Refine
Year of publication
Document Type
- Article (reviewed) (64)
- Letter to Editor (30)
- Article (unreviewed) (30)
- Part of a Book (11)
- Book (7)
- Contribution to a Periodical (6)
- Conference Proceeding (5)
- Patent (2)
- Moving Images (1)
- Other (1)
Conference Type
- Konferenz-Abstract (3)
- Konferenz-Poster (1)
- Konferenzartikel (1)
Keywords
- Götz von Berlichingen (14)
- neuroprosthetics (7)
- Johann Sebastian Bach (6)
- Gehirn (5)
- 3D-CAD (4)
- Handprothese (4)
- Medizin (4)
- hand prosthesis (4)
- 3D computer-aided design (3)
- Durchblutung (3)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (89)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (60)
- POIM - Peter Osypka Institute of Medical Engineering (30)
- IUAS - Institute for Unmanned Aerial Systems (6)
- Fakultät Wirtschaft (W) (5)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (3)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (1)
- Zentrale Einrichtungen (1)
Open Access
- Open Access (56)
- Closed Access (48)
- Closed (11)
- Gold (5)
- Diamond (1)
In this paper, a concept for an anthropomorphic replacement hand cast with silicone with an integrated sensory feedback system is presented. In order to construct the personalized replacement hand, a 3D scan of a healthy hand was used to create a 3D-printed mold using computer-aided design (CAD). To allow for movement of the index and middle fingers, a motorized orthosis was used. Information about the applied force for grasping and the degree of flexion of the fingers is registered using two pressure sensors and one bending sensor in each movable finger. To integrate the sensors and additional cavities for increased flexibility, the fingers were cast in three parts, separately from the rest of the hand. A silicone adhesive (Silpuran 4200) was examined to combine the individual parts afterwards. For this, tests with different geometries were carried out. Furthermore, different test series for the secure integration of the sensors were performed, including measurements of the registered information of the sensors. Based on these findings, skin-toned individual fingers and a replacement hand with integrated sensors were created. Using Silpuran 4200, it was possible to integrate the needed cavities and to place the sensors securely into the hand while retaining full flexion using a motorized orthosis. The measurements during different loadings and while grasping various objects proved that it is possible to realize such a sensory feedback system in a replacement hand. As a result, it can be stated that the cost-effective realization of a personalized, anthropomorphic replacement hand with an integrated sensory feedback system is possible using 3D scanning and 3D printing. By integrating smaller sensors, the risk of damaging the sensors through movement could be decreased.
Background: This paper presents a novel approach for a hand prosthesis consisting of a flexible, anthropomorphic, 3D-printed replacement hand combined with a commercially available motorized orthosis that allows gripping.
Methods: A 3D light scanner was used to produce a personalized replacement hand. The wrist of the replacement hand was printed of rigid material; the rest of the hand was printed of flexible material. A standard arm liner was used to enable the user’s arm stump to be connected to the replacement hand. With computer-aided design, two different concepts were developed for the scanned hand model: In the first concept, the replacement hand was attached to the arm liner with a screw. The second concept involved attaching with a commercially available fastening system; furthermore, a skeleton was designed that was located within the flexible part of the replacement hand.
Results: 3D-multi-material printing of the two different hands was unproblematic and inexpensive. The printed hands had approximately the weight of the real hand. When testing the replacement hands with the orthosis it was possible to prove a convincing everyday functionality. For example, it was possible to grip and lift a 1-L water bottle. In addition, a pen could be held, making writing possible.
Conclusions: This first proof-of-concept study encourages further testing with users.
In the past two decades much has been published on whiplash injury, yet both the confusion regarding the condition, and the medicolegal discussion about it have increased. In this paper, functional imaging research results are summarized using MRIcroGL3D visualization software and assembled in an image comprising regions of cerebral activation and deactivation.
In the brain-cell microenvironment, diffusion plays an important role: apart from delivering glucose and oxygen from the vascular system to brain cells, it also moves informational substances between cells. The brain is an extremely complex structure of interwoven, intercommunicating cells, but recent theoretical and experimental works showed that the classical laws of diffusion, cast in the framework of porous media theory, can deliver an accurate quantitative description of the way molecules are transported through this tissue. The mathematical modeling and the numerical simulations are successfully applied in the investigation of diffusion processes in tissues, replacing the costly laboratory investigations. Nevertheless, modeling must rely on highly accurate information regarding the main parameters (tortuosity, volume fraction) which characterize the tissue, obtained by structural and functional imaging. The usual techniques to measure the diffusion mechanism in brain tissue are the radiotracer method, the real time iontophoretic method and integrative optical imaging using fluorescence microscopy. A promising technique for obtaining the values for characteristic parameters of the transport equation is the direct optical investigation using optical fibers. The analysis of these parameters also reveals how the local geometry of the brain changes with time or under pathological conditions. This paper presents a set of computations concerning the mass transport inside the brain tissue, for different types of cells. By measuring the time evolution of the concentration profile of an injected substance and using suitable fitting procedures, the main parameters characterizing the tissue can be determined. This type of analysis could be an important tool in understanding the functional mechanisms of effective drug delivery in complex structures such as the brain tissue. It also offers possibilities to realize optical imaging methods for in vitro and in vivo measurements using optical fibers. The model also may help in radiotracer biomarker models for the understanding of the mechanism of action of new chemical entities.