Refine
Year of publication
- 2008 (41) (remove)
Document Type
- Conference Proceeding (12)
- Part of a Book (9)
- Contribution to a Periodical (6)
- Article (unreviewed) (5)
- Article (reviewed) (4)
- Book (4)
- Report (1)
Conference Type
- Konferenzartikel (10)
- Konferenz-Abstract (1)
- Sonstiges (1)
Has Fulltext
- no (41) (remove)
Is part of the Bibliography
- yes (41)
Keywords
- Dünnschichtchromatographie (2)
- Finite-Elemente-Methode (2)
- Nahrung (2)
- Optimierung (2)
- Akustik (1)
- Analyse (1)
- Blechformteil (1)
- Chromatographie (1)
- DC-DC-Wandler (1)
- DMD (1)
Institute
Open Access
- Closed Access (10)
- Open Access (9)
- Closed (7)
- Bronze (3)
HPTLC on amino plates, with simple heating of the plates for derivatization, has been used for quantification of glucosamine in nutritional supplements. On heating the plate glucosamine reacts to form a compound which strongly absorbs light between 305 and 330 nm, with weak fluorescence. The reaction product can be detected sensitively either by absorption of light or by fluorescence detection. The detection limit in absorption mode is approximately 25 ng per spot. In fluorescence mode a detection limit of 15 ng is achievable. A calibration plot for absorption detection is linear in the range 25 to 4000 ng glucosamine. The derivative formed from glucosamine by heating is stable for months, and the relative standard deviation is 1.64% for 600 ng glucosamine. The amounts of glucosamine found in nutritional supplements were in agreement with the label declarations.
We present an improved quantification method for urethane found in spirits. The quantification is based on a derivatization reaction using cinnamaldehyde in combination with phosphoric acid. Measurements were carried out in the wavelength range from 445 to 460 nm using a diode-TLC device. An LED was used for illumination purposes. It emits very dense light at 365 nm. The quantification range of urethane is in the lower ng range. By applying 20 µL of sprits, the urethane quantification range is from 320 µg/L to 8.1 mg urethane per litre of spirit. The range of linearity covers nearly two magnitudes. The method is cheap, fast and reliable, and is able to monitor all European legislation limits without time-consuming sample pre-treatments.
A new miniaturized capsule with 32bit processor and bidirectional communication system is being developed for multitask application. The capsule is designed to be a platform for medical assistant application inside the body. The processor core SIRIUS has been developed, simulated, synthesized to a netlist and verified. The designed telemetry unit is a synchronous bidirectional communication block using continuous phase DQPSK of 115 kHz low carrier frequency for inductive data transmission suited for human body energy transfer. The communication system can assist the electronic pill to trigger an actuator for drug delivery, to record temperature, or to measure pH of the body. The complete system is designed to fit small-size mass medical application with low power consumption, size of 7x25 mm. The system is designed, simulated, emulated on FPGA, and routed in AMIS Technology.
Advanced Truck Load Firm
(2008)
Aktiver RFID-Sensor
(2008)
Das in Schramberg ansässige Unternehmen Schweizer Electronic, einer der großen europäischen Leiterplattenhersteller, hat sich ein neues Geschäftsfeld als Systemlieferant für mikroelektronische Geräte erschlossen. Gemeinsam mit dem Institut für Angewandte Forschung der Hochschule Offenburg und Siemens hat das Unternehmen einen Datenlogger mit einer ISO 15693 kompatiblen 13,56 MHz RFID-Luftschnittstelle zur Serienreife entwickelt. Die SEAGsens Temperaturmessgeräte aus der Vorserienproduktion haben die ersten Feldtests erfolgreich bestanden. Die Großserienproduktion wird noch in diesem Jahr anlaufen.