Refine
Year of publication
- 2012 (194) (remove)
Document Type
- Conference Proceeding (42)
- Contribution to a Periodical (35)
- Article (unreviewed) (22)
- Article (reviewed) (19)
- Other (19)
- Part of a Book (16)
- Bachelor Thesis (13)
- Book (10)
- Master's Thesis (7)
- Patent (4)
Conference Type
- Konferenzartikel (30)
- Konferenz-Abstract (8)
- Konferenzband (2)
- Konferenz-Poster (1)
- Sonstiges (1)
Keywords
- Adsorption (5)
- HTML 5.0 (4)
- Metallorganisches Netzwerk (4)
- E-Learning (3)
- JavaScript (3)
- Monitoring (3)
- Analyse (2)
- Dünnschichtchromatographie (2)
- Finite-Elemente-Methode (2)
- HTML (2)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (51)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (51)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (41)
- Zentrale Einrichtungen (26)
- Fakultät Wirtschaft (W) (24)
- INES - Institut für nachhaltige Energiesysteme (7)
- CRT - Campus Research & Transfer (2)
- WLRI - Work-Life Robotics Institute (2)
- Rektorat/Verwaltung (1)
Open Access
- Open Access (83)
- Closed Access (61)
- Closed (11)
- Bronze (10)
The Humboldt digital library (HDL) represents an innovative system to access the works and legacy of Alexander von Humboldt in a digital form on the Internet (www.avhumboldt.net). It contributes to the key question about how to present interconnected data in an appropriate form using information technologies. The HDL has been created as a dynamic digital library with the capability of connecting multilingual and multimedia data from diverse online archives. Humboldt’s volumes have become available, but beyond that any relevant information related to the observations of Humboldt, even outside the works can become immediately accessible. This makes it possible to recognize natural changes and compare Humboldt’s descriptions with recent situations. The technology we have developed addresses the issues of sustainability and makes it possible to detect changes in the environment since the time of Humboldt’s observations.
The newly synthesized Zn4O-based MOF 3∞[Zn4(μ4-O){(Metrz-pba)2mPh}3]·8 DMF (1·8 DMF) of rare tungsten carbide (acs) topology exhibits a porosity of 43% and remarkably high thermal stability up to 430 °C. Single crystal X-ray structure analyses could be performed using as-synthesized as well as desolvated crystals. Besides the solvothermal synthesis of single crystals a scalable synthesis of microcrystalline material of the MOF is reported. Combined TG-MS and solid state NMR measurements reveal the presence of mobile DMF molecules in the pore system of the framework. Adsorption measurements confirm that the pore structure is fully accessible for nitrogen molecules at 77 K. The adsorptive pore volume of 0.41 cm3 g−1 correlates well with the pore volume of 0.43 cm3 g−1 estimated from the single crystal structure.
Die immer weitreichenderen Anwendungen des Smart Metering und des Smart Grid stellen immer höhere Anforderungen an Kommunikationstechnologien, die die Zielkonflikte aus Echtzeitfähige, Stabilität, Kosten und Energieeffizienz möglichst anwendungsoptimiert und auf einem immer höheren Niveau lösen. Insbesondere im Bereich der so genannten Primärkommunikation zwischen einem Sensor- oder Aktorknoten und einem Datensammler mit Gatewayfunktionalität konnten in den vergangenen Jahren wesentliche Fortschritte erzielt werden. Zu nennen sind hierbei insbesondere die Aktivitäten der ZigBee Alliance rund um den offenen Spezifikationsprozess des ZigBee Smart Energy Profiles (SEP) und der OMS-Gruppe beim ZVEI, die auf dem Wireless M-Bus nach EN13757-4 aufbauen, der sich seinerseits lebhaft und zielgerichtet weiter entwickelt. Der Beitrag diskutiert die vorhandenen Einschränkungen und die verfügbaren Lösungsansätze. Er illustriert diese anhand einiger öffentlich geförderter Projekte, an denen das Team des Autors beteiligt ist.
Es sollte in dieser Schrift untersucht werden, inwieweit bei Änderungen im Bereich der Planung, Durchführung und Auswertung von klinischen Arzneimittelprüfungen die Bewertung mit wissenschaftlichen oder politischen Begründungen erfolgt und inwieweit wissenschaftliche Regeln für politische Zwecke genutzt werden.
The invention relates to a container (1) for a liquid medium (3), in particular a blood bag, comprising a flexible outer wall (5) and a device (13) connected to the container (1) for acquiring and/or storing data. According to the invention, the device (13) for acquiring and/or storing data is arranged within the flexible outer wall (5), wherein positioning means (15) are provided which hold the device (13) for acquiring and/or storing data in a floating manner in the liquid medium when the container (1) is filled with said liquid medium (3), and wherein the device (13) or the device (13) and the positioning means (15) are designed such that the mass of liquid medium (3) which is displaced in each case is essentially equal to the mass of the device (13) or to the mass of the device (13) and the positioning means (15).
Die Erfindung betrifft ein Behältnis (1) für ein flüssiges Medium (3), insbesondere Blutbeutel, mit einer flexiblen Außenwandung (5) und einer mit dem Behältnis (1) verbundenen Vorrichtung (13) zur Erfassung und/oder Speicherung von Daten. Erfindungsgemäß ist die Vorrichtung (13) zur Erfassung und/oder Speicherung von Daten innerhalb der flexiblen Außenwandung (5) angeordnet, wobei Positionierungsmittel (15) vorgesehen sind, welche die Vorrichtung (13) zur Erfassung und/oder Speicherung von Daten bei mit dem flüssigen Medium (3) gefüllten Behältnis (1) schwimmend im flüssigen Medium (3) halten, und wobei die Vorrichtung (13) oder die Vorrichtung (13) und die Positionierungsmittel (15) so ausgebildet sind, dass die jeweils verdrängte Masse von flüssigem Medium (3) im Wesentlichen gleich der Masse der Vorrichtung (13) oder der Masse der Vorrichtung (13) und der Positionierungsmittel (15) ist.
We will present the first example of a two-dimensional scanned TLC-plate, measured by use of a diode-array scanner. A spatial resolution of 250 µm was achieved on plate. The system provides real 2D fluorescence and absorption spectra in the wavelength-range from 190 to 1000 nm with a spectral resolution of greater than 1 nm. A mixture of 12 sulphonamides was separated by using a cyanopropyl-coated silica gel plate (Merck, 1.16464) with the solvent mix of methyl tert-butyl ether-methanol-dichloromethane-cyclohexane-NH3 (25%) (48:2:2:1:1, v/v) in the first and with a mixture of water-acetonitrile-dioxane-ethanol (8:2:1:1, v/v) in the second direction. Both developments were carried out over a distance of 70 mm. A separation number (spot capacity) of 259 was calculated. We discussed a new formula for its calculation in 2D-TLC separations. The drawback of this method is that measuring a 2D-TLC plate needs more than 3 h measurement time.
Die vorliegende Erfindung betrifft eine Messchraube zur Ermittlung von Schraubenbelastungen sowie ein Verfahren zu deren Herstellung. Die Messschraube umfasst mindestens zwei Dehnungsmesssensoren, die so im Schraubenschaft angeordnet und dehnungskinematisch mit dem Schraubenschaft gekoppelt sind, dass sie Dehnungswerte im Schraubenschaft erfassen, aus denenüber konstitutive Materialgesetze Belastungen in mehr als einer Achse im oberen freien Schaftbereich bestimmt werden können. Durch Möglichkeit der Bestimmung mehrachsiger Belastungen lassen sich Schrauben sachgerechter auslegen, so dass die Gefahr von Schraubenbrüchen reduziert wird.
Seit den ersten Projekten der 90er Jahre arbeiten Hochschulen daran, geeignete Servicestrukturen für E-Learning zu etablieren, die die erforderliche technische, didaktische und organisatorische Unterstützung hochschulweit zur Verfügung stellen. Ging es zunächst darum, Services überhaupt dauerhaft zu sichern, steht heute die Frage des „wie“ im Vordergrund. Dabei wird am Bereich E-Learning ein eigentlich viel allgemeineres Problem deutlich: Die bisher überwiegende Organisation der Hochschule nach funktionellen Einheiten stößt an ihre Grenzen. Wir schlagen eine stärker prozessorientierte Sichtweise vor, analog zu Entwicklungen bei der Organisation von Unternehmen.
The following paper presents the results of a feasibility study about Bluetooth Low Energy (BLE) based wireless sensors. The development of industrial wireless sensors leads to important demands for the wireless technologies like a low energy consumption and a resource saving simple protocol stack. Bluetooth Low Energy (BLE) is a rather new wireless standard which will completely fulfill these fundamental requirements. A self-designed BLE sensor system has been used to explore the common applicability of BLE for wireless sensor systems. The evaluation results of various analyses with the BLE sensor system are now presented in this paper.
Die Erfindung betrifft ein Behältnis (1) für ein flüssiges Medium (3), insbesondere Blutbeutel, mit einer flexiblen Außenwandung (5) und einer mit dem Behältnis (1) verbundenen Vorrichtung (13) zur Erfassung und/oder Speicherung von Daten. Erfindungsgemäß ist die Vorrichtung (13) zur Erfassung und/oder Speicherung von Daten innerhalb der flexiblen Außenwandung (5) angeordnet, wobei Positionierungsmittel (15) vorgesehen sind, welche die Vorrichtung (13) zur Erfassung und/oder Speicherung von Daten bei mit dem flüssigen Medium (3) gefüllten Behältnis (1) schwimmend im flüssigen Medium (3) halten, und wobei die Vorrichtung (13) oder die Vorrichtung (13) und die Positionierungsmittel (15) so ausgebildet sind, dass die jeweils verdrängte Masse von flüssigem Medium (3) im Wesentlichen gleich der Masse der Vorrichtung (13) oder der Masse der Vorrichtung (13) und der Positionierungsmittel (15) ist.
This paper describes the magmaOffenburg 3D simulation team trying to qualify for RoboCup 2012. While last year’s TDP focused on the tool set created for 3D simulation and the support for heterogeneous robot models, this year we focus on the different ways how robot behavior can be defined in the magmaOffenburg framework and how those behaviors can be improved by learning.
Experiences with a telecare platform integration of ZigBee sensors into a middleware platform
(2012)
Die Weltwirtschaftskrise 2008 hat mit ihrer zeitweisen Verknappung von Acetonitril eindringlich gezeigt, dass man nicht nur auf eine einzige chromatographische Methode setzten sollte. Genau dies wird aber im Augenblick getan, denn Industrie und Forschung setzen mehrheitlich auf die High Performance Liquid Chromatography (HPLC) als die Trennmethode ihrer Wahl. Für viele Anwendungen in der Pharmazie, in der Umweltanalytik, der Lebensmittelanalytik, aber auch in der Inprozesskontrolle gibt es mit der Dünnschichtchromatografie eine Alternative.
In cardiac resynchronization therapy (CRT) for heart failure, individualization of the AV delay is essential to improve hemodynamics and to minimize non-responder rate. In patients in sinus rhythm having additional disposition to bradycardia, optimization is necessary for both situations, atrial sensing and pacing. Therefore, echo-optimization is the goldstandard but time consuming. Unfortunately, it depends on the particular CRT systems parameter set if the resulting individually optimal AV delays can be programmed or not. Some CRT systems provide a set of AV delays for DDD operation combined with a set of the pace-sense-compensation to optimize the AV delay in DDD and VDD operation. The pace-sense-compensation (PSC) can be defined by the difference of implant-related interatrial conduction intervals in DDD and VDD operation measured in the esophageal left atrial electrogram. In a cohort of 96 CRT patients we found mean PSC of 59-35ms ranging between 0-143ms. As a consequence, allowing 10ms tolerance, AVD optimization is completely impossible in one of the two modes, VDD or DDD operation, in 34 (35%) or 5 (5%) patients with implants restricting the PSC range to 60ms or 100ms, respectively. Thus, we propose companies to provide CRT systems with programmable pace-sense- compensation between 0ms and 150ms.
Responder-rate in cardiac resynchronization therapy (CRT) of patients in sinus rhythm (SR) or atrial fibrillation (AF) mainly depends on accurat selection, optimal position of the left ventricular electrode and individualization of hemodynamical parameters of the implanted biventricular pacing system during follow-up. High resolution esophageal left heart electrocardiography offers a quick and semi-invasive approach to the electrical activity of left atrium and left ventricle. It was used in 62 heart failure patients in sinus rhythm and 11 in atrial fibrillation after implantation of CRT systems to compare the semi-invasive interventricular conduction delay (IVCDE) with QRS width. In all of the patients, guideline decision for CRT was linked with IVCDE of about 40ms and up. From logical point of view, IVCDE provides the minimal target interval for the left ventricular electrode placement in order to exclude non-responders. Esophageal measurement of interatrial conduction intervals in VDD and DDD pacing was utilized to individualize the AV delay and to exclude adverse hemodynamic effects.
The applicability of finite elements for molecular dynamic simulations depends on both the structure’s dimensions and the underlying force field type. Shell and continuum elements describe molecular structures only in an average sense, which is why they are not subject of this paper. In contrast, truss and beam elements are potentially attractive candidates when it comes to accurately reproducing the atomic interactions. However, special considerations are required for force fields that use not only two-body, but also multi-body potentials. For the example of bending and torsion energies it is shown how standard beam element models have to be extended to be equivalent to classical molecular dynamic simulations.
Geleitwort
(2012)
Ist Cloud datenschutzwidrig?
(2012)
BFH "Umsatzsteuer bei ebay"
(2012)
BGH "Postfachanschrift"
(2012)
EuGH "Meister"
(2012)
BGH Insertionsofferte
(2012)
Das Ziel dieses Aufsatzes besteht darin, einen systematischen Überblick über den staatlichen Regulierungsbedarf in der Verkehrswirtschaft zu geben. Aus netzökonomischer Sicht ist eine konzeptionelle Unterscheidung der einzelnen Wertschöpfungsstufen (Netzebenen) in Verkehrssystemen von grundlegender Bedeutung, um zu einer ökonomisch fundierten Rollenverteilung zwischen Markt und Staat in der Verkehrswirtschaft zu kommen. Was der Markt auf der Ebene der Verkehrsdienste leisten kann, haben z.B. die Marktöffnungen im Luftverkehr und im Straßengüterverkehr eindrucksvoll gezeigt. Die Ebene der Verkehrssteuerungssysteme ist vor allem für die Sicherheit von Verkehrssystemen von großer Bedeutung. Auf der Ebene der Verkehrsinfrastrukturen ist das Marktmachtproblem zentral. Das Marktmachtproblem verschärft auch das staatliche Beschaffungsproblem bei der Bestellung defizitärer Verkehrsinfrastrukturen. Es fällt schwer, eine davon unabhängige Begründung für eine staatliche Planung der Verkehrsinfrastrukturnetze zu geben. Auf der Ebene der natürlichen Ressourcen erstreckt sich der staatliche Regulierungsbedarf teilweise weit über die Grenzen des Verkehrssektors hinaus, z.B. in der Klimapolitik oder bei der Raumplanung. Eine sektorsymmetrische Umweltpolitik und eine sektorsymmetrische Raumordnungspolitik wären die Voraussetzungen dafür, dass die Verkehrspolitik sich ganz auf ihre sektorspezifischen Aufgaben in der Verkehrswirtschaft konzentrieren kann.
Capture threshold (CT) for transesophageal left atrial (LA) pacing (TLAP) and transesophageal left ventricular (LV) pacing (TLVP) with conventional cylindrical electrodes (CE) are higher than TLAP feeling threshold (FT). Purpose of the study was to evaluate focused TLAP CT and FT for supraventricular tachycardia (SVT) initiation and focused TLVP CT for cardiac resynchronisation therapy (CRT) simulation.
Methods: SVT initiation in patients (P) with palpitations (n=49, age 47 ± 17 years) was analysed during spontaneous rhythm and during focused bipolar TLAP with atrial constant current stimulus output, distal CE and three or seven 6 mm hemispherical electrodes (HE) (TO, Osypka AG, Rheinfelden, Germany). CRT simulation in heart failure P (n=75, age 62 ± 11 years) was evaluated by focused bipolar TLAP and/or TLVP with ventricular constant voltage stimulus output and different pacing mode.
Results: Focused electrical pacing field between CE and HE (n=28) allowed low threshold TLAP with 8.0 ± 2.6 mA CT at 9.9 ms stimulus duration (SD) which was lower than 9.2 ± 4.5 mA FT at 9.9 ms SD. Focused electrical pacing field between HE and HE (n=21) allowed low threshold TLAP with 8.1 ± 2.2 mA CT at 9.9 ms SD which was lower than 9.8 ± 5.0 mA FT at 9.9 ms SD. SVT initiation by programmed AAI TLAP was possible in 23 P and not possible in 26 P. CRT simulation was evaluated with TLAP and TLVP with VAT, D00 and V00 pacing mode and 95.5 ± 10.9 V TLVP CT at 4.0 ms SD.
Conclusions: Programmed focused AAI TLAP allowed initiation of SVT with very low CT and high FT and focused electrical pacing field between CE-HE and HE-HE.CRT simulation with focused TLAP and/or TLVP with VAT, D00 and V00 pacing mode may be a useful technique to detect responders to CRT.
Cardiac resynchronization therapy (CRT) with biventricular (BV) pacing is an established therapy in approximately two-thirds of symptomatic heart failure (HF) patients (P) with left bundle branch block (LBBB). The aim of this study was to evaluate left atrial (LA) conduction delay (LACD) and left ventricular (LV) conduction delay (LVCD) using pre-implantational transesophageal electrocardiography (ECG) in sinus rhythm (SR) CRT responder (R) and non-responder (NR).
Methods: SR HF P (n=52, age 63.6±10.4 years; 6 females, 46 males) with New York Heart Association (NYHA) class 3.0±0.2, 24.4±7.1 % LV ejection fraction and 171.2±37.6 ms QRS duration (QRSD) were measured by bipolar filtered transesophageal LA and LV ECG recording with hemispherical electrodes (HE) TO catheter (Osypka AG, Rheinfelden, Germany). LACD was measured between onset of P-wave in the surface ECG and onset of LA deflection in the LA ECG. LVCD was measured between onset of QRS in the surface ECG and onset of LV deflection in the LV ECG.
Results: There were 78.8 % SR CRT R (n=41) with 171.2±36.9 ms QRSD, 73.3±25.7 ms LACD, 80.0±24.0 ms LVCD and 2.3±0.5 QRSD-LVCD-ratio. SR CRT R QRSD correlated with LACD (r=0.688, P<0.001) and LVCD (r=0.699, P<0.001). There were 21.2 % SR CRT NR (n=11) with 153.4±22.4 ms QRSD (P=0.133), 69.8±24.8 ms LACD (n=6, P=0.767), 54.2±31.0 ms LVCD (P<0.0046) and 3.9±2.5 QRSD-LVCD-ratio (P<0.001). SR CRT NR QRSD not corre-lated with IACD (r=-0.218, P=0.678) and IVCD (r=0.042, P=0.903). During a 22.8±21.3 month CRT follow-up, the CRT R NYHA class improved from 3.1±0.3 to 1.9±0.3 (P<0.001). In CRT NR, NYHA class not improved (2.9±0.4 to 2.9±0.2, P=1) during 11.2±9.8 months BV pacing.
Conclusions: Transesophageal LA and LV ECG with HE can be utilized to analyse LACD and LVCD in HF P. Pre-implantational LVCD and QRSD-LVCD-ratio may be additional useful parameters to improve P selection for SR CRT.
Machine-to-machine communication is continuously extending to new application fields. Especially smart metering has the potential to become the first really large-scale M2M application. Although in the future distributed meter devices will be mainly connected via dedicated primary communication protocols, like ZigBee, Wireless
M-Bus or alike, a major percentage of all meters will be connected via point to point communication using GPRS or UMTS platforms. Thus, such meter devices have to be extremely cost and energy efficient, especially if the devices are battery based and powered several years by a single battery. This paper presents the development of an automated measurement unit for power and time, thus energy characteristics can be recorded. The measurement unit includes a hardware platform for the device
under test (DUT) and a database based software environment for a smooth execution and analysis of the measurements.
The research project Ko-TAG [2], as part of the research initiative Ko-FAS [1], funded by the German Ministry of Economics and Technologies (BMWi), deals with the development of a wireless cooperative sensor system that shall pro-vide a benefit to current driver assistance systems (DAS) and traffic safety applications (TSA). The system’s primary function is the localization of vulnerable road users (VRU) e.g. pedestrians and powered two-wheelers, using communication signals, but can also serve as pre-crash (surround) safety system among vehicles. The main difference of this project, compared to previous ones that dealt with this topic, e.g. the AMULETT project, is an underlying FPGA based Hardware-Software co-design. The platform drives a real-time capable communication protocol that enables highly scalable network topologies fulfilling the hard real-time requirements of the single localization processes. Additionally it allows the exchange of further data (e.g. sensor data) to support the accident pre-diction process and the channel arbitration, and thus supports true cooperative sensing. This paper gives an overview of the project’s current system design as well as of the implementations of the key HDL entities supporting the software parts of the communication protocol. Furthermore, an approach for the dynamic reconfiguration of the devices is described, which provides several topology setups using a single PCB design.