Refine
Year of publication
- 2012 (38) (remove)
Document Type
- Conference Proceeding (38) (remove)
Conference Type
- Konferenzartikel (28)
- Konferenz-Abstract (8)
- Konferenz-Poster (1)
- Sonstiges (1)
Has Fulltext
- no (38) (remove)
Is part of the Bibliography
- yes (38)
Keywords
- RoboCup (2)
- Signaltechnik (2)
- 2D-TLC (1)
- Aircraft (1)
- Attenuation (1)
- BLE (1)
- Batterie (1)
- Brennstoffzelle (1)
- Bruchmechanik (1)
- Collaborative learning (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (25)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (9)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (3)
- CRT - Campus Research & Transfer (2)
- WLRI - Work-Life Robotics Institute (2)
- Fakultät Wirtschaft (W) (1)
- INES - Institut für nachhaltige Energiesysteme (1)
Open Access
- Open Access (16)
- Closed Access (11)
- Closed (10)
- Bronze (2)
This paper describes the magmaOffenburg 3D simulation team trying to qualify for RoboCup 2012. While last year’s TDP focused on the tool set created for 3D simulation and the support for heterogeneous robot models, this year we focus on the different ways how robot behavior can be defined in the magmaOffenburg framework and how those behaviors can be improved by learning.
We will present the first example of a two-dimensional scanned TLC-plate, measured by use of a diode-array scanner. A spatial resolution of 250 µm was achieved on plate. The system provides real 2D fluorescence and absorption spectra in the wavelength-range from 190 to 1000 nm with a spectral resolution of greater than 1 nm. A mixture of 12 sulphonamides was separated by using a cyanopropyl-coated silica gel plate (Merck, 1.16464) with the solvent mix of methyl tert-butyl ether-methanol-dichloromethane-cyclohexane-NH3 (25%) (48:2:2:1:1, v/v) in the first and with a mixture of water-acetonitrile-dioxane-ethanol (8:2:1:1, v/v) in the second direction. Both developments were carried out over a distance of 70 mm. A separation number (spot capacity) of 259 was calculated. We discussed a new formula for its calculation in 2D-TLC separations. The drawback of this method is that measuring a 2D-TLC plate needs more than 3 h measurement time.
The following paper presents the results of a feasibility study about Bluetooth Low Energy (BLE) based wireless sensors. The development of industrial wireless sensors leads to important demands for the wireless technologies like a low energy consumption and a resource saving simple protocol stack. Bluetooth Low Energy (BLE) is a rather new wireless standard which will completely fulfill these fundamental requirements. A self-designed BLE sensor system has been used to explore the common applicability of BLE for wireless sensor systems. The evaluation results of various analyses with the BLE sensor system are now presented in this paper.
Remote measurement of the physiology, so-called biotelemetry, is a key technology in the modern veterinary medicine. The usage of wireless implants has less impact on the behavior of animals than manual measurement methods and cause less disturbance than wired devices. But, common biotelemetry still uses proprietary communication and power concepts focused on small systems with one animal. Therefore, the University of Applied Sciences Offenburg is developing a low-cost RFID system called muTrans1, which is able to measure ECG, pressure, temperature, oxygen saturation and activity. The muTrans uses an own RFID sensor transponder and standardized commercial components and combines them to a scalable RFID system able to build-up RFID sensor networks with a nearly unlimited size.
In this paper, a complete passive transponder device has been discussed which is meant to monitor leakage in silicone breast implants. The passive tag operates in the HF frequency range of 13.56MHz using RFID ISO 15693 standard. The complete system consists of the transponder, reader and a PC. This paper focusses on the development of such a state of the art passive RFID transponder to monitor the wellness of the silicone breast implants periodically in order to detect leakage in the same. Keyword: RFID (Radio frequency identification device), EM (Electromagnetic) field, Passive Transponder, Silicone breast implants.
Die immer weitreichenderen Anwendungen des Smart Metering und des Smart Grid stellen immer höhere Anforderungen an Kommunikationstechnologien, die die Zielkonflikte aus Echtzeitfähige, Stabilität, Kosten und Energieeffizienz möglichst anwendungsoptimiert und auf einem immer höheren Niveau lösen. Insbesondere im Bereich der so genannten Primärkommunikation zwischen einem Sensor- oder Aktorknoten und einem Datensammler mit Gatewayfunktionalität konnten in den vergangenen Jahren wesentliche Fortschritte erzielt werden. Zu nennen sind hierbei insbesondere die Aktivitäten der ZigBee Alliance rund um den offenen Spezifikationsprozess des ZigBee Smart Energy Profiles (SEP) und der OMS-Gruppe beim ZVEI, die auf dem Wireless M-Bus nach EN13757-4 aufbauen, der sich seinerseits lebhaft und zielgerichtet weiter entwickelt. Der Beitrag diskutiert die vorhandenen Einschränkungen und die verfügbaren Lösungsansätze. Er illustriert diese anhand einiger öffentlich geförderter Projekte, an denen das Team des Autors beteiligt ist.
In the field of smart metering it can be observed that standardized protocol, like Wireless M-Bus or ZigBee, enjoy a rapidly increasing popularity. For the protocol implementations, however, up to now, mostly legacy engineering processes and technologies are used, and modern approaches such as model driven design processes or open software platform are disregarded. Therefore, within the WiMBex project, it shall be demonstrated that it is possible to develop a commercial class Wireless M-Bus implementation following state-of-the art design process and using TinyOS as an open source platform. This contribution describes the overall approach of the project, as well as the state and the first experiences of the current work in progress.
During the last ten years the development of wireless sensing applications has become more and more attractive. A major reason for this trend is the large quantity of available wireless technologies. The progressing demand on wireless technologies is mainly driven through development from the industrial wireless sensors market. Especially requirements like low energy consumption, a resource saving simple protocol stack and short timing delays between different states of the wireless transceivers are very important for wireless sensors. Bluetooth Low Energy (BLE) is a rather new wireless standard in addition to the traditional Bluetooth standard (Basis rate and enhanced data rate, BR/EDR) [1]. The BLE will completely fulfill these fundamental requirements. First BLE transceiver chips and modules are available and have been tested and implemented in products. In this paper the performance analysis results of a BLE sensor system which is based on the TI transceiver CC2540F [5] will be presented. The results can be taken for further important investigations like lifetime calculations or BLE simulation models.
Today's network landscape consists of many different network technologies, a wide range of end-devices with a large scale of capabilities and power, and an immense quantity of information and data represented in different formats. Research on 3D imaging, virtual reality and holographic techniques will result in new user interfaces (UI) for mobile devices and will increase their diversity and variety. In this paper software architecture has been proposed to establish device and content format independent communication, implemented in Language Learning Game (LLG).
Since cabling is very complex and often causes reliability problems in aircrafts new approaches which base on wireless technologies are highly desired. In this paper an innovative communication system is proposed that uses the essential elements of the airframe for data transfer. The communication is based on the wireless standard for Digital Video Broadcasting (DVB) and enables high data rates, which are required for the in-flight entertainment system as an example of use.
This paper analyzes the applicability of existing communication technology on the Smart Grid. In particular it evaluates how networks, e.g. Peer-to-Peer (P2P) and decentralized Virtual Private Network (VPN) can help set up an agent-based system. It is expected that applications on Smart Grid devices will become more powerful and be able to operate without a central control instance. We analyze which requirements agents and Smart Grid devices place on communication systems and validate promising approaches. The main focus is to create a logical overlay network that provides direct communication between network nodes. We provide a comparison of different approaches of P2P networks and mesh-VPNs. Finally the advantages of mesh-VPN for agent-based systems are worked out.
Multi-phase management is crucial for performance and durability of electrochemical cells such as batteries and fuel cells. In this paper we present a generic framework for describing the two-dimensional spatiotemporal evolution of gaseous, liquid and solid phases, as well as their interdependence with interfacial (electro-)chemistry and microstructure in a continuum description. The modeling domain consists of up to seven layers (current collectors, channels, electrodes, separator/membrane), each of which can consist of an arbitrary number of bulk phases (gas, liquid, solid) and connecting interfaces (two-phase or multi-phase boundaries). Bulk and interfacial chemistry is described using global or elementary kinetic reactions. Multi-phase management is coupled to chemistry and to mass and charge transport within bulk phases. The functionality and flexibility of this framework is demonstrated using four application areas in the context of post-lithium-ion batteries and fuel cells, that is, lithium-sulfur (Li-S) cells, lithium-oxygen (Li-O) cells, solid oxide fuel cells (SOFC) and polymer electrolyte membrane fuel cells (PEFC). The results are compared to models available in literature and properties of the generic framework are discussed.
Currently, QRS width and bundle branch block morphology are used as electrocardiographic guideline criterias to selectheart failure (HF) patients with interventricular desynchronization in sinus rhythm (SR) for cardiac resynchronisationtherapy (CRT). Nevertheless, up to 30% of these patients do not benefit from implantation of CRT systems. Esophagealleft ventricular electrogram (LVE) enables semi-invasive measurement of interventricular conduction delays (IVCD)even in patients with atrial fibrillation (AF). To routinely apply this method, a programmer based semi-invasiveautomatic quantification of IVCD should to be developed. Our aims were todefine interventricular conduction delaysby analyzing fractionated left ventricular (LV) deflections in the esophageal left ventricular electrogram of HF patientsin SR or AF.
In 66 HF patients (49 male,17 female, age 65 ± 10 years) a 5F TOslim electrode (Osypka AG, Germany) was perorallyapplied. Using BARD EP Lab, cardiac desynchronization was quantified as interval IVCD between onset of QRS insurface ECG and the investigator-determined onset of the left ventricular deflection in LVE. IVCD was compared withthe intervals between QRS onset and the first maximum (IVCDm1) and between QRS onset and the second maximum(IVCDm2) of the LV complex.
QRS of 173 ± 26 ms was linked with empirical IVCD of 75 ± 25 ms, at mean. First and second LV maximum could beascertained beyond doubt in all patients. Significant correlations of the p<0,01 level were found between IVCD and theIVCDm1 of 96 ± 28 ms as well as between IVCD and the IVCDm2 of 147 ± 31 ms, at mean. To standardize automatic measurement of interventricular conduction delays with respect to patients with fractionatedLV complexes, the first maximum of the LV deflection should be utilized to qualify the IVCD of HF patients with sinusrhythm and atrial fibrillation.
Experiences with a telecare platform integration of ZigBee sensors into a middleware platform
(2012)
Cardiac resynchronization therapy (CRT) with biventricular (BV) pacing is an established therapy in approximately two-thirds of symptomatic heart failure (HF) patients (P) with left bundle branch block (LBBB). The aim of this study was to evaluate left atrial (LA) conduction delay (LACD) and left ventricular (LV) conduction delay (LVCD) using pre-implantational transesophageal electrocardiography (ECG) in sinus rhythm (SR) CRT responder (R) and non-responder (NR).
Methods: SR HF P (n=52, age 63.6±10.4 years; 6 females, 46 males) with New York Heart Association (NYHA) class 3.0±0.2, 24.4±7.1 % LV ejection fraction and 171.2±37.6 ms QRS duration (QRSD) were measured by bipolar filtered transesophageal LA and LV ECG recording with hemispherical electrodes (HE) TO catheter (Osypka AG, Rheinfelden, Germany). LACD was measured between onset of P-wave in the surface ECG and onset of LA deflection in the LA ECG. LVCD was measured between onset of QRS in the surface ECG and onset of LV deflection in the LV ECG.
Results: There were 78.8 % SR CRT R (n=41) with 171.2±36.9 ms QRSD, 73.3±25.7 ms LACD, 80.0±24.0 ms LVCD and 2.3±0.5 QRSD-LVCD-ratio. SR CRT R QRSD correlated with LACD (r=0.688, P<0.001) and LVCD (r=0.699, P<0.001). There were 21.2 % SR CRT NR (n=11) with 153.4±22.4 ms QRSD (P=0.133), 69.8±24.8 ms LACD (n=6, P=0.767), 54.2±31.0 ms LVCD (P<0.0046) and 3.9±2.5 QRSD-LVCD-ratio (P<0.001). SR CRT NR QRSD not corre-lated with IACD (r=-0.218, P=0.678) and IVCD (r=0.042, P=0.903). During a 22.8±21.3 month CRT follow-up, the CRT R NYHA class improved from 3.1±0.3 to 1.9±0.3 (P<0.001). In CRT NR, NYHA class not improved (2.9±0.4 to 2.9±0.2, P=1) during 11.2±9.8 months BV pacing.
Conclusions: Transesophageal LA and LV ECG with HE can be utilized to analyse LACD and LVCD in HF P. Pre-implantational LVCD and QRSD-LVCD-ratio may be additional useful parameters to improve P selection for SR CRT.
Capture threshold (CT) for transesophageal left atrial (LA) pacing (TLAP) and transesophageal left ventricular (LV) pacing (TLVP) with conventional cylindrical electrodes (CE) are higher than TLAP feeling threshold (FT). Purpose of the study was to evaluate focused TLAP CT and FT for supraventricular tachycardia (SVT) initiation and focused TLVP CT for cardiac resynchronisation therapy (CRT) simulation.
Methods: SVT initiation in patients (P) with palpitations (n=49, age 47 ± 17 years) was analysed during spontaneous rhythm and during focused bipolar TLAP with atrial constant current stimulus output, distal CE and three or seven 6 mm hemispherical electrodes (HE) (TO, Osypka AG, Rheinfelden, Germany). CRT simulation in heart failure P (n=75, age 62 ± 11 years) was evaluated by focused bipolar TLAP and/or TLVP with ventricular constant voltage stimulus output and different pacing mode.
Results: Focused electrical pacing field between CE and HE (n=28) allowed low threshold TLAP with 8.0 ± 2.6 mA CT at 9.9 ms stimulus duration (SD) which was lower than 9.2 ± 4.5 mA FT at 9.9 ms SD. Focused electrical pacing field between HE and HE (n=21) allowed low threshold TLAP with 8.1 ± 2.2 mA CT at 9.9 ms SD which was lower than 9.8 ± 5.0 mA FT at 9.9 ms SD. SVT initiation by programmed AAI TLAP was possible in 23 P and not possible in 26 P. CRT simulation was evaluated with TLAP and TLVP with VAT, D00 and V00 pacing mode and 95.5 ± 10.9 V TLVP CT at 4.0 ms SD.
Conclusions: Programmed focused AAI TLAP allowed initiation of SVT with very low CT and high FT and focused electrical pacing field between CE-HE and HE-HE.CRT simulation with focused TLAP and/or TLVP with VAT, D00 and V00 pacing mode may be a useful technique to detect responders to CRT.