Refine
Year of publication
- 2016 (105) (remove)
Document Type
- Conference Proceeding (45)
- Article (reviewed) (30)
- Part of a Book (8)
- Bachelor Thesis (5)
- Book (5)
- Patent (4)
- Master's Thesis (3)
- Article (unreviewed) (3)
- Letter to Editor (2)
Conference Type
- Konferenzartikel (33)
- Konferenz-Abstract (7)
- Sonstiges (4)
- Konferenzband (1)
Keywords
- Eingebettetes System (5)
- Hochschule (3)
- Mathematik (3)
- Messtechnik (3)
- Radiologie (3)
- RoboCup (3)
- 6LoWPAN (2)
- Abtragung (2)
- Brennstoffzelle (2)
- Computertomografie (2)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (105) (remove)
Open Access
- Closed Access (37)
- Open Access (27)
- Bronze (7)
Elektronische Pille zur steuerbaren Abgabe einer Substanz in einem menschlichen oder tierischen Körper, (a) mit einem Gehäuse (3), in welchem die abzugebende Substanz (17) aufgenommen und in welchem eine Abgabeöffnung (47) zur Abgabe der Substanz (17) vorgesehen ist, wobei die Substanz (17) zur Abgabe aus dem Gehäuse (3) mit einem vorbestimmten Druck beaufschlagt ist, (b) mit einer elektronischen Steuereinheit (53, 59, 61, 63), und (c) mit einer im Verlauf eines Abgabepfades angeordneten Ventileinheit (33), welche von der Steuereinheit (53, 59, 61, 63) von einer Geschlossen- Stellung in eine Geöffnet-Stellung steuerbar ist und umgekehrt, (d) dadurch gekennzeichnet, (e) dass die Ventileinheit (33) eine von der elektronischen Steuereinheit (53, 59, 61, 63) ansteuerbare Heizeinheit (49) umfasst, (f) dass die Ventileinheit (33) ein Schaltelement (39) umfasst, welches in der Geschlossen-Stellung zumindest mit einem Teilbereich dichtend an einem Ventilsitz (37) der Ventileinheit (33) anliegt und welches von der Heizeinheit (49) beheizbar ist, (g) dass das Schaltelement (39) zwei temperaturabhängige stabile Schaltstellungen aufweist, welche durch eine Formänderung des Schaltelements (39) definiert sind, und (h) die Heizeinheit (49) an der dem Ventilsitz (37) abgewandten Seite des Schaltelements (39) angeordnet und integriert mit dem Schaltelement (39) ausgebildet ist (i) wobei die Steuereinheit (53, 59, 61, 63) zum Öffnen der Ventileinheit (33) die Heizeinheit (49) aktiviert, so dass das Schaltelement (39) bei Überschreiten einer Schwellentemperatur aus der Geschlossen-Stellung in die Geöffnet-Stellung geschaltet wird und (j) wobei die Steuereinheit (53, 59, 61, 63) zum Schließen der Ventileinheit (33) die Heizeinheit (49) deaktiviert, so dass das Schaltelement bei Unterschreiten einer Schwellentemperatur aus der Geöffnet-Stellung in die Geschlossen-Stellung schaltet.
This paper describes the new Sweaty II humanoid adult size robot trying to qualify for the RoboCup 2016 adult size humanoid competition. Based on experiences during RoboCup 2014, the Sweaty robot has been completely redesigned to a new robot Sweaty II. A major change is the use of linear actuators for the legs. Another characteristic is its indirect actuation by means of rods. This allows a variable transmission ratio depending on the angle of a joint.
After having described many different aspects of our team software in previous years, in this paper we take the freedom to describe the magmaChallenge framework provided by the magmaOffenburg team. The framework is used as a benchmark tool to run different challenges like the running challenge in 2014 or the kick accuracy challenge in 2015. This description should serve as a documentation to simplify the maintenance by the community and to add new benchmarks in the future.
MPC-Workshop Februar 2016
(2016)
Transthoracic impedance cardiography (ICG) is a non-invasive method for determination of hemodynamic parameters. The basic principle of transthoracic ICG is the measurement of electrical conductivity of the thorax over the time. The aim of the study was the analysis of hemodynamic parameters from healthy individuals and the evaluation of various hemodynamic monitoring devices. Fourteen men (mean age 25 ± 4.59 years) and twelve women (mean age 24 ± 3.5 years) were measured during the cardiovascular engineering laboratory at Offenburg University of Applied Sciences, Offenburg, Germany. The ICG recordings were measured with the devices CardioScreen 1000, CardioScreen 2000 and TensoScreen with the corresponding Software Cardiovascular Lab 2.5 (Medis Medizinische Messtechnik GmbH, Illmenau, Germany). In order to create identical frame conditions, all measurements were recorded in the same position and for the same duration. Various positions were simulated from horizontal lying position to vertical standing position. Altogether, more than 30 hemodynamic parameters were measured.
In contrast to conventional aortic valve replacement, the Transcatheter Aortic Valve Implantation (TAVI) is a new highly specialist alternative to surgical valve replacement for patients with symptomatic severe aortic stenosis and high operative risk. The procedure was performed in a minimally invasive way and was introduced at the university heart centre, Freiburg – Bad Krozingen in 2008. The results have been getting better and better over the years. The aim of the investigation is the analysis of electrocardiogram conduction time and the electrocardiography changes recorded hours and days after the procedure depending on artificial heart valve models, which may lead to pacemaker implantation, even the analysis of the effectiveness of treatment.
Kommentar zu "Intracortical microstimulation of human somatosensory cortex" von Sharlene N. Flesher et al., veröffentlicht in Science Translational Medicine, Vol. 8, No. 361, Seite 361ra141 (DOI: 10.1126/scitranslmed.aaf8083)
Geschichte(n) der Medizin
(2016)
Nach dem großen Erfolg der beiden ersten Bände liegt jetzt der Abschluss der Trilogie vor. Renommierte Autorinnen und Autoren erzählen einmal mehr lebendige und mitreißende Geschichte(n) der Medizin über Krankheiten, Ärzte und Forscher. Wie kam es beispielsweise zur Entdeckung der "Perkussion"? Wer war Avicenna? Warum wurde der Name Goldberg so berühmt? Was haben Rembrandt und Schiller gemeinsam? Welchen Einfluss nahm deutsche Medizin auf den Fernen Osten? Die populärwissenschaftlich aufbereitete Welt der Medizingeschichte(n) fasziniert nicht nur, sie sorgt auch immer wieder für überraschende Erkenntnisse und Aha-Erlebnisse. Das Buch richtet sich daher gleichermaßen an medizinische Laien wie Fachleute.
A new yield function for lamellar gray cast iron materials is proposed. The new model is able to describe the results of recently performed microstructure-based finite-element computations that resolve the three dimensional yield surface of three different gray cast irons. The yield function requires only the yield stress in tension and compression of the respective material as model parameters. Furthermore, the algorithmic formulation of the new model is assessed for numerical robustness and efficiency.