Refine
Year of publication
Document Type
- Article (reviewed) (43) (remove)
Language
- English (43)
Is part of the Bibliography
- yes (43)
Keywords
- Dünnschichtchromatographie (16)
- HPTLC (5)
- Chromatographie (4)
- Faseroptik (3)
- Belastung (2)
- Densitometrie (2)
- Diode-array detection (2)
- Fluorescence enhancement (2)
- High-performance thin-layer chromatography (2)
- Kubelka-Munk theory (2)
Institute
Open Access
- Closed Access (22)
- Open Access (7)
- Closed (4)
- Hybrid (2)
- Gold (1)
A new formula is presented for transforming fluorescence measurements in accordance with Kubelka-Munk theory. The fluorescence signals, the absorption signals, and data from a selected reference are combined in one expression. Only diode-array techniques can measure all the required data simultaneously to linearize fluorescence data correctly. To prove the new theory HPTLC quantification of the analgesic flupirtine was performed over the mass range 300 to 5000 ng per spot. The fluorescence calibration curve was linear over the whole range. The transformation of fluorescence measurements into linear mass-dependent data extends the technique of in-situ fluorescence analysis to the high concentration range. It also extends Kubelka-Munk theory from absorption to fluorescence analysis. The results presented also emphasize the importance of Kubelka-Munk theory for in-situ measurements in scattering media, especially in planar chromatography.
A Simple and Reliable HPTLC Method for the Quantification of the Intense Sweetener Sucralose®
(2003)
This paper describes a simple and fast thin layer chromatography (TLC) method for the monitoring of the relatively new intense sweetener Sucralose® in various food matrices. The method requires little or no sample preparation to isolate or concentrate the analyte. The Sucralose® extract is separated on amino‐TLC‐plates, and the analyte is derivatized “reagent‐free” by heating the developed plate for 20 min at 190°C. Spots can be measured either in the absorption or fluorescence mode. The method allows the determination of Sucralose® at the levels of interest regarding foreseen European legislation (>50 mg/kg) with excellent repeatability (RSD = 3.4%) and recovery data (95%).
Quantification of astaxanthin in salmons by chemiluminescence and absorption after TLC separation
(2018)
Astaxanthin is a keto-carotenoid, belongs to the chemical class of terpenes and is a yellow lipid soluble compound. The compound is present in marine animals like salmons and crustacean. Its colour is due to conjugated double bonds and these double bonds are responsible for its antioxidant effect. Its antioxidant activity is ten times stronger than other carotenoids and nearly 500 fold stronger than vitamin-E. We present a new thin layer chromatography (TLC) method to measure astaxanthin on TLC-plates (Merck, 1.05554) in the visible absorption range as well as by using chemiluminescence. For separation a solvent mixture of cyclohexane and acetone (10 + 2.4, v/v) was used. The RF-value of astaxanthin is 0.14.The limit of detection in vis-absorption is 64 ng / band and the limit of quantification is 92 ng/band. In chemiluminescence the values are 90 ng / band and 115 ng/band. The method offers two independently working measurement modes on a single plate which increase the accuracy of the quantification.
Enzyme‐assisted HPTLC method for the simultaneous analysis of inositol phosphates and phosphate
(2023)
Background
The analysis of myo‐inositol phosphates (InsPx) released by phytases during phytic acid degradation is challenging and time‐consuming, particularly in terms of sample preparation, isomer separation, and detection. However, a fast and robust analysis method is crucial when screening for phytases during protein engineering approaches, which result in a large number of samples, to ensure reliable identification of promising novel enzymes or target variants with improved characteristics, for example, pH range, thermal stability, and phosphate release kinetics.
Results
The simultaneous analysis of several InsPx (InsP1‐InsP4 and InsP5 + 6) as well as free phosphate was established on cellulose HPTLC plates using a buffered mobile phase. Inositol phosphates were subsequently stained using a novel enzyme‐assisted staining procedure. Immobilized InsPx were hydrolyzed by a phytase solution of Quantum® Blueliquid 5G followed by a molybdate reagent derivatization. Resulting blue zones were captured by DAD scan. The method shows good repeatability (intra‐day and intra‐lab) with maximum deviations of the Rf value of 0.01. The HPTLC method was applied to three commercially available phytases at two pH levels relevant to the gastrointestinal tract of poultry (pH 5.5 and pH 3.6) to observe their phytate degradation pattern and thus visualize their InsPx fingerprint.
Conclusion
This HPTLC method presents a semi‐high‐throughput analysis for the simultaneous analysis of phytic acid and the resulting lower inositol phosphates after its enzymatic hydrolysis and is also an effective tool to visualize the InsPx fingerprints and possible accumulations of inositol phosphates.
Fluorescence Enhancement of Pyrene Measured by Thin-Layer Chromatography with Diode-Array Detection
(2003)
In-situ densitometry for qualitative or quantitative purposes is a key step in thin-layer chromatography. It offers a simple way of quantifying by measuring the optical density of the separated spots directly on the plate. A new TLC scanner has been developed which is able to measure TLC plates or HPTLC plates, at different wavelengths simultaneously, without destroying the plate surface. The system enables absorbance and fluorescence measurements in one run. Fluorescence measurements are possible without filters or other adjustments.
The measurement of fluorescence from a TLC plate is a versatile means of making TLC analysis more sensitive. Fluorescence measurements with the new scanner are possible without filters or special lamps. Improvement of the signal-to-noise ratio is achieved by wavelength bundling. During plate scanning the scattered light and the fluorescence are both emitted from the surface of the TLC plate and this emitted light provides the desired spectral information from substances on the TLC plate. The measurement of fluorescence spectra and absorbance spectra directly from a TLC plate is based on differential measurement of light emerging from sample-free and sample-containing zones.
The literature recommends dipping TLC plates in viscous liquids to enhance fluorescence. Measurement of the fluorescence and absorbance spectra of pyrene spots reveals the mechanism of enhancement of plate dipping in viscous liquids—blocked contact of the fluorescent molecules with the stationary phase or other sample molecules is responsible for the enhanced fluorescence at lower concentrations.
In conclusion, dipping in TLC analysis is no miracle. It is based on similar mechanisms observable in liquids. The measured TLC spectra are also very similar to liquid spectra and this makes TLC spec-troscopy an important tool in separation analysis.
High performance thin layer chromatography (HPTLC) is a frequently used separation technique which works well for quantification of caffeine and quinine in beverages. Competing separation techniques, e.g. high-performance liquid chromatography (HPLC) or gas chromatography (GC), are not suitable for sugar-containing samples, because these methods need special pretreatment by the analyst. In HPTLC, however, it is possible to separate ‘dirty’ samples without time-consuming pretreatment, because disposable HPTLC plates are used. A convenient method for quantification of caffeine and quinine in beverages, without sample pretreatment, is presented below. The basic theory of in-situ quantification in HPTLC by use of remitted light is introduced and discussed. Several linearization models are discussed.
A home-made diode-array scanner has been used for quantification; this, for the first time, enables simultaneous measurements at different wavelengths. The new scanner also enables fluorescence evaluation without further equipment. Simultaneous recording at different wavelengths improves the accuracy and reliability of HPTLC analysis. These aspects result in substantial improvement of in-situ quantitative densitometric analysis and enable quantification of compounds in beverages.
A new diode-array scanner in combination with a computer-controlled application system meets all the demands of modern HPTLC measurement. Automatic application, simultaneous measurements at different wavelengths, and different linearization models enable appropriate evaluation of all analytical questions. The theory of error propagation recommends quantification at reflectance values smaller than 0.8; this can be verified only by use of diode-array scanning. The same theory also recommends quantification by use of peak height data, because the theory predicts best precision only for peak height evaluation. Diode-array scanning with reflectance monitoring enables appropriate validation in TLC and HPTLC analysis. All these aspects result in substantial improvement of in-situ quantitative densitometric analysis, and simultaneous recording at different wavelengths opens the way for chemometric evaluation, e.g. peak purity monitoring, which improves the accuracy and reliability of HPTLC analysis.
In the present study, in vitro toxicity as well as biopersistence and photopersistence of four artificial sweeteners (acesulfame, cyclamate, saccharine, and sucralose) and five antibiotics (levofloxacin, lincomycin, linezolid, marbofloxacin, and sarafloxacin) and of their phototransformation products (PTPs) were investigated. Furthermore, antibiotic activity was evaluated after UV irradiation and after exposure to inocula of a sewage treatment plant. The study reveals that most of the tested compounds and their PTPs were neither readily nor inherently biodegradable in the Organisation for Economic Co-operation and Development (OECD)-biodegradability tests. The study further demonstrates that PTPs are formed upon irradiation with an Hg lamp (UV light) and, to a lesser extent, upon irradiation with a Xe lamp (mimics sunlight). Comparing the nonirradiated with the corresponding irradiated solutions, a higher chronic toxicity against bacteria was found for the irradiated solutions of linezolid. Neither cytotoxicity nor genotoxicity was found in human cervical (HeLa) and liver (Hep-G2) cells for any of the investigated compounds or their PTPs. Antimicrobial activity of the tested fluoroquinolones was reduced after UV treatment, but it was not reduced after a 28-day exposure to inocula of a sewage treatment plant. This comparative study shows that PTPs can be formed as a result of UV treatment. The study further demonstrated that UV irradiation can be effective in reducing the antimicrobial activity of antibiotics, and consequently may help to reduce antimicrobial resistance in wastewaters. Nevertheless, the study also highlights that some PTPs may exhibit a higher ecotoxicity than the respective parent compounds. Consequently, UV treatment does not transform all micropollutants into harmless compounds and may not be a large-scale effluent treatment option.