INES - Institut für nachhaltige Energiesysteme
Refine
Year of publication
Document Type
- Article (reviewed) (108)
- Conference Proceeding (59)
- Article (unreviewed) (21)
- Report (19)
- Part of a Book (11)
- Contribution to a Periodical (7)
- Book (6)
- Doctoral Thesis (4)
- Master's Thesis (4)
- Patent (4)
Conference Type
- Konferenzartikel (48)
- Konferenz-Abstract (10)
- Konferenz-Poster (1)
Keywords
- Lithiumbatterie (10)
- Energieversorgung (9)
- Haustechnik (9)
- Brennstoffzelle (7)
- Wärmepumpe (7)
- Fotovoltaik (6)
- Batterie (5)
- lithium-ion battery (5)
- Bauteil (4)
- Elektrochemie (4)
Institute
Open Access
- Open Access (112)
- Closed Access (67)
- Closed (24)
- Bronze (15)
- Diamond (13)
- Gold (13)
- Grün (6)
- Hybrid (3)
Photovoltaic-heat pump (PV-HP) combinations with battery and energy management systems are becoming increasingly popular due to their ability to increase the autarchy and utilization of self-generated PV electricity. This trend is driven by the ongoing electrification of the heating sector and the growing disparity between growing electricity costs and reducing feed-in tariffs in Germany. Smart control strategies can be employed to control and optimize the heat pump operation to achieve higher self-consumption of PV electricity. This work presents the evaluation results of a smart-grid ready controlled PV-HP-battery system in a single-family household in Germany, using 1-minute-high-resolution field measurement data. Within 12 months evaluation period, a self-consumption of 43% was determined. The solar fraction of the HP amounts to 36%, enabled also due to higher set temperatures for space heating and domestic hot water production. Accordingly, the SPF decreases by 4.0% the space heating and by 5.7% in the domestic hot water mode. The combined seasonal performance factor for the heat pump system increases from 4.2 to 6.7, when only considering the electricity taken from the grid and disregarding the locally generated electricity supplied from photovoltaic and battery units.
This paper provides a comprehensive overview of approaches to the determination of isocontours and isosurfaces from given data sets. Different algorithms are reported in the literature for this purpose, which originate from various application areas, such as computer graphics or medical imaging procedures. In all these applications, the challenge is to extract surfaces with a specific isovalue from a given characteristic, so called isosurfaces. These different application areas have given rise to solution approaches that all solve the problem of isocontouring in their own way. Based on the literature, the following four dominant methods can be identified: the marching cubes algorithms, the tessellation-based algorithms, the surface nets algorithms and the ray tracing algorithms. With regard to their application, it can be seen that the methods are mainly used in the fields of medical imaging, computer graphics and the visualization of simulation results. In our work, we provide a broad and compact overview of the common methods that are currently used in terms of isocontouring with respect to certain criteria and their individual limitations. In this context, we discuss the individual methods and identify possible future research directions in the field of isocontouring.
Batteries typically consist of multiple individual cells connected in series. Here we demonstrate single-cell state of charge (SOC) and state of health (SOH) diagnosis in a 24 V class lithium-ion battery. To this goal, we introduce and apply a novel, highly efficient algorithm based on a voltage-controlled model (VCM). The battery, consisting of eight single cells, is cycled over a duration of five months under a simple cycling protocol between 20 % and 100 % SOC. The cell-to-cell standard deviations obtained with the novel algorithm were 1.25 SOC-% and 1.07 SOH-% at beginning of cycling. A cell-averaged capacity loss of 9.9 % after five months cycling was observed. While the accuracy of single-cell SOC estimation was limited (probably owed to the flat voltage characteristics of the lithium iron phosphate, LFP, chemistry investigated here), single-cell SOH estimation showed a high accuracy (2.09 SOH-% mean absolute error compared to laboratory reference tests). Because the algorithm does not require observers, filters, or neural networks, it is computationally very efficient (three seconds analysis time for the complete data set consisting of eight cells with approx. 780.000 measurement points per cell).
The nonlinear behavior of inverters is largely impacted by the interlocking and switching times. A method for online identifying the switching times of semiconductors in inverters is presented in the following work. By being able to identify these times, it is possible to compensate for the nonlinear behavior, reduce interlocking time, and use the information for diagnostic purposes. The method is first theoretically derived by examining different inverter switching cases and determining potential identification possibilities. It is then modified to consider the entire module for more robust identification. The methodology, including limitations and boundary conditions, is investigated and a comparison of two methods of measurement acquisition is provided. Subsequently the developed hardware is described and the implementation in an FPGA is carried out. Finally, the results are presented, discussed, and potential challenges are encountered.
The present work describes an extension of current slope estimation for parameter estimation of permanent magnet synchronous machines operated at inverters. The area of operation for current slope estimation in the individual switching states of the inverter is limited due to measurement noise, bandwidth limitation of the current sensors and the commutation processes of the inverter's switching operations. Therefore, a minimum duration of each switching state is necessary, limiting the final area of operation of a robust current slope estimation. This paper presents an extension of existing current slope estimation algorithms resulting in a greater area of operation and a more robust estimation result.
Electrochemical pressure impedance spectroscopy (EPIS) has received the attention of researchers as a method to study mass transport processes in polymer electrolyte mem-brane fuel cells (PEMFC). It is based on analyzing the cell voltage response to a harmonic excitation of the gas phase pressure in the frequency domain. Several experiments with a single-cell fuel cell have shown that the spectra contain information in the frequency range typical for mass transport processes and are sensitive to specific operating condi-tions and structural fuel cell parameters. To further benefit from the observed features, it is essential to identify why they occur, which to date has not yet been accomplished. The aim of the present work, therefore, is to identify causal links between internal processes and the corresponding EPIS features.
To this end, the study follows a model-based approach, which allows the analysis of inter-nal states that are not experimentally accessible. The PEMFC model is a pseudo-2D model, which connects the mass transport along the gas channel with the mass transport through the membrane electrode assembly. A modeling novelty is the consideration of the gas vol-ume inside the humidifier upstream the fuel cell inlet, which proves to be crucial for the reproduction of EPIS. The PEMFC model is parametrized to a 100 cm² single cell of the French project partner, who provided the experimental EPIS results reproduced and in-terpreted in the present study.
The simulated EPIS results show a good agreement with the experiments at current den-sities ≤ 0.4 A cm–2, where they allow a further analysis of the observed features. At the lowest excitation frequency of 1 mHz, the dynamic cell voltage response approaches the static pressure-voltage response. In the simulated frequency range between 1 mHz – 100 Hz, the cell voltage oscillation is found to strongly correlate with the partial pressure oscillation of oxygen, whereas the influence of the water pressure is limited to the low frequency region.
The two prominent EPIS features, namely the strong increase of the cell voltage oscillation and the increase of phase shift with frequency, can be traced back via the oxygen pressure to the oscillation of the inlet flow rate. The phenomenon of the oscillating inlet flow rate is a consequence of the pressure change of the gas phase inside the humidifier and in-creases with frequency. This important finding enables the interpretation of experimen-tally observed EPIS trends for a variation of operational and structural fuel cell parame-ters by tracing them back to the influence of the oscillating inlet flow rate.
The separate simulation of the time-dependent processes of the PEMFC model through model reduction shows their individual influence on EPIS. The sluggish process of the wa-ter uptake by the membrane is visible below 0.1 Hz, while the charge and discharge of the double layer becomes visible above 1 Hz. The gas transport through the gas diffusion layer is only visible above 100 Hz. The simulation of the gas transport through the gas channel
without consideration of the humidifier becomes visible above 1 Hz. With consideration of the humidifier the gas transport through the gas channel is visible throughout the fre-quency range. The strong similarity of the spectra considering the humidifier with the spectra of the full model setup shows the dominant influence of the humidifier on EPIS.
A promising observation is the change in the amplitude relationship between the cell volt-age and the oxygen partial pressure oscillation as a function of the oxygen concentration in the catalyst layer. At a frequency where the influence of oxygen pressure on the cell voltage is dominant, for example at 1 Hz, the amplitude of the cell voltage oscillation could be used to indirectly measure the oxygen concentration in the catalyst layer.
This article presents the development, parameterization, and experimental validation of a pseudo-three-dimensional (P3D) multiphysics aging model of a 500 mAh high-energy lithium-ion pouch cell with graphite negative electrode and lithium nickel manganese cobalt oxide (NMC) positive electrode. This model includes electrochemical reactions for solid electrolyte interphase (SEI) formation at the graphite negative electrode, lithium plating, and SEI formation on plated lithium. The thermodynamics of the aging reactions are modeled depending on temperature and ion concentration and the reactions kinetics are described with an Arrhenius-type rate law. Good agreement of model predictions with galvanostatic charge/discharge measurements and electrochemical impedance spectroscopy is observed over a wide range of operating conditions. The model allows to quantify capacity loss due to cycling near beginning-of-life as function of operating conditions and the visualization of aging colormaps as function of both temperature and C-rate (0.05 to 2 C charge and discharge, −20 °C to 60 °C). The model predictions are also qualitatively verified through voltage relaxation, cell expansion and cell cycling measurements. Based on this full model, six different aging indicators for determination of the limits of fast charging are derived from post-processing simulations of a reduced, pseudo-two-dimensional isothermal model without aging mechanisms. The most successful aging indicator, compared to results from the full model, is based on combined lithium plating and SEI kinetics calculated from battery states available in the reduced model. This methodology is applicable to standard pseudo-two-dimensional models available today both commercially and as open source.
Variable refrigerant flow (VRF) and variable air volume (VAV) systems are considered among the best heating, ventilation, and air conditioning systems (HVAC) thanks to their ability to provide cooling and heating in different thermal zones of the same building. As well as their ability to recover the heat rejected from spaces requiring cooling and reuse it to heat another space. Nevertheless, at the same time, these systems are considered one of the most energy-consuming systems in the building. So, it is crucial to well size the system according to the building’s cooling and heating needs and the indoor temperature fluctuations. This study aims to compare these two energy systems by conducting an energy model simulation of a real building under a semi-arid climate for cooling and heating periods. The developed building energy model (BEM) was validated and calibrated using measured and simulated indoor air temperature and energy consumption data. The study aims to evaluate the effect of these HVAC systems on energy consumption and the indoor thermal comfort of the building. The numerical model was based on the Energy Plus simulation engine. The approach used in this paper has allowed us to reach significant quantitative energy saving along with a high level of indoor thermal comfort by using the VRF system compared to the VAV system. The findings prove that the VRF system provides 46.18% of the annual total heating energy savings and 6.14% of the annual cooling and ventilation energy savings compared to the VAV system.
During pyrolysis, biomass is carbonised in the absence of oxygen to produce biochar with heat and/or electricity as co-products making pyrolysis one of the promising negative emission technologies to reach climate goals worldwide. This paper presents a simplified representation of pyrolysis and analyses the impact of this technology on the energy system. Results show that the use of pyrolysis can allow getting zero emissions with lower costs by making changes in the unit commitment of the power plants, e.g. conventional power plants are used differently, as the emissions will be compensated by biochar. Additionally, the process of pyrolysis can enhance the flexibility of energy systems, as it shows a correlation between the electricity generated by pyrolysis and the hydrogen installation capacity, being hydrogen used less when pyrolysis appears. The results indicate that pyrolysis, which is available on the market, integrates well into the energy system with a promising potential to sequester carbon.