- Diamond (2)
Unterschiedliche Stimulationszeitpunkte bei bimodaler Versorgung mit Hörgerät und Cochleaimplantat
(2023)
Die bimodale Versorgung von Patienten mit Hörgerät (HG) ipsilateral und Cochleaimplantat (CI) kontralateral bei asymmetrischem Hörverlust ist aufgrund vieler inhärenter Variablen die komplizierteste Versorgungsart im Kontext der Versorgung mit CI. Im vorliegenden Übersichtsartikel werden alle systematischen interauralen Unterschiede zwischen elektrischer und akustischer Stimulation dargestellt, die bei dieser Versorgungsart auftreten können. Darüber hinaus werden Methoden zur Quantifizierung des interauralen Latenzoffsets, also des Zeitunterschieds zwischen der akustischen und elektrischen Stimulation des Hörnervs, mittels Registrierung auditorisch evozierter Potenziale – erzeugt durch akustische bzw. elektrische Stimulation – und Messungen an den Sprachprozessoren und Hörgeräten vorgestellt. Die technische Kompensation des interauralen Latenzoffsets und ihre positive Auswirkung auf die Schalllokalisationsfähigkeit bimodal mit CI und HG versorgter Patienten wird ebenfalls beschrieben. Zuletzt werden neueste Erkenntnisse diskutiert, die Gründe dafür aufzeigen, warum die Kompensation des interauralen Latenzoffsets das Sprachverstehen im Störgeräusch bei bimodal versorgten CI-/HG-Trägern nicht verbessert.
Langzeit-EKG-Scripte
(2016)
Introduction: Subjects with mild to moderate hearing loss today often receive hearing aids (HA) with open-fitting (OF). In OF, direct sound reaches the eardrums with minimal damping. Due to the required processing delay in digital HA, the amplified HA sound follows some milliseconds later. This process occurs in both ears symmetrically in bilateral HA provision and is likely to have no or minor detrimental effect on binaural hearing. However, the delayed and amplified sound are only present in one ear in cases of unilateral hearing loss provided with one HA. This processing alters interaural timing differences in the resulting ear signals.
Methods: In the present study, an experiment with normal-hearing subjects to investigate speech intelligibility in noise with direct and delayed sound was performed to mimic unilateral and bilateral HA provision with OF.
Results: The outcomes reveal that these delays affect speech reception thresholds (SRT) in the unilateral OF simulation when presenting speech and noise from different spatial directions. A significant decrease in the median SRT from –18.1 to –14.7 dB SNR is observed when typical HA processing delays are applied. On the other hand, SRT was independent of the delay between direct and delayed sound in the bilateral OF simulation.
Discussion: The significant effect emphasizes the development of rapid processing algorithms for unilateral HA provision.
Patients with focal ventricular tachycardia are at risk of hemodynamic failure and if no treatment is provided the mortality rate can exceed 30%. Therefore, medical professionals must be adequately trained in the management of these conditions. To achieve the best treatment, the origin of the abnormality should be known, as well as the course of the disease. This study provides an opportunity to visualize various focal ventricular tachycardias using the Offenburg heart rhythm model. Modeling and simulation of focal ventricular tachycardias in the Offenburg heart rhythm model was performed using CST (Computer Simulation Technology) software from Dessault Systèms. A bundle of nerve tissue in different regions in the left and right ventricle was defined as the focus in the already existing heart rhythm model. This ultimately served as the origin of the focal excitation sites. For the simulations, the heart rhythm model was divided into a mesh consisting of 5354516 tetrahedra, which is required to calculate the electric field lines. The simulations in the Offenburg heart rhythm model were able to successfully represent the progression of focal ventricular tachycardia in the heart using measured electrical field lines. The simulation results were realized as an animated sequence of images running in real time at a frame rate of 20 frames per second. By changing the frame rate, these simulations can additionally be produced at different speeds. The Offenburg heart rhythm model allows visualization of focal ventricular arrhythmias using computer simulations.
Patients with focal ventricular tachycardia are at risk of hemodynamic failure and if no treatment is provided the mortality rate can exceed 30%. Therefore, medical professionals must be adequately trained in the management of these conditions. To achieve the best treatment, the origin of the abnormality should be known, as well as the course of the disease. This study provides an opportunity to visualize various focal ventricular tachycardias using the Offenburg cardiac rhythm model.