Refine
Year of publication
- 2016 (238) (remove)
Document Type
- Conference Proceeding (74)
- Article (reviewed) (52)
- Article (unreviewed) (44)
- Part of a Book (31)
- Book (17)
- Patent (9)
- Other (4)
- Report (4)
- Letter to Editor (2)
- Periodical Part (1)
Conference Type
- Konferenzartikel (60)
- Konferenz-Abstract (9)
- Sonstiges (6)
- Konferenz-Poster (1)
Has Fulltext
- no (238) (remove)
Is part of the Bibliography
- yes (238)
Keywords
- Digitalisierung (6)
- Eingebettetes System (5)
- Energieversorgung (5)
- Haustechnik (5)
- Management (5)
- Mathematik (5)
- Bildung (4)
- Messtechnik (4)
- Design (3)
- Dünnschichtchromatographie (3)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (94)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (63)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (48)
- Fakultät Wirtschaft (W) (35)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (20)
- INES - Institut für nachhaltige Energiesysteme (17)
- ACI - Affective and Cognitive Institute (4)
- POIM - Peter Osypka Institute of Medical Engineering (2)
- IfTI - Institute for Trade and Innovation (1)
- WLRI - Work-Life Robotics Institute (1)
Open Access
- Closed Access (58)
- Open Access (52)
- Bronze (6)
- Closed (5)
Dos and Don’ts im Dashboard-Design: Wie Eyetracking-Verfahren bei der Datenvisualisierung helfen
(2016)
Drehzahlzustandsregelung
(2016)
This paper presents the results of the idea generation experiment that repeats the study originally conducted at RMIT. In order to establish the influence that the experimental treatments make on the number and the breadth of solution ideas proposed by problem solvers with different knowledge levels, students from different years of study were recruited. Ninety students from the Offenburg University of Applied Sciences, Germany were divided into three groups. All students were asked to generate ideas on cleaning lime deposits from the inside of a water pipe and were given 16 minutes to record their individual ideas. Students of two experimental groups were shown some words for two minuted each. The Su-Field group was exposed to the eight fields of MATCEMIB. The Random Word group was shown eight random words every two minutes. The Su-Field group outperformed both the Control group and the Random Word group in the number of ideas generated. It was also found that the students from the Su-Field group proposed significantly broader solutions than the students from the Control and Random Word groups. The overall results of the experiment support the conclusions made by the RMIT researchers that simple ideation techniques can significantly improve idea generation and that the systematised Substance-Field Analysis is a suitable heuristic for engineering students.
Im vorliegenden Beitrag wird beschrieben, wie bereits entworfene Zustandsregler für proportional geregelte Systeme ohne Rechentotzeit auf einfache Art und Weise für Systeme mit Reglerintegratoren bzw. mit Rechentotzeit erweitert werden können. Das Ziel ist hierbei, den Aufwand zur Ermittlung der Reglermatrix zu reduzieren. Hierbei soll die bereits vorhandene, optimierte Regelkreisdynamik so wenig wie möglich verändert werden, wodurch bei Mehrgrößensystemen hinzukommende Freiheitsgrade sinnvoll festgelegt werden. Die Betrachtungen erfolgen für lineare zeitdiskrete Systeme und werden anhand eines Beispiels aus der elektrischen Antriebstechnik veranschaulicht.
Einsatz von Additive Manufacturing zur Darstellung von Simulationsergebnissen in der Blechumformung
(2016)
Background: Cardiac resynchronization therapy (CRT) is an established therapy for heart failure (HF) patients (P) with reduced left ventricular (LV) ejection fraction and electrical interventricular desynchronization, but not all P improved clinically. The aim of the study was to evaluate electrical interventricular delay (IVD) to LV delay (LVD) ratio in atrial fibrillation (AF) CRT responder (R) and non-responder (NR).
Methods: AF P (n = 18, age 60.6 ± 11.4 years, 1 female, 17 males) with HF New York Heart Association (NYHA) class 3.0 ± 0.2, 25.3 ± 5.9 % LV ejection fraction and 157.8 ± 24.4 ms QRS duration (QRSD) were measured by surface ECG and focused transesophageal bipolar LV ECG before implantation of CRT pacemaker (n = 2) or CRT defibrillator (n = 16). IVD was measured between onset of QRS in the surface ECG and onset of LV signal in the LV ECG. LVD was measured between onset and offset of LV signal in the LV ECG.
Results: Electrical ventricular desynchronization in AF CRT P were 61.9 ± 26.9ms IVD, 80.6 ± 24.3ms LVD, 0.85 ± 0.41 IVD-LVD-ratio (Figure), 3.12 ± 1.89 QRSD-IVD-ratio and 2.07 ± 0.47 QRSD-LVD-ratio. There were 72.2 % AF CRT R (n = 13) with 64.2 ± 24.6ms IVD and 77.8 ± 21.6ms LVD with Pearson correlation to 0.89 ± 0.39 IVD-LVD-ratio (r = 0.87, P < 0.01; r = -0.69, P < 0.01), 2.82 ± 1.32 QRSD-IVD-ratio (r = -0.76, P < 0.01; r = 0.67, P = 0.011) and 2.13 ± 0.46 QRSD-LVD-ratio (r = 0.57, P = 0.041; r = -0.85, P < 0.01). There were 27.8% AF CRT NR (n = 5) with 56.0 ± 34.5ms IVD and 87.8 ± 31.9ms LVD without correlation to 0.74 ± 0.48 IVD-LVD-ratio, 3.88 ± 2.98 QRSD-IVD-ratio and 1.90 ± 0.48 QRSD-LVD-ratio. During 15.3 ± 13.1 month CRT follow-up, the AF CRT R NYHA class improved from 3.0 ± 0.2 to 2.2 ± 0.3 (P < 0.001). During 18.8 ± 20.7 month CRT follow-up, the AF CRT NR NYHA class not improved from 3 to 3.3 ± 0.97.
Electrochemical impedance spectroscopy (EIS) is a widely-used diagnostic technique to characterize electrochemical processes. It is based on the dynamic analysis of two electrical observables, that is, current and voltage. Electrochemical cells with gaseous reactants or products (e.g., fuel cells, metal/air cells, electrolyzers) offer an additional observable, that is, the gas pressure. The dynamic coupling of current and/or voltage with gas pressure gives rise to a number of additional impedance definitions, for which we use the term electrochemical pressure impedance. It also gives rise to different experimental probing approaches. In this article we present a model-based study of electrochemical pressure impedance spectroscopy (EPIS). Possible quantifications and realizations of EPIS are discussed. The study of generic cell geometries consisting of gas reservoir, diffusion layer(s) and electrochemically active layer(s) reveals distinct spiral-shaped features in the Nyquist plot. Using the example of a sodium/oxygen (Na/O2) cell, the dynamic spatiotemporal behavior of the state variables is quantified and interpreted. Results are compared to first experimental EPIS measurements by Hartmann et al. [J. Phys. Chem. C118, 1461, 2014]. A sensitivity analysis highlights the properties of EPIS with respect to geometric, transport, and kinetic parameters. We demonstrate that EPIS is sensitive to transport parameters that are not well-accessible with standard EIS.
Elektronische Pille zur steuerbaren Abgabe einer Substanz in einem menschlichen oder tierischen Körper, (a) mit einem Gehäuse (3), in welchem die abzugebende Substanz (17) aufgenommen und in welchem eine Abgabeöffnung (47) zur Abgabe der Substanz (17) vorgesehen ist, wobei die Substanz (17) zur Abgabe aus dem Gehäuse (3) mit einem vorbestimmten Druck beaufschlagt ist, (b) mit einer elektronischen Steuereinheit (53, 59, 61, 63), und (c) mit einer im Verlauf eines Abgabepfades angeordneten Ventileinheit (33), welche von der Steuereinheit (53, 59, 61, 63) von einer Geschlossen- Stellung in eine Geöffnet-Stellung steuerbar ist und umgekehrt, (d) dadurch gekennzeichnet, (e) dass die Ventileinheit (33) eine von der elektronischen Steuereinheit (53, 59, 61, 63) ansteuerbare Heizeinheit (49) umfasst, (f) dass die Ventileinheit (33) ein Schaltelement (39) umfasst, welches in der Geschlossen-Stellung zumindest mit einem Teilbereich dichtend an einem Ventilsitz (37) der Ventileinheit (33) anliegt und welches von der Heizeinheit (49) beheizbar ist, (g) dass das Schaltelement (39) zwei temperaturabhängige stabile Schaltstellungen aufweist, welche durch eine Formänderung des Schaltelements (39) definiert sind, und (h) die Heizeinheit (49) an der dem Ventilsitz (37) abgewandten Seite des Schaltelements (39) angeordnet und integriert mit dem Schaltelement (39) ausgebildet ist (i) wobei die Steuereinheit (53, 59, 61, 63) zum Öffnen der Ventileinheit (33) die Heizeinheit (49) aktiviert, so dass das Schaltelement (39) bei Überschreiten einer Schwellentemperatur aus der Geschlossen-Stellung in die Geöffnet-Stellung geschaltet wird und (j) wobei die Steuereinheit (53, 59, 61, 63) zum Schließen der Ventileinheit (33) die Heizeinheit (49) deaktiviert, so dass das Schaltelement bei Unterschreiten einer Schwellentemperatur aus der Geöffnet-Stellung in die Geschlossen-Stellung schaltet.
eLetter zum Artikel "How hair can reveal a history" von Hanae Armitage & Nala Rogers, veröffentlicht in Science, Vol. 351, Issue 6278, Seite 1134 (doi.org/10.1126/science.351.6278.1134)
Empirische Untersuchungen zum visuellen Wahrnehmen beim Lesen und Verstehen technischer Zeichnungen
(2016)
Es wurden 49 Einzelpersonen aus dem Studiengang „Maschinenbau“ der Hochschule Offenburg bei der Lösungssuche für eine zeichnerische Aufgabe mit Hilfe der Eyetracking-Technik beobachtet. Aus den Experimenten ergeben sich Aufschlüsse über das tatsächliche Vorgehen von Studierenden beim Lesen technischer Zeichnungen. Die Analyse der empirischen Untersuchungen legt die Vermutung nahe, dass die zunehmende Digitalisierung der Gesellschaft und der zunehmende Umgang mit elektronischen Kleinstgeräten verstärkt zu einem punktuellen und schnellen Wahrnehmungsverhalten führen. Ruhe und Gelassenheit im Umgang mit Informationen gehen verloren, ebenso das Denken im Kontext. Somit muss es Aufgabe der Lehre sein, wieder verstärkt ein ruhiges, strukturiertes und auf Zusammenhänge ausgerichtetes Vorgehen zu vermitteln und zu üben.
Passive solar elements for both direct and indirect gains, are systems used to maintain a comfortable living environment while saving energy, especially in the building energy retrofit and adaptation process. Sunspaces, thermal mass and glazing area and orientation have been often used in the past to guarantee adequate indoor conditions when mechanical devices were not available. After a period of neglect, nowadays they are again considered as appropriate systems to help face environmental issues in the building sector, and both international and national legislation takes into consideration the possibility of including them in the building planning tools, also providing economic incentives. Their proper design needs dynamic simulation, often difficult to perform and time consuming. Moreover, results generally suffer from several uncertainties, so quasi steady-state procedures are often used in everyday practice with good results, but some corrections are still needed. In this paper, a comparative analysis of different solutions for the construction of verandas in an existing building is presented, following the procedure provided by the slightly modified and improved Standard EN ISO 13790:2008. Advantages and disadvantages of different configurations considering thermal insulation, windows typology and mechanical ventilation systems are discussed and a general intervention strategy is proposed. The aim is to highlight the possibility of using sunspaces in order to increase the efficiency of the existing building stock, considering ease of construction and economic viability.
Energy Performance of Verandas in the Building Retrofit Process (PDF Download Available). Available from: https://www.researchgate.net/publication/303093420_Energy_Performance_of_Verandas_in_the_Building_Retrofit_Process [accessed Jul 5, 2017].
Das Fraunhofer ISE hat im Rahmen dieses Projektes die hauseigene Wasserstoff-Tankstelle um einen zweiten Hochdruckspeicher, einen zweiten Mitteldruckverdichter, zwei Mengenmesser und eine Elektrolyse-Leistungssteuerung erweitert und die Lüftung im Betriebsmittelraum verändert. Zudem wurde die im Projekt vom Partner Sick entwickelte Gasanalytik in die Tankstelle und die vom Partner Sick entwickelte Mengenmessung in einen 200kW Elektrolyse-Teststand integriert.
Damit wurde die Betankungskapazität pro Fahrzeug und insgesamt verbessert, die Zuverlässigkeit der Tankstelle erhöht und die Infrastruktur geschaffen, um Langzeituntersuchungen von Gasverunreinigungen, Elektrolyse-Degradation und Wasserstoff-Verlusten an der Tankstelle durchzuführen, sowie einen Feldtest für die entwickelten Komponenten des Partners Sick durchzuführen. Alle Nachrüstungen waren erfolgreich - die Lüftungsanpassung zur Verbesserung der Vorkühlungszuverlässigkeit und Lebensdauer erfüllte jedoch bis zum Projektende nicht die Erwartungen. Bei Messungen mit und für die Hochschule Offenburg wurden zudem mit sehr geringem Mehraufwand Messdaten bezüglich Genauigkeit des vorhanden Coriolismesser erhoben und verwertet.
Ein bisher ungelöstes Problem für die kommerzielle Nutzung von Wasserstoffbetriebenen Fahrzeugen ist die eichfähige Mengenmessung bei der Betankung. Bisher auf dem Markt befindliche Durchflussmesser für Wasserstofftankstellen arbeiten nach dem Coriolis-Prinzip und erreichen nicht die geforderten Messunsicherheiten.
Ziel des Arbeitspakets der Hochschule Offenburg ist die Entwicklung eines neuen Ansatzes zur eichfähigen Mengenmessung. Notwendige Bedingung für die Eichfähigkeit ist zum einen eine ausreichende Messrichtigkeit, zum anderen muss Messbeständigkeit sichergestellt werden. Hierzu gehören beispielsweise Manipulationssicherheit, Elektromagnetische Verträglichkeit und Sensorbeständigkeit. Aufgrund der geforderten Manipulationssicherheit kommen Messmethoden wie bspw. das Wiegen der Fahrzeuge oder Tanksysteme nicht infrage, da diese vom Verbraucher beeinflusst werden können. Deshalb soll ein Durchflussmesser basierend auf dem Düsenmessverfahren entwickelt werden.
Im Rahmen des Projektes wurden zunächst die Rahmenbedingungen bei Wasserstoffbetankungsvorgängen nach der Norm SAE J2601 erarbeitet. Basierend darauf wurde ein dynamisches Simulationsmodell entwickelt, welches die Berechnung der zeitlich veränderlichen Massen- und Volumenströme während der Betankung ermöglicht. Diese dienen als Grundlage für die Auslegung der Düsengeometrie sowie der benötigten Temperatur- und Druckmesstechnik. Parallel zu dem Durchflussmessgerät wurde ein gravimetrischer Teststand entwickelt, welcher es ermöglicht, die Messgenauigkeit der Düse zu untersuchen. Der Teststand ist mit einem Wasserstofftank ausgestattet, welcher während Betankungsversuchen befüllt werden kann um realistische Strömungsbedingungen zu erreichen.
Während den anschließenden Versuchen an der Wasserstofftankstelle des Fraunhofer ISE in Freiburg konnte gezeigt werden, dass die Messdüse sowie der Teststand funktionieren und das Düsenmessverfahren ein geeignetes Verfahren für Durchflussmessungen an Wasserstofftankstellen darstellt. Es konnten Messunsicherheiten im Bereich der Eichfähigkeit (um 1 %) erreicht werden.
Die SICK AG beteiligt sich im Projekt Wasserstoffinfrastruktur Freiburg mit der eigen entwickelten Gasanalytik und Durchflussmesstechnik. Die Grundlagenuntersuchungen im Laufe des Projektes dienten dazu die industrielle Eignung der eingesetzten Messtechnik festzustellen sowie Erkenntnisse für eine spätere Weiterentwicklung von eichfähigen Ultraschall- H2 Gaszählern zu ermitteln.
The effective executing innovation projects requires multiple estimation of market success of new product features in the early stages of customer-centered innovation process such as strategy formulation, evaluation of ideas and concepts and also at a stage close to the market launch. The attempts to integrate customers for estimation of the market success often result in time-consuming customer interviews or lengthy field research. For this reason, industrial companies usually try to skip customer surveys even if they risk that their innovations will fail to bring the anticipated economic outcomes. In many practical cases, the customer surveys are simply not feasible or too expensive. As a result, the internal assessments within companies are frequently the only resource available in innovation process in the industrial environment. The paper discusses the possibilities of the fast identification of promising innovation opportunities and new product features based on the internal competences of companies. It compares the results of customer surveys with the estimation of internal company-experts and analyses the accuracy and validity of the expert assessments. The presented case studies demonstrate the accuracy rate between 43% and 77% for prediction of new product features with high market potential by company-internal experts. The paper proposes the evaluation methods to increase the accuracy rate and outlines that one of the essential requirements for reliable forecasting by the experts is their profound understanding of the customer working process, the ability to estimate the importance of customer needs and to assess the level of customer satisfaction with current products on the market.
Wireless sensor networks have found their way into a wide range of applications among which environmental monitoring systems have attracted increasing interests of researchers. The main challenges for the applications are scalability of the network size and energy efficiency of the spatially distributed motes. These devices are mostly battery-powered and spend most of their energy budget on the radio transceiver module. A so-called Wake-On-Radio (WOR) technology can be used to achieve a reasonable balance among power consumption, range, complexity and response time. In this paper, a novel design for integration of WOR into IEEE802.1.5.4 is presented, which flexibly allows trade-offs in energy consumption between sender and receiver station, between real-time capability and energy consumption. For identical behavior, the proposed scheme is significantly more efficient than other schemes, which were proposed in recent publications, while preserving backward compatibility with standard IEEE802.15.4 transceivers.
Um Rückschlüsse auf das Vorgehen von Studierenden beim Lesen technischer Darstellungen ziehen zu können, wurden 49 Probanden aus dem Studiengang „Maschinenbau“ der Hochschule Offenburg bei ihrer Lösungssuche für eine zeichnerische Aufgabe mit Hilfe der Eyetracking-Technik beobachtet. Die Analyse der empirischen Untersuchungen legt die Vermutung nahe, dass die zunehmende Digitalisierung der Gesellschaft verstärkt zu einem punktuellen und flüchtigen Wahrnehmungsverhalten führen. Ruhe und Gelassenheit im Umgang mit Informationen gehen verloren, ebenso das Denken im Kontext. Nach Ansicht der Autoren sollte in der Ausbildung deshalb eine stärkere Konzentration auf die Grundbausteine und die grundlegenden Zusammenhänge des jeweiligen Fachgebietes, Entschleunigung, Förderung von Versteh-, Abstraktions- und Denkfähigkeit und auf der Motivation zur studentischen Eigenleistung liegen.
Fans stärken Marken
(2016)
Der hier vorliegende Beitrag beschreibt die mit der Finite-Elemente-Methode (FEM) gewonnenen Untersuchungsergebnisse zur Bestimmung von Stützziffern und Kerbwirkungszahlen bei Getriebewellen. Es handelt sich dabei zum einen um die Kerbüberlagerung einer umlaufenden Halbkreisnut in Kombination mit überlagerter Querbohrung. Da zur Bestimmung der Stützwirkungszahlen die Berechnung der bezogenen Spannungsgradienten in Tiefenrichtung benötigt wird, wurden die Parameter der Kerbgeometrie (der Umlaufnutradius sowie der Querbohrungsdurchmesser) variiert. Als Ergebnis dieser Arbeit wurde festgehalten, dass sich die Formzahl infolge der Durchdringungskerbe im Vergleich zur Formzahl einer Einzelkerbe (z. B. Umlaufnut oder Querbohrung) erhöht und dementsprechend erhöht sich die Kerbwirkungszahl deutlich im Vergleich zu einer Einzelkerbe. Die numerisch erfassten Kerbwirkungszahlen
an den erforschten Durchdringungskerben wurden mit analytischen Ansätzen aus der Fachliteratur verglichen. Entsprechende Diagramme und Zahlenwerte werden zur Abschätzung der Kerbwirkungs- und Stützzahlen je nach Belastungsart Torsion, Biegung und Zug/Druck angegeben.
Der vorliegende Beitrag beschreibt erste Untersuchungsergebnisse an Wellenabsätzen mit im Kerbgrund überlagerter Schrägbohrung, mit Hilfe der Finite-Elemente-Methode (FEM). Als Beispiel hierfür können Walzen mit Heizkanälen in Walzwerken, Turbinen- und Kurbelwellen genannt werden. Es ist nicht bekannt, welche Spannungserhöhung die Schrägbohrung im Wellenabsatz hervorruft. In den Normen oder Richtlinien sind keine Angaben über Formzahlen für diese Kerbkombination vorhanden. Deshalb werden die Formzahlen für unterschiedliche schräggebohrte Wellenabsätze je Belastungsart ermittelt, ausgewertet und entsprechende Formzahldiagramme und Gestaltungshinweise angegeben.
In diesem Beitrag wird die Anwendbarkeit von bereits in der Literatur beschriebenen und in der Praxis bewährten Entlastungsgeometrien für Wellenabsätze auf Zahnwellen mit freiem Auslauf mit der Methode der Finiten Elemente FEM untersucht. Dabei zeigte sich, dass eine direkte Verwendung der bestehenden Vorschläge nicht immer möglich war. Deshalb wurden diese Entlastungsnuten und -übergänge für eine beanspruchungsgerechte Anwendung im Bereich der Zahnwellen modifiziert und optimiert. Basierend auf den dabei erzielten Ergebnissen wurden neue konstruktive Möglichkeiten zur günstigsten Ausprägung der freien Auslaufgestaltung entwickelt und erforscht. Der beobachtete merkliche Abfall der Kerbspannung infolge von Entlastungsmöglichkeiten soll dem Konstrukteur einen Anlass geben, diese häufiger anzuwenden. Die Industrie, insbesondere kleinere Betriebe, können mithilfe der in diesem Aufsatz vorliegenden Erkenntnisse durch optimierte Dimensionierung der Profiwellen Kosten und Bauteilgewicht sparen.
Flexible Three-dimensional Camera-based Reconstruction and Calibration of Tracked Instruments
(2016)
Navigated instruments commonly include applied parts, e.g. burrs or saw blades, that need to be calibrated with respect to the attached or integrated tracker. Since this calibration has to be very precise, it is often performed by the manufacturer. However, due to the great variety of instruments and the option to exchange the applied parts (e.g. burrs) there is a definite demand for flexible and generic calibration techniques. Furthermore, if we look into the medical field, there is also a need for calibrating sterile instruments. We propose a new and flexible camera-based calibration technique that addresses these demands by working contactlessly, precisely, and generically for a large variety of tracked instruments. This is realized using one or more tracked cameras which are calibrated with respect to an attached or integrated tracker. The tracked instrument is rotated in front of the camera(s) and its 3D geometry and surface are reconstructed from the 2D images in the coordinate system of the attached or integrated tracker. The 3D geometry of the navigated instrument was reconstructed with an accuracy of under 0.2 mm. The radius of a sphere-shaped instrument was reconstructed with an RMS deviation of 0.015mm.
This paper focuses on appropriately measuring the accuracy of forecasts of load behavior and renewable generation in micro-grid operation. Common accuracy measures like the root mean square of the error are often difficult to interpret for system design, as they describe the mean accuracy of the forecast. Micro-grid systems, however, have to be designed to handle also worst case situations. This paper therefore suggests two error measures that are based on the maximum function and that better allow understanding worst case requirements with respect to balancing power and balancing energy supply.
In a recent paper it has been shown that the effective nonlinear constant which is used in a P-Matrix approach to describe third-order intermodulation (IMD3) in surface acoustic wave (SAW) devices can be obtained from finite element (FEM) calculations of a periodic cell using nonlinear tensor data [1]. In this paper we extend this FEM calculation and show that the IMD3 of an infinite periodic array of electrodes on a piezoelectric substrate can be directly simulated in the sagittal plane. This direct approach opens the way for a FEM based simulation of nonlinearities for finite and generalized structures avoiding the simplifications of phenomenological approaches.
This is a commentary note on the situation of functional neuroimaging in psychiatry. With this we would like to encourage psychiatrists and the journal editors of psychiatric and related journals to at least rethink the role of functional neuroimaging in this discipline and use these imaging techniques in their various aspects of clinical diagnosis and therapy regimens,respectively.
Gamification implies the application of methods and design patterns from gaming to non-gaming areas like learning or working. We applied an existing gamification design to production processes in an organization which provides sheltered employment for impaired persons. In contrast to existing work, we investigated not only a short period but a complete workday to measure the effects on the work performance. The study indicates that gamification has (1) a negative effect on workers with considerable cognitive impairments, (2) no significant effect on workers with medium cognitive impairments and (3) a positive effect on workers with mild cognitive impairments.
In this work, we investigate how gamification can be integrated into work processes in the automotive industry. The contribution contains five parts: (1) An introduction showing how gamification has become increasingly common, especially in education, health and the service industry. (2) An analysis on the state of the art of gamified applications, discussing several best practices. (3) An analysis of the special requirements for gamification in production, regarding both external norms and the mindset of workers in this domain. (4) An overview of first approaches towards a gamification of production, focusing on solutions for impaired workers in sheltered work organizations. (5) A study with a focus group of instructors at two large car manufacturers. Based on the presentation of three potential designs for the gamification of production, the study investigates the general acceptance of gamification in modern production and determines which design is best suited for future implementations.
Geschichte(n) der Medizin
(2016)
Nach dem großen Erfolg der beiden ersten Bände liegt jetzt der Abschluss der Trilogie vor. Renommierte Autorinnen und Autoren erzählen einmal mehr lebendige und mitreißende Geschichte(n) der Medizin über Krankheiten, Ärzte und Forscher. Wie kam es beispielsweise zur Entdeckung der "Perkussion"? Wer war Avicenna? Warum wurde der Name Goldberg so berühmt? Was haben Rembrandt und Schiller gemeinsam? Welchen Einfluss nahm deutsche Medizin auf den Fernen Osten? Die populärwissenschaftlich aufbereitete Welt der Medizingeschichte(n) fasziniert nicht nur, sie sorgt auch immer wieder für überraschende Erkenntnisse und Aha-Erlebnisse. Das Buch richtet sich daher gleichermaßen an medizinische Laien wie Fachleute.
To do justice to the legacy of Alexander von Humboldt, a 19th century German scientist and explorer an information and knowledge management system is required to preserve the author’s original intent and promote an awareness of all his relevant works. Although all of Humboldt's works can be found on the internet as digitized papers, the complexity and internal interconnectivity of the writings is not very transparent. Humboldt's concepts of interaction cannot be adequately represented only by digitized papers or scanned documents.
The Humboldt Portal is an attempt to create a new generation of digital libraries, providing a new form of interaction and synthesis between humanistic texts and scientific observation. The digital version of his documents supplies dynamic links to sources, maps, images, graphs and relevant texts in accordance with his visions, because “everything is interconnectedness”.
Wireless Sensor Networks (WSN) have emerged as interesting topic in the research community due to its manifold applications. One of the main challenges of this field is the energy consumption of the nodes, which typically is quite restricted due to the required lifetime of such WSNs. To solve that problem several energy-saving MAC protocols have been developed so far. One of them recently presented by the authors is the so-called SmartMAC as an extension to the IEEE802.15.4 standard. In this paper, we present the implementation details of the porting of the SmartMAC protocol to the discrete event network simulator NS3. We develop this module for NS3 to simulate the performance, multi node execution, and multi node configuration. Along with this model, we also present an energy model for the evaluation of the energy consumption. The current implementation in NS3 is based on the LR-WPAN (Low-Rate Wireless Personal Area Networks) as specified by the IEEE802.15.4 (2006) standard. The simulation results show that the SmartMAC with its sleep and wake-up mechanisms for the transceivers, is significantly more efficient than the current NS3 MAC (Medium Access Control) scheme.
The interaural time difference (ITD) is an important cue for the localization of sounds. ITD changes as little as 10 μs can be detected by the human auditory system. By provision of one ear with a cochlear implant (CI) ITD are altered due to the partial replacement of the peripheral auditory system. A hearing aid (HA), in contrast, does not replace but adds a processing delay component to the peripheral auditory system extending ITD. The aim of the present study was to quantify interaural stimulation timing between these different modalities to estimate the need for central auditory temporal compensation in single sided deaf CI users or bimodal CI/HA users. For this purpose, wave V latencies of auditory brainstem responses evoked either acoustically (ABR) or electrically via the CI (EABR) have been measured. The sum of delays consisting of CI signal processing measured in the MED-EL OPUS2 audio processor and EABR wave V latencies evoked on different intracochlear sites allowed an estimation of the entire CI channel-specific delay for MED-EL MAESTRO CI systems. We compared these values with ABR wave V latencies measured in the contralateral normal hearing or HA provided ear in different frequency bands. The results showed that EABR wave V latencies were consistently shorter than those evoked acoustically in the unaided normal hearing ear. Thus, artificial delays within the audio processor can be implemented to adjust interaural stimulation timing. The currently implemented group delays in the MED-EL CI system turned out to be reasonably similar to those of the unaided ear. For adjustment of CI and contralateral HA, in contrast, an adjustable additional across-frequency delay in the range of 1–11 ms implemented in the CI would be required. Especially for bimodal CI/HA users the adjustment of interaural stimulation timing may induce improved binaural hearing, reduced need for central auditory temporal compensation and increased acceptance of the CI/HA provision.
Im Rahmen der Cochleaimplantat (CI)-Versorgung werden sowohl intraoperativ als auch postoperativ verschiedene elektrische und elektrophysiologische Diagnostikverfahren eingesetzt, bei denen elektrische Messgrößen vom CI erfasst und elektrophysiologische Messungen bei CI-Patienten durchgeführt werden. Zu den elektrophysiologischen Diagnostikverfahren zählen die Messung der elektrisch evozierten Summenaktionspotenziale des Hörnervs, die Registrierung der elektrisch evozierten auditorischen Hirnstammpotenziale und die Erfassung der elektrisch evozierten auditorischen kortikalen Potenziale. Diese Potenziale widerspiegeln die Erregung des Hörnervs und die Reizverarbeitung in verschiedenen Stationen der aufsteigenden Hörbahn bei intracochleärer elektrischer Stimulation mittels eines CI. Bei den aktuellen CI sind die Beurteilung der Elektrodenlage sowie die Prüfung der Ankopplung des Implantats an den Hörnerv wichtige Anwendungsgebiete der elektrophysiologischen Diagnostikverfahren. Ein weiteres bedeutendes Einsatzfeld stellt die Prüfung der Reizverarbeitung in der Hörbahn dar. Das Hauptanwendungsgebiet dieser Verfahren bildet jedoch die Unterstützung der Anpassung der CI-Sprachprozessoren bei Säuglingen und Kleinkindern auf der Basis elektrophysiologischer Schwellen.