Refine
Year of publication
Document Type
- Conference Proceeding (7)
- Contribution to a Periodical (6)
- Report (6)
- Article (reviewed) (1)
Conference Type
- Konferenzartikel (7)
Is part of the Bibliography
- yes (20)
Keywords
- Gebäudeklimatisierung (3)
- Fotovoltaik (2)
- Klimatechnik (2)
- Sanierung (2)
- Smart PV (2)
- Blockheizkraftwerke (1)
- Eco Sciences (1)
- Energiebewusstes Bauen (1)
- Energienetzmanagement (1)
- Energietechnik (1)
Institute
Open Access
- Open Access (16)
- Bronze (9)
- Closed Access (3)
Three real-lab trigeneration microgrids are investigated in non-residential environments (educational, office/administrational, companies/production) with a special focus on domain-specific load characteristics. For accurate load forecasting on such a local level, à priori information on scheduled events have been combined with statistical insight from historical load data (capturing information on not explicitly-known consumer behavior). The load forecasts are then used as data input for (predictive) energy management systems that are implemented in the trigeneration microgrids. In real-world applications, these energy management systems must especially be able to carry out a number of safety and maintenance operations on components such as the battery (e.g. gassing) or CHP unit (e.g. regular test runs). Therefore, energy management systems should combine heuristics with advanced predictive optimization methods. Reducing the effort in IT infrastructure the main and safety relevant management process steps are done on site using a Smart & Local Energy Controller (SLEC) assisted by locally measured signals or operator given information as default and external inputs for any advanced optimization. Heuristic aspects for local fine adjustment of energy flows are presented.
Photovoltaics Energy Prediction Under Complex Conditions for a Predictive Energy Management System
(2015)
PHOTOPUR hat die Entwicklung eines photokatalytischen Prozesses zur Beseitigung von Pflanzenschutzmitteln (PSM) aus dem Reinigungswasser von Spritzgeräten zum Ziel. Am INES wurde eine Energieversorgung für die photokatalytische Reinigung in zwei Bachelorarbeiten entwickelt und als Demosystem aufgebaut. Das Gesamtsystem ist nun als mobile Einheit verfügbar und wurde zuletzt um das Reaktormodul für den photokatalytischen Prozeß erweitert und den Partnern für intensive Tests übergeben.
The PHOTOPUR project aims to develop a photocatalytic process as a type of AOPs (Advanced Oxidation Processes) for the elimination of plant protection products (PPP) of the cleaning water used to wash sprayers. At INES a PV based energy supply for the photocatalytic cleaning system was developed within the framework of two bachelor theses and assembled as a demonstration unit. Then the system was step by step extended with further process automation features and pushed to a remote operating device. The final system is now available as a mobile unit mounted on a lab table. The latest step was the photocatalytic reactor module which completed the first PHOTOPUR prototype. The system is actually undergoing an intensive testing phase with performance checks at the consortium partners. First results give an overview about the successful operation.
An energy oriented design concept was developed within the research project PHOTOPUR which has the development of a PV powered water cleaning system as main focus. During a wine season Plant Protection Products (PPP) are several times sprayed on plants to protect them of undesired insects and herbs or avoid hazardous fungus
types. A work package of the project partner INES in Offenburg led to a design introducing energy profiling already in the early beginning of a product design. The concept is based on three pillars respecting first the
requirements of the core process making up filtering and cleaning and secondary aspects which run, support, maintain and monitor the system to secure availability and product reliability.
The presented paper shows that the results of the design tools guided the developers to assemble a functional model of the water decontamination unit which was manually tested with its concatenated steps of the water cleaning process.
Eine Besonderheit des Ende Januar 2008 abgeschlossenen Langzeitmonitoring des Solar Info Center Freiburg (Förderkennzeichen BMWi 0335007U) ist die Erweiterung des Lüftungsbetriebs mit dem gelungenen Einsatz des an der Hochschule entwickelten Konzepts einer intelligenten dynamischen Betriebsführung (idB) unter Nutzung von Expertenwissen, Simulationsrechnungen und Prognosen. Im ersten Testbetrieb im Sommer 2006 konnte in einem Teilbereich des Solar-Info-Center-Gebäudes der Energiebedarf für die Dachventilatoren um 38 % gesenkt werden. Nach Auswertungen des Testbetriebs wurde das System im Jahr 2007 für den Betrieb im gesamten Gebäude angepasst. Die Mehrkosten des Betreibers für die Nutzung dieser Optimierung belaufen sich hauptsächlich auf den Bezug von Wetterdaten eines Wetterdienstes.
Der vorliegende Leitfaden „Natürliche Gebäudeklimatisierung in Klassenzimmern“ greift einen nachhaltigen Ansatz zur deutlichen Reduzierung der sommerlichen Wärmebelastung in Klassenzimmern auf. Insbesondere die ersten sechs Jahre des 21. Jahrhunderts zeigten verstärkt Überhitzungstendenzen in sehr vielen Schulgebäuden der Region südlicher Oberrhein. In Verbindung mit der Umstellung des Schulbetriebs auf die Ganztagsschule und der deutlichen Verstärkung der Überhitzungstendenz in sanierten Gebäuden, die mit einem modernisierten Wärmeschutz versehen sind, zeigte sich für die Stadt Offenburg ein wichtiger Handlungsbedarf auf.
Aus der Kooperation der Stadt Offenburg mit der Hochschule Offenburg entwickelten sich mehrere Maßnahmenpakete bestehend aus einer Kombination bekannter physikalischer Sachverhalte und Verfahren, die mit den Möglichkeiten einer Gebäudeautomation gekoppelt werden und durch Einbindung der Nutzer in das Betriebskonzept zu einem thermisch verbesserten Arbeits- und Lernklima führen.
In vielen Schulgebäuden der Region südlicher Oberrhein zeigte sich seit Beginn dieses Jahrhunderts eine verstärkte Überhitzungstendenz. Besonders bei energetisch sanierten Schulen und durch die Umstellung des Schulbetriebs auf den Ganztagsunterricht zeigt sich eine stärkere Wärmebelastung durch die sommerlichen Temperaturen. Die Stadt Offenburg sah hier einen wichtigen Handlungsbedarf, um Klassenräume ohne den Einsatz energieintensiver Kältemaschinen thermisch zu entlasten. Durch einen deutlichen Anstieg beim Energieeinsatz für Kühlmaßnahmen würden die starken Einspareffekte bei den Heizkosten im Sommer neutralisiert. Interessant waren deshalb nachhaltige Lösungen die bei niedrigem Primärenergieeinsatz ein hohes Reduktionspotenzial bei der Kühllast bewirken. Verfahren der natürlichen Gebäudeklimatisierung führten in Zusammenarbeit mit der Forschungsgruppe nachhaltige Energietechnik der Hochschule Offenburg zu unterschiedlichen Nachtlüftungsstrategien zusammen mit ergänzenden Wärmeschutzmaßnahmen.