Optimisation based economic despatch of real-world complex energy systems demands reduced order and continuously differentiable component models that can represent their part-load behaviour and dynamic responses. A literature study of existing modelling methods and the necessary characteristics the models should meet for their successful application in model predictive control of a polygeneration system are presented. Deriving from that, a rational modelling procedure using engineering principles and assumptions to develop simplified component models is applied. The models are quantitatively and qualitatively evaluated against experimental data and their efficacy for application in a building automation and control architecture is established.
Cooling towers or recoolers are one of the major consumers of electricity in a HVAC plant. The implementation and analysis of advanced control methods in a practical application and its comparison with conventional controllers is necessary to establish a framework for their feasibility especially in the field of decentralised energy systems. A standard industrial controller, a PID and a model based controller were developed and tested in an experimental set-up using market-ready components. The characteristics of these controllers such as settling time, control difference, and frequency of control actions are compared based on the monitoring data. Modern controllers demonstrated clear advantages in terms of energy savings and higher accuracy and a model based controller was easier to set-up than a PID.
Variable refrigerant flow (VRF) and variable air volume (VAV) systems are considered among the best heating, ventilation, and air conditioning systems (HVAC) thanks to their ability to provide cooling and heating in different thermal zones of the same building. As well as their ability to recover the heat rejected from spaces requiring cooling and reuse it to heat another space. Nevertheless, at the same time, these systems are considered one of the most energy-consuming systems in the building. So, it is crucial to well size the system according to the building’s cooling and heating needs and the indoor temperature fluctuations. This study aims to compare these two energy systems by conducting an energy model simulation of a real building under a semi-arid climate for cooling and heating periods. The developed building energy model (BEM) was validated and calibrated using measured and simulated indoor air temperature and energy consumption data. The study aims to evaluate the effect of these HVAC systems on energy consumption and the indoor thermal comfort of the building. The numerical model was based on the Energy Plus simulation engine. The approach used in this paper has allowed us to reach significant quantitative energy saving along with a high level of indoor thermal comfort by using the VRF system compared to the VAV system. The findings prove that the VRF system provides 46.18% of the annual total heating energy savings and 6.14% of the annual cooling and ventilation energy savings compared to the VAV system.
Unter dem europäischen Programm Intelligent Energy for Europe (IEE) fanden sich acht europäische Partner zusammen, um im Rahmen des Projektes ThermCo Lüftungs‐ und Kühlenergiekonzepte für Nichtwohngebäude mit niedrigem Energieeinsatz im Hinblick auf die Energieeffizienz und den thermischen Raumkomfort zu bewerten. Die Analyse erfolgte auf Basis von detaillierten Langzeitmessungen über ein Betriebsjahr in acht Demonstrationsgebäuden in unterschiedlichen klimatischen Zonen Europas und einer standardisierten Datenauswertung. Im Quervergleich aller acht Gebäude werden die Kühlkonzepte gleichermaßen nach dem thermischen Kühlenergiebezug, dem thermischen Raumkomfort und dem Primärenergieeinsatz für die technische Gebäudeausrüstung und die Beleuchtung bewertet. Ein Energiekonzept ist erst dann zufriedenstellend, wenn mit möglichst geringem Energieeinsatz und bei hoher Anlageneffizienz ein guter thermischer Raumkomfort zur Verfügung gestellt werden kann. Mit entsprechenden Gebäudesignaturen werden diese Parameter in einen Zusammenhang gebracht und die Zielstellung überprüft. Detaillierte Komfortuntersuchungen nach der europäischen Komfortnorm DIN EN 15251:2007‐08 geben Hinweise auf die Wirksamkeit der eingesetzten Kühltechnologien in den jeweiligen Klimazonen. Daraus lassen sich Handlungsempfehlungen ableiten.
Buildings that are cooled and, if applicable, heated by thermo-active building systems (TABS) in combination with environmental energy have been established in the market during the last years. Many successful and efficient examples prove, that these systems can achieve a good thermal room comfort with a high energy efficiency of the plant system using environmental energy (mainly surface-near geothermal energy). However, operating experience and a systematic evaluation of several building projects demonstrate that there is potential improvement in the design, implementation, and operation of TABS systems. The article presents operating experience and a detailed evaluation of the operation performance of several non-residential buildings with thermo-active building systems with respect to thermal comfort and energy efficiency.
Experimental Investigation of the Air Exchange Effectiveness of Push-Pull Ventilation Devices
(2020)
The increasing installation numbers of ventilation units in residential buildings are driven by legal objectives to improve their energy efficiency. The dimensioning of a ventilation system for nearly zero energy buildings is usually based on the air flow rate desired by the clients or requested by technical regulations. However, this does not necessarily lead to a system actually able to renew the air volume of the living space effectively. In recent years decentralised systems with an alternating operation mode and fairly good energy efficiencies entered the market and following question was raised: “Does this operation mode allow an efficient air renewal?” This question can be answered experimentally by performing a tracer gas analysis. In the presented study, a total of 15 preliminary tests are carried out in a climatic chamber representing a single room equipped with two push-pull devices. The tests include summer, winter and isothermal supply air conditions since this parameter variation is missing till now for push-pull devices. Further investigations are dedicated to the effect of thermal convection due to human heat dissipation on the room air flow. In dependence on these boundary conditions, the determined air exchange efficiency varies, lagging behind the expected range 0.5 < εa < 1 in almost all cases, indicating insufficient air exchange including short-circuiting. Local air exchange values suggest inhomogeneous air renewal depending on the distance to the indoor apertures as well as the temperature gradients between in- and outdoor. The tested measurement set-up is applicable for field measurements.
Given the looming threats of climate change and the rapid worldwide urbanization, it is a necessity to prioritize the transition towards a carbon-free built environment. This research study provides a holistic digital methodology for parametric design of urban residential buildings with regard to the Mediterranean semi-arid climate zone of Morocco in the early design phase. The morphological parameters of the urban residential buildings, namely the buildings’ typology, the distance between buildings, the urban grid’s orientation, and the window-towall ratio, are evaluated in order to identify the key combinations of passive and active solar design strategies that determine the high energy performing configurations, based on the introduced Energy Performance Index (EPI), which is the ratio between solar BIPV production to maximum available installed BIPV capacity and the normalized thermal energy needs. Through an automated processing of 2187 iterations via Grasshopper, we simulate daylight autonomy, indoor thermal comfort and solar rooftop photovoltaic and building integrated photovoltaic (BIPV) energy potential. Then, we analyze the conflicting objectives of energy efficiency measures, active solar design strategies, and indoor visual comfort in the decision-making process that supports our goal of getting closer to net zero urban residential buildings. The digital workflow showed interesting trends in reaching a balanced equilibrium between performance metrics influenced by the contrasting impact of solar exposure on indoor daylight autonomy and thermal energy demand. Furthermore, the study’s findings indicate that it is possible to achieve an annual load match exceeding 66,56 % while simultaneously ensuring an acceptable visual indoor comfort (sDA higher than 0.4). The findings also highlight the important role of the BIPV system in shifting towards the net zero energy goal, by contributing up to 30 % of the overall solar energy output and covering up to 20 % of the yearly self-consumption. Moreover, the energy balance evaluation on an hourly basis indicates that BIPV system notably enhances the daily load cover factor by up to 5.5 %, particularly in the case of slab SN typology, throughout the different seasons. Graphical representations of the yearly, monthly and hourly load matches and the hourly energy balance of the best performing configurations provide a thorough understanding of the potential evolution of the urban energy system over time as a result of the gradual integration of active solar electricity production.
Energy efficiency and hygrothermal performance of hemp clay walls for Moroccan residential buildings
(2023)
Hemp-based building envelopes have gained significant popularity in developed countries, and now the trend of constructing houses with hemp-clay blocks is spreading to developing countries like Morocco. Investigating the hygrothermal behavior of such structures under actual climate conditions is essential for advancing and promoting this sustainable practice. This paper presents an in-depth experimental characterization of a commercial hemp-clay brick that has been exposed to the outdoor environment for four years, in addition to field measurements on a building scale demonstration prototype. Additionally, the study simulates 17 representative cities to assess the hygrothermal performance and energy-saving potential in each of Morocco's six existing climate zones, using the EnergyPlus engine. The experimental campaign's findings demonstrate excellent indoor air temperature and relative humidity regulation within the hemp-clay wall building, leading to satisfactory levels of thermal comfort within hemp-clay wall buildings. This is attributed to the material's good thermal conductivity and excellent moisture buffering capacity (found to be 0.31 W/mK and 2.25 g/m2%RH), respectively). The energy simulation findings also point to significant energy savings, with cooling and heating energy reductions ranging from 27.7% to 47.5% and 33.7% to 79.8%, respectively, as compared to traditional Moroccan buildings.
In this paper, we describe the PALM model system 6.0. PALM (formerly an abbreviation for Parallelized Large-eddy Simulation Model and now an independent name) is a Fortran-based code and has been applied for studying a variety of atmospheric and oceanic boundary layers for about 20 years. The model is optimized for use on massively parallel computer architectures. This is a follow-up paper to the PALM 4.0 model description in Maronga et al. (2015). During the last years, PALM has been significantly improved and now offers a variety of new components. In particular, much effort was made to enhance the model with components needed for applications in urban environments, like fully interactive land surface and radiation schemes, chemistry, and an indoor model. This paper serves as an overview paper of the PALM 6.0 model system and we describe its current model core. The individual components for urban applications, case studies, validation runs, and issues with suitable input data are presented and discussed in a series of companion papers in this special issue.