Refine
Year of publication
- 2017 (87) (remove)
Document Type
- Conference Proceeding (87) (remove)
Conference Type
- Konferenzartikel (58)
- Konferenz-Abstract (22)
- Konferenz-Poster (3)
- Sonstiges (3)
- Konferenzband (1)
Has Fulltext
- no (87) (remove)
Is part of the Bibliography
- yes (87)
Keywords
- CST (4)
- HF-Ablation (4)
- CRT (3)
- RoboCup (3)
- Gamification (2)
- IVD (2)
- Affective Computing (1)
- Aktivierung (1)
- Arbeitswissenschaft (1)
- Computer Games (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (36)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (26)
- Fakultät Wirtschaft (W) (13)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (12)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (8)
- ACI - Affective and Cognitive Institute (4)
- WLRI - Work-Life Robotics Institute (4)
- Zentrale Einrichtungen (2)
- INES - Institut für nachhaltige Energiesysteme (1)
Open Access
- Open Access (42)
- Closed Access (40)
- Bronze (5)
- Closed (4)
- Grün (1)
Heart rhythm model and simulation of electrophysiological studies and high-frequency ablations
(2017)
Background: The simulation of complex cardiologic structures has the potential to replace clinical studies due to its high efficiency regarding time and costs. Furthermore, the method is more careful for the patients’ health than the conventional ways. The aim of the study was to create an anatomic CAD heart rhythm model (HRM) as accurate as possible, and to show its usefulness for cardiac electrophysiological studies (EPS) and high-frequency (HF) ablations.
Methods: All natural heart components of the new HRM were based on MRI records, which guaranteed electronic functionality. The software CST (Computer Simulation Technology, Darmstadt) was used for the construction, while CST’s material library assured genuine tissue properties. It should be applicable to simulate different heart rhythm diseases as well as various diffusions of electromagnetic fields, caused by electrophysiological conduction, inside the heart tissue.
Results: It was achievable to simulate normal sinus rhythm and fourteen different heart rhythm disturbance with different atrial and ventricular conduction delays. The simulated biological excitation of healthy and sick HRM were plotted by simulated electrodes of four polar right atrial catheter, six polar His bundle catheter, ten polar coronary sinus catheter, four polar ablation catheter and eight polar transesophageal left cardiac catheter (Fig.). Accordingly, six variables were rebuilt and inserted into the anatomic HRM in order to establish heart catheters for ECG monitoring and HF ablation. The HF ablation catheters made it possible to simulate various types of heart rhythm disturbance ablations with different HF ablation catheters and also showed a functional visualisation of tissue heating. The use of tetrahedral meshing HRM made it attainable to store the results faster accompanied by a higher degree of space saving. The smart meshing function reduced unnecessary high resolutions for coarse structures.
Conclusions: The new HRM for EPS simulation may be additional useful for simulation of heart rhythm disturbance, cardiac pacing, HF ablation and for locating and identification of complex fractioned signals within the atrium during atrial fibrillation HF ablation.
Heart rhythm model and simulation of electrophysiological studies and high-frequency ablations
(2017)
Background: Target of the study was to create an accurate anatomic CAD heart rhythm model, and to show its usefulness for cardiac electrophysiological studies and high-frequency ablations. The method is more careful for the patients’ health and has the potential to replace clinical studies due to its high efficiency regarding time and costs.
Methods: All natural heart components of the new HRM were based on MRI records, which guaranteed electronic functionality. The software CST was used for the construction, while CST’s material library assured genuine tissue properties. It should be applicable to simulate different heart rhythm diseases as well as various diffusions of electromagnetic fields, caused by electrophysiological conduction, inside the heart tissue.
Results: It was achievable to simulate sinus rhythm and fourteen different heart rhythm disturbance with different atrial and ventricular conduction delays. The simulated biological excitation of healthy and sick HRM were plotted by simulated electrodes of four polar right atrial catheter, six polar His bundle catheter, ten polar coronary sinus catheter, four polar ablation catheter and eight polar transesophageal left cardiac catheter. Accordingly, six variables were rebuilt and inserted into the anatomic HRM in order to establish heart catheters for ECG monitoring and HF ablation. The HF ablation catheters made it possible to simulate various types of heart rhythm disturbance ablations with different HF ablation catheters and also showed a functional visualisation of tissue heating. The use of tetrahedral meshing HRM made it attainable to store the results faster accompanied by a higher degree of space saving. The smart meshing function reduced unnecessary high resolutions for coarse structures.
Conclusions: The new HRM for EPS simulation may be additional useful for simulation of heart rhythm disturbance, cardiac pacing, HF ablation and for locating and identification of complex fractioned signals within the atrium during atrial fibrillation HF ablation.
Heart rhythm model and simulation of electrophysiological studies and high-frequency ablations
(2017)
Background: The simulation of complex cardiologic structures has the potential to replace clinical studies due to its high efficiency regarding time and costs. Furthermore, the method is more careful for the patients’ health than the conventional ways. The aim of the study was to create an anatomic CAD heart rhythm model (HRM) as accurate as possible, and to show its usefulness for cardiac electrophysiological studies (EPS) and high-frequency (HF) ablations.
Methods: All natural heart components of the new HRM were based on MRI records, which guaranteed electronic functionality. The software CST (Computer Simulation Technology, Darmstadt) was used for the construction, while CST’s material library assured genuine tissue properties. It should be applicable to simulate different heart rhythm diseases as well as various diffusions of electromagnetic fields, caused by electrophysiological conduction, inside the heart tissue.
Results: It was achievable to simulate normal sinus rhythm and fourteen different heart rhythm disturbance with different atrial and ventricular conduction delays. The simulated biological excitation of healthy and sick HRM were plotted by simulated electrodes of four polar right atrial catheter, six polar His bundle catheter, ten polar coronary sinus catheter, four polar ablation catheter and eight polar transesophageal left cardiac catheter (Fig.). Accordingly, six variables were rebuilt and inserted into the anatomic HRM in order to establish heart catheters for ECG monitoring and HF ablation. The HF ablation catheters made it possible to simulate various types of heart rhythm disturbance ablations with different HF ablation catheters and also showed a functional visualisation of tissue heating. The use of tetrahedral meshing HRM made it attainable to store the results faster accompanied by a higher degree of space saving. The smart meshing function reduced unnecessary high resolutions for coarse structures.
Conclusions: The new HRM for EPS simulation may be additional useful for simulation of heart rhythm disturbance, cardiac pacing, HF ablation and for locating and identification of complex fractioned signals within the atrium during atrial fibrillation HF ablation.
The paper describes the hardware and software architecture of the developed multi MEMS sensor prototype module, consisting of ARM Cortex M4 STM32F446 microcontroller unit, five 9-axis inertial measurement units MPU9255 (3D accelerometer, 3D gyroscope, 3D magnetometer and temperature sensor) and a BMP280 barometer. The module is also equipped with WiFi wireless interface (Espressif ESP8266 chip). The module is constructed in the form of a truncated pyramid. Inertial sensors are mounted on a special basement at different angles to each other to eliminate hardware sensors drifts and to provide the capability for self-calibration. The module fuses information obtained from all types of inertial sensors (acceleration, rotation rate, magnetic field and air pressure) in order to calculate orientation and trajectory. It might be used as an Inertial Measurement Unit, Vertical Reference Unit or Attitude and Heading Reference System.
Viele hochbeanspruchte Bauteile müssen zur Erfüllung ihres konstruktiven Zwecks mit Durchdringungskerben versehen werden. Infolge der gegenseitigen Wechselwirkung gelten für die Kerbwirkung dieser Art von Mehrfachkerben andere Gesetzmäßigkeiten als bei Einzelkerben. Die Weiterentwicklung der Lehre von der Tragfähigkeitsberechnung höchstbeanspruchter Maschinenelemente macht es notwendig, sich mit der Durchdringungskerbwirkung eingehend zu befassen. Thum und Svenson [1] entwickelten im Jahr 1949 ein Näherungsverfahren zur Abschätzung der Formzahl an einem zugbelasteten Stab mit Durchdringungskerben. In vielen Lehrbüchern findet dieses Verfahren Anwendung. Aus heutiger Sicht erscheint die Eignung der aus diesem Ansatz erzielten Ergebnisse als dringend überprüfungswürdig. Das thum’sche Verfahren wird unter die Lupe genommen. Der hier vorliegende Beitrag präsentiert mit Hilfe der Finiten-Elemente-Methode (FEM) neue Untersuchungsergebnisse an zugbeanspruchten Stäben mit Halbkreisnut und überlagerter Querbohrung. Diese ergaben, dass die Berechnung nach [1] Lücken aufweist. Ihr Ansatz stellt für den heutigen Entwicklungsstand eine mit zu großen Abweichungen behaftete Näherungshypothese dar.
Elastic constants of components are usually determined by tensile tests in combination with ultrasonic experiments. However, these properties may change due to e.g. mechanical treatments or service conditions during their lifetime. Knowledge of the actual material parameters is key to the determination of quantities like residual stresses present in the medium. In this work the acoustic nonlinearity parameter (ANP) for surface acoustic waves is examined through the derivation of an evolution equation for the amplitude of the second harmonic. Given a certain depth profile of the third-order elastic constants, the dependence of the ANP with respect to the input frequency is determined and on the basis of these results, an appropriate inversion method is developed. This method is intended for the extraction of the depth dependence of the third-order elastic constants of the material from second-harmonic generation and guided wave mixing experiments, assuming that the change in the linear Rayleigh wave velocity is small. The latter assumption is supported by a 3D-FEM model study of a medium with randomly distributed microcracks as well as theoretical works on this topic in the literature.
Microscale trigeneration systems are highly flexible in their operation and thus offer the technical possibility for peak load shifting in building demand side management. However to harness their potential modern control methods such as model predictive control must be implemented for their optimal scheduling. In literature the need for experimental investigation of microscale trigeneration systems to identify typical characteristics of the components and their interactions has been identified. On a real-life setup control specific information of the components is collected and lessons learnt during commissioning of the equipment is shared. The data is analysed to draw the vital characteristics of the system and it will be used for creating models of the components that can be utilised for optimal control.
eTPL: An Enhanced Version of the TLS Presentation Language Suitable for Automated Parser Generation
(2017)
The specification of the Transport Layer Security (TLS) protocol defines its own presentation language used for the purpose of semi-formally describing the structure and on-the-wire format of TLS protocol messages. This TLS Presentation Language (TPL) is more expressive and concise than natural language or tabular descriptions, but as a result of its limited objective has a number of deficiencies. We present eTPL, an enhanced version of TPL that improves its expressiveness, flexibility, and applicability to non-TLS scenarios. We first define a generic model that describes the parsing of binary data. Based on this, we propose language constructs for TPL that capture important information which would otherwise have to be picked manually from informal protocol descriptions. Finally, we briefly introduce our software tool etpl-tool which reads eTPL definitions and automatically generates corresponding message parsers in C++. We see our work as a contribution supporting sniffing, debugging, and rapid-prototyping of wired and wireless communication systems.
Für die genaue Positionsbestimmung in Innenräumen, beispielsweise in Bahnhöfen oder Einkaufszentren, soll in dem beschriebenen Projekt untersucht werden, inwiefern lokale Magnetfelder genutzt werden können, um Genauigkeit und Robustheit zu erhöhen. Hierzu wird untersucht, ob und wie kostengünstige Magnetfeldsensoren und mobile Roboterplattformen genutzt werden können, um Karten zu erstellen, die eine spätere Navigation, beispielsweise mit Smartphones oder mit anderen mobilen Geräten.