Refine
Year of publication
- 2002 (8) (remove)
Document Type
Conference Type
- Konferenzartikel (1)
- Sonstiges (1)
Language
- English (8) (remove)
Has Fulltext
- no (8) (remove)
Is part of the Bibliography
- yes (8)
Keywords
- Dünnschichtchromatographie (3)
- Diode-array detection (2)
- Faseroptik (2)
- Biomechanik (1)
- Densitometrie (1)
- Dichtebestimmung (1)
- Finite-Elemente-Methode (1)
- Kubelka-Munk theory (1)
- Linearization models (1)
- Messtechnik (1)
Institute
Open Access
- Closed Access (4)
- Closed (3)
- Bronze (1)
- Open Access (1)
High performance thin layer chromatography (HPTLC) is a frequently used separation technique which works well for quantification of caffeine and quinine in beverages. Competing separation techniques, e.g. high-performance liquid chromatography (HPLC) or gas chromatography (GC), are not suitable for sugar-containing samples, because these methods need special pretreatment by the analyst. In HPTLC, however, it is possible to separate ‘dirty’ samples without time-consuming pretreatment, because disposable HPTLC plates are used. A convenient method for quantification of caffeine and quinine in beverages, without sample pretreatment, is presented below. The basic theory of in-situ quantification in HPTLC by use of remitted light is introduced and discussed. Several linearization models are discussed.
A home-made diode-array scanner has been used for quantification; this, for the first time, enables simultaneous measurements at different wavelengths. The new scanner also enables fluorescence evaluation without further equipment. Simultaneous recording at different wavelengths improves the accuracy and reliability of HPTLC analysis. These aspects result in substantial improvement of in-situ quantitative densitometric analysis and enable quantification of compounds in beverages.
A new diode-array scanner in combination with a computer-controlled application system meets all the demands of modern HPTLC measurement. Automatic application, simultaneous measurements at different wavelengths, and different linearization models enable appropriate evaluation of all analytical questions. The theory of error propagation recommends quantification at reflectance values smaller than 0.8; this can be verified only by use of diode-array scanning. The same theory also recommends quantification by use of peak height data, because the theory predicts best precision only for peak height evaluation. Diode-array scanning with reflectance monitoring enables appropriate validation in TLC and HPTLC analysis. All these aspects result in substantial improvement of in-situ quantitative densitometric analysis, and simultaneous recording at different wavelengths opens the way for chemometric evaluation, e.g. peak purity monitoring, which improves the accuracy and reliability of HPTLC analysis.
Time Resolved Measurements of Soot Concentrations and Mean Particle Sizes during EUDC and ECE Cycles
(2002)
The bandwidth behavior of graded-index multimode fibers (GI-MMFs) for different launching conditions is investigated to understand and characterize the effect of differential mode delay. In order to reduce the launch-power distribution the near field of a single-mode fiber is used to produce a controlled restricted launch. The baseband response is measured by observing the broadening of a narrow input pulse (time-domain measurement). The paper verifies the degradation in bandwidth due to profile distortion by scanning the spot of the single-mode fiber with a transversal offset from the center of the test sample. In addition, the impact of the launch-power distribution tuned by different spot-size diameters is demonstrated. Measurements were taken on ‘older’ 50-μm and 62.5-μm GI-MMFs as well as on laser-performance-optimized fibers more recently developed.
The use of a TLC scanner can be regarded as a key step in high performance thin layer chromatography (HPTLC). Densitometric measurements transform the substance distribution on a TLC plate into digital computer data. Systems that allow quantitative measurements have been available for many years for either fluorescence or ultraviolet absorption measurements, while lately the reflection analysis mode for both types is the most common application. New scanning approaches are designed to aid the analyst who has common demands for TLC-densitometry without using special data, such as scanned images. Two examples that have been developed lately in the laboratories of the authors are described in this paper. These approaches were developed on the basis of current needs for analysts who employ TLC as a tool in research, as well as in routine analysis. One approach is aimed to support analysts in economically disadvantaged areas, where cost intensive apparatus is unsuitable but trace analysis by simple means is required. The other system, allows the spectral determination of chromatographic spots on TLC plates covering the ultraviolet and visible range, thus, revealing highly desired information for the analyst.
HPTLC (High Performance Thin Layer Chromatography) is a well known and versatile separation method which shows a lot of advantages and options in comparison to other separation techniques. The method is fast and inexpensive and does not need time-consuming pretreatments. Using fiber-optic elements for controlled light-guiding, the TLC-method was significantly improved: the new HPTLC-system is able to measure simultaneously at different wavelengths without destroying the plate surface or the analytes on the surface. For registration of the sample distribution on a HPTLC-plate we developed a new and sturdy diode-array HPTLC- scanner which allows registration of spectra on the TLC- plates in the range of 198 nm to 610 nm with a spectral resolution better than 1.2 nm. The spatial resolution on plate is better than 160 micrometers . In the spectral mode, the new HPTLC-scanner delivers much more information than the commonly used TLC-scanner. The measurement of 450 spectra of one separation track does not need more than three minutes. However, in the fixed wavelength mode the contour plot can be measured within 15 seconds. In this case, the signal will be summarized and averaged over a spectral range having FWHM from 10 nm to 25 nm depending on the substance under test. The new diode-array HPTLC-scanner makes various chemometric applications possible. The new method can be used easily in clinical diagnostic systems easily, e.g. for blood and uring investigations. In addition, new applications are possible. For example, the rich structured PAHs were studied. Although the separation is incomplete the 16 compounds can be quantified using suitable wavelengths.
The aim of this study was to develop a biomechanically validated finite element model to predict the biomechanical behaviour of the human lumbar spine in compression.
For validation of the finite element model, an in vitro study was performed: Twelve human lumbar cadaveric spinal segments (six segments L2/3 and six segments L4/5) were loaded in axial compression using 600 N in the intact state and following surgical treatment using two different internal stabilisation devices. Range of motion was measured and used to calculate stiffness.
A finite element model of a human spinal segment L3/4 was loaded with the same force in intact and surgically altered state, corresponding to the situation of biomechanical in vitro study.
The results of the cadaver biomechanical and finite element analysis were compared. As they were close together, the finite element model was used to predict: (1) load-sharing within human lumbar spine in compression, (2) load-sharing within osteoporotic human lumbar spine in compression and (3) the stabilising potential of the different spinal implants with respect to bone mineral density.
A finite element model as described here may be used to predict the biomechanical behaviour of the spine. Moreover, the influence of different spinal stabilisation systems may be predicted.
A systematic toxicological analysis procedure using high-performance thin layer chromatography in combination with fibre optical scanning densitometry for identification of drugs in biological samples is presented. Two examples illustrate the practicability of the technique. First, the identification of a multiple intake of analgesics: codeine, propyphenazone, tramadol, flupirtine and lidocaine, and second, the detection of the sedative diphenhydramine. In both cases, authentic urine specimens were used. The identifications were carried out by an automatic measurement and computer-based comparison of in situ UV spectra with data from a compiled library of reference spectra using the cross-correlation function. The technique allowed a parallel recording of chromatograms and in situ UV spectra in the range of 197–612 nm. Unlike the conventional densitometry, a dependency of UV spectra by concentration of substance in a range of 250–1000 ng/spot was not observed.