Refine
Year of publication
- 2014 (81) (remove)
Document Type
- Conference Proceeding (81) (remove)
Conference Type
- Konferenzartikel (59)
- Konferenz-Abstract (11)
- Konferenzband (6)
- Konferenz-Poster (3)
- Sonstiges (2)
Keywords
- E-Learning (3)
- Produktentwicklung (3)
- Produktion (3)
- RoboCup (3)
- Ausbildung (2)
- Cloud Computing (2)
- Design (2)
- Herzkrankheit (2)
- Hochtemperatur (2)
- Katheter (2)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (50)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (15)
- Fakultät Wirtschaft (W) (10)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (9)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (6)
- INES - Institut für nachhaltige Energiesysteme (2)
- POIM - Peter Osypka Institute of Medical Engineering (2)
- Zentrale Einrichtungen (2)
Open Access
- Open Access (35)
- Closed (24)
- Closed Access (21)
- Bronze (9)
This paper describes the new Sweaty humanoid adult size robot trying to qualify for the RoboCup 2014 adult size humanoid competition. The robot is built from scratch to eventually allow it to run. One characteristic is that to prevent the motors from overheating, water evaporation is used for cooling. The robot is literally sweating which has given it its name. Another characteristic is, that the motors are not directly connected to the frame but by means of beams. This allows a variable transmission ratio depending on the angle.
A new RFID/NFC (ISO 15693 standard) based inductively powered passive SoC (System on chip) for biomedical applications is presented here. The proposed SOC consists of an integrated 32 bit microcontroller, RFID/NFC frontend, sensor interface circuit, analog to digital converter and some peripherals such as timer, SPI interface and memory devices. An energy harvesting unit supplies the power required for the entire system for complete passive operation. The complete chip is realized on CMOS 0.18 μm technology with a chip area of 1.5 mm × 3.0 mm.
Although short range wireless communication explicitly targets local and very regional applications, range continues to be an extremely important issue. The range directly depends on the so called link budget, which can be increased by the choice of modulation and coding schemes. Especially, the recent transceiver generation comes with extensive and flexible support for Software Defined Radio (SDR). The SX127x family from Semtech Corp. is a member of this device class and promises significant benefits for range, robust performance, and battery lifetime compared to competing technologies. This contribution gives a short overview into the technologies to support Long Range (LoRa ™), describes the outdoor setup at the Laboratory Embedded Systems and Communication Electronics of Offenburg University of Applied Sciences, shows detailed measurement results and discusses the strengths and weaknesses of this technology.
Data is ever increasing in the computing world. Due to advancement of cloud technology the dynamics of volumes of data and its capacity has increased within a short period of time and will keep increasing further. Providing transparency, privacy, and security to the cloud users is becoming more and more challenging along with the volume of data and use of cloud services. We propose a new approach to address the above mentioned challenge by recording the user events in the cloud ecosystem into log files and applying MAR principle namely 1) Monitoring 2) Analyzing and 3) Reporting.
E-Tutoren-Ausbildung: Lernerfahrungen reflektieren – Lehrhandlungskompetenzen dialogisch aufbauen
(2014)
The improvements in the hardware and software of communication devices have allowed running Virtual Reality (VR) and Augmented Reality (AR) applications on those. Nowadays, it is possible to overlay synthetic information on real images, or even to play 3D on-line games on smart phones or some other mobile devices. Hence the use of 3D data for business and specially for education purposes is ubiquitous. Due to always available at hand and always ready to use properties of mobile phones, those are considered as most potential communication devices. The total numbers of mobile phone users are increasing all over the world every day and that makes mobile phones the most suitable device to reach a huge number of end clients either for education or for business purposes. There are different standards, protocols and specifications to establish the communication among different communication devices but there is no initiative taken so far to make it sure that the send data through this communication process will be understood and used by the destination device. Since all the devices are not able to deal with all kind of 3D data formats and it is also not realistic to have different version of the same data to make it compatible with the destination device, it is necessary to have a prevalent solution. The proposed architecture in this paper describes a device and purpose independent 3D data visibility any time anywhere to the right person in suitable format. There is no solution without limitation. The architecture is implemented in a prototype to make an experimental validation of the architecture which also shows the difference between theory and practice.
Logging information is more precious as it contains the execution of a system; it is produced by millions of events from simple application logins to random system errors. Most of the security related problems in the cloud ecosystem like intruder attacks, data loss, and denial of service, etc. could be avoided if Cloud Service Provider (CSP) or Cloud User (CU) analyses the logging information. In this paper we introduced few challenges, which are place of monitoring, security, and ownership of the logging information between CSP and CU.
Also we proposed a logging architecture to analyze the behaviour of the cloud ecosystem, to avoid data breaches and other security related issues at the CSP space. So that we believe our proposed architecture can provide maximum trust between CU and CSP.
MPC-Workshop Juli 2014
(2014)
MPC-Workshop Februar 2014
(2014)
In this work a set of nonlinear coupled COM equations at interacting frequencies is derived on the basis of nonlinear electro-elasticity. The formalism is presented with the aim of describing intermodulation distortion of third-order (IMD3) and triple beat. The resulting COM equations are translated to the P-matrix formalism, where care is taken to obtain the correct frequency dependence. The scheme depends on two frequency-independent constants for an effective third-order nonlinearity. One of these two constants is negligibly small in the systems considered here. The P-matrix approach is applied to single filters and duplexers on LiTaO 3 (YXl)/42° operating in different frequency ranges. Both IMD3 and triple beat show good agreement with measurement.
Photonics meet digital art
(2014)
The paper focuses on the work of an interdisciplinary project between photonics and digital art. The result is a poster collection dedicated to the International Year of Light 2015. In addition, an internet platform was created that presents the project. It can be accessed at http://www.magic-of-light.org/iyl2015/index.htm. From the idea to the final realization, milestones with tasks and steps will be presented in the paper. As an interdisciplinary project, students from technological degree programs were involved as well as art program students. The 2015 Anniversaries: Alhazen (1015), De Caus (1615), Fresnel (1815), Maxwell (1865), Einstein (1905), Penzias Wilson, Kao (1965) and their milestone contributions in optics and photonics will be highlighted.
Since direct current high energy shock fulguration was initially performed in the mid 1980s, ablation of cardiac arrhythmias has come to widespread use. Today the most frequently used energy source for catheter ablation is radio frequency (RF). It was the German engineer Peter Osypka who made available the HAT 100 as the first simple commercial RF ablator.
Nevertheless, in the first years of ablation, physicians were effectively working in the dark. Until today with an increasing understanding of arrhythmia mechanisms, both at the atrial and ventricular levels, this curative technology has made tremendous progress. Now, due to crucial improvement of RF ablation generators, temperature and contact force sensor catheters in combination with non-flouroscopic electroanatomical mapping technologies, computerized temperature and impedance controlled radiofrequency catheter ablation can be used to cure all types of arrhythmias including atrial and ventricular fibrillation. For the latter, cooled ablation by saline solution irrigated catheters has been developed to a widely used standard method. This procedure resulting in pulmonary vein isolation requires transseptal puncture and is technically demanding. Nevertheless, it has shown to be more effective than antiarrhythmic drug therapy.
While earliest RF ablations were performed with non-steerable catheters, today are used steerable sensor catheters without or with external and internal cooling and tips of 4mm or 8mm length. Further innovations like integration of mapping and cardiac imaging give exact information of the number of pulmonary veins and branching patterns and help to correlate electrical signals with anatomical structures.
The magnetic navigation significantly improved the success rates and safety of catheter ablation. Thus, in most cases RF catheter ablation has developed in the treatment of supraventricular arrhythmias from an alternative approach to drug therapy into the first therapeutic choice providing low complication rates.
In future, robotic navigation will further simplify procedures and reduce radiation exposure of this curative approach.
Introduction: Despite lots of developments in the last years, radiofrequency ablation of rhythm diseases is a safe but still complex procedure that requires special experience and expertise of the physicians and biomedical engineers. Thus, there is a need of special trainings to become familiar with the different equipment and to explain several effects that can be observed during clinical routine.
Methods: The Offenburg University of Applied Sciences offers a biomedical engineering study path specialized in the fields of cardiology, electrophysiology and cardiac electronic implants. It`s Peter Osypka Institute for Pacing and Ablation provides teaching following the slogan “Learning by watching, touching and adjusting”. It conducts lots of trainings for students as well as young physicians interested in electrophysiology and radiofrequency ablation.
Results: In-vitro trainings will be provided using the Osypka HAT 200 and HAT300s, Stockert EPshuttle and SmartAblate system as well as the Boston EPT-1000XP and Maestro 3000 and the Radionics RFG-3E cardiac radio frequency ablation generators. All of them require different handling as well as special accessories like catheter connection cables or boxes and back plates. The participants will be trained in the setup of temperature, power and cut-off impedance dependent on different ablation catheters. Furthermore troubleshooting in hard- and software is part of the program. Performing procedures in pork or animal protein and using physiological saline solution to simulate the blood flow, they can study the influence of contact force and impedance on lesion geometry etc. and to avoid adverse effects like “plops”. Lots of catheter types are available: 4mm tip, 8mm standard and gold tip, open and closed irrigated tip ablation catheters of different companies. The experiments will be completed by measuring the lesion size dependent on the used catheter type and ablation settings.
Conclusion: In-vitro training in radiofrequency ablation is a challenge for biomedical engineering students and young physicians.
HiSiMo cast irons are frequently used as material for high temperature components in engines as e.g. exhaust manifolds and turbo chargers. These components must withstand severe cyclic mechanical and thermal loads throughout their life cycle. The combination of thermal transients with mechanical load cycles results in a complex evolution of damage, leading to thermomechanical fatigue (TMF) of the material and, after a certain number of loading cycles, to failure of the component. In Part I of the paper, a fracture mechanics model for TMF life prediction was developed based on results of uniaxial tests. In this paper (Part II), the model is formulated for three-dimensional stress states, so that it can be applied in a post-processing step of a finite-element analysis. To obtain reliable stresses and (time dependent plastic) strains in the finite-element calculation, a time and temperature dependent plasticity model is applied which takes non-linear kinematic hardening into account. The material properties of the model are identified from the results of the uniaxial test. The plasticity model and the TMF life model are applied to assess the lifetime of an exhaust manifold.
Die zunehmende Anzahl von Transistoren mit immer kleineren Strukturgrößen führt zu einer zunehmenden Leistungsaufnahme in modernen Prozessoren. Das gilt insbesondere für High-End Prozessoren, die mit einer hohen Taktfrequenz betrieben werden. Die aufgenommene Leistung wird in Wärme umgewandelt, die in einer Temperaturerhöhung der Prozessoren resultiert. Hohe Betriebstemperaturen verursachen u.a. eine verringerte Rechenleistung, eine kürzere Lebensdauer des Prozessors und höhere Leckströme. Aus diesen Gründen wird aktives, dynamisches thermisches Management immer wichtiger. Dieser Beitrag stellt eine Erweiterung zu dem Standard- Linux-Scheduler in der Kernel-Version 3.0 für eingebettete Systeme vor: einen PID-Regler, der unter Angabe einer Solltemperatur eine dynamische Frequenz- und Spannungsskalierung durchführt. Die Experimente auf dem Freescale LMX6 Quadcore-Prozessor zeigen, dass der PID-Regler die Betriebstemperatur des Prozessors an die Solltemperatur regeln kann. Er ist die Grundlage für eine in Zukunft zu entwickelnde prädiktive Regelung.
Transcatheter aortiv valve implantation is a new safe strategy treatment for patients with symptomatic severe aortic stenosis and high operative risk. The aim of the study was to compare the pre-and post- muiscatheter aortiv valve implantation procedures to determine the atrioventricuktr conduction time as a potential predictor of permanent pacemaker therapy requirement after transcatheter aortiv valve implantation. The transcatheter aortiv valve implantation patients were divided into groups without pacemaker and with dual or single chamber pacemEtker with diffent atrioventrieular conduction time disturbance before and after transcatheter aortiv valve implantation. In heart failure, patients without permanent pacemaker therapy after transcatheter aortiv valve implantation, atrioventricular conduction time was prolonged after transcatheter aortiv valve implantation. In patients with permanent dual chamber pacemaker therapy after transcatheter aortiv valve implantation, atrioventricular conduction time was normalised with dual chaniber atrioventrieuku pacing mode. Atrioventricular conduction time may be a useful parameter to evaluate the risk of post-procedural atrioventricular conduction block and permanent pacemaker therapy in transcatheter north, valve implantation patients.
Höchste Korrosionsschutzanforderungen sind für bestimmte technische Produkte insbesondere im Offshore Anwendungsbereich, nach ISO 20340, zwingend zu erfüllen, um deren Funktion und Betriebssicherheit dauerhaft gewährleisten zu können. Bis heute werden viele dieser Produkte am Ende ihrer Wertschöpfungskette nass überlackiert, mit einer kompletten Kunststoffhaut, der Korrosionsschutz-Lackschicht, überzogen. Diese Lackierung ist unter anderem deshalb erforderlich, weil es im klassischen Maschinenbau, insbesondere in der Antriebstechnik, viele mechanische Schnittstellen gibt, die vor der endgültigen Produktmontage quasi metallisch blank bleiben müssen, um den erforderlichen und definierten geometrischen Oberflächenzustand nach Form und Lage als Pass- und Fügefläche zu gewährleisten. Eine dieser mechanischen Schnittstellen sind Schraubenverbindungen. Mit dem derzeit gültigen Regelwerk ist die Berechnung einer Schraubenverbindung mit Lackschichten in den Trennfugen oder auf der Kopf- und Mutternauflagefläche nicht möglich, da lackierte Bauteile in der derzeit geltenden VDI-Richtlinie 2230 nicht berücksichtigt sind. Nach einem Praxisbericht anhand von Stellantrieben für Industriearmaturen über deren Umstellung von Nasslackierung des Gesamtproduktes auf Pulverbeschichtung von Einzelteilen wird die experimentelle Validierung der Betriebs- und Funktionssicherheit von Schraubenverbindungen mit lackierten Bauteilen vorgestellt. Daraus resultierend wurde im März 2014 an der Hochschule Offenburg ein Forschungsprojekt gestartet, dessen Ziel es ist für die oben genannte Problemstellung einen systematischen Lösungsansatz zu erarbeiten. Künftig soll es Entwicklungsingenieuren und Konstrukteuren bereits in der Phase von Entwicklung und Konstruktion möglich sein Schraubenverbindungen mit lackierten Bauteilen zuverlässig zu berechnen und auszulegen oder diese in der Prototypenphase zuverlässig zu testen. Die letzten beiden Abschnitte geben den Lösungsansatz und den aktuellen Stand der Forschung wider.
Non-fluoroscopic Imaging with MRT/CT Image Integration - Catheter Positioning with Double Precision
(2014)
Introduction: When antiarrhythmic drug therapy has failed, different approaches of pulmonary vein isolation are considered a reasonable option in the treatment of atrial fibrillation. It will be performed predominantly by radiofrequency catheter ablation. As the individual anatomy of left atrium and the pulmonary veins differs considerably, accurate visualization of these structures is essential during catheter positioning. Using non-fluoroscopic electroanatomic mapping system with image integration, electroanatomic mapping can be combined with highly detailed anatomical MRT or CT information on complex left atrial structures. This may facilitate catheter navigation during ablation for atrial fibrillation.
Methods: The CARTO XP electroanatomic system was used in a project during biomedical engineering study to practice image integration of anonymized real patients that underwent pulmonary vein isolation by CARTO XP and a MRT/CT procedure. Using the image integration software, MRT or CT images were imported into the CARTO XP system. The next process was segmentation of the acquired images. It involves dividing the images into different regions in order to select the structures of interest. In clinical routine, this segmentation has to be performed before catheter ablation. Then, the segmented images were aligned with the reconstructed electroanatomic maps. This consists of several steps, including selection of the left atrium, scaling of the reconstructed geometry, fusion of the structures using landmarks, and optimization of the integration by adjusting the reconstructed geometry of the left atrium.
Results: In the 3 months lasting period of the project, image integration was trained in 13 patients undergoing catheter ablation for atrial fibrillation. Within this period, time consumption for the process decreased from about 90 minutes at the beginning to about 35 minutes at the end for one patient.
Conclusion: Image integration into non-fluoroscopic electroanatomic map is a sophisticated tool in cardiac radiofrequency catheter ablation. Intensive training is necessary to control the procedure.