Refine
Year of publication
Document Type
- Conference Proceeding (453) (remove)
Conference Type
- Konferenzartikel (288)
- Konferenz-Abstract (76)
- Konferenzband (57)
- Sonstiges (23)
- Konferenz-Poster (9)
Language
- English (303)
- German (148)
- Multiple languages (1)
- Russian (1)
Keywords
- Mikroelektronik (56)
- RoboCup (20)
- Kommunikation (7)
- Applikation (5)
- E-Learning (5)
- Eingebettetes System (5)
- Herzkrankheit (5)
- Brennstoffzelle (4)
- CST (4)
- Energieversorgung (4)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (453) (remove)
Open Access
- Open Access (234)
- Closed Access (151)
- Bronze (130)
- Closed (61)
- Diamond (1)
- Grün (1)
RFID- Frontend ISO 15693
(2008)
Introduction: Radiofrequency ablation allows successful treatment of most supraventricular reentrant and focal tachycardias and an increasing number of ventricular tachycardias. Different catheter tips are used. While AV nodal reentrant tachycardias require catheters with a tip of 4mm length, an 8 mm tip electrodes will be used for atrial flutter. A pulmonary vein isolation will be performed using 4 mm irrigated tip electrodes to achieve larger and deeper lesions. The need of a tubing set and pump for saline transfusion is a disadvantage of this technique. Gold tip electrodes can alternatively be used to produce increases in lesion size. Aim of this study was to compare RF ablation catheters of exactly the same geometry with either platin-iridum or gold tip.
Methods: Gold provides an almost four-fold thermal conductivity compared with platinum-iridium. The Cerablate G flutter (Osypka AG, Rheinfelden-Herten) is a newly designed radiofrequency ablation catheter with an 8 mm gold tip. Its power delivery was compared with the Cerablate flutter of same geometry but platin-iridium tip. Therefore, in-vitro RF ablations were performed using pork meat in a 0.9% saline solution at 37°C temperature. A pulsed volume flow was generated using a pump to simulate the blood flow. Temperature controlled ablations of 60 seconds using 45, 55 and 65°C and a maximum of 70W RF power were performed.
Results: Using the Osypka HAT300smart ablator, cumulative power of 167, 474 and 672W was delivered with gold tip against 121, 227 and 310 W with platin-iridium tip. By the Stockert SmartAblate G4 ablator, 202, 546 and 1075W was delivered with gold tip against 117, 246 and 394W with platin-iridium using 45, 55 and 65°C temperature.
Conclusion: During in-vitro investigations, the gold tip electrodes allowed a in power delivery increase of 117 up to 173%. Thus, gold tips can be used to increase lesion depth and diameter without cooling equipment.
Today's network landscape consists of quite different network technologies, wide range of end-devices with large scale of capabilities and power, and immense quantity of information and data represented in different formats. Research on 3D imaging, virtual reality and holographic techniques will result in new user interfaces (UI) for mobile devices and will increase their diversity and variety. A lot of efforts are being done in order to establish open, scalable and seamless integration of various technologies and content presentation for different devices including mobile considering individual situation of the end user. This is very difficult because various kinds of devices used by different users or in different times/parallel by the same user which are not predictable and have to be recognized by the system in order to identify device capabilities. Not only the devices but also Content and User Interfaces are big issues because they could include different kinds of data format like text, image, audio, video, 3D Virtual Reality data and other upcoming formats. A very suitable and useful example of the use of such a system is mobile learning because of the large amount of varying devices with significantly different features and functionalities. This is true not only to support different learners, e.g. all learners within one learning community, but also to support the same learner using different equipment parallel and/or at different times. Those applications may be significantly enhanced by including virtual reality content presentation. Whatever the purposes are, it is impossible to develop and adapt content for all kind of devices including mobiles individually due to different capabilities of the devices, cost issues and author‘s requirement. A solution should be found to enable the automation of the content adaptation process.
In dieser Arbeit wurde eine USB-Schnittstelle für ein bestehendes Mikrocontroller System FHOP realisiert. Im aktuellen Stand funktioniert das Design zuverlässig in Low Speed Konfiguration. Im Full Speed gibt es noch einige Schwierigkeiten, denn die Kommunikation bricht nach einigen Paket-Transfers zusammen. Durch das Emulieren des Designs auf FPGA wurde die Funktion nachgewiesen. Die nächste Aufgabe wird sein, die Hardware zu optimieren, damit das USB-Modul auch im Full Speed zuverlässig funktioniert. Zusätzlich wird die Software auf der PC Seite optimiert, um höhere Übertragungsraten zu erzielen.
Environmental Monitoring is an attractive application field for Wireless Sensor Network (WSN). Water Level Monitoring helps to increase the efficiency of water distribution and management. In Pakistan, the world’s largest irrigation system covers 90.000 km of channels which needs to be monitored and managed on different levels. Especially the sensor systems for the small distribution channels need to be low energy and low cost. The distribution presents a technical solution for a communication system which is developed in a research project being co-funded by German Academic Exchange Service (DAAD). The communication module is based on IEEE-802.15.4 transceivers which are enhanced through Wake-On-Radio (WOR) to combine low-energy and real-time behavior. On higher layers, IPv6 (6LoWPAN) and corresponding routing protocols like Routing Protocol for Low power and Lossy Networks (RPL) can extend range of the network. The data are stored in a database and can be viewed online via a web interface. Of course, also automatic data analysis can be performed.
In the dual membrane fuel cell (DM-Cell), protons formed at the anode and oxygen ions formed at the cathode migrate through their respective dense electrolytes to react and form water in a porous composite layer called dual membrane (DM). The DM-Cell concept was experimentally proven (as detailed in Part I of this paper). To describe the electrochemical processes occurring in this novel fuel cell, a mathematical model has been developed which focuses on the DM as the characteristic feature of the DM-Cell. In the model, the porous composite DM is treated as a continuum medium characterized by effective macro-homogeneous properties. To simulate the polarization behavior of the DM-Cell, the potential distribution in the DM is related to the flux of protons and oxygen ions in the conducting phases by introducing kinetic and transport equations into charge balances. Since water pressure may affect the overall formation rate, water mass balances across the DM and transport equations are also considered. The satisfactory comparison with available experimental results suggests that the model provides sound indications on the effects of key design parameters and operating conditions on cell behavior and performance.
Introduction: Patient selection for cardiac resynchronization therapy (CRT) requires quantification of left ventricular conduction delay (LVCD). After implantation of biventricular pacing systems, individual AV delay (AVD) programming is essential to ensure hemodynamic response. To exclude adverse effects, AVD should exceed individual implant-related interatrial conduction times (IACT). As result of a pilot study, we proposed the development of a programmer-based transoesophageal left heart electrogram (LHE) recording to simplify both, LVCD and IACT measurement. This feature was implemented into the Biotronik ICS3000 programmer simultaneously with 3-channel surface ECG.
Methods: A 5F oesophageal electrode was perorally applied in 44 heart failure CRT-D patients (34m, 10f, 65±8 yrs., QRS=162±21ms). In position of maximum left ventricular deflection, oesophageal LVCD was measured between onsets of QRS in surface ECG and oesophageal left ventricular deflection. Then, in position of maximum left atrial deflection (LA), IACT in VDD operation (As-LA) was calculated by difference between programmed AV delay and the measured interval from onset of left atrial deflection to ventricular stimulus in the oesophageal electrogram. IACT in DDD operation (Ap-LA) was measured between atrial stimulus and LA..
Results: LVCD of the CRT patients was characterized by a minimum of 47ms with mean of 69±23ms. As-LA and Ap-LA were found to be 41±23ms and 125±25ms, resp., at mean. In 7 patients (15,9%), IACT measurement in DDD operation uncovered adverse AVD if left in factory settings. In this cases, Ap-LA exceeded the factory AVD. In 6 patients (13,6%), IACT in VDD operation was less than or equal 10ms indicating the need for short AVD.
Conclusion: Response to CRT requires distinct LVCD and AVD optimization. The ICS3000 oesophageal LHE feature can be utilized to measure LVCD in order to justify selection for CRT. IACT measurement simplifies AV delay optimization in patients with CRT systems irrespective of their make and model.
AV delay (AVD) optimization is mandatory in cardiac resynchronization (CRT) for heart failure. Several time consuming methods exist. We initialized development of left-atrial electrogram (LAE) feature for Biotronik ICS3000 programmer. It can be utilized to approximate optimal AV delay in CRT patients with pacing systems irrespective of make and model. Using this feature, we studied the share of interatrial conduction intervals (IACT) on individual echo AVD in 45 CRT patients (34m, 11f, mean age 69±6yrs.). The percentage of IACT on optimal echo AVD resulted in44.5±22.1% for VDD and 70.7±10.9% for DDD operation. In all patients, optimal echo AVDs exceeded the individual IACT by a duration of 52.5±33.3ms (p<0.001), at mean. Therefore, if AV delay optimization is not possible or not practicable in CRT patients, AVD should be approximated by individually measuring IACT and adding about 50ms.
In the work at hand, we combine a Private Information Retrieval (PIR) protocol with Somewhat Homomorphic Encryption (SHE) and use Searchable Encryption (SE) with the objective to provide security and confidentiality features for a third party cloud security audit. During the auditing process, a third party auditor will act on behalf of a cloud service user to validate the security requirements performed by a cloud service provider. Our concrete contribution consists of developing a PIR protocol which is proceeding directly on a log database of encrypted data and allowing to retrieve a sum or a product of multiple encrypted elements. Subsequently, we concretely apply our new form of PIR protocol to a cloud audit use case where searchable encryption is employed to allow additional confidentiality requirements to the privacy of the user. Exemplarily we are considering and evaluating an audit of client accesses to a controlled resource provided by a cloud service provider.
Economic dispatch is a well-known optimization problem in smart grid systems which aims at minimizing the total cost of power generation among generation units while maintaining some system constraints. Recently, some distributed consensus-based approaches have been proposed to replace traditional centralized calculation. However, existing approaches fail to protect privacy of individual units like cost function parameters, generator constraints, output power levels, etc. In this paper, we show an attack against an existing consensus-based economic dispatch algorithm from [16] assuming semi-honest non-colluding adversaries. Then we propose a simple solution by combining a secure sum protocol and the consensus-based economic dispatch algorithm that guarantees data privacy under the same attacker model. Our Privacy Preserving Economic Dispatch (PPED) protocol is information-theoretically secure.
Gaps in basic math knowledge are among the biggest obstacles to a successful start in university. Students starting their studies in STEM disciplines display significant diversity, “math anxiety” is a widespread phenomenon, and the transition to a self-determined way of studying presents a huge challenge. Universities offer support measures such as preparatory courses. Over the years, Offenburg University realized that with increased diversity, traditional ways of teaching in front of the class have become inefficient. The majority of the students remained inactive and just listened to the teachers’ explanations and the few active participants’ answers.
Since 2013 our new course concept fosters a shift from teaching to active learning on a large scale, involving several hundred participants of our on-site preparatory math courses. This switch to broad active practicing, however, must go hand in hand with providing individual support for an increasingly diverse student body. Meanwhile students bring along their mobile devices, and the training App TeachMatics serves as a facilitator. The course concept has been very well received by both students and teachers.
In public transportation, the motor pool often consists of various different vehicles bought over a duration of many years. Sometimes, they even differ within one batch bought at the same time. This poses a considerable challenge in the storage and allocation of spare parts, especially in the event of damage to a vehicle. Correctly assigning these parts before the vehicle reaches the workshop could significantly reduce both the downtime and, therefore, the actual costs for companies. In order to achieve this, the current software uses a simple probability calculation. To improve the performance, the data of specific companies was analysed, preprocessed and used with several modelling techniques to classify and, therefore, predict the spare parts to be used in the event of a faulty vehicle. We summarize our experience running through the steps of the Cross Industry Standard Process for Data Mining and compare the performance to the previously used probability. Gradient Boosting Trees turned out to be the best modeling technique for this special case.
We report the use of the Raman spectral information of the chemical compound toluene C7H8 as a reference on the analysis of laboratory-prepared and commercially acquired gasoline-ethanol blends. The rate behavior of the characteristic Raman lines of toluene and gasoline has enabled the approximated quantification of this additive in commercial gasoline-ethanol mixtures. This rate behavior has been obtained from the Raman spectra of gasoline-ethanol blends with different proportions of toluene.
All these Raman spectra have been collected by using a self-designed, frequency precise and low-cost Fourier-transform Raman spectrometer (FT-Raman spectrometer) prototype. This FT-Raman prototype has helped to accurately confirm the frequency position of the main characteristic Raman lines of toluene present on the different gasoline-ethanol samples analyzed at smaller proportions than those commonly found in commercial gasoline-ethanol blends. The frequency accuracy validation has been performed by analyzing the same set of toluene samples with two additional state-of-the-art commercial FT-Raman devices. Additionally, the spectral information has been contrasted, with highly-correlated coefficients as a result, with the values of the standard Raman spectrum of toluene.
A polarization mode dispersion measurement set-up based on a Mach-Zehnder Interferometer was realized. Measurements were carried out on short high-birefringent fibers and on long standard telecommunication single-mode fibers. In order to ensure high accurate results, special emphasis was placed on the evaluation of the interference pattern. The procedure will be described in detail and practical measurement results will be presented.
This paper evaluates the implementation of Medium Access Control (MAC) protocols suitable for massive access connectivity in 5G multi-service networks. The access protocol extends multi-packet detection receivers based on Physical Layer Network Coding (PLNC) decoding and Coded Random Access protocols considering practical aspects to implement one-stage MAC protocols for short packet communications in mMTC services. Extensions to enhance data delivery phase in two- stage protocols are also proposed. The assessment of the access protocols is extended under system level simulations where a suitable link to system interface characterization has been taken into account.
Mobile learning (m-learning) can be considered as a new paradigm of e-learning. The developed solution enables the presentation of animations and 3D virtual reality (VR) on mobile devices and is well suited for mobile learning. Difficult relations in physics as well as intricate experiments in optics can be visualised on mobile devices without need for a personal computer. By outsourcing the computational power to a server, the coverage is worldwide.
Due to its numerous application fields and benefits, virtualization has become an interesting and attractive topic in computer and mobile systems, as it promises advantages for security and cost efficiency. However, it may bring additional performance overhead. Recently, CPU virtualization has become more popular for embedded platforms, where the performance overhead is especially critical. In this article, we present the measurements of the performance overhead of the two hypervisors Xen and Jailhouse on ARM processors in the context of the heavy load “Cpuburn-a8” application and compare it to a native Linux system running on ARM processors.
The need to measure basic aerosol parameters has increased dramatically in the last decade. This is due mainly to their harmful effect on the environment and on public health. Legislation requires that particle emissions and ambient levels, workplace particle concentrations and exposure to them are measured to confirm that the defined limits are met and the public is not exposed to harmful concentrations of aerosols.
Climate change and resultant scarcity of water are becoming major challenges for countries around the world. With the advent of Wireless Sensor Networks (WSN) in the last decade and a relatively new concept of Internet of Things (IoT), embedded systems developers are now working on designing control and automation systems that are lower in cost and more sustainable than the existing telemetry systems for monitoring. The Indus river basin in Pakistan has one of the world's largest irrigation systems and it is extremely challenging to design a low-cost embedded system for monitoring and control of waterways that can last for decades. In this paper, we present a hardware design and performance evaluation of a smart water metering solution that is IEEE 802.15.4-compliant. The results show that our hardware design is as powerful as the reference design, but allows for additional flexibility both in hardware and in firmware. The indigenously designed solution has a power added efficiency (PAE) of 24.7% that is expected to last for 351 and 814 days for nodes with and without a power amplifier (PA). Similarly, the results show that a broadband communication (434 MHz) over more than 3km can be supported, which is an important stepping stone for designing a complete coverage solution of large-scale waterways.
Recently, the demand for scalable, efficient and accurate Indoor Positioning Systems (IPS) has seen a rising trend due to their utility in providing Location Based Services (LBS). Visible Light Communication (VLC) based IPS designs, VLC-IPS, leverage Light Emitting Diodes (LEDs) in indoor environments for localization. Among VLC-based designs, Time Difference of Arrival (TDOA) based techniques are shown to provide very low errors in the relative position of receivers. Our considered system consists of five LEDs that act as transmitters and a single receiver (photodiode or image sensor in smart phone) whose position coordinates in an indoor environment are to be determined. As a performance criterion, Cramer Rao Lower Bound (CRLB) is derived for range estimations and the impact of various factors, such as, LED transmission frequency, position of reference LED light, and the number of LED lights, on localization accuracy has been studied. Simulation results show that depending on the optimal values of these factors, location estimation on the order of few centimeters can be realistically achieved.
During the last ten years the development of wireless sensing applications has become more and more attractive. A major reason for this trend is the large quantity of available wireless technologies. The progressing demand on wireless technologies is mainly driven through development from the industrial wireless sensors market. Especially requirements like low energy consumption, a resource saving simple protocol stack and short timing delays between different states of the wireless transceivers are very important for wireless sensors. Bluetooth Low Energy (BLE) is a rather new wireless standard in addition to the traditional Bluetooth standard (Basis rate and enhanced data rate, BR/EDR) [1]. The BLE will completely fulfill these fundamental requirements. First BLE transceiver chips and modules are available and have been tested and implemented in products. In this paper the performance analysis results of a BLE sensor system which is based on the TI transceiver CC2540F [5] will be presented. The results can be taken for further important investigations like lifetime calculations or BLE simulation models.
Optische Navigationssysteme weisen bisher eine eindeutige Trennung zwischen nachverfolgendem Gerät (Tool Tracker) und nachverfolgten Geräten (Tracked Tools) auf. In dieser Arbeit wird ein neues Konzept vorgestellt, dass diese Trennung aufhebt: Jedes Tracked Tool ist gleichzeitig auch Tool Tracker und besteht aus Marker-LEDs sowie mindestens einer Kamera, mit deren Hilfe andere Tracker in Lage und Orientierung nachverfolgt werden können. Bei Verwendung von nur einer Kamera geschieht dies mittels Pose Estimation, ab zwei Kameras werden die Marker-LEDs trianguliert. Diese Arbeit beinhaltet die Vorstellung des neuen Peer-To-Peer-Tracking-Konzepts, einen sehr schnellen Pose-Estimation-Algorithmus für beliebig viele Marker sowie die Klärung der Frage, ob die mit Pose Estimation erreichbare Genauigkeit vergleichbar mit der eines Stereo-Kamera-Systems ist und den Anforderungen an die chirurgische Navigation gerecht wird.
Finding clusters in high dimensional data is a challenging research problem. Subspace clustering algorithms aim to find clusters in all possible subspaces of the dataset where, a subspace is the subset of dimensions of the data. But exponential increase in the number of subspaces with the dimensionality of data renders most of the algorithms inefficient as well as ineffective. Moreover, these algorithms have ingrained data dependency in the clustering process, thus, parallelization becomes difficult and inefficient. SUBSCALE is a recent subspace clustering algorithm which is scalable with the dimensions and contains independent processing steps which can be exploited through parallelism. In this paper, we aim to leverage, firstly, the computational power of widely available multi-core processors to improve the runtime performance of the SUBSCALE algorithm. The experimental evaluation has shown linear speedup. Secondly, we are developing an approach using graphics processing units (GPUs) for fine-grained data parallelism to accelerate the computation further. First tests of the GPU implementation show very promising results.
In contrast to conventional aortic valve replacement, the Transcatheter Aortic Valve Implantation (TAVI) is a new highly specialist alternative to surgical valve replacement for patients with symptomatic severe aortic stenosis and high operative risk. The procedure was performed in a minimally invasive way and was introduced at the university heart centre, Freiburg – Bad Krozingen in 2008. The results have been getting better and better over the years. The aim of the investigation is the analysis of electrocardiogram conduction time and the electrocardiography changes recorded hours and days after the procedure depending on artificial heart valve models, which may lead to pacemaker implantation, even the analysis of the effectiveness of treatment.
Special implant connection module was developed to combine full features of two commercial heart rhythm simulators, ARSI-4 and Intersim II, into a master-slave teaching system. Seven workstations were equipped with the Carelink and Homemonitoring remote patient monitoring systems. This combination enables in-vitro training of physicians, nurses and students in pace-maker and defibrillator measurements during implantation and individual programming in the follow-up. Thus, extended sets of arrhythmias and electrode problems can be used to simulate problems and their solutions in a wide range of the clinical routine.
Die Verarbeitung analoger Signale durch digitale Techniken ist durch die enorme Leistungsfähigkeit der Prozessoren zwischenzeitlich zum Standard geworden. Eine hinreichende Genauigkeit der digitalen Verarbeitung kann durch Wahl der notwendigen Wortbreite relativ einfach bewerkstelligt werden, wobei der Aufwand mit zunehmender Wortbreite linear, teilweise auch quadratisch steigt. Zum Flaschenhals in der Verarbeitung wird aber häufig die Wandlung der analog vorliegenden Signale in digitale Signale, ebenso die Rückwandlung der digitalen Signale in analoge Spannungs- oder Stromverläufe. Der Aufwand für diese teils analogen, teils digitalen Systeme steigt oft exponentiell mit der geforderten Genauigkeit bzw. Auflösung der Systeme und erfordert in konventioneller Technik bei hoher Auflösung aufwendige Maßnahmen auf dem Chip. Oversampling- und Rauschfärbungs-Methoden sind in der Verarbeitung von Audio-Signalen schon seit langem probate Mittel, um die Auflösung mit moderatem Aufwand zu erhöhen. Derartige Techniken werden zwischenzeitlich auch gerne im Bereich der Antriebstechnik, wo die Anforderungen an die erforderliche Positioniergenauigkeit zunehmen, eingesetzt. Ziel des Vortrags ist eine leicht verständliche Einführung in die Themengebiete der Überabtastung und der Rauschfärbung und ihre Anwendung im Hinblick auf Rundungsvorgänge im digitalen Bereich, in D/A-Wandlern und A/D-Wandlern vom Delta-Sigma-Typ.
Cardiac resynchronization therapy with atrioventricular and interventricular pacing delay optimized biventricular pacing is an established therapy for heart failure patients with sinus rhythm and reduced left ventricular ejection fraction. The aim of the study was to evaluate atrioventricular and interventricular pacing delay optimization in cardiac resynchroniza-tion therapy by transthoracic impedance cardiography in biventricular pacing with different left ventricular electrode po-sition. In biventricular pacing heart failure patients with lateral, posterolateral and anterolateral left ventricular electrode position, the mean optimal atrioventricular sening delay was 108.6 ± 20.3 ms and the mean optimal interventricular pac-ing delay -12.3 ± 25.9 ms. Transthoracic impedance cardiography may be a useful technique to optimize atrioventricular and interventricular pacing delay in biventricular pacing with different left ventricular electrode position.
Existing approaches solving multi-vehicle pickup and delivery problems with soft time windows typically use common benchmark sets to verify their performance. However, there is a gap from these benchmark sets to real world problems with respect to instance size and problem complexity. In this paper we show that a combination of existing approaches together with improved heuristics is able to deal with the instance sizes and complexity of real world problems. The cost savings potential of the heuristics is compared to human dispatching plans generated from the data of a European carrier.
The importance of obtaining simultaneous particle size and concentration values has grown up with continuing discussion of the health effects, of internal combustion engine generated particulate emissions and in particular of Diesel soot emissions. In the present work an aerosol measurement system is described that delivers information about particle size and concentration directly from the undiluted exhaust gas.
Using three laser diodes of different wavelengths which form one parallel light beam, each spectral attenuation is analysed by a single detector and the particle diameter and concentration is evaluated by the use of the Mie theory and shown on-line at a frequency of 1 Hz. The system includes an optical long-path-cell (White principle) with an adjustable path length from 2.5 to 15 m, which allows the analysis within a broad concentration range.
On-line measurements of the particulate emissions in the hot, undiluted exhaust of Diesel engines are presented under stationary and transient engine’s load conditions. Mean particle diameters well below 100 nm are detected for modern Diesel engines. The measured particle concentration corresponds excellently with the traditional gravimetrical measurements of the diluted exhaust. Additionally, measurements of particle emissions (mostly condensed hydricarbons) from a two-stroke engine are presented and discussed.
The prototype of an optical gyro encoder (OGE) has been successfully tested on the NTT telescope in September '93. The OGE consists of a ring laser gyro and a fiber optic gyro with their input axis parallel. The gyro outptu signals are compensated for earth rotation and misalignment and are subsequently integrated to get the angles. An adaptive digital control loop locks the fiber optic gyro to the laser gyro data. Thus the combined output has the precision of the laser gyro and the low noise of the fiber optic gyro. Specifically, the bias stability is better than 2 X 10-3 deg/h, the scale factor accuracy better than 1 ppm, the random walk coefficient better than 5 X 10-4 deg/(root)h and the resolution better than 3 X 10-4 arcsec. The OGE has been mounted in the altitude and in the azimuthy axis of the telescope. The data were compared with the telescope disk encoder data. The test data show that the pointing accuracy is about 1 arcsec and the tracking accuracy 0.1 arcsec over a time of 30 seconds. This accuracy is sufficient for the very large telescope, for instance.
Den Hauptbestandteil des Operationssystems stellt der Zugriff auf SD-Karten mit dem Dateisystem FAT16 von Microsoft dar. Für die Bedienung wurde ein Kommandozeileninterpreter implementiert. Als Ein- und Ausgabegerät dient ein PC mit einem speziellen Terminalprogramm, welcher über USB mit dem Emulationsboard des SIRIUS Softcores verbunden ist. Das System wird über die Eingabe von Befehlen am Terminal gesteuert.
Der SIRIUS Softcore kann nur vom Flash des Emulationsboards booten. Da das Betriebssystem selbst jedoch auf der SD-Karte gespeichert werden soll, ist ein Basis-Betriebssystem erforderlich, welches im Flash abgelegt ist. Das Basis-Betriebssystem lädt gleich nach dem Start das eigentliche Betriebssystem von der SD-Karte. Falls jedoch keine SD-Karte gesteckt ist, ermöglicht das Basis-Betriebssystem mit einem Kommandozeileninterpreter einige Grundfunktionen.
In the last decade, IPv6 over Low power Wireless Personal Area Networks (IEEE802.15.4), also known as 6LoWPAN, has well evolved as a primary contender for short range wireless communications and holds the promise of an Internet of Things, which is completely based on the Internet Protocol. The authors' team has developed a 6LoWPAN protocol stack in C language, the stack without the necessity to use a specific design environment or operating system. It is highly flexible, modular, and portable and can be enhanced by several interesting modules, like a Wake-On-Radio-(WOR) MAC layer or a TLS1.2 based security sublayer. The stack is made available as open source at https://github.com/hso-esk/emb6. It was extensively tested on the Automated Physical Testbed (APTB) for Wireless Systems, which is available in the authors' lab and allows a flexible setup and full control of arbitrary topologies. The results of the measurements demonstrate a very good stability and short-term with long-term performance also under dynamic conditions.
Soccer simulation league is one of the founding leagues of RoboCup. In this paper we discuss the past, present and planned future achievements and changes. Also we summarize the connections and inter-league achievements of this league and provide an overview of the community contributions that made this league successful.
On the possibility to use leaky feeders for positioning in chirp spread spectrum technologies
(2014)
Real Time Localization Systems using electromagnetic waves have significantly evolved during the last years. They also might be used in industrial and in mining environments. Here, topologies might include tunnels, where it might be difficult to ensure the field coverage. Leaky feeder cables are a common solution in case of normal radio communication. In this paper, we study the possibilities to use leaky feeders also for Time-of-Flight based real time localization in such linear topologies, like tunnels, but possibly also for 2D-localization. Theoretical analysis is verified with real-life measurements, which were performed using Chirp Spread Spectrum Technologies.
In the brain-cell microenvironment, diffusion plays an important role: apart from delivering glucose and oxygen from the vascular system to brain cells, it also moves informational substances between cells. The brain is an extremely complex structure of interwoven, intercommunicating cells, but recent theoretical and experimental works showed that the classical laws of diffusion, cast in the framework of porous media theory, can deliver an accurate quantitative description of the way molecules are transported through this tissue. The mathematical modeling and the numerical simulations are successfully applied in the investigation of diffusion processes in tissues, replacing the costly laboratory investigations. Nevertheless, modeling must rely on highly accurate information regarding the main parameters (tortuosity, volume fraction) which characterize the tissue, obtained by structural and functional imaging. The usual techniques to measure the diffusion mechanism in brain tissue are the radiotracer method, the real time iontophoretic method and integrative optical imaging using fluorescence microscopy. A promising technique for obtaining the values for characteristic parameters of the transport equation is the direct optical investigation using optical fibers. The analysis of these parameters also reveals how the local geometry of the brain changes with time or under pathological conditions. This paper presents a set of computations concerning the mass transport inside the brain tissue, for different types of cells. By measuring the time evolution of the concentration profile of an injected substance and using suitable fitting procedures, the main parameters characterizing the tissue can be determined. This type of analysis could be an important tool in understanding the functional mechanisms of effective drug delivery in complex structures such as the brain tissue. It also offers possibilities to realize optical imaging methods for in vitro and in vivo measurements using optical fibers. The model also may help in radiotracer biomarker models for the understanding of the mechanism of action of new chemical entities.
Cardiac resynchronization therapy (CRT) with biventricular pacing is an established therapy for heart failure (HF) patients (P) with ventricular desynchronization and reduced left ventricular (LV) ejection fraction. The aim of this study was to evaluate electrical right atrial (RA), left atrial (LA), right ventricular (RV) and LV conduction delay with novel telemetric signal averaging electrocardiography (SAECG) in implantable cardioverter defibrillator (ICD) P to better select P for CRT and to improve hemodynamics in cardiac pacing.
Methods: ICD-P (n=8, age 70.8 ± 9.0 years; 2 females, 6 males) with VVI-ICD (n=4), DDD-ICD (n=3) and CRT-ICD (n=1) (Medtronic, Inc., Minneapolis, MN, USA) were analysed with telemetric ECG recording by Medronic programmer 2090, ECG cable 2090AB, PCSU1000 oscilloscope with Pc-Lab2000 software (Velleman®) and novel National Intruments LabView SAECG software.
Results: Electrical RA conduction delay (RACD) was measured between onset and offset of RA deflection in the RAECG. Interatrial conduction delay (IACD) was measured between onset of RA deflection and onset of far-field LA deflection in the RAECG. Interventricular conduction delay (IVCD) was measured between onset of RV deflection in the RVECG and onset of LV deflection in the LVECG. Telemetric SAECG recording was possible in all ICD-P with a mean of 11.7 ± 4.4 SAECG heart beats, 97.6 ± 33.7 ms QRS duration, 81.5 ± 44.6 ms RACD, 62.8 ± 28.4 ms RV conduction delay, 143.7 ± 71.4 ms right cardiac AV delay, 41.5 ms LA conduction delay, 101.6 ms LV conduction delay, 176.8 ms left cardiac AV delay, 53.6 ms IACD and 93 ms IVCD.
Conclusions: Determination of RA, LA, RV and LV conduction delay, IACD, IVCD, right and left cardiac AV delay by telemetric SAECG recording using LabView SAECG technique may be useful parameters of atrial and ventricular desynchronization to improve P selection for CRT and hemodynamics in cardiac pacing.
About 20% of those heart failure patients receiving cardiac resynchronization therapy (CRT) are in atrial fibrillation (AF). Current guidelines apply for patients in sinus rhythm only. Recent studies have shown again, that successful resynchronization is closely linked to a pre-existent ventricular desynchronization. In those studies, the interventricular conduction delay (IVCD) was determined prior to device implantation by ultrasound in patients with sinus rhythm (SR)only. In patients with AF this method ́s use is limited.
To implement left-heart electrogram (LHE) into standard programmers and to simplify IVCD measurement in heart failure patients with AF, LHE was recorded in 11 AF patients with heart failure by Biotronik ICS3000 programmer via a15Hz Butterworth high-pass filter. Therefore, TOslim esophageal electrode (Dr. Osypka GmbH, Rheinfelden, Germany) was perorally applied and fixed in position of maximal left ventricular defection. IVCD was measured between onset of QRS in surface ECG and left ventricular defection (LV) in LHE. In addition, intra-left ventricular conduction delay (ILVCD) was measured as duration of LV in LHE.
In all of the 11 AF patients, desynchronization was quantifiable by LHE. Mean QRS of 162 ± 27ms (120-206ms) was linked with IVCD of 62ms ± 27ms (37-98ms) and ILVCD of 110 ± 20ms (80-144ms), at mean. Correlation between IVCD and QRS was 0.39 (n. s.) with IVCD/QRS ratio of 0.38 ± 0.11 (0.22-0.81).
A 15Hz high-pass filtered LHE feature of the Biotronik ICS3000 programmer is feasible to quantify ventricular dyssynchrony in heart failure patients with AF in order to clearly indicate implantation of CRT systems. As relations between QRS duration, IVCD and ILVCD considerably differ interindividually, the predictive values of IVCD, ILVCD and IVCD/QRS ratio for individual CRT response or non-response shall be identified in follow-up studies.
A theoretical description is given for the propagation of surface acoustic wave pulses in anisotropic elastic media subject to the influence of nonlinearity. On the basis of nonlinear elasticity theory, an evolution equation is presented for the surface slope or the longitudinal surface velocity associated with an acoustic pulse. It contains a non-local nonlinearity, characterized by a kernel that strongly varies from one propagation geometry to another due to the anisotropy of the substrate. It governs pulse shape evolution in homogeneous halfspaces and the shapes of solitary surface pulses that exist in coated substrates. The theory describing nonlinear Rayleigh-type surface acoustic waves is extended in a straightforward way to surface waves that are localized at a one-dimensional acoustic waveguide like elastic wedges.
In this paper we present the implementation of a model-predictive controller (MPC) for real-time control of a cable-robot-based motion simulator. The controller computes control inputs such that a desired acceleration and angular velocity at a defined point in simulator’s cabin are tracked while satisfying constraints imposed by working space and allowed cable forces of the robot. In order to fully use the simulator capabilities, we propose an approach that includes the motion platform actuation in the MPC model. The tracking performance and computation time of the algorithm are investigated in computer simulations. Furthermore, for motion simulation scenarios where the reference trajectories are not known beforehand, we derive an estimate on how much motion simulation fidelity can maximally be improved by any reference prediction scheme compared to the case when no prediction scheme is applied.
This work describes a camera-based method for the calibration of optical See-Through Glasses (STGs). A new calibration technique is introduced for calibrating every single display pixel of the STGs in order to overcome the disadvantages of a parametric model. A non-parametric model compared to the parametric one has the advantage that it can also map arbitrary distortions. The new generation of STGs using waveguide-based displays [5] will have higher arbitrary distortions due to the characteristics of their optics. First tests show better accuracies than in previous works. By using cameras which are placed behind the displays of the STGs, no error prone user interaction is necessary. It is shown that a high accuracy tracking device is not necessary for a good calibration. A camera mounted rigidly on the STGs is used to find the relations between the system components. Furthermore, this work elaborates on the necessity of a second subsequent calibration step which adapts the STGs to a specific user. First tests prove the theory that this subsequent step is necessary.
This work describes a non-parametric camera-based method for the calibration of Optical See-Through Glasses (OSTG). Existing works model the optical system through perspective projection and parametric functions. In the border areas of the displays such models are often inadequate. Moreover, rigid calibration patterns, that produce only a small amount of non-equidistant point correspondences, are used. In order to overcome these disadvantages every single display pixel is calibrated individually. The error prone user interaction is avoided by using cameras placed behind the displays of the OSTG. The displays show a shifting pattern that is used to calculate the pixels' locations. A camera mounted rigidly on the OSTG is used to find the relations between the system components. The obtained results show better accuracies than in previous works and prove that a second calibration step for user adaptation is necessary for high accuracy applications.
In this paper, we establish a simple model for the exchange of messages in a vehicular network and we consider fundamental limits on the achievable data rate. For a vehicular network, the exchange of data with other nearby vehicles is particularly important for traffic safety, e.g. for collision avoidance, but also for cooperative applications like platooning. These use cases are currently addressed by standards building on IEEE 802.11p, namely ITS-G5 and DSRC (dedicated short range communication), which encounter saturation problems at high vehicle densities. For this reason, we take a step back and ask for the fundamental limits for the common data rate in a vehicular network. After defining a simple single-lane model and the corresponding capacity limits for some basic multiple- access schemes, we present results for a more realistic setting. For both scenarios, non-orthogonal multiple-access (NOMA) yields the best results.
In this paper, we present a frame synchronization method which consists of the non-orthogonal superposition of a synchronization sequence and the data. We derive the optimum detection criterion and compare it to the classical sequential concatenation of synchronization and data sequences. Computer simulations confirm the benefits of the non-orthogonal allocation for the case of short frames, which makes this technique particularly suited for the increasingly important regime of low latency and ultra- reliable communication.
Non-fluoroscopic Imaging with MRT/CT Image Integration - Catheter Positioning with Double Precision
(2014)
Introduction: When antiarrhythmic drug therapy has failed, different approaches of pulmonary vein isolation are considered a reasonable option in the treatment of atrial fibrillation. It will be performed predominantly by radiofrequency catheter ablation. As the individual anatomy of left atrium and the pulmonary veins differs considerably, accurate visualization of these structures is essential during catheter positioning. Using non-fluoroscopic electroanatomic mapping system with image integration, electroanatomic mapping can be combined with highly detailed anatomical MRT or CT information on complex left atrial structures. This may facilitate catheter navigation during ablation for atrial fibrillation.
Methods: The CARTO XP electroanatomic system was used in a project during biomedical engineering study to practice image integration of anonymized real patients that underwent pulmonary vein isolation by CARTO XP and a MRT/CT procedure. Using the image integration software, MRT or CT images were imported into the CARTO XP system. The next process was segmentation of the acquired images. It involves dividing the images into different regions in order to select the structures of interest. In clinical routine, this segmentation has to be performed before catheter ablation. Then, the segmented images were aligned with the reconstructed electroanatomic maps. This consists of several steps, including selection of the left atrium, scaling of the reconstructed geometry, fusion of the structures using landmarks, and optimization of the integration by adjusting the reconstructed geometry of the left atrium.
Results: In the 3 months lasting period of the project, image integration was trained in 13 patients undergoing catheter ablation for atrial fibrillation. Within this period, time consumption for the process decreased from about 90 minutes at the beginning to about 35 minutes at the end for one patient.
Conclusion: Image integration into non-fluoroscopic electroanatomic map is a sophisticated tool in cardiac radiofrequency catheter ablation. Intensive training is necessary to control the procedure.
Die Verwendung von Kameras als Messmittel für medizinische Anwendungen setzt deren präzise Kalibrierung voraus. Gängige Verfahren modellieren die Abbildungseigenschaften einer Kamera mittels perspektivischer Projektion und parametrisierter Funktionen zur Beschreibung von Linsenverzerrung. In den Randbereichen des Kamerabildes sind diese Modelle oft unzureichend. Außerdem bedingt die Verwendung starrer Kalibriermuster eine in der Regel kleine Anzahl an nicht gleichmäßig verteilten Punktkorrespondenzen zur Bestimmung der Modellparameter. In der vorliegenden Arbeit wird ein vollkommen neues und nicht auf Modellen basierendes Kalibrierverfahren vorgestellt, bei dem jedes Kamerapixel unabhängig von jedem anderen kalibriert wird.
Hintergrund: Das elektrische interventrikuläre Delay (IVD) und die Lage der linksventrikulären (LV) Elektrode zum Ort der spätesten LV Erregung sind bei Patienten (P) mit Herzinsuffizienz (HF), reduzierter LV Funktion und breiter QRS Dauer (QRSD) von Bedeutung für den Erfolg der kardialen Resynchronisationstherapie (CRT). Die LV Elektrokardiographie ermöglicht eine Abschätzung des elektrischen IVD. Ziel der Studie besteht in der nicht-invasiven Evaluierung des elektrischen IVD bei Patienten (P) mit Vorhofflimmern (AFib) mit und ohne CRT mit biventrikulärer (BV) Stimulation.
Methoden: Bei 49 HF P mit AFib (Alter 63,9 ± 10,8 Jahre; 43 Männer und 6 Frauen) mit New York Heart Association (NYHA) Klasse 2,9 ± 0,4, LV Ejektionsfraktion 26,03 ± 7,99 % und QRS-Dauer (QRSD) 143,69 ± 35,62 ms wurde das elektrische IVD als Intervall zwischen Beginn des QRS-Komplexes im Oberflächen EKG und Beginn des LV Signals im transösophagealen LV EKG bei 31 HF P mit AFib und bei 18 HF P mit AFib und CRT präoperativ bestimmt. Das fokussierte bipolare LV EKG wurde mittels Osypka TO Sonde mit halbkugelförmigen Elektroden in Höhe des maximalen LV Signals registriert.
Ergebnisse: Bei 31 HF P mit AFib betrugen QRSD 135,48 ± 38,78 ms, IVD 49,55 ± 26,38 ms, QRSD-IVD-Verhältnis 3,12 ± 1,11 und das IVD korrelierte mit der QRSD (r=0,75, P<0,001) und dem QRSD-IVD-Verhältnis (r=-0,67, P<0,001) (Fig.). Bei 18 HF P mit AFib und CRT Defibrillator betrugen QRSD 157,83 ± 24,38 ms, IVD 61,94 ± 26,88 ms, QRSD-IVD-Verhältnis 3,12 ± 1,89 und das IVD korrelierte mit der QRSD (r=0,47, P=0,049) und dem QRSD-IVD-Verhältnis (r=-0,73, P<0,001). Bei 72,2 % CRT Responder (R) (n=13) betrugen QRSD 158,15 ± 22,4 ms, IVD 64,23 ± 24,62 ms, QRSD-IVD-Verhältnis 2,82 ± 1,32 und das IVD korrelierte mit der QRSD (r=0,57, P=0,043) und dem QRSD-IVD-Verhältnis (r=-0,76, P=0,0024). Bei 27,8 % CRT Non-Responder (NR) (n=5) betrugen QRSD 157 ± 31,94 ms, IVD 56 ± 34,52 ms, QRSD-IVD-Verhältnis 3,88 ± 2,98 und das IVD korrelierte nicht mit der QRSD (r=0,33, P=0,591) und dem QRSD-IVD-Verhältnis (r=-0,732, P=0,159). Die CRT R verbesserten sich in der NYHA Klasse von 3 ± 0,2 auf 2,2 ± 0,3 (P<0,001) während 15,3 ± 13,1 Monaten BV Stimulation. Bei 15 CRT NR kam es zu keiner Verbesserung der NYHA Klasse von 3 auf 3,3 ± 0,97 (P=0,529) während 18,8 ± 20,7 Monaten BV Stimulation.
Schlussfolgerungen: Das transösophageale LV EKG ermöglicht bei HF-P mit AFib die nichtinvasive Messung des elektrischen IVD präoperativ vor CRT. IVD und QRSD-IVD-Verhältnis sind möglicherweise einfach anwendbare Parameter zur Vorhersage von CRT R und CRT NR bei P mit AFib.
NEXCODE is a project promoted by the European Space Agency aimed at research design development and demonstration of a receiver chain for telecomm and links in space missions including the presence of new short low-density parity-check codes for error correction. These codes have excellent performance from the error rate viewpoint but also put new challenges as regards synchronization issues and implementation. In this paper after a short review of the results obtained through numerical simulations we present an overview of the breadboard designed for practical testing and the test-plan proposed for the verification of the breadboard and the validation of the new codes and novel synchronization techniques under relevant operation conditions.
New frontiers of supraventricular tachycardia and atrial flutter evaluation and catheter ablation
(2012)
Radiofrequency catheter ablation (RFCA) has revolutionized treatment for tachyarrhythmias and has become first-line therapy for some tachycardias. Although developed in the 1980s and widely applied in the 1990s, the technique is still in development. Transesophageal atrial pacing (TAP) can used for initiation and termination of supraventricular tachycardia (SVT).
Methods: The paroxysmal SVT include a wide spectrum of disorders including, in descending order of frequency, atrial flutter, atrioventricular (AV) nodal reentry, Wolff-Parkinson-White syndrome, and atrial tachycardia. While not life-threatening in most cases, they may cause important symptoms, such as palpitations, chest discomfort, breathlessness, anxiety, and syncope, which significantly impair quality of life. Medical therapy has variable efficacy, and most patients are not rendered free of symptoms. Research over the past several decades has revealed fundamental mechanisms involved in the initiation and maintenance of all of these arrhythmias. Knowledge of mechanisms has in turn led to highly effective surgical and catheter-based treatments. The supraventricular arrhythmias and their treatment are described in this report. SVT initiation was analysed with programmed TAP in 49 patients with palpitations (age 47 ± 17 years, 24 females, 25 males).
Results: In comparison to antiarrhythmic drug therapy the radiofrequency catheter ablation in patients suffering from atrial flutter, atrioventricular nodal reentry, atrioventricular reentry and atrial tachycardia is the better choice in most cases. TAP SVT initiation was possible in 23 patients before RFCA. Atrial cycle length of SVT was 320 ± 59 ms. We initiated AV nodal reentrant tachycardia (AVNRT, n=15), atrial tachycardia (AT, n=6) and AV reentrant tachycardia with Kent pathway conduction (AVRT, n=2) before RFCA.
Conclusions: Radiofrequency catheter ablation is a successful and safe method to cure most patients with paroxysmal supraventricular tachycardias. TAP allowed initiation and termination of SVT especially in outpatients.
Ein neuer Ansatz wurde für mobile Roboter zur gleichzeitigen 3D (Drei-Dimensionaler) Kartierung und Lokalisierung vorgestellt. Die Grundlage bilden attributierte Flächenmodelle, die z.B. von segmentierten Laserscanner-Tiefenbildern stammen. Zur Optimierung der Gesamtähnlichkeit zwischen Flächenmodellen unter Zeitbedingungen werden mehrere Verfahren (Beschränkte Baumsuche, Iterative Verfeinerung, Evolutionäralgorithmus) kombiniert. Es wird speziell anhand der Ähnlichkeitsmaße gezeigt, wie das Wissen über die Lage stufenweise generiert und verwendet wird. Erste Messungen an realen segmentierten Tiefenbildfolgen zeigen, dass das Verfahren unbekannte übelappung, Verdeckung und Segmentierungsfehler toleriert sowie Echtzeitpotenzial besitzt.
MPC-Workshop Juni 2002
(2002)
MPC-Workshop Juli 2018
(2018)
MPC-Workshop Juli 2015
(2015)
MPC-Workshop Juli 2014
(2014)
MPC-Workshop Juli 2013
(2013)
MPC-Workshop Juli 2012
(2012)
MPC-Workshop Juli 2011
(2011)
MPC-Workshop Juli 2007
(2007)
MPC-Workshop Juli 2006
(2006)
MPC-Workshop Juli 2005
(2005)
MPC-Workshop Juli 2004
(2004)
MPC-Workshop Juli 2003
(2003)
MPC-Workshop Juli 2001
(2001)
MPC-Workshop Januar 2003
(2003)
MPC-Workshop Januar 2002
(2002)
MPC-Workshop Februar 2016
(2016)