial light emission which can be used for quantification within a linear range of 10 to 2000 ng. The detection limit for ibuprofen is 20 ng and the limit of quantification 26 ng per zone. Measurements were carried out using a 16-bit ST-1603ME CCD camera with 1.56 megapixels (from Santa Barbara Instrument Group, Inc., Santa Barbara, USA). The range of linearity covers more than two magnitudes because the extended Kubelka-Munk expression is used for data transformation. The separation method is inexpensive, fast, and reliable.
We will present the first example of a two-dimensional scanned TLC-plate, measured by use of a diode-array scanner. A spatial resolution of 250 µm was achieved on plate. The system provides real 2D fluorescence and absorption spectra in the wavelength-range from 190 to 1000 nm with a spectral resolution of greater than 1 nm. A mixture of 12 sulphonamides was separated by using a cyanopropyl-coated silica gel plate (Merck, 1.16464) with the solvent mix of methyl tert-butyl ether-methanol-dichloromethane-cyclohexane-NH3 (25%) (48:2:2:1:1, v/v) in the first and with a mixture of water-acetonitrile-dioxane-ethanol (8:2:1:1, v/v) in the second direction. Both developments were carried out over a distance of 70 mm. A separation number (spot capacity) of 259 was calculated. We discussed a new formula for its calculation in 2D-TLC separations. The drawback of this method is that measuring a 2D-TLC plate needs more than 3 h measurement time.
Die Weltwirtschaftskrise 2008 hat mit ihrer zeitweisen Verknappung von Acetonitril eindringlich gezeigt, dass man nicht nur auf eine einzige chromatographische Methode setzten sollte. Genau dies wird aber im Augenblick getan, denn Industrie und Forschung setzen mehrheitlich auf die High Performance Liquid Chromatography (HPLC) als die Trennmethode ihrer Wahl. Für viele Anwendungen in der Pharmazie, in der Umweltanalytik, der Lebensmittelanalytik, aber auch in der Inprozesskontrolle gibt es mit der Dünnschichtchromatografie eine Alternative.
We present a video-densitometric quantification method for the pain killer known as diclofenac and ibuprofen. These non-steroidal anti-inflammatory drugs were separated on cyanopropyl bonded plates using CH2Cl2, methanol, cyclohexane (95+5+40, v/v) as mobile phase. The quantification is based on a bio-effective-linked analysis using vibrio fischeri bacteria. Within 10 minutes a CCD-camera registers the white light of the light-emitting bacteria. Diclofenac and ibuprofen effectively suppress the bacterial light emission which can be used for quantification within a linear range of 10 to 2000 ng. The detection limit for ibuprofen is 20 ng and the limit of quantification 26 ng per zone. Measurements were carried out using a 16-bit ST-1603ME CCD camera with 1.56 megapixels [from Santa Barbara Instrument Group, Inc., Santa Barbara, USA]. The range of linearity covers more than two magnitudes because the extended Kubelka-Munk expression is used for data transformation [1]. The separation method is inexpensive, fast and reliable. Ibuprofen is named after its chemical description: iso-butyl-propanoic phenolic acid. Both pain killers are world-widein use and both substances are stable in aqueous solution. Both substances are mainly excreted in the urine.
Wir präsentieren die weltweit erste Auswertung einer zweidimensional entwickelten HPTLC-Platte (2D-HPTLC) mit Hilfe eines Diodenarray Scanners. Das System erreicht eine räumliche Plattenauflösung von 250 µm. Es können Absorptions- und Fluoreszenzspektren im Wellenlängenbereich von 190 bis 1000 nm mit einer spektralen Auflösung von besser als 1 nm gemessen werden. Eine Trennzahl von 259 wurde erreicht. Damit zeigt die Methode bessere Trenneigenschaften als die meisten HPLC-Systeme. Der Nachteil der 2D-Auswertung ist der hohe Zeitbedarf von über 3 Stunden für eine Plattenmessung.
Limits of quantification of some neonicotinoid insecticides measured by thin-layer chromatography
(2012)
A simple method to quantify the neonicotinoid insecticides nitenpyram, thiamethoxam, acetamiprid, imidacloprid, thiacloprid and clothianidin directly on an HPTLC-plate is presented. As stationary phase silica gel 60 RP-18WF254 s plates were used and a mixture of methyl-t-butyl ether, 2-butanone, NH3 (25%) (5 + 2+0.1, v/v) was used as solvent. All neonicotinoid insecticides show light absorptions below 300 nm. The calculated limits of quantification (LOQ) by UV-detection are in the range from 12 ng to 26 ng on plate depending on the different insecticides.Nitenpyram can be stained using fast blue salt B, forming red zones. The observed LOQ is 25 ng on plate. Acetamiprid can be specifically stained using phenylglyoxylic acid forming a yellow/green fluorescent compound. The LOQ is 52 ng per spot.The compounds thiamethoxam, acetamiprid, thiacloprid and clothianidin can be transformed into blue fluorescing zones, using a relatively new staining solution. This consists of tetraphenylborate and HCl. This is the first publication mentioning that neonicotinoids undergo this reaction. The calculated limits of quantification are in the range from 10 ng to 27 ng on plate.A simple pre-treatment procedure using an acetonitrile extraction and a Chromabond SiOH clean up procedure leads to overall LOQs for bee samples of 48 to 108 µg/Kg. The method can be used to measure neonicotinoid contaminations of bees.
Improved separation of highly toxic contact herbicides paraquat (1,1′-dimethyl-4-4′-bipyridinium), diquat (6,7-dihydrodipyridol[ 1,2-a:2′,1′-c]pyrazine-5,8-di-ium), difenzoquat (1,2-dimethyl-3,5-diphenyl-1H-pyrazolium-methyl sulfate), mepiquat (1,1-dimethyl-piperidinium), and chloromequat (2-chloroethyltrimethylammonium) were presented by high-performance thin-layer chromatography (HPTLC). The quantification is based on a derivatization reaction, using sodium tetraphenylborate. Measurements were made in the wavelength range from 500 to 535 nm, using a light-emitting diode (LED) for excitation purposes, which emits very dense light at 365 nm. For calculations, a new theory of standard addition method was used, thus leading to a minimal error if exactly the same amount of sample content is added as a standard. The method provides a fast and inexpensive approach to quantification of the five most important quats used for plant protection purposes. The method works reliably because it takes into account losses during pre-treatment procedure. The method meets the European legislation limits for paraquat and diquat in drinking water according to United States Environmental Protection Agency (US EPA) method 549.2 which are 680 ng L−1 for paraquat and 720 ng L−1 for diquat. The method of standard addition in planar chromatography can be beneficially used to reduce systematic errors. Although recovery rates of 33.7% to 65.2% are observed, calculated contents according to the method of standard addition lie between 69% and 127% of the theoretical amounts.