Refine
Year of publication
Document Type
- Conference Proceeding (647)
- Article (unreviewed) (449)
- Article (reviewed) (426)
- Part of a Book (358)
- Bachelor Thesis (322)
- Contribution to a Periodical (221)
- Book (185)
- Other (127)
- Master's Thesis (84)
- Periodical Part (46)
Language
- German (1825)
- English (1149)
- Other language (3)
- Multiple languages (3)
- Russian (3)
- Spanish (1)
Keywords
- Kommunikation (30)
- Digitalisierung (28)
- Dünnschichtchromatographie (27)
- Marketing (26)
- Energieversorgung (22)
- Social Media (22)
- E-Learning (18)
- Management (18)
- COVID-19 (17)
- Industrie 4.0 (16)
Institute
- Fakultät Medien und Informationswesen (M+I) (992)
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (683)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (567)
- Fakultät Betriebswirtschaft und Wirtschaftsingenieurwesen (B+W) (397)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (205)
- INES - Institut für Energiesystemtechnik (126)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (84)
- Zentrale Einrichtungen (75)
- ACI - Affective and Cognitive Institute (45)
- IfTI - Institute for Trade and Innovation (30)
RETIS – Real-Time Sensitive Wireless Communication Solution for Industrial Control Applications
(2020)
Ultra-Reliable Low Latency Communications (URLLC) has been always a vital component of many industrial applications. The paper proposes a new wireless URLLC solution called RETIS, which is suitable for factory automation and fast process control applications, where low latency, low jitter, and high data exchange rates are mandatory. In the paper, we describe the communication protocol as well as the hardware structure of the network nodes for implementing the required functionality. Many techniques enabling fast, reliable wireless transmissions are used – short Transmission Time Interval (TTI), Time-Division Multiple Access (TDMA), MIMO, optional duplicated data transfer, Forward Error Correction (FEC), ACK mechanism. Preliminary tests show that reliable end-to-end latency down to 350 μs and packet exchange rate up to 4 kHz can be reached (using quadruple MIMO and standard IEEE 802.15.4 PHY at 250 kbit/s).
Industrie 4.0 bedeutet nicht nur einen Wandel der technischen Möglichkeiten und Arbeitsbedingungen, sondern auch einen Bedarf an neuen, sich kontinuierlich weiterentwickelnden Kompetenzen und die Bereitschaft der Beschäftigten, Veränderungen mitzugestalten. Spielerische Ansätze der Kompetenzentwicklung können v.a. bei weiterbildungsfernen Mitarbeitern hilfreich sein, um das komplexe Thema verständlich zu vermitteln. Der Beitrag beschreibt ein Seminarkonzept mit integriertem Brettspiel, mit dem Teilnehmer anhand eines fiktiven Unternehmens (Müller GmbH) die Transformation eines Unternehmens in die Industrie 4.0 spielerisch nachvollziehen. Dieses Konzept erweist sich in einer ersten Evaluation als durchaus vielversprechend.
Die Einführung der extrakorporalen Zirkulation unter Verwendung eines medikamentös induzierten Herzstillstands ermöglicht der Herzchirurgie die Herzoperationen, wie sie heute bekannt sind. Eine große Debatte besteht in der optimalen Zusammensetzung und Anwendungsweise der kardioplegischen Lösungen [6]. In der Helios Klinik für Herzchirurgie in Karlsruhe werden die kalte, kristalloide Kardioplegie nach Bretschneider und die modifizierte, kalte Blutkardioplegie nach Calafiore verwendet. Die vorliegende Arbeit beschäftigt sich mit der Frage, ob die Wahl der Kardioplegie Einwirkungen auf den intraoperativen und postoperativen Verlauf einer Bypass-Operation hat.
In der dazu angefertigten Studie wurden die Daten von 135 KHK Patienten retrospektiv erfasst und statistisch analysiert. Darunter wurden 81 Patienten mit der kalten Blutkardioplegie nach Calafiore behandelt und 53 Patienten mit der kristalloiden HTKLösung nach Bretschneider. Die demografischen Daten und Dringlichkeit der Operationen unterscheiden sich nicht signifikant voneinander. Bei den intraoperativen Parametern sind hinsichtlich der Hämoglobin-, Natrium-, und Kaliumkonzentration signifikante Unterschiede erkennbar. Weitere intraoperative Laborwerte zeigen keine Signifikanz. Die intraoperativen Parameter der Myokardprotektionsverfahren unterscheiden sich bezüglich der verabreichten Kardioplegiemenge. Bei postoperativen Parametern sind keine besonderen Signifikanzen notiert.
Die kristalloide Kardioplegie nach Bretschneider wie auch die modifizierte kalte Blutkardioplegie nach Calafiore sind sichere und effektive Verfahren. Einige Unterschiede konnten zugunsten der Blutkardioplegie nach Calafiore gefunden werden, die spezifisch für das jeweilige Verfahren sind. Zwingende Argumente für oder gegen eines dieser Verfahren konnten nicht gefunden werden.
BACKGROUND:
While hearing aids for a contralateral routing of signals (CROS-HA) and bone conduction devices have been the traditional treatment for single-sided deafness (SSD) and asymmetric hearing loss (AHL), in recent years, cochlear implants (CIs) have increasingly become a viable treatment choice, particularly in countries where regulatory approval and reimbursement schemes are in place. Part of the reason for this shift is that the CI is the only device capable of restoring bilateral input to the auditory system and hence of possibly reinstating binaural hearing. Although several studies have independently shown that the CI is a safe and effective treatment for SSD and AHL, clinical outcome measures in those studies and across CI centers vary greatly. Only with a consistent use of defined and agreed-upon outcome measures across centers can high-level evidence be generated to assess the safety and efficacy of CIs and alternative treatments in recipients with SSD and AHL.
METHODS:
This paper presents a comparative study design and minimum outcome measures for the assessment of current treatment options in patients with SSD/AHL. The protocol was developed, discussed, and eventually agreed upon by expert panels that convened at the 2015 APSCI conference in Beijing, China, and at the CI 2016 conference in Toronto, Canada.
RESULTS:
A longitudinal study design comparing CROS-HA, BCD, and CI treatments is proposed. The recommended outcome measures include (1) speech in noise testing, using the same set of 3 spatial configurations to compare binaural benefits such as summation, squelch, and head shadow across devices; (2) localization testing, using stimuli that rove in both level and spectral content; (3) questionnaires to collect quality of life measures and the frequency of device use; and (4) questionnaires for assessing the impact of tinnitus before and after treatment, if applicable.
CONCLUSION:
A protocol for the assessment of treatment options and outcomes in recipients with SSD and AHL is presented. The proposed set of minimum outcome measures aims at harmonizing assessment methods across centers and thus at generating a growing body of high-level evidence for those treatment options.
Die drei großen Hersteller von Cochlea-Implantat (CI)-Systemen ermöglichen es klinischen Audiologen, die Mikrofoneigenschaften der meisten CI-Sprachprozessoren zu prüfen. Dazu können bei diesen Sprachprozessoren Monitorkopfhörer angeschlossen und das/die Mikrofon(e) inklusive eines Teils der Signalvorverarbeitung abgehört werden. Präzise Angaben dazu, mit welchen Stimuli, bei welchem Pegel und nach welchem Kriterium diese Prüfung stattfinden soll, machen die CI-Hersteller nicht. Auf Basis dieser Prüfung soll der Audiologe dann über die Funktion der Mikrofone und damit darüber entscheiden, ob der betreffende Sprachprozessor an den Hersteller eingeschickt wird oder nicht.
Zur Objektivierung der CI-Sprachprozessor-Mikrofon-Prüfung haben wir eine Testbox entwickelt, mit der alle abhörbaren aktuellen CI-Sprachprozessoren der drei großen Hersteller geprüft werden können. Die Box wurde im 3D-Druck-Verfahren hergestellt. Der zu prüfende Sprachprozessor wird in die Messbox eingehängt und über einen darin verbauten Lautsprecher mit definierten Prüfsignalen (Sinustöne unterschiedlicher Frequenz) beschallt. Das Mikrofonsignal wird über das Kabel der Monitorkopfhörer herausgeführt und mit einer Shifting- and Scaling-Schaltung in einen Spannungsbereich transformiert, der für die AD-Wandlung mit einem Mikrokontroller (ATmega1280 verbaut auf einem Arduino Mega) geeignet ist. Derselbe Mikrokontroller übernimmt über einen eigens gebauten DA-Wandler die Ausgabe der Sinustöne über den Lautsprecher. Signalaufnahme und –wiedergabe erfolgen mit jeweils 38,5 kHz Samplingrate. Der für jede Frequenz über mehrere Perioden des Prüfsignals ermittelte Effektivwert wird mit dem Effektivwert, der mit einem neuwertigen Referenzprozessor für diese Frequenz gemessen wurde, verglichen. Die Messergebnisse werden graphisch auf einem Display ausgegeben.
Derzeit läuft eine erste Datenerhebung mit in der Klinik subjektiv auffällig gewordenen CI-Sprachprozessoren, die anschließend in der Messbox untersucht werden. So sollen realistische Schwellen für kritische Abweichungen von den Referenz-Effektivwerten ermittelt werden. Im weiteren Verlauf sollen dann Hit und False Alarm-Raten der subjektiven Prüfung bestimmt werden.
The effect of fluctuating maskers on speech understanding of high-performing cochlear implant users
(2016)
Objective: The present study evaluated whether the poorer baseline performance of cochlear implant (CI) users or the technical and/or physiological properties of CI stimulation are responsible for the absence of masking release. Design: This study measured speech reception thresholds (SRTs) in continuous and modulated noise as a function of signal to noise ratio (SNR). Study sample: A total of 24 subjects participated: 12 normal-hearing (NH) listeners and 12 subjects provided with recent MED-EL CI systems. Results: The mean SRT of CI users in continuous noise was −3.0 ± 1.5 dB SNR (mean ± SEM), while the normal-hearing group reached −5.9 ± 0.8 dB SNR. In modulated noise, the difference across groups increased considerably. For CI users, the mean SRT worsened to −1.4 ± 2.3 dB SNR, while it improved for normal-hearing listeners to −18.9 ± 3.8 dB SNR. Conclusions: The detrimental effect of fluctuating maskers on SRTs in CI users shown by prior studies was confirmed by the current study. Concluding, the absence of masking release is mainly caused by the technical and/or physiological properties of CI stimulation, not just the poorer baseline performance of many CI users compared to normal-hearing subjects. Speech understanding in modulated noise was more robust in CI users who had a relatively large electrical dynamic range.
The ability to detect a target signal masked by noise is improved in normal-hearing listeners
when interaural phase differences (IPDs) between the ear signals exist either in the masker or in
the signal. To improve binaural hearing in bilaterally implanted cochlear implant (BiCI) users, a
coding strategy providing the best possible access to IPDs is highly desirable. Outcomes of a
previous study (Zirn, Arndt et al. 2016) revealed that a subset of BiCI users showed improved
IPD detection thresholds with the fine structure processing strategy FS4 compared to the
constant rate strategy HDCIS using narrowband stimuli. In contrast, little differences between
the coding strategies were found for broadband stimuli with regard to binaural speech
intelligibility level differences (BILD) as an estimate of binaural unmasking. Compared to normalhearing
listeners (7.5 ± 1.2 dB) BILD were small in BiCI users (around 0.5 dB with both coding
strategies).
In the present work, we investigated the influence of binaural fitting parameters on BILD. In our
cohort of BiCI users many were implanted with electrode arrays differing in length left versus
right. Because this length difference typically corresponded to the distance of two electrode
contacts the first modification of bilateral fitting was a tonotopic adjustment by deactivation of the
most apical electrode contact on the side with the deeper inserted array (tonotopic approach).
The second modification was the isolation of the residual, most apical electrode contacts by
deactivation of the basally adjacent electrode contact on each side (tonotopic sparse approach).
Applying these modifications, BILD improved by up to 1.5 dB.