Refine
Year of publication
- 2007 (17) (remove)
Document Type
- Conference Proceeding (12)
- Article (reviewed) (4)
- Article (unreviewed) (1)
Conference Type
- Konferenzartikel (9)
- Konferenz-Abstract (1)
- Konferenz-Poster (1)
- Konferenzband (1)
Language
- English (17) (remove)
Has Fulltext
- no (17) (remove)
Is part of the Bibliography
- yes (17)
Keywords
- CDMA (2)
- Chromatographie (1)
- Codierung (1)
- Emission (1)
- Energietechnik (1)
- FFF (1)
- Faseroptik (1)
- Gasanalyse (1)
- Mobile device (1)
- Ruß (1)
Institute
Open Access
- Closed (7)
- Closed Access (7)
- Open Access (3)
- Bronze (1)
Previous studies of the hyphenation of gas chromatographic separation and spectrophotometric detection in the ultraviolet wavelength range between 168 and 330 nm showed a high potential for applications where the analysis of complex samples is required. Within this paper the development of a state-of-the-art detection system for compounds in the vapour phase is described, offering an improved behaviour compared to previous systems: Dependent on the requirements of established detection systems hyphenated with gas chromatography, the main components of the system have to be designed for optimum performance and reliability of the spectrophotometric detector: A deuterium lamp as a broadband light source has been selected for improved stability in the measurements. A new-type absorption cell based on fiber-optics has been developed considering the dynamic necessary to compete with existing techniques. In addition, the influence of the volume of the cell on the chromatogram needs to be analyzed. Tests for determining the performance of the absorption cell in terms of chemical and thermal influences have been carried out. A new spectrophotometer with adequate spectral resolution in the wavelength range, offering improved stability and dynamic for an efficient use in this application was developed. Furthermore, the influence of each component on the performance, reliability and stability of the sensor system will be discussed. An overview and outlook over the potential applications in the environmental, scientific and medical field will be given.
In thin-layer chromatography, fiber-bundle arrays have been introduced for spectral absorption measurements in the UV-region. Using all-silica fiber bundles, the exciting light will be detected after re-emission on the plate with a fiberoptic spectrometer. In addition, fluorescence light can be detected which will be masked by the re-emitted light. Therefore, it is helpful to separate the absorption and fluorescence on the TLC-plate. A modified three-array assembly has been developed: using one array for detection, the two others are used for excitation with broadband band deuterium-light and with UV-LEDs adjusted to the substances under test. As an example, the quantification of glucosamine in nutritional supplements or spinach leaf extract will be described. Using simply heating of the amino-plate for derivation, the reaction product of Glucosamine can be detected sensitively either by light absorption or by fluorescence, using the new fiber-optic assembly. In addition, the properties of the new 3-row fiber-optic array and the commercially available UV-LEDs will be shown, in the interesting wavelength region for excitation of fluorescence, from 260 nm to 360 nm. The squint angle having an influence on coupling efficiency and spatial resolution will be measured with the inverse farfield method. Some properties of UV-LEDs for analytical applications will be described and discussed, too.
A platform of an electronic capsule is being developed for multi-task medical assistant application. It includes a near field telemetry unit for bidirectional communication system of 115 KHz low carrier frequency for inductive data transmission suited for human body energy transfer. The system triggers an actuator for drug delivery in various time and release forms via wireless external control, it has the ability to record temperature, measure pH of the body (additional sensors), and retrieve data to the outside. It consists of a 32bit processor, memory, external peripheries, and detection facility. The complete system is designed to fit small-size mass medical application with low power consumption, size of 7x25mm. The system is designed, simulated and emulated on FPGA. A final layout of the complete chip design is still under progress.
A new electronic capsule with bidirectional communication system is being developed for multi-task application. The capsule is designed to be a platform for medical assistant application inside the body. The designed telemetry unit is a synchronous bidirectional communication block using continuous phase DQPSK of 115 kHz low carrier frequency for inductive data transmission suited for human body energy transfer. The communication system can assist the electronic pill to trigger an actuator for drug delivery, to record temperature, or to measure pH of the body. It consists additionally to a 32bit processor, memory, external peripheries, and detection facility. The complete system is designed to fit small-size mass medical application with low power consumption, size of 7x25mm. The system is designed, simulated and emulated on FPGA. A final layout of the complete chip design is still under progress.
To provide proper solutions to the problem of device dependant content delivery, a fine categorization of the application target devices is needed. Earlier attempts provided two different presentations for desktop and mobile platforms. The mobile platform presentation was divided into three categories, based on a general classification (PDA, Smartphone or mobile phone). In order to improve the on mobile device presentation a finer categorization is introduced. In this paper, our focus is to clarify the concept of this more flexible presentation module, in which the delivered content depends on the efficiency of the device based on a selected set of capabilities.
Non-esterified plant oils gain ecological and economical importance, particularly in the EU where it is intended to increase the share of renewable energies. Plant oils do not require any chemical treatment so do not cause secondary pollution. The importance of plant oil will increase in Germany for mobile and stationary applications. The generation co-generation of heat and power is subsidized by the German “Erneuerbares Energiegesetz” and the “Kraft-Wärme-Kopplungsgesetz” when renewable fuels are used such as plant oils..
Plant oils have a much higher viscosity than conventional gas oil. It is mandatory to decrease the oil viscosity by heating prior to injection to assure proper injection and to avoid engine damage due to coke formation in the combustion chamber and at the injection nozzle. The German quality standard of Weihenstephan (RK-Qualitätsstandard 05/2000) for rape seed oil should be followed for use as diesel fuel. The chemical composition of plant oils is appreciably different in comparison to diesel fuels derived from mineral oils suggesting also different emission behavior.