Refine
Year of publication
Document Type
- Conference Proceeding (18)
- Article (reviewed) (8)
- Part of a Book (2)
- Contribution to a Periodical (2)
- Report (2)
Conference Type
- Konferenzartikel (17)
- Konferenz-Abstract (1)
Is part of the Bibliography
- yes (32)
Keywords
- Demand side flexibility (2)
- Digitalization (2)
- Energie (2)
- Energy Flexibility (2)
- Energy Management (2)
- Energy systems modeling (2)
- MPC (2)
- Optimization and control (2)
- Umweltforschung (2)
- heat pump (2)
Institute
- INES - Institut für nachhaltige Energiesysteme (23)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (19)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (11)
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (5)
- CRT - Campus Research & Transfer (2)
- Zentrale Einrichtungen (2)
Open Access
- Closed Access (12)
- Open Access (11)
- Closed (8)
- Bronze (2)
- Diamond (1)
- Gold (1)
Mit dem Klimaschutzgesetz 2021 wurden von der Bundesregierung die Klimaschutzvorgaben verschärft und die Treibhausgasneutralität bis 2045 als Ziel verankert. Zur Erreichung dieses ambitionierten Ziels ist es notwendig, im Bereich der Mobilität weitgehend von Verbrennungsmotoren mit fossilen Kraftstoffen auf Elektromobilität mit regenerativ erzeugtem Strom umzusteigen. Dabei ist die zügige Bereitstellung einer ausreichenden Ladeinfrastruktur für die Elektrofahrzeuge eine große Herausforderung. Neben der Installation einer ausreichend großen Zahl von Ladepunkten selbst besteht die Herausforderung darin, diese in das bestehende Verteilungsnetz zu integrieren bzw. das Verteilungsnetz so auszubauen, dass weiter ein sicherer Netzbetrieb gewährleistet werden kann. Dabei sind insbesondere Lösungen gefragt, bei denen der Ausbau der Ladeinfrastruktur und der Netzbetriebsmittel durch intelligentes Management des Ladens so gering wie möglich gehalten wird, indem vorhandene oder neu zu installierender Hardware möglichst effizient genutzt wird.
Hier setzte das Projekt „Intelligente Ladeinfrastruktur für Elektrofahrzeuge auf dem Parkplatz der Hochschule Offenburg (INTLOG)“ (Projektlaufzeit 15.11.2020 – 30.09.2022) an. Inhalt des Projekts war es, einen Ladepark für den Parkplatz der Hochschule Offenburg mit 20 Ladepunkten à 11 kW und somit einer Gesamtladeleistung von 220 kW an einen vorhandenen Ortsnetztransformator mit 200 kW Nennleistung anzuschließen, der aber bereits von anderen Verbrauchern genutzt wurde. Das übergeordnete Ziel war es also, eine Ladeinfrastruktur von maßgeblichem Umfang in die bestehende Netzinfrastruktur ohne zusätzlichen Ausbau zu integrieren.
Dabei wurden zukunftsweisende Technologien genutzt und weiterentwickelt sowie teilweise in Praxis, im Labor und in der Computersimulation demonstriert.
Der verstärkte Einsatz von Wärmepumpen bei der Realisierung einer klimaneutralen Wärmeversorgung führt zu einer signifikanten Zunahme und Änderung der elektrischen Lasten in den Verteilnetzen. Daher gilt es, Wärmepumpen so zu steuern, dass sie Verteilnetze wenig belasten oder sogar unterstützen.
Inhalt des Projekts „PV²WP - PV Vorhersage für die netzdienliche Steuerung von Wärmepumpen“ (Projektlaufzeit 1.07.2018 – 30.06.2021) war die Demonstration eines neuen Ansatzes zur Steuerung von Heizungssystemen, die auf Wärmepumpen und thermischen Speichern basieren und in Kombination mit einer Photovoltaikanlage betrieben werden. Das übergeordnete Ziel war dabei die Verbesserung der Netzintegration und Smart-Grid-Tauglichkeit entsprechender Heizungssysteme durch eine kostengünstige Technologie bei gleichzeitiger Erhöhung der Wirtschaftlichkeit.
Dabei wurden drei zukunftsweisende Technologien in Kombination genutzt und demonstriert: wolkenkamerabasierte Kurzfristprognosen, prädiktive Steuerung und Regelung sowie machinelearning-basierte Systemmodellierung als Basis für die Optimierung. Als Demonstrationsumgebung diente mit dem Projekthaus Ulm ein real bewohntes Einfamilienhaus.Umweltforschung
Am Institut für Angewandte Forschung wird seit Jahren eine Mikroprozessorfamilie unter dem Kurznamen SIRIUS entwickelt, die inzwischen in verschiedenen Applikationen eingesetzt wird und in hohem Maß nun auch kommerziell interessant wird. Im Mittelpunkt der Arbeiten des letzten Jahrs stand die Ausreifung der Strukturen, wobei zum erstenMal auf Benchmarks zurückgegriffen werden konnte, die einen direkten Vergleich der Leistungsfähigkeit von Prozessoren ermöglicht. Als Benchmark wurde in einer Master-Arbeit von Herrn Roth der Core-Mark Benchmark für unsere SIRIUS-Architektur übersetzt, der einen direkten Vergleich mit sehr leistungsfähigen Boliden wie der ARM-Cortex-Architektur aber auch klassischen kommerziellen Produkten von Renesas wie auch von ATMEL ermöglicht.
The PHOTOPUR project aims to develop a photocatalytic process as a type of AOPs (Advanced Oxidation Processes) for the elimination of plant protection products (PPP) of the cleaning water used to wash sprayers. At INES a PV based energy supply for the photocatalytic cleaning system was developed within the framework of two bachelor theses and assembled as a demonstration unit. Then the system was step by step extended with further process automation features and pushed to a remote operating device. The final system is now available as a mobile unit mounted on a lab table. The latest step was the photocatalytic reactor module which completed the first PHOTOPUR prototype. The system is actually undergoing an intensive testing phase with performance checks at the consortium partners. First results give an overview about the successful operation.
A balcony photovoltaic (PV) system, also known as a micro-PV system, is a small PV system consisting of one or two solar modules with an output of 100–600 Wp and a corresponding inverter that uses standard plugs to feed the renewable energy into the house grid. In the present study we demonstrate the integration of a commercial lithium-ion battery into a commercial micro-PV system. We firstly show simulations over one year with one second time resolution which we use to assess the influence of battery and PV size on self-consumption, self-sufficiency and the annual cost savings. We then develop and operate experimental setups using two different architectures for integrating the battery into the micro-PV system. In the passive hybrid architecture, the battery is in parallel electrical connection to the PV module. In the active hybrid architecture, an additional DC-DC converter is used. Both architectures include measures to avoid maximum power point tracking of the battery by the module inverter. Resulting PV/battery/inverter systems with 300 Wp PV and 555 Wh battery were tested in continuous operation over three days under real solar irradiance conditions. Both architectures were able to maintain stable operation and demonstrate the shift of PV energy from the day into the night. System efficiencies were observed comparable to a reference system without battery. This study therefore demonstrates the feasibility of both active and passive coupling architectures.
Predictive control has great potential in the home energy management domain. However, such controls need reliable predictions of the system dynamics as well as energy consumption and generation, and the actual implementation in the real system is associated with many challenges. This paper presents the implementation of predictive controls for a heat pump with thermal storage in a real single-family house with a photovoltaic rooftop system. The predictive controls make use of a novel cloud camera-based short-term solar energy prediction and an intraday prediction system that includes additional data sources. In addition, machine learning methods were used to model the dynamics of the heating system and predict loads using extensive measured data. The results of the real and simulated operation will be presented.
Soiling is an important issue in the renewable energy sector since it can result in significant yield losses, especially in regions with higher pollution or dust levels. To mitigate the impact of soiling on photovoltaic (PV) plants, it is essential to regularly monitor and clean the panels, as well as develop accurate soiling predictions that can affect cleaning strategies and enhance the overall performance of PV power plants. This research focuses on the problem of soiling loss in photovoltaic power plants and the potential to improve the accuracy of soiling predictions. The study examines how soiling can affect the efficiency and productivity of the modules and how to measure and predict soiling using machine learning (ML) algorithms. The research includes analyzing real data from large-scale ground-mounted PV sites and comparing different soiling measurement methods. It was observed that there were some deviations in the real soiling loss values compared to the expected values for some projects in southern Spain, thus, the main goal of this work is to develop machine learning models that could predict the soiling more accurately. The developed models have a low mean square error (MSE), indicating the accuracy and suitability of the models to predict the soiling rates. The study also investigates the impact of different cleaning strategies on the performance of PV power plants and provides a powerful application to predict both the soiling and the number of cleaning cycles.
Encapsulant-free N.I.C.E. modules have strong ecological advantages compared to conventional laminated modules but suffer generally from lower electrical performance. Via long-term outdoor monitoring of fullsize industrial modules of both types with identical solar cells, we investigated if the performance difference remains constant over time and which parameters influence its value. After assessing about a full year’s data, two obvious levers for N.I.C.E. optimization are identified: The usage of textured glass and transparent adhesives on the module rear side. Also, the performance loss could be alleviated using tracking systems due to lower AOI values. Our measurements show additionally that N.I.C.E. module surfaces are in average about 2.5°C cooler compared to laminated modules. With these findings, we lay out a roadmap to reduce today’s LIV gap of about 5%rel by different optimizations.