Refine
Year of publication
- 2014 (11) (remove)
Document Type
- Article (unreviewed) (11) (remove)
Language
- English (11) (remove)
Has Fulltext
- no (11) (remove)
Is part of the Bibliography
- yes (11)
Keywords
- Algorithmus (1)
- Antenne (1)
- Applikation (1)
- Benchmark (1)
- Bioelement (1)
- Computersysteme (1)
- Datenerfassung (1)
- Drahtloses lokales Netz (1)
- Elektrochemie (1)
- Formale Beschreibung (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (10)
- INES - Institut für nachhaltige Energiesysteme (3)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (1)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (1)
- Fakultät Wirtschaft (W) (1)
- IUAS - Institute for Unmanned Aerial Systems (1)
Open Access
- Closed Access (2)
- Open Access (1)
Using patent information for identification of new product features with high market potential
(2014)
Mice and rats make up 95% of all animals used in medical research and drug discovery and development. Monitoring of physiological functions such as ECG, blood pressure, and body temperature over the entire period of an experiment is often required. Restraining of the animals in order to obtain this data can cause great inconvenience. The use of telemetric systems solves this problem and provides more reliable results. However, these devices are mostly equipped with batteries, which limit the time of operation or they use passive power supplies, which affects the operating range. The semi-passive telemetric implant being presented is based on RFID technology and overcomes these obstacles. The device is inductively powered using the magnetic field of a common RFID reader device underneath the cage, but is also able to operate for several hours autonomously. Being independent from the battery capacity, it is possible to use the implant over a long period of time or to re-use the device several times in different animals, thus avoiding the disadvantages of existing systems and reducing the costs of purchase and refurbishment.
Formal Description of Inductive Air Interfaces Using Thévenin's Theorem and Numerical Analysis
(2014)
With the development of new integrated circuits to interface radio frequency identification protocols, inductive air interfaces have become more and more important. Near field communication is not only able to communicate, but also possible to transfer power wirelessly and to build up passive devices for logistical and medical applications. In this way, the power management on the transponder becomes more and more relevant. A designer has to optimize power consumption as well as energy harvesting from the magnetic field. This paper discusses a model with simple equations to improve transponder antenna matching. Furthermore, a new numerical analysis technique is presented to calculate the coupling factors, inductions, and magnetic fields of multiantenna systems.
Hybrid SPECT/US
(2014)
A benchmark analysis of Long Range (LoRaTM) Communication at 2.45 Ghz for safety applications
(2014)
Pressure dynamics in metal-oxygen (metal-air) batteries: a case study on sodium superoxide cells
(2014)
Electrochemical reactions in metal–oxygen batteries come along with the consumption or release of gaseous oxygen. We present a novel methodology for investigating electrode reactions and transport phenomena in metal–oxygen batteries by measuring the pressure dynamics in an enclosed gas reservoir above the oxygen electrode. The methodology is exemplified by a room-temperature sodium–oxygen battery forming sodium superoxide (NaO2) in an electrolyte of diethylene glycol dimethyl ether (diglyme) and sodium trifluoromethanesulfonate (NaOSO2CF3, NaOTf). The experiments are supported by microkinetic simulations with a one-dimensional multiphysics continuum model. During galvanostatic cycling over 30 cycles, a constant oxygen consumption/release rate is observed upon discharge/charge. The number of transferred electrons per oxygen molecule is calculated to 1.01 ± 0.02 and 1.03 ± 0.02 for discharge and charge, respectively, confirming the nature of the oxygen reaction product as superoxide O2–. The same ratio is observed in cyclic voltammetry experiments with low scan rate (<1 mV/s). However, at higher scan rates, the ratio increases as a result of oxygen transport limitations in the electrolyte. We introduce electrochemical pressure impedance spectroscopy (EPIS) for simultaneously analyzing current, voltage, and pressure of electrochemical cells. Pressure recording significantly increases the sensitivity of impedance toward oxygen transport properties of the porous electrode systems. In addition, we report experimental data on the diffusion coefficient and solubility of oxygen in electrolyte solutions as important parameters for the microkinetic models.