Refine
Year of publication
Document Type
- Article (reviewed) (22)
- Article (unreviewed) (6)
- Conference Proceeding (4)
- Book (1)
- Part of a Book (1)
Conference Type
- Konferenzartikel (3)
- Konferenz-Abstract (1)
Has Fulltext
- no (34)
Is part of the Bibliography
- yes (34)
Keywords
- Dünnschichtchromatographie (18)
- Chromatographie (4)
- Faseroptik (4)
- Belastung (2)
- Densitometrie (2)
- HPTLC (2)
- Lumineszenz (2)
- Pharmazie (2)
- Quantität (2)
- Abtastung (1)
Institute
Open Access
- Closed Access (34) (remove)
We present a videodensitometric quantification method for methadone in syrup, separated by thin-layer chromatography (TLC). The quantification is based on a derivation reaction with Dragendorf reagent. Measurements were carried out using a 16-bit flatbed scanner. The range of linearity covers two magnitudes of power using the Kubelka-Munk expression for data transformation. The separation method is inexpensive, fast, and reliable.
A Simple and Reliable HPTLC Method for the Quantification of the Intense Sweetener Sucralose®
(2003)
This paper describes a simple and fast thin layer chromatography (TLC) method for the monitoring of the relatively new intense sweetener Sucralose® in various food matrices. The method requires little or no sample preparation to isolate or concentrate the analyte. The Sucralose® extract is separated on amino‐TLC‐plates, and the analyte is derivatized “reagent‐free” by heating the developed plate for 20 min at 190°C. Spots can be measured either in the absorption or fluorescence mode. The method allows the determination of Sucralose® at the levels of interest regarding foreseen European legislation (>50 mg/kg) with excellent repeatability (RSD = 3.4%) and recovery data (95%).
Quantification of astaxanthin in salmons by chemiluminescence and absorption after TLC separation
(2018)
Astaxanthin is a keto-carotenoid, belongs to the chemical class of terpenes and is a yellow lipid soluble compound. The compound is present in marine animals like salmons and crustacean. Its colour is due to conjugated double bonds and these double bonds are responsible for its antioxidant effect. Its antioxidant activity is ten times stronger than other carotenoids and nearly 500 fold stronger than vitamin-E. We present a new thin layer chromatography (TLC) method to measure astaxanthin on TLC-plates (Merck, 1.05554) in the visible absorption range as well as by using chemiluminescence. For separation a solvent mixture of cyclohexane and acetone (10 + 2.4, v/v) was used. The RF-value of astaxanthin is 0.14.The limit of detection in vis-absorption is 64 ng / band and the limit of quantification is 92 ng/band. In chemiluminescence the values are 90 ng / band and 115 ng/band. The method offers two independently working measurement modes on a single plate which increase the accuracy of the quantification.
Quantitative Bestimmung von Clozapin im Serum mittels Dioden-Array Dünnschichtchromatographie
(2003)
In thin-layer chromatography the development step distributes the sample throughout the layer, a process which strongly affects the reflection signals. The essential requirement for quantitative thinlayer chromatography is not a constant sample concentration but constant sample distribution in each sample spot. This makes evaporation of the mobile phase extremely important, because all tracks of a TLC plate must be dried uniformly. This paper shows that quantitative TLC is possible even if the concentration of the sample is not constant throughout the layer or if the distribution of the sample is not known. With uniform sample distribution, classical Kubelka-Munk theory is valid for isotropic scattering only. In the absence of this constraint classical Kubelka-Munk theory must be extended to situations where scattering is asymmetric. This can be achieved by modification of the original Kubelka-Munk equation. Extended theory is presented which is not only capable of describing asymmetrical scattering in TLC layers but also includes a formula for absorption and fluorescence in diode-array TLC. With this new theory all different formulas for diode-array thin-layer chromatographic evaluation are combined in one expression.
Thin-layer chromatography (TLC) is a well-established and widely used separation technique. Most undergraduate students of chemistry or food science used TLC as a primitive separation tool, which does not need more than small pieces of TLC plates, a glass jar and some solvents. TLC has evolved from a simple separation method of the past into an instrumental technique that offers automation, reproducibility and accurate quantification for a wide variety of applications [1]. The use of modern 10*10 cm TLC plates with narrow particle size distribution is called high performance thin layer chromatography (HPTLC), to distinguish the method from the use of traditional 20 20 cm TLC plates.
Diode-array planar chromatography is a versatile tool for identification of pharmaceutical substances In this paper thirty-three compounds with benzodiazepine properties were investigated and the separating conditions for silica gel HPTLC plates and three mobile phases were optimized. Diode-array HPTLC makes it possible to identify all the compounds with high certainty down to a level of 20 ng. An algorithm for spectral recognition which is combined with R F values from the three separation steps into one fit factor is presented. This set of data is unique for each of the compounds investigated and enables unequivocal identification. The method is rapid, inexpensive, and sensitive down to a level of 20 ng mL −1.
An interlaboratory comparison was carried out to evaluate the effectiveness of a method based on HPTLC in which reagent-free derivatization is followed by UV/fluorescence detection. The method was tested for the determination of sucralose (C12H19C13O8; (2R,3R,4R,5S,6R)-2-[(2R,3S,4S,5S)-2,5-bis(chloromethyl)-3,4-dihydroxyoxolan-2-yl]oxy-5-chloro-6-hydroxymethyl)oxane-3, 4-diol; CAS Registry No. 56038-13-2) in carbonated and still beverages at the proposed European regulatory limits. For still beverages, a portion of the sample was diluted with methanol-water. For carbonated beverages, a portion of the sample was degassed in an ultrasonic bath before dilution. Turbid beverages were filtered after dilution through an HPLC syringe filter. The separation of sucralose was performed by direct application on amino-bonded (NH2) silica gel HPTLC plates (no cleanup needed) with the mobile phase acetonitrile-water. Sucralose was determined after reagent-free derivatization at 190 degrees C; it was quantified by measurements of both UV absorption and fluorescence. The samples, both spiked and containing sucralose, were sent to 14 laboratories in five different countries. Test portions of a sample found to contain no sucralose were spiked at levels of 30.5, 100.7, and 299 mg/L. Recoveries ranged from 104.3 to 124.6% and averaged 112% for determination by UV detection; recoveries ranged from 98.4 to 101.3% and averaged 99.9% for determination by fluorescence detection. On the basis of the results for spiked samples (blind duplicates at three levels), as well as sucralose-containing samples (blind duplicates at three levels and one split level), the values for the RSDr ranged from 10.3 to 31.4% for determinations by UV detection and from 8.9 to 15.9% for determinations by fluorescence detection. The values for the RSDR values ranged from 13.5 to 31.4% for determinations by UV detection and from 8.9 to 20.7% for determinations by fluorescence detection.
In the present study, in vitro toxicity as well as biopersistence and photopersistence of four artificial sweeteners (acesulfame, cyclamate, saccharine, and sucralose) and five antibiotics (levofloxacin, lincomycin, linezolid, marbofloxacin, and sarafloxacin) and of their phototransformation products (PTPs) were investigated. Furthermore, antibiotic activity was evaluated after UV irradiation and after exposure to inocula of a sewage treatment plant. The study reveals that most of the tested compounds and their PTPs were neither readily nor inherently biodegradable in the Organisation for Economic Co-operation and Development (OECD)-biodegradability tests. The study further demonstrates that PTPs are formed upon irradiation with an Hg lamp (UV light) and, to a lesser extent, upon irradiation with a Xe lamp (mimics sunlight). Comparing the nonirradiated with the corresponding irradiated solutions, a higher chronic toxicity against bacteria was found for the irradiated solutions of linezolid. Neither cytotoxicity nor genotoxicity was found in human cervical (HeLa) and liver (Hep-G2) cells for any of the investigated compounds or their PTPs. Antimicrobial activity of the tested fluoroquinolones was reduced after UV treatment, but it was not reduced after a 28-day exposure to inocula of a sewage treatment plant. This comparative study shows that PTPs can be formed as a result of UV treatment. The study further demonstrated that UV irradiation can be effective in reducing the antimicrobial activity of antibiotics, and consequently may help to reduce antimicrobial resistance in wastewaters. Nevertheless, the study also highlights that some PTPs may exhibit a higher ecotoxicity than the respective parent compounds. Consequently, UV treatment does not transform all micropollutants into harmless compounds and may not be a large-scale effluent treatment option.