Home Care Applications and Ambient Assisted Living become increasingly attractive. This is caused as well by market pull, as the number of elderly people grows monotonously, as well as by technology push, as technological advances and attractive products pave the way to economically advantageous offerings. However, in real-life applications, a significant number of challenges remain. Those include seamless communication between products from different supplier, due to the lack of sufficiently standardized solutions, energy budgets, and scalability of solutions. This paper presents the experience from the InCASA project (Integrated Network for Completely Assisted Senior Citizen's Autonomy), where architectures for heterogeneous physical and logical communication flows are examined.
A novel approach of a test environment for embedded networking nodes has been conceptualized and implemented. Its basis is the use of virtual nodes in a PC environment, where each node executes the original embedded code. Different nodes run in parallel, connected via so-called virtual channels. The environment allows to modifying the behavior of the virtual channels as well as the overall topology during runtime to virtualize real-life networking scenarios. The presented approach is very efficient and allows a simple description of test cases without the need of a network simulator. Furthermore, it speeds up the process of developing new features as well as it supports the identification of bugs in wireless communication stacks. In combination with powerful test execution systems, it is possible to create a continuous development and integration flow.
Nowadays the processing power of mobile phones, Smart phones and PDA is increasing, as well as the transmission bandwidth. Nevertheless there is still the need to reduce the content and the need of processing the data. Proposals and solutions for dynamic reduction of the transmitted content will be discussed. For that, device specific properties will be taken into account, aiming at reducing the need of processing power at the client side to display the 3D Virtual Reality data. Therefore, well known technologies like data compression are combined with new approaches to achieve the goal of adaptive content transmission. For device dependant reduction of processing power the data has to be pre-processed at the server side or the server itself has to take over functionality of weak mobile devices.
Cardiac resynchronization therapy is an established therapy for heart failure patients with sinus rhythm, reduced left ventricular ejection fraction and prolongation of QRS duration. The aim of the study was to evaluate ventricular desynchronization with electrical interventricular delay (IVD) to left ventricular delay (LVD) ratio in atrial fibrillation heart failure patients. IVD and LVD were measured by transesophageal posterior left ventricular ECG recording. In atrial fibrillation heart failure patients with prolonged QRS duration, the mean IVD-to-LVD-ratio was 0.84 +/- 0.42 with a range from 0.17 to 2.2 IVD-to-LVD-ratio. IVD-to-LVD-ratio correlated with QRS duration. IVD-to-LVD-ratio may be a useful parameter to evaluate electrical ventricular desynchronization in atrial fibrillation heart failure patients.
The application of leaky feeder (radiating) cables is a common solution for the implementation of reliable radio communication in huge industrial buildings, tunnels and mining environment. This paper explores the possibilities of leaky feeders for 1D and 2D localization in wireless systems based on time of flight chirp spread spectrum technologies. The main focus of this paper is to present and analyse the results of time of flight and received signal strength measurements with leaky feeders in indoor and outdoor conditions. The authors carried out experiments to compare ranging accuracy and radio coverage area for a point-like monopole antenna and for a leaky feeder acting as a distributed antenna. In all experiments RealTrac equipment based on nanoLOC radio standard was used. The estimation of the most probable path of a chirp signal going through a leaky feeder was calculated using the ray tracing approach. The typical non-line-of-sight errors profiles are presented. The results show the possibility to use radiating cables in real time location technologies based on time-of-flight method.
Introduction: Cardiac resynchronization therapy (CRT) with biventricular pacing (BV) is an established therapy for heart failure (HF) patients (P) with ventricular desynchronisation, but not all patients improved clinically. Aim of this study was to evaluate electrical intra-left ventricular conduction delay (LVCD) and interventricular conduction delay (IVCD), to better select patients for CRT.
Methods: 65 HF patients (age 63.4 ± 10.6 years; 7 females, 58 males) with New York Heart Association (NYHA) class 3 ± 0.2, 24.4 ± 6.7 % left ventricular (LV) ejection fraction and 167.4 ± 35.6 ms QRSD were included. Esophageal TO Osypka focused hemispherical electrodes catheter was perorally applied in position of maximum LV deflection to measure LVCD between onset and offset of LV deflection and IVCD between earliest onset of QRS in the 12-channel surface ECG and onset of LV deflection in the focused bipolar transesophageal LV electrogram.
Results: There were 50 responders with LVCD of 76.5 ± 20.4 ms, IVCD of 80.5 ± 26.1 ms (P=0.34) and QRSD of 171 ± 37.7 ms. 15 non-responders had longer LVCD of 90 ± 28.5 ms (P = 0.045), shorter IVCD of 50.1 ± 29.1 ms (P < 0.001) and QRSD of 155.3 ± 25 ms (P=0.14). During 21.3 ± 20.3 month BV pacing follow-up, the responder`s NYHA classes improved from 3 ± 0.2 to 2. ± 0.3 (P < 0.001) whereas the non-responders NYHA classes did not improve from 3 ± 0.2 to 2.9 ± 0.3 (P = 0.43) during 15.7 ± 13.9 month BV pacing follow-up (53 Boston, 10 Medtronic and 2 St. Jude CRT devices).
Conclusion: Determination of electrical LVCD and IVCD by focused bipolar transesophageal LV electrogram recording may be an additional useful technique to improve patient selection for CRT.
In this work, we consider a duty-cycled wireless sensor network with the assumption that the on/off schedules are uncoordinated. In such networks, as all nodes may not be awake during the transmission of time synchronization messages, nodes will require to re-transmit the synchronization messages. Ideally a node should re-transmit for the maximum sleep duration to ensure that all nodes are synchronized. However, such a proposition will immensely increase the energy consumption of the nodes. Such a situation demands that there is an upper bound of the number of retransmissions. We refer to the time a node spends in re-transmission of the control message as broadcast duration. We ask the question, what should be the broadcast duration to ensure that a certain percentage of the available nodes are synchronized. The problem to estimate the broadcast duration is formulated so as to capture the probability threshold of the nodes being synchronized. Results show the proposed analytical model can predict the broadcast duration with a given lower error margin under real world conditions, thus demonstrating the efficiency of our solution.
In this paper we propose a motion framework forbipedal robots that decouples motion definitions from stabilizingthe robot. This simplifies motion definitions yet allows dynamicmotion adaptations. Two applications, walking and stopping onone leg, demonstrate the power of the framework. We show thatour framework is able to perform walking and stopping on one legeven under extreme conditions and improves walking benchmarkssignificantly in the RoboCup 3D soccer simulation domain.
Transthoracic impedance cardiography (ICG) is a non-invasive method for determination of hemodynamic parameters. The basic principle of transthoracic ICG is the measurement of electrical conductivity of the thorax over the time. The aim of the study was the analysis of hemodynamic parameters from healthy individuals and the evaluation of various hemodynamic monitoring devices. Fourteen men (mean age 25 ± 4.59 years) and twelve women (mean age 24 ± 3.5 years) were measured during the cardiovascular engineering laboratory at Offenburg University of Applied Sciences, Offenburg, Germany. The ICG recordings were measured with the devices CardioScreen 1000, CardioScreen 2000 and TensoScreen with the corresponding Software Cardiovascular Lab 2.5 (Medis Medizinische Messtechnik GmbH, Illmenau, Germany). In order to create identical frame conditions, all measurements were recorded in the same position and for the same duration. Various positions were simulated from horizontal lying position to vertical standing position. Altogether, more than 30 hemodynamic parameters were measured.
Introduction: Cardiac resynchronization therapy (CRT) with biventricular pacing is an established therapy for heart failure (HF) patients with sinus rhythm and ventricular desynchronisation. The aim of this study was to evaluate interventricular conduction delay (IVCD) and interatrial conduction delay (IACD) before and after premature ventricular contractions (PVC) in HF patients.
Methods: 13 HF patients (age 68 ± 10 years; 2 females, 11 males) with New York Heart Association functional class 2,8 ± 0.5, left ventricular (LV) ejection fraction 28,6 ± 12,6 %, 154 ± 25 ms QRS duration and PVC were analysed with bipolar transesophageal LV and left atrial electrogram recording and National Instruments LabView 2009 software. The level of significance of the t-test is 0,005.
Results: QRS duration increases during PVC (188 ± 32 ms) in comparison to the beat before (154 ± 25 ms, P = ) and after PVC (152 ± 25 ms,). IVCD increases during PVC up to 65 ± 33 ms (51 ± 19 ms in the beat before PVC, P=0.18, 49 ± 19 ms after PVC, P = 0.12). Intra-LV delay of 90 ± 16 ms is not different in the beat before PVC, 90 ± 14 ms during PVC (P = 0.99) and 94 ± 16 ms in the beat after PVC (P = 0.38). IACD is not significantly PVC influenced (67 ± 12 ms before PVC and 65 ± 13 ms after PVC, P = 0.71). Intra-left atrial conduction delay is not significant longer during PVC (57 ± 28 ms) than in the beat before PVC (54 ± 13 ms, P = 0.51) or after PVC (54 ± 8 ms, P = 0.45). PQ duration increases significantly after PVC (224 ± 95 ms) in comparison to the beat before PVC (176± 29 ms, P =...).
Conclusion: Transesophageal left cardiac electrocardiography with LabView 2009 software can improve evaluation of IVCD and IACD before, during and after PVC in HF patient selection for CRT.
The CAN bus still is an important fieldbus in various domains, e.g. for in-car communication or automation applications. To counter security threats and concerns in such scenarios we design, implement, and evaluate the use of an end-to-end security concept based on the Transport Layer Security protocol. It is used to establish authenticated, integrity-checked, and confidential communication channels between field devices connected via CAN. Our performance measurements show that it is possible to use TLS at least for non time-critical applications, as well as for generic embedded networks.
Wireless communication systems more and more become part of our daily live. Especially with the Internet of Things (IoT) the overall connectivity increases rapidly since everyday objects become part of the global network. For this purpose several new wireless protocols have arisen, whereas 6LoWPAN (IPv6 over Low power Wireless Personal Area Networks) can be seen as one of the most important protocols within this sector. Originally designed on top of the IEEE802.15.4 standard it is a subject to various adaptions that will allow to use 6LoWPAN over different technologies; e.g. DECT Ultra Low Energy (ULE). Although this high connectivity offers a lot of new possibilities, there are several requirements and pitfalls coming along with such new systems. With an increasing number of connected devices the interoperability between different providers is one of the biggest challenges, which makes it necessary to verify the functionality and stability of the devices and the network. Therefore testing becomes one of the key components that decides on success or failure of such a system. Although there are several protocol implementations commonly available; e.g., for IoT based systems, there is still a lack of according tools and environments as well as for functional and conformance testing. This article describes the architecture and functioning of the proposed test framework based on Testing and Test Control Notation Version 3 (TTCN-3) for 6LoWPAN over ULE networks.
Temperature regulation is an important component for modern high performance single -core and multi-core processors. Especially high operating frequencies and architectures with an increasing number of monolithically integrated transistors result in a high power dissipation and - since processor chips convert the consumed electrical energy into thermal energy - in high operating temperatures. High operating temperatures of processors can have drastic consequences regarding chip reliability, processor performance, and leakage currents. External components like fans or heat spreaders can help to reduce the processor temperature - with the disadvantage of additional costs and reduced reliability. Therefore, software based algorithms for dynamic temperature management are an attractive alternative and well known as Dynamic Thermal Management (DTM). However, the existing approaches for DTM are not taking into account the requirements of real-time embedded computing, which is the objective in the given project. The first steps are the profiling and the thermal modeling of the system, which is reported in this paper for a Freescale i. MX6Q quad-core microprocessor. An analytical model is developed and verified by an extensive set of measurement runs.
This paper describes the Sweaty II humanoid adult size robot trying to qualify for the RoboCup 2018 adult size humanoid competition. Sweaty came 2nd in RoboCup 2017 adult size league. The main characteristics of Sweaty are described in the Team Description Paper 2017. The improvements that have been made or are planned to be implemented for RoboCup 2018 are described in this paper.
This paper describes the Sweaty II humanoid adult size robot trying to qualify for the RoboCup 2017 adult size humanoid competition. Sweaty came 2nd in RoboCup 2016 adult size league. The paper describes the main characteristics of Sweaty that made this success possible, and improvements that have been made or are planned to be implemented for RoboCup 2017.
This paper describes the new Sweaty II humanoid adult size robot trying to qualify for the RoboCup 2016 adult size humanoid competition. Based on experiences during RoboCup 2014, the Sweaty robot has been completely redesigned to a new robot Sweaty II. A major change is the use of linear actuators for the legs. Another characteristic is its indirect actuation by means of rods. This allows a variable transmission ratio depending on the angle of a joint.
This paper describes the new Sweaty humanoid adult size robot trying to qualify for the RoboCup 2014 adult size humanoid competition. The robot is built from scratch to eventually allow it to run. One characteristic is that to prevent the motors from overheating, water evaporation is used for cooling. The robot is literally sweating which has given it its name. Another characteristic is, that the motors are not directly connected to the frame but by means of beams. This allows a variable transmission ratio depending on the angle.
The overview of public key infrastructure based security approaches for vehicular communications
(2015)
Modern transport infrastructure becomes a full member of globally connected network. Leading vehicle manufacturers have already triggered development process, output of which will open a new horizon of possibilities for consumers and developers by providing a new communication entity - a car, thus enabling Car2X communications. Nevertheless some of available systems already provide certain possibilities for vehicles to communicate, most of them are considered not sufficiently secured. During last 15 years a number of big research projects funded by European Union and USA governments were started and concluded after which a set of standards were published prescribing a common architecture for Car2X and vehicles onboard communications. This work concentrates on combining inner and outer vehicular communications together with a use of Public Key Infrastructure (PKI).
In this TDP we describe a new tool created for testing the strategy layer of our soccer playing agents. It is a complete 2D simulator that simulates the games based on the decisions of 22 agents. With this tool, debugging the decision and strategy layer of our agents is much more efficient than before due to various interaction methods and complete control over the simulation.
In the future, the tool could also serve as a measure to run simulations of game series much faster than with the 3D simulator. This way, the impact of different play strategies could be evaluated much faster than before.
After having described many different aspects of our team software in previous years, in this paper we take the freedom to describe the magmaChallenge framework provided by the magmaOffenburg team. The framework is used as a benchmark tool to run different challenges like the running challenge in 2014 or the kick accuracy challenge in 2015. This description should serve as a documentation to simplify the maintenance by the community and to add new benchmarks in the future.
This paper describes the magmaOffenburg 3D simulation team trying to qualify for RoboCup 2013. While last year’s TDP focused on different ways how robot behavior can be defined in the magmaOffenburg framework this year we focus on how we statistically evaluate new features on distributed systems. We also show some results gained through such analysis.
This paper describes the magmaOffenburg 3D simulation team trying to qualify for RoboCup 2012. While last year’s TDP focused on the tool set created for 3D simulation and the support for heterogeneous robot models, this year we focus on the different ways how robot behavior can be defined in the magmaOffenburg framework and how those behaviors can be improved by learning.
This paper describes the magmaOffenburg 3D simulation team trying to qualify for RoboCup 2011. While last year’s TDP focused on the tool set created for 3D simulation in this year we describe the further improvement in this tools as well as some new features we implemented focusing on heterogeneous robot models which seem to be used in RoboCup 2012.
An additional tool was written to simply generate situation-dependent strategies. Furthermore some tools, described last year, are now integrated in one single GUI to easy things up.
This paper describes the magmaOffenburg 3D simulation team trying to qualify for RoboCup 2010. While last year’s TDP focused on decisions making using extended behavior networks and on its software architecture and implementation in this year we describe the tool set that was created for RoboCup 3D. It contians a GUI for agent- and world state visualization, for evaluation of localization algorithms and benchmarks in general, a visual editor for Extended Behavior Networks creation and debugging, a live movement tool to interact with the joints and finally a tool for editing behavior motor files.
This paper describes the magmaOffenburg 3D simulation team trying to qualify for RoboCup 2009. It focuses on two distinctive features of the team: decisions making using extended behavior networks and its software architecture and implementation in Java to open the simulation for the Java community.
The Internet of Things (IoT), ubiquitous computing and ubiquitous connectivity, Cyber Physical Systems (CPS), ambient intelligence, Machine-to-Machine communication (M2M) or Car-to-Car (C2C)-communication, smart metering, smart grid, telematics, telecare, telehealth – there are many buzzwords around current developments related to the Internet.
This contribution gives an overview on such IoT-applications, as they are already used today to improve the availability of information, increase efficiency, push system limits and extend the value chain. At a closer look, the economic and technical development can be separated into different phases. It is interesting that we are currently at the threshold to a new phase, with decentralized and cooperative communication and control nodes as cornerstones. Thus, embedded systems and their connectivity are in the middle of the scene.
This recent development is described along with some example projects from the author’s team which are used in industrial automation, energy supply and distribution (home automation and smart metering), traffic engineering (cooperative driver assistance systems), and in telehealth and telecare.
Ranging errors are inevitable in all local positioning systems, including those based on Time-of-Flight (ToF) technique. Results of experiments show that the major cause for these errors is a signal degradation from multipath propagation. This effect is especially critical in case of Non-Light-of-Sight (NLOS) conditions. This paper describes causes that affects ranging errors for nanoLOC™-TOF-technology and presents estimations for the probability density functions of such errors under different NLOS conditions. The provided estimations allow the improvement of the accuracy of the localization through the subsequent mitigation of the ranging errors from the measurements. Additionally, it is proposed to increase the number of cases of NLOS-conditions for the improvement of the accuracy.
Security in IT systems, particularly in embedded devices like Cyber Physical Systems (CPSs), has become an important matter of concern as it is the prerequisite for ensuring privacy and safety. Among a multitude of existing security measures, the Transport Layer Security (TLS) protocol family offers mature and standardized means for establishing secure communication channels over insecure transport media. In the context of classical IT infrastructure, its security with regard to protocol and implementation attacks has been subject to extensive research. As TLS protocols find their way into embedded environments, we consider the security and robustness of implementations of these protocols specifically in the light of the peculiarities of embedded systems. We present an approach for systematically checking the security and robustness of such implementations using fuzzing techniques and differential testing. In spite of its origin in testing TLS implementations we expect our approach to likewise be applicable to implementations of other cryptographic protocols with moderate efforts.
An investigation is underway regarding the usefulness of altazimuth-mounting telescopes' incorporation of laser gyros for pointing and fiber gyros with extremely small random-walk coefficient for telescope inertial stabilization during tracking. A star tracker is expected to help stabilize long-term gyro bias. Gyro and telescope specifications have been derived by means of computer simulations and systems analyses.
Both German and French Air-Source Heat Pump (ASHP) markets have been enjoying an overall upwards trend for many years but, nevertheless, they remain merely slightly penetrated. In terms of market players and their share, the French market is aptly diversified, whereas the German one, being utterly dominated by one single manufacturer, is badly in need of some diversification. At the same time Korean ASHP manufacturers are targeting the French but not German ASHP market. The main purpose of the paper is to find out likely reasons for their one-sided engagement, primarily those associated with the ASHP technology and its system-related aspects.
This paper presents the elements and the results from the European research project inCASA (Integrated Network for Completely Assisted Senior Citizen’s Autonomy), which designed and implemented a seamless integration of heterogeneous systems and network protocols for regionally distributed telecare and telehealth applications. The integration includes a multitude of physical interface, the transcoding of data models using embedded middleware, and a backend system with open interfaces. The implementation was verified in field tests in five European countries.
Network landscape of recent time contains many different network technologies, a wide range of end-devices with a large scale of capabilities and power, and an immense quantity of information and data represented in different formats. Research on 3D imaging, virtual reality and holographic techniques will result in new user interfaces (UI) for mobile devices, will increase their diversity and variety. In this paper software architecture has been proposed to establish device and content format independent communication including 3D imaging and virtual reality data as content. As experimental validation the concept is implemented in collaborative Language Learning Game (LLG), which is a learning tool for language acquisition.
The combination of fossil-derived fuels with ethanol and methanol has acquired relevance and attention in several countries in recent years. This trend is strongly affected by market prices, constant geopolitical events, new sustainability policies, new laws and regulations, etc. Besides bio-fuels these materials also include different additives as anti-shock agents and as octane enhancer. Some of the chemical compounds in these additives may have harmful properties for both environment and public health (besides the inherent properties, like volatility). We present detailed Raman spectral information from toluene (C7H8) and ethanol (C2H6O) contained in samples of ElO gasoline-ethanol blends. The spectral information has been extracted by using a robust, high resolution Fourier-Transform Raman spectrometer (FT-Raman) prototype. This spectral information has been also compared with Raman spectra from pure additives and with standard Raman lines in order to validate its accuracy in frequency. The spectral information is presented in the range of 0 cm-1 to 3500 cm-1 with a resolution of 1.66cm-1. This allows resolving tight adjacent Raman lines like the ones observed around 1003cm-1 and 1030cm-1 (characteristic lines of toluene). The Raman spectra obtained show a reduced frequency deviation when compared to standard Raman spectra from different calibration materials. The FT-Raman spectrometer prototype used for the analysis consist basically of a Michelson interferometer and a self-designed photon counter cooled down on a Peltier element arrangement. The light coupling is achieved with conventional62.5/125μm multi-mode fibers. This FT-Raman setup is able to extract high resolution and frequency precise Raman spectra from the additives in the fuels analyzed. The proposed prototype has no additional complex hardware components or costly software modules. The mechanical and thermal disturbances affecting the FT-Raman system are mathematically compensated by accurately extracting the optical path information of the Michelson interferometer. This is accomplished by generating an additional interference pattern with a λ = 632.8 nm Helium-Neon laser (HeNe laser). It enables the FT-Raman system to perform reliable and clean spectral measurements from the materials under observation.
Targeting complex fractionated atrial electrocardiograms by automated algorithms during ablation of persistent atrial fibrillation has produced conflicting outcomes in previous electrophysiological studies and catheter ablation of atrial fibrillation and ventricular tachycardia. The aim of the investigation was to evaluate atrial and ventricular high frequency fractionated electrical signals with signal averaging technique.
Methods: Signal averaging electrocardigraphy allows high resolution ECG technique to eliminate interference noise signals in the recorded ECG. The algorithm use automatic ECG trigger function for signal averaged transthoracic, transesophageal and intra-cardiac ECG signals with novel LabVIEW software.
Results: The analysis in the time domain evaluated fractionated atrial signals at the end of the signal averaged P-wave and fractionated ventricular signals at the end of the QRS complex. We evaluated atrial flutter in the time domain with two-to-one atrioventricular conduction, 212.0 ± 4.1 ms atrial cycle length, 426.0 ± 8.2 ms ventricular cycle length, 58.2 ± 1.8 ms P-wave duration, 119.6 ± 6.4 ms PQ duration, 103.0 ± 2.4 ms QRS duration and 296.4 ± 6.8 ms QT duration. The analysis in the frequency domain evaluated high frequency fractionated atrial signals during the P-wave and high frequency fractionated ventricular signals during QRS complex.
Conclusions: Spectral analysis of signal averaging electrocardiography with novel LabVIEW software can be utilized to evaluate atrial and ventricular conduction delays in patients with atrial fibrillation and ventricular tachycardia. Complex fractionated atrial and ventricular electrocardiograms may be useful parameters to evaluate electrical cardiac bradycardia and tachycardia signals in atrial fibrillation and ventricular tachycardia ablation.
Spectral analysis of signal averaging electrocardiography in atrial and ventricular tachyarrhythmias
(2017)
Background: Targeting complex fractionated atrial electrograms detected by automated algorithms during ablation of persistent atrial fibrillation has produced conflicting outcomes in previous electrophysiological studies. The aim of the investigation was to evaluate atrial and ventricular high frequency fractionated electrical signals with signal averaging technique.
Methods: Signal averaging electrocardiography (ECG) allows high resolution ECG technique to eliminate interference noise signals in the recorded ECG. The algorithm uses automatic ECG trigger function for signal averaged transthoracic, transesophageal and intracardiac ECG signals with novel LabVIEW software (National Instruments, Austin, Texas, USA). For spectral analysis we used fast fourier transformation in combination with spectro-temporal mapping and wavelet transformation for evaluation of detailed information about the frequency and intensity of high frequency atrial and ventricular signals.
Results: Spectral-temporal mapping and wavelet transformation of the signal averaged ECG allowed the evaluation of high frequency fractionated atrial signals in patients with atrial fibrillation and high frequency ventricular signals in patients with ventricular tachycardia. The analysis in the time domain evaluated fractionated atrial signals at the end of the signal averaged P-wave and fractionated ventricular signals at the end of the QRS complex. The analysis in the frequency domain evaluated high frequency fractionated atrial signals during the P-wave and high frequency fractionated ventricular signals during QRS complex. The combination of analysis in the time and frequency domain allowed the evaluation of fractionated signals during atrial and ventricular conduction.
Conclusions: Spectral analysis of signal averaging electrocardiography with novel LabVIEW software can utilized to evaluate atrial and ventricular conduction delays in patients with atrial fibrillation and ventricular tachycardia. Complex fractionated atrial electrograms may be useful parameters to evaluate electrical cardiac arrhythmogenic signals in atrial fibrillation ablation.
The industry of the agave-derived bacanora, in the northern Mexican state of Sonora, has been growing substantially in recent years. However, this higher demand still lies under the influences of a variety of social, legal, cultural, ecological and economic elements. The governmental institutions of the state have tried to encourage a sustainable development and certain levels of standardization in the production of bacanora by applying different economical and legal strategies. However, a large portion of this alcoholic beverage is still produced in a traditional and rudimentary fashion. Beyond the quality of the beverage, the lack of proper control, by using adequate instrumental methods, might represent a health risk, as in several cases traditional-distilled beverages can contain elevated levels of harmful materials. The present article describes the qualitative spectral analysis of samples of the traditional-produced distilled beverage bacanora in the range from 0 cm−1 to 3500 cm−1 by using a Fourier Transform Raman spectrometer. This particular technique has not been previously explored for the analysis of bacanora, as in the case of other beverages, including tequila. The proposed instrumental arrangement for the spectral analysis has been built by combining conventional hardware parts (Michelson interferometer, photo-diodes, visible laser, etc.) and a set of self-developed evaluation algorithms. The resulting spectral information has been compared to those of pure samples of ethanol and to the spectra from different samples of the alcoholic beverage tequila. The proposed instrumental arrangement can be used the analysis of bacanora.
The formation of secondary phases in the porous electrodes is a severe mechanism affecting the lifetime of solid oxide fuel cells (SOFC). It can occur via various chemical mechanisms and it has a significant influence on cell performance due to pore clogging and deactivation of active surfaces and triple-phase boundary (TPB). We present a modeling and simulation study of nickel oxide formation (reoxidation) and carbon formation (coking) within the SOFC anode. We use a 2D continuum model based on a multi-phase framework [Neidhardt et al., J. Electrochem. Soc., 159, 9 (2012)] that allows the introduction of arbitrary solid phases (here: Ni, YSZ, NiO, Carbon) plus gas phase. Reactions between the bulk phases are modeled via interface-adsorbed species and are described by an elementary kinetic approach. Published experimental data are used for parameterization and validation. Simulations allow the prediction of cell performance under critical operation conditions, like (i) a non-fuel operation test, where NiO formation is taking place (Figure 1a), or (ii) an open circuit voltage (OCV) stability test under hydrocarbon atmosphere, where solid carbon is formed (Figure 1b). Results are applied for enhanced interpretation of experimental data and for prediction of safe operation conditions.
ECG simulators, available on the market, imitate the electric activity of the heart in a simplified manner. Thus, they are suitable for education purposes but not really for testing algorithms to recognize complex arrhythmias needed for pacemakers and implantable defibrillators. Especially certain discrimination between various morphologies of atrial and ventricular fibrillation needs simulators providing native electrograms of different patients’ heart rhythm events. This explains the necessity to develop an ECG simulator providing high-resolution native intracardiac and surface electrograms of in-vivo rhythm events. In this paper we demonstrate an approach for an ECG simulator based on a consumer multichannel soundcard and a corresponding software application for a laptop computer. This Live-ECG Simulator is able to handle invasive electrogram recordings from electrophysiological studies and send the data to a modified external soundcard for subsequent digital to analog conversion. The hardware is completed with an electronic circuit providing level adjustment to adapt the output amplitude to the input conditions of several cardiac implants.
The improvements in the hardware and software of communication devices have allowed running Virtual Reality (VR) and Augmented Reality (AR) applications on those. Nowadays, it is possible to overlay synthetic information on real images, or even to play 3D on-line games on smart phones or some other mobile devices. Hence the use of 3D data for business and specially for education purposes is ubiquitous. Due to always available at hand and always ready to use properties of mobile phones, those are considered as most potential communication devices. The total numbers of mobile phone users are increasing all over the world every day and that makes mobile phones the most suitable device to reach a huge number of end clients either for education or for business purposes. There are different standards, protocols and specifications to establish the communication among different communication devices but there is no initiative taken so far to make it sure that the send data through this communication process will be understood and used by the destination device. Since all the devices are not able to deal with all kind of 3D data formats and it is also not realistic to have different version of the same data to make it compatible with the destination device, it is necessary to have a prevalent solution. The proposed architecture in this paper describes a device and purpose independent 3D data visibility any time anywhere to the right person in suitable format. There is no solution without limitation. The architecture is implemented in a prototype to make an experimental validation of the architecture which also shows the difference between theory and practice.
Smoothie: a solution for device and content independent applications including 3D imaging as content
(2014)
Network landscape of recent time contains many different network technologies, a wide range of end-devices with a large scale of capabilities and power, and an immense quantity of information represented in different data formats. Research on 3D imaging, virtual reality and holographic techniques will result in new user interfaces (UI) for mobile devices and will increase their diversity and variety. A lot of effort is being made in order to establish open, scalable and seamless integration of various technologies and content presentation for different devices including those that are mobile, considering the individual situation of the end user. Till today the research is going on in different parts of the world but the task is not completed yet. The goal of this research work is to find a way to solve the above stated problems by investigating system architectures to provide unconstrained, continuous and personalized access to the content and interactive applications everywhere and at anytime with different devices. As a Solution of the problem considered, a new architecture named “Smoothie” is proposed.
Innovative technologies and concepts will emerge as we move towards a more dynamic, service-based, market-driven infrastructure, where energy efficiency and savings can be facilitated by interactive distribution networks. A new generation of fully interactive Information and Communication Technologies (ICT) infrastructure has to be developed to support the optimal exploitation of the changing, complex business processes and to enable the efficient functioning of the deregulated energy market for the benefit of citizens and businesses. The architecture of such distributed system landscapes must be designed and validated, standards need to be created and widely supported, and comprehensive, reliable IT applications will need to be implemented. The collaboration between a smart house and a smart grid is a promising approach which, with the help of ICT can fully unleash the capabilities of the smart electricity network.
The electrical field (E-field) of the biventricular (BV) stimulation is important for the success of cardiac resynchronization therapy (CRT) in patients with cardiac insufficiency and widened QRS complex.
The aim of the study was to model different pacing and ablation electrodes and to integrate them into a heart model for the static and dynamic simulation of BV stimulation and HF ablation in atrial fibrillation (AF).
The modeling and simulation was carried out using the electromagnetic simulation software CST. Five multipolar left ventricular (LV) electrodes, four bipolar right atrial (RA) electrodes, two right ventricular (RV) electrodes and one HF ablation catheter were modelled. A selection were integrated into the heart rhythm model (Schalk, Offenburg) for the electrical field simulation. The simulation of an AV node ablation at CRT was performed with RA, RV and LV electrodes and integrated ablation catheter with an 8 mm gold tip.
The BV stimulation were performed simultaneously at amplitude of 3 V at the LV electrode and 1 V at the RV electrode with a pulse width of 0.5 ms each. The far-field potential at the RA electrode tip was 32.86 mV and 185.97 mV at a distance of 1 mm from the RA electrode tip. AV node ablation was simulated with an applied power of 5 W at 420 kHz at the distal ablation electrode. The temperature at the catheter tip was 103.87 °C after 5 s ablation time and 37.61 °C at a distance of 2 mm inside the myocardium. After 15 s, the temperature was 118.42 °C and 42.13 °C.
Virtual heart and electrode models as well as the simulations of electrical fields and temperature profiles allow the static and dynamic simulation of atrial synchronous BV stimulation and HF ablation at AF and could be used to optimize the CRT and AF ablation.
Background: The electrical field (E-field) of the biventricular (BV) stimulation is essential for the success of cardiac resynchronization therapy (CRT) in patients with cardiac insufficiency and widened QRS complex. 3D modeling allows the simulation of CRT and high frequency (HF) ablation.
Purpose: The aim of the study was to model different pacing and ablation electrodes and to integrate them into a heart model for the static and dynamic simulation of BV stimulation and HF ablation in atrial fibrillation (AF).
Methods: The modeling and simulation was carried out using the electromagnetic simulation software. Five multipolar left ventricular (LV) electrodes, one epicardial LV electrode, four bipolar right atrial (RA) electrodes, two right ventricular (RV) electrodes and one HF ablation catheter were modeled. Different models of electrodes were integrated into a heart rhythm model for the electrical field simulation (fig.1). The simulation of an AV node ablation at CRT was performed with RA, RV and LV electrodes and integrated ablation catheter with an 8 mm gold tip.
Results: The RV and LV stimulation were performed simultaneously at amplitude of 3 V at the LV electrode and 1 V at the RV electrode, each with a pulse width of 0.5 ms. The far-field potentials generated by the BV stimulations were perceived by the RA electrode. The far-field potential at the RA electrode tip was 32.86 mV. A far-field potential of 185.97 mV resulted at a distance of 1 mm from the RA electrode tip. AV node ablation was simulated with an applied power of 5 W at 420 kHz at the distal 8 mm ablation electrode. The temperature at the catheter tip was 103.87 ° C after 5 s ablation time, 44.17 ° C from the catheter tip in the myocardium and 37.61 ° C at a distance of 2 mm. After 10 s, the temperature at the three measuring points described above was 107.33 ° C, 50.87 ° C, 40.05 ° C and after 15 seconds 118.42 ° C, 55.75 ° C and 42.13 ° C.
Conclusions: Virtual heart and electrode models as well as the simulations of electrical fields and temperature profiles allow the static and dynamic simulation of atrial synchronous BV stimulation and HF ablation at AF. The 3D simulation of the electrical field and temperature profile may be used to optimize the CRT and AF ablation.
WirelessHART protocol was specifically designed for real-time communication in the wireless sensor networks domain for industrial process automation requirements. Whereas the major purpose of WirelessHART is the read-out of sensors with moderate real-time requirements, an increasing demand for integration of actuator applications can be observed. Therefore, it must be verified that the WirelessHART protocol gives sufficient support to real-time industry requirements. As a result, the delay of especially burst and command messages from actuator and sensor nodes to the gateway and vice versa must be analyzed. In this paper, we implemented a WirelessHART network scenario in WirelessHART simulator in NS-2 [8], simulated and analyzed its time characteristics under ideal and noisy conditions. We evaluated the performance of the implementation in order to verify whether the requirements of industrial process and control can be met. This implementation offers an early alternative to expensive test beds for WirelessHART in real-time actuator applications.
Significance of new electrocardiographic parameters to improve cardiac resynchronization therapy
(2011)
Introduction: Oesophageal left heart electrogram (LHE) is a valuable tool providing electrocardiographic parameters for cardiac resynchronization therapy (CRT). It can be utilized to measure left ventricular (LVCD) and intra-leftventricular conduction delays (ILVCD) in heart failure patients to justify implantation of CRT systems. In the follow-up, LHE enables measurement of implant-related interatrial conduction times (IACT) which are the key intervals defining the hemodynamically optimal AV delay (AVD).
Methods: By TOSlim oesophageal electrode and Rostockfilter (Osypka AG, Rheinfelden, Germany), LHE was recorded in 39 heart failure patients (10f, 29m, 65±8yrs., QRS=163±21ms) after implantation of CRT systems according to guidelines. In position of maximal left ventricular deflection, LVCD and ILVCD were measured and compared with QRS width. In position of maximal left atrial deflection (LA), IACT was determined in VDD and DDD operation as interval As-LA and Ap-LA between atrial sense event (As) or stimulus (Ap), resp., and onset of LA. AVD was individualized using SAV =As-LA + 50ms for VDD and PAV=Ap-LA + 50ms for DDD operation.
Results: The CRT patients were characterized by minimal transoesophageal LVCD of 40ms but 73±20ms, at mean, ILVCD of 90±24ms and QRS/LVCD ratio of 2.4±0.6. The measured As-LA of 39±24ms and Ap-LA of 124±26ms resulted into SAV of 89±24ms and PAV of 174±26ms. In case of empirical AVD programming using 120ms for SAV and 180ms for PAV, the LHE revealed inverse sequences of LA and Vp in 4 patients (10%) during VDD and 13 patients (33%) in DDD pacing. In these patients, Vp preceded LA as IACT exceeded the programmed AVD.
Conclusion: Guideline indication of CRT systems is associated with LVCD of 40ms or more. Therefore, individual LVCD offers the minimal target interval that should be reached during left ventricular electrode placement to increase responder rate. Postoperatively, AV delay optimization respecting implant-related IACTs excludes adverse hemodynamic effects.
Cardiac resynchronization therapy with biventricular pacing is an established therapy for heart failure patients with electrical left ventricular desynchronization. The aim of this study was to evaluate left atrial conduction delay, intra left atrial conduction delay, left ventricular conduction delay and intra left ventricular conduction delay in heart failure patients using novel signal averaging transesophageal left heart ECG software.
Methods: 8 heart failure patients with dilated cardiomyopathy (DCM), age 68 ± 9 years, New York Heart Association (NYHA) class 2.9 ± 0.2, 24.8 ± 6.7 % left ventricular ejection fraction, 188.8 ± 15.5 ms QRS duration and 8 heart failure patients with ischaemic cardiomyopathy (ICM), age 67 ± 8 years, NYHA class 2.9 ± 0.3, 32.5 ± 7.4 % left ventricular ejection fraction and 167.6 ± 19.4 ms QRS duration were analysed with transesophageal and transthoracic ECG by Bard LabDuo EP system and novel National Intruments LabView signal averaging ECG software.
Results: The electrical left atrial conduction delay was 71.3 ± 17.6 ms in ICM versus 72.3 ± 12.4 ms in DCM, intra left atrial conduction delay 66.8 ± 8.6 ms in ICM versus 63.4 ± 10.9 ms in DCM and left cardiac AV delay 180.5 ± 32.6 ms in ICM versus 152.4 ± 30.4 ms in DCM. The electrical left ventricular conduction delay was 40.9 ± 7.5 ms in ICM versus 42.6 ± 17 ms in DCM and intra left ventricular conduction delay 105.6 ± 19.3 ms in ICM versus 128.3 ± 24.1 ms in DCM.
Conclusions: Left heart signal averaging ECG can be utilized to analyse left atrial conduction delay, intra left atrial conduction delay, left ventricular conduction delay and intra left ventricular conduction delay to improve patient selection for cardiac resynchronization therapy.
Introduction: Cardiac resynchronization therapy (CRT) with left ventricular (LV) pacing is an established therapy for heart failure (HF) patients (P) with ventricular desynchronisation and reduced LV ejection fraction (EF). The aim of this study was to test the utilization of the transesophageal approach to measure arterial pulse pressure (PP) during LV pacing and electrical interventricular conduction delay (IVCD), to better select patients for CRT.
Methods: 32 HF patients (age 64 ± 10 years; 5 females, 27 males) with New York Heart Association (NYHA) class 2.8 ± 0.6, 27 ± 11 % LV EF and 155 ± 35 ms QRS duration were analysed with semi-invasive left cardiac pacing and electrocardiography. Esophageal TO8 Osypka catheter of 10.5 F diameter was perorally applied to the esophagus and placed in the position of maximum left atrial (LA) deflection and maximum LV deflection to measure PP with VAT or D00 pacing modes.
Results: Temporary transesophageal LV pacing was possible with VAT mode (n=16) and D00 mode (n=16) in all patients. In 15 Δ-PP-responders, PP was higher during LV pacing on than LV pacing off (78.3 ± 26.6 versus 65.9 ± 23.7 mmHg, P < 0.001) and NYHA class improved from 3.1 ± 0.35 to 2.1 ± 0.35 (P < 0.001) during 29 ± 26 month biventricular (BV) pacing follow-up (6 Medtronic and 9 Boston BV pacing devices). In 17 Δ-PP-non-responders, PP was not higher during LV pacing on than LV pacing off (61.5 ± 23.9 versus 60.9 ± 23.5 mmHg, P = 0.066). IVCD was significant longer in Δ-PP-responders than in Δ-PP-non-responders (87 ± 33 ms versus 37± 29 ms, P < 0.001).
Conclusion: Semi-invasive transesophageale LA and LV pacing with D00 and VAT mode and LV electrogram recording may be useful techniques to predict CRT improvement.
Semi-invasive electromechanical target interval to guide left ventricular electrode placement
(2011)
Using guideline parameters for indication of cardiac resynchronization therapy (CRT), only about two thirds of the patients improve clinically. Unfortunately both, surface ECG and echo are uncertain to predict CRT response. To better characterize cardiac desynchronization in heart failure, interventricular (IVCD) and intra-leftventricular conduction delays (ILVCD) were measured by esophageal left ventricular electrogram (LVE). Recordings in 43 CRT patients (34m, 9f, age: 64.7 ± 9.5yrs) evidenced only weak correlation between IVCD and QRS of 0.53 and between ILVCD and QRS of 0.33. This demonstrated that QRS duration is not a reliable indicator of desynchronization. Therefore, the study resulted into development of LVE feature for a programmer with implant support device. It can be used interoperatively to guide the left ventricular electrode location in order to increase responder rate in CRT.
Introduction: Radiofrequency ablation allows successful treatment of most supraventricular reentrant and focal tachycardias and an increasing number of ventricular tachycardias. Different catheter tips are used. While AV nodal reentrant tachycardias require catheters with a tip of 4mm length, an 8 mm tip electrodes will be used for atrial flutter. A pulmonary vein isolation will be performed using 4 mm irrigated tip electrodes to achieve larger and deeper lesions. The need of a tubing set and pump for saline transfusion is a disadvantage of this technique. Gold tip electrodes can alternatively be used to produce increases in lesion size. Aim of this study was to compare RF ablation catheters of exactly the same geometry with either platin-iridum or gold tip.
Methods: Gold provides an almost four-fold thermal conductivity compared with platinum-iridium. The Cerablate G flutter (Osypka AG, Rheinfelden-Herten) is a newly designed radiofrequency ablation catheter with an 8 mm gold tip. Its power delivery was compared with the Cerablate flutter of same geometry but platin-iridium tip. Therefore, in-vitro RF ablations were performed using pork meat in a 0.9% saline solution at 37°C temperature. A pulsed volume flow was generated using a pump to simulate the blood flow. Temperature controlled ablations of 60 seconds using 45, 55 and 65°C and a maximum of 70W RF power were performed.
Results: Using the Osypka HAT300smart ablator, cumulative power of 167, 474 and 672W was delivered with gold tip against 121, 227 and 310 W with platin-iridium tip. By the Stockert SmartAblate G4 ablator, 202, 546 and 1075W was delivered with gold tip against 117, 246 and 394W with platin-iridium using 45, 55 and 65°C temperature.
Conclusion: During in-vitro investigations, the gold tip electrodes allowed a in power delivery increase of 117 up to 173%. Thus, gold tips can be used to increase lesion depth and diameter without cooling equipment.
Today's network landscape consists of quite different network technologies, wide range of end-devices with large scale of capabilities and power, and immense quantity of information and data represented in different formats. Research on 3D imaging, virtual reality and holographic techniques will result in new user interfaces (UI) for mobile devices and will increase their diversity and variety. A lot of efforts are being done in order to establish open, scalable and seamless integration of various technologies and content presentation for different devices including mobile considering individual situation of the end user. This is very difficult because various kinds of devices used by different users or in different times/parallel by the same user which are not predictable and have to be recognized by the system in order to identify device capabilities. Not only the devices but also Content and User Interfaces are big issues because they could include different kinds of data format like text, image, audio, video, 3D Virtual Reality data and other upcoming formats. A very suitable and useful example of the use of such a system is mobile learning because of the large amount of varying devices with significantly different features and functionalities. This is true not only to support different learners, e.g. all learners within one learning community, but also to support the same learner using different equipment parallel and/or at different times. Those applications may be significantly enhanced by including virtual reality content presentation. Whatever the purposes are, it is impossible to develop and adapt content for all kind of devices including mobiles individually due to different capabilities of the devices, cost issues and author‘s requirement. A solution should be found to enable the automation of the content adaptation process.
Environmental Monitoring is an attractive application field for Wireless Sensor Network (WSN). Water Level Monitoring helps to increase the efficiency of water distribution and management. In Pakistan, the world’s largest irrigation system covers 90.000 km of channels which needs to be monitored and managed on different levels. Especially the sensor systems for the small distribution channels need to be low energy and low cost. The distribution presents a technical solution for a communication system which is developed in a research project being co-funded by German Academic Exchange Service (DAAD). The communication module is based on IEEE-802.15.4 transceivers which are enhanced through Wake-On-Radio (WOR) to combine low-energy and real-time behavior. On higher layers, IPv6 (6LoWPAN) and corresponding routing protocols like Routing Protocol for Low power and Lossy Networks (RPL) can extend range of the network. The data are stored in a database and can be viewed online via a web interface. Of course, also automatic data analysis can be performed.
In the dual membrane fuel cell (DM-Cell), protons formed at the anode and oxygen ions formed at the cathode migrate through their respective dense electrolytes to react and form water in a porous composite layer called dual membrane (DM). The DM-Cell concept was experimentally proven (as detailed in Part I of this paper). To describe the electrochemical processes occurring in this novel fuel cell, a mathematical model has been developed which focuses on the DM as the characteristic feature of the DM-Cell. In the model, the porous composite DM is treated as a continuum medium characterized by effective macro-homogeneous properties. To simulate the polarization behavior of the DM-Cell, the potential distribution in the DM is related to the flux of protons and oxygen ions in the conducting phases by introducing kinetic and transport equations into charge balances. Since water pressure may affect the overall formation rate, water mass balances across the DM and transport equations are also considered. The satisfactory comparison with available experimental results suggests that the model provides sound indications on the effects of key design parameters and operating conditions on cell behavior and performance.
Introduction: Patient selection for cardiac resynchronization therapy (CRT) requires quantification of left ventricular conduction delay (LVCD). After implantation of biventricular pacing systems, individual AV delay (AVD) programming is essential to ensure hemodynamic response. To exclude adverse effects, AVD should exceed individual implant-related interatrial conduction times (IACT). As result of a pilot study, we proposed the development of a programmer-based transoesophageal left heart electrogram (LHE) recording to simplify both, LVCD and IACT measurement. This feature was implemented into the Biotronik ICS3000 programmer simultaneously with 3-channel surface ECG.
Methods: A 5F oesophageal electrode was perorally applied in 44 heart failure CRT-D patients (34m, 10f, 65±8 yrs., QRS=162±21ms). In position of maximum left ventricular deflection, oesophageal LVCD was measured between onsets of QRS in surface ECG and oesophageal left ventricular deflection. Then, in position of maximum left atrial deflection (LA), IACT in VDD operation (As-LA) was calculated by difference between programmed AV delay and the measured interval from onset of left atrial deflection to ventricular stimulus in the oesophageal electrogram. IACT in DDD operation (Ap-LA) was measured between atrial stimulus and LA..
Results: LVCD of the CRT patients was characterized by a minimum of 47ms with mean of 69±23ms. As-LA and Ap-LA were found to be 41±23ms and 125±25ms, resp., at mean. In 7 patients (15,9%), IACT measurement in DDD operation uncovered adverse AVD if left in factory settings. In this cases, Ap-LA exceeded the factory AVD. In 6 patients (13,6%), IACT in VDD operation was less than or equal 10ms indicating the need for short AVD.
Conclusion: Response to CRT requires distinct LVCD and AVD optimization. The ICS3000 oesophageal LHE feature can be utilized to measure LVCD in order to justify selection for CRT. IACT measurement simplifies AV delay optimization in patients with CRT systems irrespective of their make and model.
AV delay (AVD) optimization is mandatory in cardiac resynchronization (CRT) for heart failure. Several time consuming methods exist. We initialized development of left-atrial electrogram (LAE) feature for Biotronik ICS3000 programmer. It can be utilized to approximate optimal AV delay in CRT patients with pacing systems irrespective of make and model. Using this feature, we studied the share of interatrial conduction intervals (IACT) on individual echo AVD in 45 CRT patients (34m, 11f, mean age 69±6yrs.). The percentage of IACT on optimal echo AVD resulted in44.5±22.1% for VDD and 70.7±10.9% for DDD operation. In all patients, optimal echo AVDs exceeded the individual IACT by a duration of 52.5±33.3ms (p<0.001), at mean. Therefore, if AV delay optimization is not possible or not practicable in CRT patients, AVD should be approximated by individually measuring IACT and adding about 50ms.
In the work at hand, we combine a Private Information Retrieval (PIR) protocol with Somewhat Homomorphic Encryption (SHE) and use Searchable Encryption (SE) with the objective to provide security and confidentiality features for a third party cloud security audit. During the auditing process, a third party auditor will act on behalf of a cloud service user to validate the security requirements performed by a cloud service provider. Our concrete contribution consists of developing a PIR protocol which is proceeding directly on a log database of encrypted data and allowing to retrieve a sum or a product of multiple encrypted elements. Subsequently, we concretely apply our new form of PIR protocol to a cloud audit use case where searchable encryption is employed to allow additional confidentiality requirements to the privacy of the user. Exemplarily we are considering and evaluating an audit of client accesses to a controlled resource provided by a cloud service provider.
Economic dispatch is a well-known optimization problem in smart grid systems which aims at minimizing the total cost of power generation among generation units while maintaining some system constraints. Recently, some distributed consensus-based approaches have been proposed to replace traditional centralized calculation. However, existing approaches fail to protect privacy of individual units like cost function parameters, generator constraints, output power levels, etc. In this paper, we show an attack against an existing consensus-based economic dispatch algorithm from [16] assuming semi-honest non-colluding adversaries. Then we propose a simple solution by combining a secure sum protocol and the consensus-based economic dispatch algorithm that guarantees data privacy under the same attacker model. Our Privacy Preserving Economic Dispatch (PPED) protocol is information-theoretically secure.
Gaps in basic math knowledge are among the biggest obstacles to a successful start in university. Students starting their studies in STEM disciplines display significant diversity, “math anxiety” is a widespread phenomenon, and the transition to a self-determined way of studying presents a huge challenge. Universities offer support measures such as preparatory courses. Over the years, Offenburg University realized that with increased diversity, traditional ways of teaching in front of the class have become inefficient. The majority of the students remained inactive and just listened to the teachers’ explanations and the few active participants’ answers.
Since 2013 our new course concept fosters a shift from teaching to active learning on a large scale, involving several hundred participants of our on-site preparatory math courses. This switch to broad active practicing, however, must go hand in hand with providing individual support for an increasingly diverse student body. Meanwhile students bring along their mobile devices, and the training App TeachMatics serves as a facilitator. The course concept has been very well received by both students and teachers.
In public transportation, the motor pool often consists of various different vehicles bought over a duration of many years. Sometimes, they even differ within one batch bought at the same time. This poses a considerable challenge in the storage and allocation of spare parts, especially in the event of damage to a vehicle. Correctly assigning these parts before the vehicle reaches the workshop could significantly reduce both the downtime and, therefore, the actual costs for companies. In order to achieve this, the current software uses a simple probability calculation. To improve the performance, the data of specific companies was analysed, preprocessed and used with several modelling techniques to classify and, therefore, predict the spare parts to be used in the event of a faulty vehicle. We summarize our experience running through the steps of the Cross Industry Standard Process for Data Mining and compare the performance to the previously used probability. Gradient Boosting Trees turned out to be the best modeling technique for this special case.
We report the use of the Raman spectral information of the chemical compound toluene C7H8 as a reference on the analysis of laboratory-prepared and commercially acquired gasoline-ethanol blends. The rate behavior of the characteristic Raman lines of toluene and gasoline has enabled the approximated quantification of this additive in commercial gasoline-ethanol mixtures. This rate behavior has been obtained from the Raman spectra of gasoline-ethanol blends with different proportions of toluene.
All these Raman spectra have been collected by using a self-designed, frequency precise and low-cost Fourier-transform Raman spectrometer (FT-Raman spectrometer) prototype. This FT-Raman prototype has helped to accurately confirm the frequency position of the main characteristic Raman lines of toluene present on the different gasoline-ethanol samples analyzed at smaller proportions than those commonly found in commercial gasoline-ethanol blends. The frequency accuracy validation has been performed by analyzing the same set of toluene samples with two additional state-of-the-art commercial FT-Raman devices. Additionally, the spectral information has been contrasted, with highly-correlated coefficients as a result, with the values of the standard Raman spectrum of toluene.
A polarization mode dispersion measurement set-up based on a Mach-Zehnder Interferometer was realized. Measurements were carried out on short high-birefringent fibers and on long standard telecommunication single-mode fibers. In order to ensure high accurate results, special emphasis was placed on the evaluation of the interference pattern. The procedure will be described in detail and practical measurement results will be presented.
This paper evaluates the implementation of Medium Access Control (MAC) protocols suitable for massive access connectivity in 5G multi-service networks. The access protocol extends multi-packet detection receivers based on Physical Layer Network Coding (PLNC) decoding and Coded Random Access protocols considering practical aspects to implement one-stage MAC protocols for short packet communications in mMTC services. Extensions to enhance data delivery phase in two- stage protocols are also proposed. The assessment of the access protocols is extended under system level simulations where a suitable link to system interface characterization has been taken into account.
Mobile learning (m-learning) can be considered as a new paradigm of e-learning. The developed solution enables the presentation of animations and 3D virtual reality (VR) on mobile devices and is well suited for mobile learning. Difficult relations in physics as well as intricate experiments in optics can be visualised on mobile devices without need for a personal computer. By outsourcing the computational power to a server, the coverage is worldwide.
Due to its numerous application fields and benefits, virtualization has become an interesting and attractive topic in computer and mobile systems, as it promises advantages for security and cost efficiency. However, it may bring additional performance overhead. Recently, CPU virtualization has become more popular for embedded platforms, where the performance overhead is especially critical. In this article, we present the measurements of the performance overhead of the two hypervisors Xen and Jailhouse on ARM processors in the context of the heavy load “Cpuburn-a8” application and compare it to a native Linux system running on ARM processors.
The need to measure basic aerosol parameters has increased dramatically in the last decade. This is due mainly to their harmful effect on the environment and on public health. Legislation requires that particle emissions and ambient levels, workplace particle concentrations and exposure to them are measured to confirm that the defined limits are met and the public is not exposed to harmful concentrations of aerosols.
Climate change and resultant scarcity of water are becoming major challenges for countries around the world. With the advent of Wireless Sensor Networks (WSN) in the last decade and a relatively new concept of Internet of Things (IoT), embedded systems developers are now working on designing control and automation systems that are lower in cost and more sustainable than the existing telemetry systems for monitoring. The Indus river basin in Pakistan has one of the world's largest irrigation systems and it is extremely challenging to design a low-cost embedded system for monitoring and control of waterways that can last for decades. In this paper, we present a hardware design and performance evaluation of a smart water metering solution that is IEEE 802.15.4-compliant. The results show that our hardware design is as powerful as the reference design, but allows for additional flexibility both in hardware and in firmware. The indigenously designed solution has a power added efficiency (PAE) of 24.7% that is expected to last for 351 and 814 days for nodes with and without a power amplifier (PA). Similarly, the results show that a broadband communication (434 MHz) over more than 3km can be supported, which is an important stepping stone for designing a complete coverage solution of large-scale waterways.
Recently, the demand for scalable, efficient and accurate Indoor Positioning Systems (IPS) has seen a rising trend due to their utility in providing Location Based Services (LBS). Visible Light Communication (VLC) based IPS designs, VLC-IPS, leverage Light Emitting Diodes (LEDs) in indoor environments for localization. Among VLC-based designs, Time Difference of Arrival (TDOA) based techniques are shown to provide very low errors in the relative position of receivers. Our considered system consists of five LEDs that act as transmitters and a single receiver (photodiode or image sensor in smart phone) whose position coordinates in an indoor environment are to be determined. As a performance criterion, Cramer Rao Lower Bound (CRLB) is derived for range estimations and the impact of various factors, such as, LED transmission frequency, position of reference LED light, and the number of LED lights, on localization accuracy has been studied. Simulation results show that depending on the optimal values of these factors, location estimation on the order of few centimeters can be realistically achieved.
During the last ten years the development of wireless sensing applications has become more and more attractive. A major reason for this trend is the large quantity of available wireless technologies. The progressing demand on wireless technologies is mainly driven through development from the industrial wireless sensors market. Especially requirements like low energy consumption, a resource saving simple protocol stack and short timing delays between different states of the wireless transceivers are very important for wireless sensors. Bluetooth Low Energy (BLE) is a rather new wireless standard in addition to the traditional Bluetooth standard (Basis rate and enhanced data rate, BR/EDR) [1]. The BLE will completely fulfill these fundamental requirements. First BLE transceiver chips and modules are available and have been tested and implemented in products. In this paper the performance analysis results of a BLE sensor system which is based on the TI transceiver CC2540F [5] will be presented. The results can be taken for further important investigations like lifetime calculations or BLE simulation models.
Finding clusters in high dimensional data is a challenging research problem. Subspace clustering algorithms aim to find clusters in all possible subspaces of the dataset where, a subspace is the subset of dimensions of the data. But exponential increase in the number of subspaces with the dimensionality of data renders most of the algorithms inefficient as well as ineffective. Moreover, these algorithms have ingrained data dependency in the clustering process, thus, parallelization becomes difficult and inefficient. SUBSCALE is a recent subspace clustering algorithm which is scalable with the dimensions and contains independent processing steps which can be exploited through parallelism. In this paper, we aim to leverage, firstly, the computational power of widely available multi-core processors to improve the runtime performance of the SUBSCALE algorithm. The experimental evaluation has shown linear speedup. Secondly, we are developing an approach using graphics processing units (GPUs) for fine-grained data parallelism to accelerate the computation further. First tests of the GPU implementation show very promising results.
In contrast to conventional aortic valve replacement, the Transcatheter Aortic Valve Implantation (TAVI) is a new highly specialist alternative to surgical valve replacement for patients with symptomatic severe aortic stenosis and high operative risk. The procedure was performed in a minimally invasive way and was introduced at the university heart centre, Freiburg – Bad Krozingen in 2008. The results have been getting better and better over the years. The aim of the investigation is the analysis of electrocardiogram conduction time and the electrocardiography changes recorded hours and days after the procedure depending on artificial heart valve models, which may lead to pacemaker implantation, even the analysis of the effectiveness of treatment.
Special implant connection module was developed to combine full features of two commercial heart rhythm simulators, ARSI-4 and Intersim II, into a master-slave teaching system. Seven workstations were equipped with the Carelink and Homemonitoring remote patient monitoring systems. This combination enables in-vitro training of physicians, nurses and students in pace-maker and defibrillator measurements during implantation and individual programming in the follow-up. Thus, extended sets of arrhythmias and electrode problems can be used to simulate problems and their solutions in a wide range of the clinical routine.
Cardiac resynchronization therapy with atrioventricular and interventricular pacing delay optimized biventricular pacing is an established therapy for heart failure patients with sinus rhythm and reduced left ventricular ejection fraction. The aim of the study was to evaluate atrioventricular and interventricular pacing delay optimization in cardiac resynchroniza-tion therapy by transthoracic impedance cardiography in biventricular pacing with different left ventricular electrode po-sition. In biventricular pacing heart failure patients with lateral, posterolateral and anterolateral left ventricular electrode position, the mean optimal atrioventricular sening delay was 108.6 ± 20.3 ms and the mean optimal interventricular pac-ing delay -12.3 ± 25.9 ms. Transthoracic impedance cardiography may be a useful technique to optimize atrioventricular and interventricular pacing delay in biventricular pacing with different left ventricular electrode position.
Existing approaches solving multi-vehicle pickup and delivery problems with soft time windows typically use common benchmark sets to verify their performance. However, there is a gap from these benchmark sets to real world problems with respect to instance size and problem complexity. In this paper we show that a combination of existing approaches together with improved heuristics is able to deal with the instance sizes and complexity of real world problems. The cost savings potential of the heuristics is compared to human dispatching plans generated from the data of a European carrier.
The importance of obtaining simultaneous particle size and concentration values has grown up with continuing discussion of the health effects, of internal combustion engine generated particulate emissions and in particular of Diesel soot emissions. In the present work an aerosol measurement system is described that delivers information about particle size and concentration directly from the undiluted exhaust gas.
Using three laser diodes of different wavelengths which form one parallel light beam, each spectral attenuation is analysed by a single detector and the particle diameter and concentration is evaluated by the use of the Mie theory and shown on-line at a frequency of 1 Hz. The system includes an optical long-path-cell (White principle) with an adjustable path length from 2.5 to 15 m, which allows the analysis within a broad concentration range.
On-line measurements of the particulate emissions in the hot, undiluted exhaust of Diesel engines are presented under stationary and transient engine’s load conditions. Mean particle diameters well below 100 nm are detected for modern Diesel engines. The measured particle concentration corresponds excellently with the traditional gravimetrical measurements of the diluted exhaust. Additionally, measurements of particle emissions (mostly condensed hydricarbons) from a two-stroke engine are presented and discussed.
The prototype of an optical gyro encoder (OGE) has been successfully tested on the NTT telescope in September '93. The OGE consists of a ring laser gyro and a fiber optic gyro with their input axis parallel. The gyro outptu signals are compensated for earth rotation and misalignment and are subsequently integrated to get the angles. An adaptive digital control loop locks the fiber optic gyro to the laser gyro data. Thus the combined output has the precision of the laser gyro and the low noise of the fiber optic gyro. Specifically, the bias stability is better than 2 X 10-3 deg/h, the scale factor accuracy better than 1 ppm, the random walk coefficient better than 5 X 10-4 deg/(root)h and the resolution better than 3 X 10-4 arcsec. The OGE has been mounted in the altitude and in the azimuthy axis of the telescope. The data were compared with the telescope disk encoder data. The test data show that the pointing accuracy is about 1 arcsec and the tracking accuracy 0.1 arcsec over a time of 30 seconds. This accuracy is sufficient for the very large telescope, for instance.
In the last decade, IPv6 over Low power Wireless Personal Area Networks (IEEE802.15.4), also known as 6LoWPAN, has well evolved as a primary contender for short range wireless communications and holds the promise of an Internet of Things, which is completely based on the Internet Protocol. The authors' team has developed a 6LoWPAN protocol stack in C language, the stack without the necessity to use a specific design environment or operating system. It is highly flexible, modular, and portable and can be enhanced by several interesting modules, like a Wake-On-Radio-(WOR) MAC layer or a TLS1.2 based security sublayer. The stack is made available as open source at https://github.com/hso-esk/emb6. It was extensively tested on the Automated Physical Testbed (APTB) for Wireless Systems, which is available in the authors' lab and allows a flexible setup and full control of arbitrary topologies. The results of the measurements demonstrate a very good stability and short-term with long-term performance also under dynamic conditions.
Soccer simulation league is one of the founding leagues of RoboCup. In this paper we discuss the past, present and planned future achievements and changes. Also we summarize the connections and inter-league achievements of this league and provide an overview of the community contributions that made this league successful.
On the possibility to use leaky feeders for positioning in chirp spread spectrum technologies
(2014)
Real Time Localization Systems using electromagnetic waves have significantly evolved during the last years. They also might be used in industrial and in mining environments. Here, topologies might include tunnels, where it might be difficult to ensure the field coverage. Leaky feeder cables are a common solution in case of normal radio communication. In this paper, we study the possibilities to use leaky feeders also for Time-of-Flight based real time localization in such linear topologies, like tunnels, but possibly also for 2D-localization. Theoretical analysis is verified with real-life measurements, which were performed using Chirp Spread Spectrum Technologies.