Refine
Year of publication
- 2017 (92) (remove)
Document Type
- Conference Proceeding (92) (remove)
Conference Type
- Konferenzartikel (62)
- Konferenz-Abstract (22)
- Konferenz-Poster (3)
- Sonstiges (3)
- Konferenzband (2)
Keywords
- CST (4)
- HF-Ablation (4)
- CRT (3)
- RoboCup (3)
- Gamification (2)
- IVD (2)
- Affective Computing (1)
- Aktivierung (1)
- Arbeitswissenschaft (1)
- Computer Games (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (40)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (27)
- Fakultät Wirtschaft (W) (13)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (12)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (11)
- ACI - Affective and Cognitive Institute (4)
- WLRI - Work-Life Robotics Institute (4)
- Zentrale Einrichtungen (2)
- INES - Institut für nachhaltige Energiesysteme (1)
Open Access
- Open Access (47)
- Closed Access (40)
- Bronze (6)
- Closed (4)
- Grün (1)
Simulation-based degradation assessment of lithium-ion batteries in a hybrid electric vehicle
(2017)
The insufficient lifetime of lithium-ion batteries is one of the major cost driver for mobile applications. The battery pack in vehicles is one of the most expensive single components that practically must be excluded from premature replacement (i.e., before the life span of the other components end). Battery degradation is a complex physicochemical process that strongly depends on operating condition and environment. We present a simulation-based analysis of lithium-ion battery degradation during operation with a standard PHEV test cycle. We use detailed multiphysics (extended Newman-type) cell models that allow the assessment of local electrochemical potential, species and temperature distributions as driving forces for degradation, including solid electrolyte interphase (SEI) formation [1]. Fig. 1 shows an exemplary test cycle and the predicted resulting spatially-averaged SEI formation rate. We apply a time-upscaling approach to extrapolate the degradation analysis over long time scales, keeping physical accuracy while allowing end-of-life assessment [2]. Results are presented for lithium-ion battery cells with graphite/LFP chemistry. The behavior of these cells in terms of degradation propensity, performance, state of charge and other internal states is predicted during long-term cycling. State of health (SOH) is quantified as capacity fade and internal resistance increase as function of operation time.
Practical bottlenecks associated with commercialization of Lithium-air cells include capacity limitation and low cycling efficiency. The origin of such losses can be traced to complex electrochemical side reactions and reactant mass transport losses[1]. The efforts to minimize such losses include exploration of various electrolytes with additives[2], and cell component geometry and material design. Given the wide range of options for such materials, it is almost impractical to experimentally setup and characterize all those cells. Consequently, modeling and simulation studies are efficient alternatives to analyze spatially and temporally resolved cell behavior for various combinations of materials[3]. In this study, with the help of a two-dimensional multi physics model, we have focused on the effect of electrode and electrolyte interaction (electrochemistry), choice of electrolyte (species transport), and electrode geometry (electrode design) on the performance of a lithium-air button cell. Figure1a shows the schematics of the 2D axisymmetric computational domain. A comparative analysis of five different electrolytes was performed while focusing on the 2D distribution of local current density and the concentration of electro-chemically active species in the cell, that is, O2and Li+. Using two different cathode configurations, namely, flooded electrode and gas diffusion electrode (GDE)[4] at different cathode thickness, the effect of cell geometry and electrolyte saturation on cell performance was explored. Further, a detailed discussion on electrode volume utilization (cf. Figure1b) is presented via changes in the active volume of cathode that produces 90% of the total current with the cell current density for different combinations of electrolyte saturations and cathode thickness.
Simulation-based degradation assessment of lithium-ion batteries in a hybrid electric vehicle
(2017)
Muli-scale thermos-electrochemical modelling of aging mechanisms in an LFP/graphite lithium-ion cell
(2017)
Passive hybridization of battery cell and photovoltaic cell: modeling and experimental validation
(2017)
A novel approach of a test environment for embedded networking nodes has been conceptualized and implemented. Its basis is the use of virtual nodes in a PC environment, where each node executes the original embedded code. Different nodes run in parallel, connected via so-called virtual channels. The environment allows to modifying the behavior of the virtual channels as well as the overall topology during runtime to virtualize real-life networking scenarios. The presented approach is very efficient and allows a simple description of test cases without the need of a network simulator. Furthermore, it speeds up the process of developing new features as well as it supports the identification of bugs in wireless communication stacks. In combination with powerful test execution systems, it is possible to create a continuous development and integration flow.
Heart rhythm model and simulation of electrophysiological studies and high-frequency ablations
(2017)
Background: The simulation of complex cardiologic structures has the potential to replace clinical studies due to its high efficiency regarding time and costs. Furthermore, the method is more careful for the patients’ health than the conventional ways. The aim of the study was to create an anatomic CAD heart rhythm model (HRM) as accurate as possible, and to show its usefulness for cardiac electrophysiological studies (EPS) and high-frequency (HF) ablations.
Methods: All natural heart components of the new HRM were based on MRI records, which guaranteed electronic functionality. The software CST (Computer Simulation Technology, Darmstadt) was used for the construction, while CST’s material library assured genuine tissue properties. It should be applicable to simulate different heart rhythm diseases as well as various diffusions of electromagnetic fields, caused by electrophysiological conduction, inside the heart tissue.
Results: It was achievable to simulate normal sinus rhythm and fourteen different heart rhythm disturbance with different atrial and ventricular conduction delays. The simulated biological excitation of healthy and sick HRM were plotted by simulated electrodes of four polar right atrial catheter, six polar His bundle catheter, ten polar coronary sinus catheter, four polar ablation catheter and eight polar transesophageal left cardiac catheter (Fig.). Accordingly, six variables were rebuilt and inserted into the anatomic HRM in order to establish heart catheters for ECG monitoring and HF ablation. The HF ablation catheters made it possible to simulate various types of heart rhythm disturbance ablations with different HF ablation catheters and also showed a functional visualisation of tissue heating. The use of tetrahedral meshing HRM made it attainable to store the results faster accompanied by a higher degree of space saving. The smart meshing function reduced unnecessary high resolutions for coarse structures.
Conclusions: The new HRM for EPS simulation may be additional useful for simulation of heart rhythm disturbance, cardiac pacing, HF ablation and for locating and identification of complex fractioned signals within the atrium during atrial fibrillation HF ablation.
Hintergrund: Das elektrische interventrikuläre Delay (IVD) ist bei Patienten (P) mit Herzinsuffizienz (HF), reduzierter linksventrikulärer (LV) Funktion und verbreitertem QRS Komplex von Bedeutung für den Erfolg der kardialen Resynchronisationstherapie (CRT). Die transösophageale LV Elektrokardiographie (EKG) ermöglicht die Bestimmung des elektrischen IVD und linksventrikulären Delays (LVD). Das Ziel der Studie besteht in der Untersuchung des transösophagealen elektrischen IVD, LVD und deren Verhältnis zur QRS Dauer bei rechtsventrikulärer (RV) Stimulation vor Aufrüstung auf eine biventrikuläre (BV) Stimulation.
Methoden: Bei 11 HF P (Alter 69,0 ± 7,9 Jahre; 10 Männer und 1 Frau) mit DDD Schrittmacher (n=10), DDD Defibrillator (n=1) und RV Stimulation, New York Heart Association (NYHA) Klasse 3,0 ± 0,2, LV Ejektionsfraktion 24,5 ± 4,9 % und QRS-Dauer 228,2 ± 44,8 ms wurden das elektrische IVD als Intervall zwischen Beginn des QRS-Komplexes im Oberflächen EKG und Beginn des LV Signals im transösophagealen LV EKG und das elektrische LVD als Intervall zwischen Beginn und Ende des LV Signals im transösophagealen LV EKG präoperativ vor Aufrüstung auf CRT Defibrillator (n=8) und CRT Schrittmacher (n=3) bestimmt. Der Anstieg des arteriellen Pulse Pressure (PP) wurde zwischen RV Stimulation und transösophagealer LV Stimulation mit unterschiedlichem AV-Delay (n=5) vor Aufrüstung von RV auf BV Stimulation getestet.
Ergebnisse: Bei RV Stimulation betrugen IVD 86,54 ± 32,80 ms, LVD 94,45 ± 23,80 ms, QRS-IVD-Verhältnis 2,63 ± 0,81 mit negativer Korrelation zwischen IVD und QRS-IVD-Verhältnis (r=-0,668 P=0,0248) (Fig.) und QRS-LVD-Verhältnis 2,33 ± 0,73. Vorhofsynchrone ventrikuläre Stimulation führte zu 63,6 ± 27,7 mmHg PP bei RV Stimulation und 80,6 ± 38,5 mmHg PP bei LV Stimulation und der PP erhöhte sich bei LV Stimulation mit optimalem AV Delay um 17 ± 11,2 mmHg gegenüber RV Stimulation (P<0,001). Nach Aufrüstung von RV Stimulation auf BV Stimulation verbesserten sich die NYHA Klasse von 3,1 ± 0,2 auf 2,2 ± 0,3 während 30,4 ± 29,6 Monaten CRT.
Schlussfolgerungen: Das transösophageale LV EKG ermöglicht die Bestimmung des elektrischen IVD und LVD bei RV Stimulation zur Evaluierung der interventrikulären und linksventrikulären elektrischen Desynchronisation. IVD, LVD und deren Verhältnis zur QRS Dauer können möglicherweise zur Vorhersage einer CRT Response vor Aufrüstung von RV auf BV Stimulation genutzt werden.
Heart rhythm model and simulation of electrophysiological studies and high-frequency ablations
(2017)
Background: The simulation of complex cardiologic structures has the potential to replace clinical studies due to its high efficiency regarding time and costs. Furthermore, the method is more careful for the patients’ health than the conventional ways. The aim of the study was to create an anatomic CAD heart rhythm model (HRM) as accurate as possible, and to show its usefulness for cardiac electrophysiological studies (EPS) and high-frequency (HF) ablations.
Methods: All natural heart components of the new HRM were based on MRI records, which guaranteed electronic functionality. The software CST (Computer Simulation Technology, Darmstadt) was used for the construction, while CST’s material library assured genuine tissue properties. It should be applicable to simulate different heart rhythm diseases as well as various diffusions of electromagnetic fields, caused by electrophysiological conduction, inside the heart tissue.
Results: It was achievable to simulate normal sinus rhythm and fourteen different heart rhythm disturbance with different atrial and ventricular conduction delays. The simulated biological excitation of healthy and sick HRM were plotted by simulated electrodes of four polar right atrial catheter, six polar His bundle catheter, ten polar coronary sinus catheter, four polar ablation catheter and eight polar transesophageal left cardiac catheter (Fig.). Accordingly, six variables were rebuilt and inserted into the anatomic HRM in order to establish heart catheters for ECG monitoring and HF ablation. The HF ablation catheters made it possible to simulate various types of heart rhythm disturbance ablations with different HF ablation catheters and also showed a functional visualisation of tissue heating. The use of tetrahedral meshing HRM made it attainable to store the results faster accompanied by a higher degree of space saving. The smart meshing function reduced unnecessary high resolutions for coarse structures.
Conclusions: The new HRM for EPS simulation may be additional useful for simulation of heart rhythm disturbance, cardiac pacing, HF ablation and for locating and identification of complex fractioned signals within the atrium during atrial fibrillation HF ablation.
Background: Cardiac resynchronization therapy (CRT) with biventricular (BV) pacing is an established therapy for heart failure (HF) patients (P) with sinus rhythm, reduced left ventricular (LV) ejection fraction (EF) and electrical ventricular desynchronization. The aim of the study was to evaluate electrical interventricular delay (IVD) and left ventricular delay (LVD) in right ventricular (RV) pacemaker pacing before upgrading to CRT BV pacing.
Methods: HF P (n=11, age 69.0 ± 7.9 years, 1 female, 10 males) with DDD pacemaker (n=10), DDD defibrillator (n=1), RV pacing, New York Heart Association (NYHA) class 3.0 ± 0.2 and 24.5 ± 4.9 % LVEF were measured by surface ECG and transesophageal bipolar LV ECG before upgrading to CRT defibrillator (n=8) and CRT pacemaker (n=3). IVD was measured between onset of QRS in the surface ECG and onset of LV signal in the transesophageal ECG. LVD was measured between onset and offset of LV signal in the transesophageal ECG. CRT atrioventricular (AV) and BV pacing delay were optimized by impedance cardiography.
Results: Interventricular and intraventricular desynchronization in RV pacemaker pacing were 228.2 ± 44.8 ms QRS duration, 86.5 ± 32.8ms IVD, 94.4 ± 23.8ms LVD, 2.6 ± 0.8 QRS-IVD-ratio with correlation between IVD and QRS-IVD-ratio (r=-0.668 P=0.0248) and 2.3 ± 0.7 QRS-LVD-ratio. The LVEF-IVD-ratio was 0.3 ± 0.1 with correlation between IVD and LVEF-IVD-ratio (r=-0.8063 P=0.00272) and with correlation between QRS duration and LVEF-IVD-ratio (r=-0.7251 P=0.01157). Optimal sensing and pacing AV delay were 128.3 ± 24.8 ms AV delay after atrial sensing (n=6) and 173.3 ± 40.4 ms AV delay after atrial pacing (n=3). Optimal BV pacing delay was -4.3 ± 11.3 ms between LV and RV pacing (n=7). During 30.4 ± 29.6 month CRT follow-up, the NYHA class improved from 3.1 ± 0.2 to 2.2 ± 0.3.
Conclusions: Transesophageal electrical IVD and LVD in RV pacemaker pacing may be additional useful ventricular desynchronization parameters to improve P selection for upgrading RV pacemaker pacing to CRT BV pacing.
Background: The electrical field (E-field) of the biventricular (BV) stimulation is essential for the success of cardiac resynchronization therapy (CRT) in patients with cardiac insufficiency and widened QRS complex. 3D modeling allows the simulation of CRT and high frequency (HF) ablation.
Purpose: The aim of the study was to model different pacing and ablation electrodes and to integrate them into a heart model for the static and dynamic simulation of BV stimulation and HF ablation in atrial fibrillation (AF).
Methods: The modeling and simulation was carried out using the electromagnetic simulation software. Five multipolar left ventricular (LV) electrodes, one epicardial LV electrode, four bipolar right atrial (RA) electrodes, two right ventricular (RV) electrodes and one HF ablation catheter were modeled. Different models of electrodes were integrated into a heart rhythm model for the electrical field simulation (fig.1). The simulation of an AV node ablation at CRT was performed with RA, RV and LV electrodes and integrated ablation catheter with an 8 mm gold tip.
Results: The RV and LV stimulation were performed simultaneously at amplitude of 3 V at the LV electrode and 1 V at the RV electrode, each with a pulse width of 0.5 ms. The far-field potentials generated by the BV stimulations were perceived by the RA electrode. The far-field potential at the RA electrode tip was 32.86 mV. A far-field potential of 185.97 mV resulted at a distance of 1 mm from the RA electrode tip. AV node ablation was simulated with an applied power of 5 W at 420 kHz at the distal 8 mm ablation electrode. The temperature at the catheter tip was 103.87 ° C after 5 s ablation time, 44.17 ° C from the catheter tip in the myocardium and 37.61 ° C at a distance of 2 mm. After 10 s, the temperature at the three measuring points described above was 107.33 ° C, 50.87 ° C, 40.05 ° C and after 15 seconds 118.42 ° C, 55.75 ° C and 42.13 ° C.
Conclusions: Virtual heart and electrode models as well as the simulations of electrical fields and temperature profiles allow the static and dynamic simulation of atrial synchronous BV stimulation and HF ablation at AF. The 3D simulation of the electrical field and temperature profile may be used to optimize the CRT and AF ablation.
Electrochemical impedance spectroscopy (EIS) is a widely-used diagnostic technique to characterize electrochemical processes. It is based on the dynamic analysis of two electrical observables, that is, current and voltage. Electrochemical cells with gaseous reactants or products (e.g., fuel cells, metal/air cells, electrolyzers) offer an additional observable, that is, the gas pressure. The dynamic coupling of current and/or voltage with gas pressure gives rise to a number of additional impedance definitions, for which we have introduced the term electrochemical pressure impedance spectroscopy (EPIS) [1,2]. EPIS shows a particular sensitivity towards transport processes of gas-phase or dissolved species, in particular, diffusion coefficients and transport pathway lengths. It is as such complementary to standard EIS, which is mainly sensitive towards electrochemical processes. This sensitivity can be exploited for model parameterization and validation. A general analysis of EPIS is presented, which shows the necessity of model-based interpretation of the complex EPIS shapes in the Nyquist plot (cf. Figure). We then present EPIS simulations for two different electrochemical cells: (1) a sodium/oxygen battery cell and (2) a hydrogen/air fuel cell. We use 1D or 2D electrochemical and transport models to simulate current excitation/pressure detection or pressure excitation/voltage detection. The results are compared to first EPIS experimental data available in literature [2,3].
Zerstörungsfreie Verfahren zur Messung von Eigenspannungen erfordern, abhängig vom gewählten Verfahren, die Kenntnis gewisser Kopplungskonstanten. Im Falle von Ultraschallmessverfahren sind das neben den elastischen Konstanten zweiter Ordnung (SOEC) vor allem die Konstanten dritter Ordnung (TOEC). Elastische Konstanten fester, metallischer Bauteile werden in der Regel in Zugversuchen bestimmt. Zur Ermittlung der TOEC werden diese mit Ultraschallmessmethoden kombiniert. Durch äußere Einflüsse, wie etwa mechanische Nachbehandlungen der zu untersuchenden Bauteile können sich diese Konstanten jedoch ändern und müssen folglich direkt am veränderten Material bestimmt werden. Mithilfe von Simulationen wird die Ausbreitung der zweiten Harmonischen und der nichtlinear erzeugten Oberflächenwellen in Wellenmischexperimenten analysiert und der akustische Nichtlinearitätsparameter (ANP) bzw. der Kopplungsparameter aus der Amplitudenentwicklung berechnet. Insbesondere wird untersucht, welchen Einfluss ein gegebenes Tiefenprofil der TOEC auf den ANP hat (Vorwärtsproblem) und inwiefern sich aus den Messungen des ANP auf ein vorliegendes Tiefenprofil der TOEC schließen lässt (inverses Problem). Außerdem wird diskutiert, welchen Einfluss lokale Änderungen der SOEC auf den ANP haben können und wie groß diese Änderungen sein dürfen, um die TOEC dennoch bestimmen zu können. Die Untersuchungen hierzu wurden auf der Basis eines 3D-FEM Modells mit zufällig orientierten Mikrorissen durchgeführt. Die numerischen Rechnungen zeigen dabei auch eine gute Übereinstimmung mit einem aus der Literatur bekannten und für dieses Problem erweiterten, analytischen Modell. Neben der rissinduzierten Nichtlinearität kann bei diesem auch die Gitternichtlinearität berücksichtigt werden.
Elastic constants of components are usually determined by tensile tests in combination with ultrasonic experiments. However, these properties may change due to e.g. mechanical treatments or service conditions during their lifetime. Knowledge of the actual material parameters is key to the determination of quantities like residual stresses present in the medium. In this work the acoustic nonlinearity parameter (ANP) for surface acoustic waves is examined through the derivation of an evolution equation for the amplitude of the second harmonic. Given a certain depth profile of the third-order elastic constants, the dependence of the ANP with respect to the input frequency is determined and on the basis of these results, an appropriate inversion method is developed. This method is intended for the extraction of the depth dependence of the third-order elastic constants of the material from second-harmonic generation and guided wave mixing experiments, assuming that the change in the linear Rayleigh wave velocity is small. The latter assumption is supported by a 3D-FEM model study of a medium with randomly distributed microcracks as well as theoretical works on this topic in the literature.
The growing complexity in RF front-ends, which support carrier aggregation and a growing number of frequency bands, leads to tightened nonlinearity requirements in all sub-components. The generation of third order intermodulation products (IMD3) are typical problems caused by the non-linearity of SAW devices. In the present work, we investigate temperature compensating (TC) SAW devices on Lithium Niobate-rot128YX. An accurate FEM simulation model [1] is employed, which allows to better understand the origin of nonlinearities in such acoustic devices.