Refine
Year of publication
- 2014 (155) (remove)
Document Type
- Article (unreviewed) (51)
- Conference Proceeding (38)
- Article (reviewed) (32)
- Part of a Book (16)
- Book (13)
- Patent (3)
- Contribution to a Periodical (1)
- Other (1)
Has Fulltext
- no (155) (remove)
Keywords
- Intelligentes Stromnetz (5)
- Kommunikation (5)
- Lithiumbatterie (4)
- Produktentwicklung (4)
- Produktion (4)
- Elektrolyt (3)
- Herzkrankheit (3)
- Management (3)
- Mathematik (3)
- Netzwerk (3)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (79)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (36)
- Fakultät Medien und Informationswesen (M+I) (24)
- Fakultät Betriebswirtschaft und Wirtschaftsingenieurwesen (B+W) (21)
- INES - Institut für Energiesystemtechnik (16)
- IUAS - Institute for Unmanned Aerial Systems (4)
- Zentrale Einrichtungen (4)
Diese Fallstudien sind im Rahmen der Vorlesung "Integrationsseminar" von Bachelorstudenten/-innen des 5. Semesters an der DHBW Mannheim erarbeitet worden. Es handelt sich bei diesen Fallstudien ausschließlich um Unternehmen, die einen Onlinehandel betreiben. Jede Fallstudie beginnt mit der Beschreibung des Beispielunternehmens, deren Entwicklung und Ausrichtung. Anschließend werden die Marktsituation, sowie die Stärken und Schwächen dargestellt. Die Handlungsempfehlung und das Fazit fassen die Schwerpunkte zusammen und die abschließenden Arbeitsfragen können für eine weitere Bearbeitung verwendet werden.
Diese Fallstudien sind im Rahmen der Vorlesung "Integrationsseminar" von Bachelorstudenten/-innen des 5. Semesters an der DHBW Mannheim erarbeitet worden.Es handelt sich bei diesen Fallstudien ausschließlich um Unternehmen, die einen Onlinehandel betreiben.Jede Fallstudie beginnt mit der Beschreibung des Beispielunternehmens, deren Entwicklung und Ausrichtung. Anschließend werden die Marktsituation, sowie die Stärken und Schwächen dargestellt. Das Fazit und eine Handlungsempfehlung fassen die Schwerpunkte zusammen und die abschließenden Arbeitsfragen können für eine weitere Bearbeitung verwendet werden.
This work describes a camera-based method for the calibration of optical See-Through Glasses (STGs). A new calibration technique is introduced for calibrating every single display pixel of the STGs in order to overcome the disadvantages of a parametric model. A non-parametric model compared to the parametric one has the advantage that it can also map arbitrary distortions. The new generation of STGs using waveguide-based displays [5] will have higher arbitrary distortions due to the characteristics of their optics. First tests show better accuracies than in previous works. By using cameras which are placed behind the displays of the STGs, no error prone user interaction is necessary. It is shown that a high accuracy tracking device is not necessary for a good calibration. A camera mounted rigidly on the STGs is used to find the relations between the system components. Furthermore, this work elaborates on the necessity of a second subsequent calibration step which adapts the STGs to a specific user. First tests prove the theory that this subsequent step is necessary.
A benchmark analysis of Long Range (LoRaTM) Communication at 2.45 Ghz for safety applications
(2014)
Die Kenntnis der Messunsicherheit verbessert die Aussagekraft von Einsatzhärtungstiefe-Messungen. Ausgehend von der Definition in der DIN EN ISO 2639:2002 wird unter Anwendung des „Guide to the Expression of Uncertainty in Measurement“ die Messunsicherheit abgeschätzt. Dazu werden die Einflüsse der Härteprüfung, der Positionierung der Prüfpunkte und der Probe berücksichtigt. Das Verfahren wird an zwei Beispielen angewendet: Zunächst werden die gemäß Norm zulässigen Toleranzen vollständig ausgenutzt, anschließend die Unsicherheit eines automatisierten Härteprüfers experimentell ermittelt. In beiden Fällen dominiert der Probeneinfluss das Ergebnis.
Eine neue Prozessidee zur Auftrennung racemischer Wirkstoffe unter Verwendung nanoskaliger AlO(OH)‐Hohlkugeln als Adsorbens und überkritischen Kohlenstoffdioxides (sc‐CO2) als Lösungsmittel wird vorgestellt. Zur Auslegung des Prozesses werden Untersuchungen zur Abscheidung der racemischen Wirkstoffe (RS)‐Flurbiprofen, (RS)‐Ibuprofen, (RS)‐Ketoprofen und den reinen Enantiomeren (R)‐Flurbiprofen, (S)‐Ibuprofen und (S)‐Ketoprofen an AlO(OH)‐Hohlkugeln präsentiert und bewertet. Zudem werden Adsorptionsdaten von gasförmigem CO2 an den Hohlkugeln und kommerziellen AlO(OH)‐Partikeln, die mit einer Magnetschwebewaage ermittelt wurden, verglichen. Abschließend werden erste Ergebnisse von orientierenden Versuchen zur Adsorption von racemischem Flurbiprofen aus sc‐CO2 an den Hohlkugeln vorgestellt.
Ansatzpunkte zur Verknüpfung von Wertmanagement und Wertemanagement aus Sicht der Führungspraxis
(2014)
Transcatheter aortiv valve implantation is a new safe strategy treatment for patients with symptomatic severe aortic stenosis and high operative risk. The aim of the study was to compare the pre-and post- muiscatheter aortiv valve implantation procedures to determine the atrioventricuktr conduction time as a potential predictor of permanent pacemaker therapy requirement after transcatheter aortiv valve implantation. The transcatheter aortiv valve implantation patients were divided into groups without pacemaker and with dual or single chamber pacemEtker with diffent atrioventrieular conduction time disturbance before and after transcatheter aortiv valve implantation. In heart failure, patients without permanent pacemaker therapy after transcatheter aortiv valve implantation, atrioventricular conduction time was prolonged after transcatheter aortiv valve implantation. In patients with permanent dual chamber pacemaker therapy after transcatheter aortiv valve implantation, atrioventricular conduction time was normalised with dual chaniber atrioventrieuku pacing mode. Atrioventricular conduction time may be a useful parameter to evaluate the risk of post-procedural atrioventricular conduction block and permanent pacemaker therapy in transcatheter north, valve implantation patients.
Automatisierte Tests für ein IEEE802.11p-kompatibles Kommunikations- und Lokalisierungssubsystem
(2014)
BAG "Elektronische Signatur"
(2014)
Besonderes Außensteuerrecht
(2014)
Several cloud schedulers have been proposed in the literature with different optimization goals such as reducing power consumption, reducing the overall operational costs or decreasing response times. A less common goal is to enhance the system security by applying specific scheduling decisions. The security risk of covert channels is known for quite some time, but is now back in the focus of research because of the multitenant nature of cloud computing and the co-residency of several per-tenant virtual machines on the same physical machine. Especially several cache covert channels have been identified that aim to bypass a cloud infrastructure's sandboxing mechanism. For instance, cache covert channels like the one proposed by Xu et. al. use the idealistic scenario with two alternately running colluding processes in different VMs accessing the cache to transfer bits by measuring cache access time. Therefore, in this paper we present a cascaded cloud scheduler coined C 3 -Sched aiming at mitigating the threat of a leakage of customers data via cache covert channels by preventing processes to access cache lines alternately. At the same time we aim at maintaining the cloud performance and minimizing the global scheduling overhead.
Für die Zahnwellenprofile nach DIN 5480 ist es schwierig, das polare Trägheitsmoment des geschwächten Querschnitts aus der Geometrie festzulegen. Dieses ist jedoch zur Berechnung der Nennspannung oder der Verdrehsteifigkeit erforderlich. Unterschiedliche Nennspannungsdefinitionen stehen dem Konstrukteur zur Verfügung. Diese können z.B. bei der Formzahldarstellung zu Missverständnissen führen. In der Praxis hilft man sich in der Weise, dass man dem durch die Formelemente (Keile, Zähne) geschwächten Querschnitt einen Kreis einbeschreibt und die Spannung einer Ersatzwelle mit dem Durchmesser dh1 dieses einbeschriebenen Kreises ermittelt. Die in der DIN 5466 vorhandene Näherungsgleichung zur Berechnung des Ersatzdurchmessers dh1 verzahnter Wellen geht auf Arbeiten von Nakazawa im Jahr 1951 [Nakazawa, Hajime: On the Torsion of the Spline Shafts. The Japan Society of Mechanical Engineers, 1951, S. 651-658 + S. 643-650, Tokyo Torizo Univers. 1951] und später auf [Schöpf, H.-J.: Festigkeitsuntersuchung an Zahnwellen-Verbindungen mit Spannungsoptik und Dauerschwingversuchen. Dissertation der TU München 1976] zurück. Mit diesem imaginären Durchmesser dh1 kann man das polare Flächenträgheitsmoment und Widerstandsmoment ermitteln. Die Ergebnisgenauigkeit dieser Näherungslösung ist für eine treffsichere Festigkeitsberechnung aus heutiger Sicht unbefriedigend. Ziel dieses Aufsatzes ist es, dem Anwender Möglichkeiten und Ergebnisse zur Verfügung zu stellen, die es ihm gestatten, das effektiv wirkende Widerstandsmoment für verzahnte Wellenprofile genauer zu bestimmen. Dabei wird der dafür notwendige Ersatzdurchmesser mit Hilfe von theoretischen Überlegungen und Programmtools (CAD, Matlab und Excel) für den gesamten nach DIN 5480 festgelegten Geometriebereich unter die Lupe genommen.
E-Bilanz
(2014)
Introduction: Despite lots of developments in the last years, radiofrequency ablation of rhythm diseases is a safe but still complex procedure that requires special experience and expertise of the physicians and biomedical engineers. Thus, there is a need of special trainings to become familiar with the different equipment and to explain several effects that can be observed during clinical routine.
Methods: The Offenburg University of Applied Sciences offers a biomedical engineering study path specialized in the fields of cardiology, electrophysiology and cardiac electronic implants. It`s Peter Osypka Institute for Pacing and Ablation provides teaching following the slogan “Learning by watching, touching and adjusting”. It conducts lots of trainings for students as well as young physicians interested in electrophysiology and radiofrequency ablation.
Results: In-vitro trainings will be provided using the Osypka HAT 200 and HAT300s, Stockert EPshuttle and SmartAblate system as well as the Boston EPT-1000XP and Maestro 3000 and the Radionics RFG-3E cardiac radio frequency ablation generators. All of them require different handling as well as special accessories like catheter connection cables or boxes and back plates. The participants will be trained in the setup of temperature, power and cut-off impedance dependent on different ablation catheters. Furthermore troubleshooting in hard- and software is part of the program. Performing procedures in pork or animal protein and using physiological saline solution to simulate the blood flow, they can study the influence of contact force and impedance on lesion geometry etc. and to avoid adverse effects like “plops”. Lots of catheter types are available: 4mm tip, 8mm standard and gold tip, open and closed irrigated tip ablation catheters of different companies. The experiments will be completed by measuring the lesion size dependent on the used catheter type and ablation settings.
Conclusion: In-vitro training in radiofrequency ablation is a challenge for biomedical engineering students and young physicians.