Refine
Year of publication
Document Type
- Conference Proceeding (19)
- Article (reviewed) (11)
- Report (4)
- Part of a Book (3)
- Book (2)
- Contribution to a Periodical (2)
Conference Type
- Konferenzartikel (17)
- Konferenz-Abstract (1)
- Sonstiges (1)
Is part of the Bibliography
- yes (41)
Keywords
- Demand side flexibility (2)
- Digitalization (2)
- Energie (2)
- Energy Flexibility (2)
- Energy Management (2)
- Energy systems modeling (2)
- MPC (2)
- Optimization and control (2)
- Umweltforschung (2)
- Wärmepumpen (2)
Institute
- INES - Institut für nachhaltige Energiesysteme (25)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (19)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (19)
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (6)
- CRT - Campus Research & Transfer (2)
- Zentrale Einrichtungen (2)
- Fakultät Medien (M) (ab 22.04.2021) (1)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (1)
Open Access
- Open Access (17)
- Closed Access (13)
- Closed (8)
- Bronze (5)
- Diamond (2)
- Gold (2)
The significant market growth of stationary electrical energy storage systems both for private and commercial applications has raised the question of battery lifetime under practical operation conditions. Here, we present a study of two 8 kWh lithium-ion battery (LIB) systems, each equipped with 14 lithium iron phosphate/graphite (LFP) single cells in different cell configurations. One system was based on a standard configuration with cells connected in series, including a cell-balancing system and a 48 V inverter. The other system featured a novel configuration of two stacks with a parallel connection of seven cells each, no cell-balancing system, and a 4 V inverter. The two systems were operated as part of a microgrid both in continuous cycling mode between 30% and 100% state of charge, and in solar-storage mode with day–night cycling. The aging characteristics in terms of capacity loss and internal resistance change in the cells were determined by disassembling the systems for regular checkups and characterizing the individual cells under well-defined laboratory conditions. As a main result, the two systems showed cell-averaged capacity losses of 18.6% and 21.4% for the serial and parallel configurations, respectively, after 2.5 years of operation with 810 (serial operation) and 881 (parallel operation) cumulated equivalent full cycles. This is significantly higher than the aging of a reference single cell cycled under laboratory conditions at 20 °C, which showed a capacity loss of only 10% after 1000 continuous full cycles.
Immunosorbent turnip vein clearing virus (TVCV) particles displaying the IgG-binding domains D and E of Staphylococcus aureus protein A (PA) on every coat protein (CP) subunit (TVCVPA) were purified from plants via optimized and new protocols. The latter used polyethylene glycol (PEG) raw precipitates, from which virions were selectively re-solubilized in reverse PEG concentration gradients. This procedure improved the integrity of both TVCVPA and the wild-type subgroup 3 tobamovirus. TVCVPA could be loaded with more than 500 IgGs per virion, which mediated the immunocapture of fluorescent dyes, GFP, and active enzymes. Bi-enzyme ensembles of cooperating glucose oxidase and horseradish peroxidase were tethered together on the TVCVPA carriers via a single antibody type, with one enzyme conjugated chemically to its Fc region, and the other one bound as a target, yielding synthetic multi-enzyme complexes. In microtiter plates, the TVCVPA-displayed sugar-sensing system possessed a considerably increased reusability upon repeated testing, compared to the IgG-bound enzyme pair in the absence of the virus. A high coverage of the viral adapters was also achieved on Ta2O5 sensor chip surfaces coated with a polyelectrolyte interlayer, as a prerequisite for durable TVCVPA-assisted electrochemical biosensing via modularly IgG-assembled sensor enzymes.
Der Einbau von Smart Metern und deren intelligente Vernetzung in Richtung eines Smart Grid wird Stromverbrauchsmuster bis in die Haushalte hinein verändern. Über die technisch geprägte Diskussion um die Komponenten dafür darf deshalb keinesfalls die Einbeziehung der Gesellschaft in den anstehenden Wandel vergessen werden. Transparenz bei den Kosten, die Förderung von Vertrauen insbesondere in die Datenschutzstandards und eine verständliche Aufklärungsarbeit sind Schlüssel für den notwendigen Dialog zwischen Energieversorgern, Politik und Bürgern.
Im Beitrag werden nach einer kurzen Einführung zu hochfesten Stählen und dem Schweißen von hochfesten Stählen die gültigen und zukünftigen Bemessungsregeln von Schweißverbindungen mit hochfesten Stählen behandelt und an Beispielen erläutert. Es werden die für den Schweißprozess wichtigen Material‐ und Gefügeeingeschaften und Herstellungsverfahren von höherfesten Stählen beschrieben und die sich daraus einstellenden Anforderungen während des Schweißvorgangs dargelegt. Anhand von Beispielen werden die derzeit gültigen Bemessungsregeln für Schweißverbindungen mit höherfesten Stählen erläutert und ein neues durch Versuche abgesichertes Bemessungsmodell für Kehlnähte vorgestellt, das es erlaubt, gezielt den wichtigen Einfluss des Schweißzusatzwerkstoffs zu erfassen. Abschließend werden die aus numerischen Schweißsimulationen gewonnenen Erkentnisse hinsichtlich Temperatur, Gefüge, Eigenspannungszustand und auch Tragverhalten einer Schweißnaht beschrieben und durch Beispiele veranschaulicht.
The conversion of space heating for private households to climate-neutral energy sources is an essential component of the energy transition, as this sector as of 2018 was responsible for 9.4 % of Germany’s carbon dioxide emissions. In addition to reducing demand through better insulation, the use of heat pumps fed with electricity from renewable energy sources, such as on-site photovoltaics (PV) systems, is an important solution approach.
Advanced energy management and control can help to make optimal use of such heating systems. Optimal here can e.g. refer to maximizing self-consumption of self-generated PV power, extended component lifetime or a grid-friendly behavior that avoids load peaks. A powerful method for this is model predictive control (MPC), which calculates optimal schedules for the controllable influence variables based on models of the system dynamics, current measurements of system states and predictions of future external influence parameters.
In this paper, we will discuss three different use cases that show how artificial intelligence can contribute to the realization of such an MPC-based energy management and control system. This will be done using the example of a real inhabited single family home that has provided the necessary data for this purpose and where the methods are implemented and tested. The heating system consists of an air-water heat pump with direct condensation, a thermal stratified storage tank, a pellet burner and a heating rod and provides both heating and hot water. The house generates a significant portion of its electricity needs through a rooftop PV system.
Predictive control has great potential in the home energy management domain. However, such controls need reliable predictions of the system dynamics as well as energy consumption and generation, and the actual implementation in the real system is associated with many challenges. This paper presents the implementation of predictive controls for a heat pump with thermal storage in a real single-family house with a photovoltaic rooftop system. The predictive controls make use of a novel cloud camera-based short-term solar energy prediction and an intraday prediction system that includes additional data sources. In addition, machine learning methods were used to model the dynamics of the heating system and predict loads using extensive measured data. The results of the real and simulated operation will be presented.
This paper focuses on appropriately measuring the accuracy of forecasts of load behavior and renewable generation in micro-grid operation. Common accuracy measures like the root mean square of the error are often difficult to interpret for system design, as they describe the mean accuracy of the forecast. Micro-grid systems, however, have to be designed to handle also worst case situations. This paper therefore suggests two error measures that are based on the maximum function and that better allow understanding worst case requirements with respect to balancing power and balancing energy supply.
Mit dem Klimaschutzgesetz 2021 wurden von der Bundesregierung die Klimaschutzvorgaben verschärft und die Treibhausgasneutralität bis 2045 als Ziel verankert. Zur Erreichung dieses ambitionierten Ziels ist es notwendig, im Bereich der Mobilität weitgehend von Verbrennungsmotoren mit fossilen Kraftstoffen auf Elektromobilität mit regenerativ erzeugtem Strom umzusteigen. Dabei ist die zügige Bereitstellung einer ausreichenden Ladeinfrastruktur für die Elektrofahrzeuge eine große Herausforderung. Neben der Installation einer ausreichend großen Zahl von Ladepunkten selbst besteht die Herausforderung darin, diese in das bestehende Verteilungsnetz zu integrieren bzw. das Verteilungsnetz so auszubauen, dass weiter ein sicherer Netzbetrieb gewährleistet werden kann. Dabei sind insbesondere Lösungen gefragt, bei denen der Ausbau der Ladeinfrastruktur und der Netzbetriebsmittel durch intelligentes Management des Ladens so gering wie möglich gehalten wird, indem vorhandene oder neu zu installierender Hardware möglichst effizient genutzt wird.
Hier setzte das Projekt „Intelligente Ladeinfrastruktur für Elektrofahrzeuge auf dem Parkplatz der Hochschule Offenburg (INTLOG)“ (Projektlaufzeit 15.11.2020 – 30.09.2022) an. Inhalt des Projekts war es, einen Ladepark für den Parkplatz der Hochschule Offenburg mit 20 Ladepunkten à 11 kW und somit einer Gesamtladeleistung von 220 kW an einen vorhandenen Ortsnetztransformator mit 200 kW Nennleistung anzuschließen, der aber bereits von anderen Verbrauchern genutzt wurde. Das übergeordnete Ziel war es also, eine Ladeinfrastruktur von maßgeblichem Umfang in die bestehende Netzinfrastruktur ohne zusätzlichen Ausbau zu integrieren.
Dabei wurden zukunftsweisende Technologien genutzt und weiterentwickelt sowie teilweise in Praxis, im Labor und in der Computersimulation demonstriert.
With increasing flexible AC transmission system (FACTS) devices in operation, like the most versatile unified power flow controller (UPFC), the AC/DC transmission flexibility and power system stability have been suffering unprecedented challenge. This paper introduces the user-defined modeling (UDM) method into the UPFC dynamic modeling process, to deal with the challenging requirements of power system operation. This has also been verified using a leading-edge stability analysis software named DSATools TM in the IEEE-39 bus benchmark system. The characteristics of steady-state and dynamic responses are compared and analyzed under different conditions. Furthermore, simulation results prove the feasibility and effectiveness of the proposed UPFC in terms of both the independent regulation of power flow and the improvement of transient stability.