Refine
Document Type
- Conference Proceeding (19) (remove)
Conference Type
- Konferenzartikel (14)
- Konferenz-Abstract (2)
- Konferenzband (2)
- Konferenz-Poster (1)
Language
- German (19) (remove)
Keywords
- Kalman Filter (2)
- Mikroelektronik (2)
- Automation (1)
- Digitale Turschilder (1)
- Drehstrom (1)
- E-Ink (1)
- E-Paper (1)
- EKF-SLAM (1)
- Energy Harvesting (1)
- Gleichstrom (1)
Institute
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (19) (remove)
Open Access
- Open Access (12)
- Bronze (5)
- Closed (4)
- Closed Access (3)
An international study summarizes the threat situation in the OT environment under the heading "Growing security threats" [1]. According to this study, attacks on automation systems are likely to increase in the future. Accordingly, an automation system must be able to protect the integrity of the transmitted information in the future. This requirement is motivated, among other things, by the fact that the network-side isolation of industrial communication systems is no longer considered sufficient as the sole protective measure. This paper uses the example of PROFINET to show how the future requirements for a real-time communication protocol can be met and how they can be derived from the IEC 62443 standard.
Evaluierung von Kalman Filter Konfigurationen zur Roboterlokaliserung mittels Sensordatenfusion
(2023)
In dieser Arbeit werden drei verschiedene Konfigurationen der von Tom Moore, für das Robot Operating System, entwickelte Kalman-Filter vorgestellt. Diese bilden die Grundlage für eine Lokalisierung mittels Sensorfusion in dem verwendeten ROS-Framework. Ziel dieser Arbeit ist der Aufbau und die Verifikation einer Lokalisierung für ein mobiles Robotersystem Husky A200 der Firma Clearpath Robotics. Hierzu wurden die Möglichkeiten des bestehenden Systems untersucht und mehrere Versionen von Lokalisierungsfiltern konfiguriert. Am an Ende, wird eine Verifikation der Ergebnisse in verschiedenen Szenarien gegeneinandergestellt. Hierzu werden die Ergebnisse einer Variante des Extended Kalman-Filters in 2D (EKF2D), eine Variante des Unscented Kalman-Filter in 2D (UKF2D) und eine Variante des Extended Kalman-Filters in 3D (EKF3D) verifiziert und verglichen. Die Untersuchungen ergaben das der EKF2D die besten und robustesten Ergebnisse für eine Lokalisierung erbringt, trotz, im Vergleich zu der UKF2D Variante, 17,3 % höhere Endpositionsabweichung aufweist. Die in diesem Projekt gewählte EKF3D Konfigurationsvariante eignet sich, wegen seinen starken Ungenauigkeiten in der Höhenbestimmung nicht für eine aussagekräftige Positionsbestimmung.
Die Positionierung mobiler Systeme mit hoher Genauigkeit ist eine Voraussetzung für intelligentes autonomes Verhalten, sowohl in der Feldrobotik als auch in industriellen Umgebungen. Dieser Beitrag beschreibt den Aufbau einer Roboterplattform und ihre Verwendung für den Test und die Bewertung von Kalman-Filter-Konfigurationen. Der Aufbau wurde mit einem mobilen Roboter Husky A200 und einem LiDAR-Sensor (Light Detection and Ranging) realisiert. Zur Verifizierung des vorgeschlagenen Aufbaus wurden fünf verschiedene Szenarien ausgearbeitet. Mit denen wurden die Filter auf ihre Leistungsfähigkeit hinsichtlich der Genauigkeit der Positionsbestimmung getestet.
The visual-inertial mapping and localization system maplab is analyzed by its implementation and subsequent evaluation. The mapping or localization is based on environmental feature detection. In addition to creating maps, there is also the option of fusion of several maps and thus mapping extensive areas and using them for further analysis of data. In this way, various software tools can be used to optimize the existing data sets.
Two sensor components are needed: an inertial measuring unit (IMU) and a monochrome camera, which are combined by a hardware rig and put into operation for the analysis of the visual-inertial system. System calibration is crucial for precision and system functioning and is based on nonlinear dynamic state estimation. This ensures the best possible estimate of the position of the environmental feature and the map. Maplab is particularly suitable for mapping rooms or small building complexes as the implementation and evaluation of the results in different application scenarios show. Special emphasis is laid on the evaluation of larger scenarios, in which is shown, that the system is struggling to keep up geometric consistencies and thus provide an accurate map.
MPC-Workshop Februar 2020
(2021)
Das hier vorgestellte System verbindet das neue Konzept der Peer-to-Peer-Navigation mit dem Einsatz von Augmented Reality zur Unterstützung von bettseitig durchgeführten externen Ventrikeldrainagen. Das sehr kompakte und genaue Gesamtsystem beinhaltet einen Patiententracker mit integrierter Kamera, eine Augmented-Reality-Brille mit Kamera und eine Punktionsnadel bzw. einen Pointer mit zwei Trackern, mit dessen Hilfe die Anatomie des Patienten aufgenommen wird. Die exakte Position und Richtung der Punktionsnadel wird unter Zuhilfenahme der aufgenommenen Landmarken berechnet und über die Augmented-Reality-Brille für den Chirurgen sichtbar auf dem Patienten dargestellt. Die Methode zur Kalibrierung der statischen Transformationen zwischen Patiententracker und daran befestigter Kamera beziehungsweise zwischen den Trackern der Punktionsnadel sind für die Genauigkeit sehr wichtig und werden hier vorgestellt. Das Gesamtsystem konnte in vitro erfolgreich getestet werden und bestätigt den Nutzen eines Peer-to-Peer-Navigationssystems.
Zeitliche Anpassung führt zu verbesserter Schalllokalisation bei bimodal versorgten CI-/HG-Trägern
(2021)
Bei bimodal versorgten Cochlea-Implantaten (CI) / Hörgerät (HG)-Trägern entsteht durch die unterschiedliche Signalverarbeitung der Geräte eine konstante interaurale Zeitverzögerung in der Größenordnung von mehreren Millisekunden. Für MED-EL CI-Systeme in Kombination mit verschiedenen HG-Typen haben wir den jeweiligen Device-Delay-Mismatch quantifiziert. In der aktuellen Studie untersuchen wir den Einfluss der Device-Delay-Mismatch bei simulierten und tatsächlichen bimodalen Hörern auf die Genauigkeit der Schalllokalisation.
Um den Device-Delay-Mismatch bei bimodal versorgten Patienten zu verringern, haben wir die CI-Stimulation um die gemessene HG-Signallaufzeit und zwei weitere Werte verzögert. Nach einer Angewöhnungsphase war der effektive Winkelfehler bei Verzögerung um die HG-Signallaufzeit hochsignifikant reduziert im Vergleich zu der Testkondition ohne CI-Verzögerung (mittlere Verbesserung: 11 % ; p < .01, Wilcoxon Signed Rank Test). Aber auch mit den beiden weiteren Verzögerungswerten wurden Verbesserungen erreicht. Anhand der Ergebnisse lässt sich der optimale patientenspezifische Verzögerungswert näher eingrenzen.