A new, small, and optimized for low power processor core named SIRIUS has been developed, simulated, synthesized to a netlist and verified. From this netlist, containing only primitives like gates and flip-flops, a mapping to an ASIC - or FPGA technology can easily be done with existing synthesizer tools, allowing very complex SOC designs with several blocks. Emulation via FPGA can be done on already simple setups and cheap hardware because of the small core size. The performance is estimated 50 MIPS on Cyclone II FPGA and about 100 MIPS on a 0.35 CMOS 5M2P technology with 4197 primitives used for the core, including a 16 x 16 multiplier. An example design of the ASIC for an electronic ePille device currently in development is shown.
A platform of an electronic capsule is being developed for multi-task medical assistant application. It includes a near field telemetry unit for bidirectional communication system of 115 KHz low carrier frequency for inductive data transmission suited for human body energy transfer. The system triggers an actuator for drug delivery in various time and release forms via wireless external control, it has the ability to record temperature, measure pH of the body (additional sensors), and retrieve data to the outside. It consists of a 32bit processor, memory, external peripheries, and detection facility. The complete system is designed to fit small-size mass medical application with low power consumption, size of 7x25mm. The system is designed, simulated and emulated on FPGA. A final layout of the complete chip design is still under progress.
Electronic pills, smart capsules or miniaturized microsystems swallowed by human beings or animals for various biomedical and diagnostic applications are growing rapidly in the last years. This paper searched out the important existing electronic pills in the market and prototypes in research centers. Further objective of this research is to develop a technology platform with enhanced feature to cover the drawback of most
capsules. The designed telemetry unit is a synchronous bidirectional communication block using continuous phase DQPSK of 115 kHz low carrier frequency for inductive data transmission suited for human body energy transfer. The communication system can assist the electronic pill to trigger an actuator for drug delivery, to record temperature, or to measure pH of the body. It consists additionally to a 32bit processor, memory, external peripheries, and detection facility. The complete system is designed to fit small-size mass medical application with low power consumption, size of 7x25mm. The system is designed, simulated and emulated on FPGA.
A new electronic capsule with bidirectional communication system is being developed for multi-task application. The capsule is designed to be a platform for medical assistant application inside the body. The designed telemetry unit is a synchronous bidirectional communication block using continuous phase DQPSK of 115 kHz low carrier frequency for inductive data transmission suited for human body energy transfer. The communication system can assist the electronic pill to trigger an actuator for drug delivery, to record temperature, or to measure pH of the body. It consists additionally to a 32bit processor, memory, external peripheries, and detection facility. The complete system is designed to fit small-size mass medical application with low power consumption, size of 7x25mm. The system is designed, simulated and emulated on FPGA. A final layout of the complete chip design is still under progress.