Die Kenntnis der Messunsicherheit verbessert die Aussagekraft von Einsatzhärtungstiefe-Messungen. Ausgehend von der Definition in der DIN EN ISO 2639:2002 wird unter Anwendung des „Guide to the Expression of Uncertainty in Measurement“ die Messunsicherheit abgeschätzt. Dazu werden die Einflüsse der Härteprüfung, der Positionierung der Prüfpunkte und der Probe berücksichtigt. Das Verfahren wird an zwei Beispielen angewendet: Zunächst werden die gemäß Norm zulässigen Toleranzen vollständig ausgenutzt, anschließend die Unsicherheit eines automatisierten Härteprüfers experimentell ermittelt. In beiden Fällen dominiert der Probeneinfluss das Ergebnis.
This article presents a comparative experimental study of the electrical, structural and chemical properties of large‐format, 180 Ah prismatic lithium iron phosphate (LFP)/graphite lithium‐ion battery cells from two different manufacturers. These cells are particularly used in the field of stationary energy storage such as home‐storage systems. The investigations include (1) cell‐to‐cell performance assessment, for which a total of 28 cells was tested from each manufacturer, (2) electrical charge/discharge characteristics at different currents and ambient temperatures, (3) internal cell geometries, components, and weight analysis after cell opening, (4) microstructural analysis of the electrodes via light microscopy and scanning electron microscopy, (5) chemical analysis of the electrode materials using energy‐dispersive X‐ray spectroscopy, and (6) mathematical analysis of the electrode balances. The combined results give a detailed and comparative insight into the cell characteristics, providing essential information needed for system integration. The study also provides complete and self‐consistent parameter sets for the use in cells models needed for performance prediction or state diagnosis.
Introduction: The use of scaffolds in tissue engineering is becoming increasingly important as solutions need to be found to preserve human tissues such as bone or cartilage. Various factors, including cells, biomaterials, cell and tissue culture conditions, play a crucial role in tissue engineering. The in vivo environment of the cells exerts complex stimuli on the cells, thereby directly influencing cell behavior, including proliferation and differentiation. Therefore, to create suitable replacement or regeneration procedures for human tissues, the conditions of the cells’ natural environment should be well mimicked. Therefore, current research is trying to develop 3-dimensional scaffolds (scaffolds) that can elicit appropriate cellular responses and thus help the body regenerate or replace tissues. In this work, scaffolds were printed from the biomaterial polycaprolactone (PCL) on a 3D bioplotter. Biocompatibility testing was used to determine whether the printed scaffolds were suitable for use in tissue engineering.
Material and Methods: An Envisiontec 3D bioplotter was used to fabricate the scaffolds. For better cell-scaffold interaction, the printed polycaprolactone scaffolds were coated with type-I collagen. Three different cell types were then cultured on the scaffolds and various tests were used to investigate the biocompatibility of the scaffolds.
Results: Reproducible scaffolds could be printed from polycaprolactone. In addition, a coating process with collagen was developed, which significantly improved the cell-scaffold interaction. Biocompatibility tests showed that the PCL-collagen scaffolds are suitable for use with cells. The cells adhered to the surface of the scaffolds and as a result extensive cell growth was observed on the scaffolds. The inner part of the scaffolds, however, remained largely uninhabited. In the cytotoxicity studies, it was found that toxicity below 20% was present in some experimental runs. The determination of the compressive strength by means of the universal testing machine Z005 by ZWICK according to DIN EN ISO 604 of the scaffolds resulted in a value of 68.49 ± 0.47 MPa.
The measurement of the active material volume fraction in composite electrodes of lithium-ion battery cells is difficult due to the small (sub-micrometer) and irregular structure and multi-component composition of the electrodes, particularly in the case of blend electrodes. State-of-the-art experimental methods such as focused ion beam/scanning electron microscopy (FIB/SEM) and subsequent image analysis require expensive equipment and significant expertise. We present here a simple method for identifying active material volume fractions in single-material and blend electrodes, based on the comparison of experimental equilibrium cell voltage curve (open-circuit voltage as function of charge throughput) with active material half-cell potential curves (half-cell potential as function of lithium stoichiometry). The method requires only (i) low-current cycling data of full cells, (ii) cell opening for measurement of electrode thickness and active electrode area, and (iii) literature half-cell potentials of the active materials. Mathematical optimization is used to identify volume fractions and lithium stoichiometry ranges in which the active materials are cycled. The method is particularly useful for model parameterization of either physicochemical (e.g., pseudo-two-dimensional) models or equivalent circuit models, as it yields a self-consistent set of stoichiometric and structural parameters. The method is demonstrated using a commercial LCO–NCA/graphite pouch cell with blend cathode, but can also be applied to other blends (e.g., graphite–silicon anode).
In 4D printing an additively manufactured component is given the ability to change its shape or function under the influence of an external stimulus. To achieve this, special smart materials are used that are able to react to external stimuli in a specific way. So far, a number of different stimuli have already been investigated and initial applications have been impressively demonstrated, such as self-folding bodies and simple grippers. However, a methodical specification for the selection of the stimuli and their implementation was not yet in the foreground of the development.
The focus of this work is therefore to develop a methodical approach with which the technology of 4DP can be used in a solution- and application-oriented manner. The developed approach is based on the conventional design methodology for product development to solve given problems in a structured way. This method is extended by specific approaches under consideration of the 4D printing and smart materials.
To illustrate the developed method, it is implemented in practice using a problem definition in the form of an application example. In this example, which represents the recovery of an object from a difficult-to-access environment, the individual functions of positioning, gripping and extraction are implemented using 4D printing. The material extrusion process is used for additive manufacturing of all components of the example. Finally, the functions are successfully tested. The developed approach offers an innovative and methodical approach to systematically solve technical complex problems using 4DP and smart materials.
The core/shell 3D printing process using CPC and alginate is intended to create biodegradable scaffolds that have a similar stability to bone tissue and also offer sufficient and continuous antibiotic release. In this way, a patient-specific and patient-friendly process will be established, which should optimally support the human organism in its regeneration. To generate the best possible strength values, the printed scaffolds underwent various post-treatments and were then tested in a material test. The test methods included self-setting, storage in a drying cabinet with a water-saturated atmosphere at 37°C, followed by incubation in PBS, freeze-drying, and coating the samples with alginate. Additionally, a degradation test at pH 7.4 and pH 5 was carried out to test stability under in vitro conditions. It was shown that the untreated and freeze-dried samples failed at a maximum load of 30–700 N, while the remaining scaffolds could withstand a load of at least 2,000 N. At this failure load, most of the test series showed an average deformation of 43.95%. All samples, therefore, remained below the strength of cancellous bone. However, based on a 20% load after surgery, the coated scaffolds represented the best possible alternative, with a Young’s modulus of around 1.71 MPa. We were able to demonstrate that self-setting occurs in core-shell printed CPC/alginate scaffolds after only 1 day, and that mass production is possible. By coating with alginate, the compressive strength could be increased without the need for additional post-treatment. The mechanical strength was sufficient to be available as a scaffold for bone regeneration and additionally as a drug delivery device for future applications and experiments.
Introduction
Intervertebral disk degeneration is a growing problem in our society. The degeneration of the intervertebral disk leads to back pain and in some cases to a herniated disk. Advanced disk degeneration can be treated surgically with either a vertebral body fusion or a disk prosthesis. Vertebral body fusion is currently considered the gold standard of surgical therapy and is clearly superior to disk prosthesis based on the number of cases. The aim of this work was the 3D printing of Gyroid structures and the determination of their mechanical properties in a biomechanical feasibility study for possible use as an intervertebral disc prosthesis.
Material and methods
Creo Parametric 6.0.6.0 was used to create models with various Gyroid properties. These were printed with the Original Prusa i3 MK3s+. Different flexible filaments (TPU FlexHard and TPU FlexMed, extrudr, Lauterach, Austria) were used to investigate the effects of the filament on the printing results and mechanical properties of the models. Characterization was carried out by means of microscopy and tension/compression testing on the universal testing machine.
Results
The 3D prints with the FlexHard and FlexMid filament went without any problems. No printing errors were detected in the microscopy. The mechanical confined compression test resulted in force-deformation curves of the individual printed models. This showed that changing the Gyroid properties (increasing the wall thickness or density of the Gyroid) leads to changes in the force-deformation curves and thus to the mechanical properties.
Conlcusion
The flexible filaments used in this work showed good print quality after the printing parameters were adjusted. The mechanical properties of the discs were also promising. The parameters Gyroid volume, wall thickness of the Gyroid and the outer wall played a decisive role for both FlexMed and FlexHard. All in all, the Gyroid structured discs (Ø 50 mm) made of TPU represent a promising approach with regard to intervertebral disc replacement. We would like to continue to pursue this approach in the future.
In 4D printing, an additively manufactured component is given the ability to change its shape or function in an intended and useful manner over time. The technology of 4D printing is still in an early stage of development. Nevertheless, interesting research and initial applications exist in the literature. In this work, a novel methodical approach is presented that helps transfer existing 4D printing research results and knowledge into solving application tasks systematically. Moreover, two different smart materials are analyzed, used, and combined following the presented methodical approach to solving the given task in the form of recovering an object from a poorly accessible space. This is implemented by self-positioning, grabbing, and extracting the target object. The first smart material used to realize these tasks is a shape-memory polymer, while the second is a polymer-based magnetic composite. In addition to the presentation and detailed implementation of the methodical approach, the potentials and behavior of the two smart materials are further examined and narrowed down as a result of the investigation. The results show that the developed methodical approach contributes to moving 4D printing closer toward a viable alternative to existing technologies due to its problem-oriented nature.