Refine
Year of publication
- 2004 (3) (remove)
Document Type
- Article (reviewed) (3) (remove)
Language
- English (3)
Has Fulltext
- no (3) (remove)
Is part of the Bibliography
- yes (3)
Keywords
- Ausgleich (1)
- Diode-array detector (1)
- Elektronik (1)
- Fluorescence measurements (1)
- Flupirtine (1)
- Konzentration (1)
- Kubelka-Munk theory (1)
- Metallgitter (1)
- Übertragung (1)
Institute
Open Access
- Closed (1)
- Closed Access (1)
- Open Access (1)
Experimental and theoretical investigations of the time of equalization of the concentration of an impurity in a rectangular flow‐type chamber have been carried out. It has been shown that the process of equalization of the concentration with time is exponential in character. The characteristic equalization time has been computed using the theory of turbulent diffusion. Theoretical results describe experimental regularities with an accuracy of about 10%. The value of the coefficient of turbulent diffusion for different configurations of flows in the chamber has been obtained from a comparison of experimental and calculated results.
Lattice vibrations and electronic transitions in the rare-earth metals: Praseodymium under pressure
(2004)
Praseodymium was investigated by Raman spectroscopy under pressure. A negative pressure shift of the E2g mode is observed in the dhcp phase, which indicates that the initial structural sequence hcp→Sm−type→dhcp→fcc as a whole in the regular lanthanides is associated with a softening of this mode. The pressure response of the phonon modes, observed in the monoclinic and α-uranium phases, where 4f bonding becomes important, is characteristic for anisotropic bonding properties.
A new formula is presented for transforming fluorescence measurements in accordance with Kubelka-Munk theory. The fluorescence signals, the absorption signals, and data from a selected reference are combined in one expression. Only diode-array techniques can measure all the required data simultaneously to linearize fluorescence data correctly. To prove the new theory HPTLC quantification of the analgesic flupirtine was performed over the mass range 300 to 5000 ng per spot. The fluorescence calibration curve was linear over the whole range. The transformation of fluorescence measurements into linear mass-dependent data extends the technique of in-situ fluorescence analysis to the high concentration range. It also extends Kubelka-Munk theory from absorption to fluorescence analysis. The results presented also emphasize the importance of Kubelka-Munk theory for in-situ measurements in scattering media, especially in planar chromatography.