Refine
Year of publication
Document Type
- Conference Proceeding (71)
- Article (reviewed) (15)
- Patent (11)
- Contribution to a Periodical (8)
- Article (unreviewed) (2)
Conference Type
- Konferenz-Abstract (55)
- Konferenzartikel (12)
- Konferenz-Poster (4)
Language
- English (80)
- German (25)
- Other language (1)
- Multiple languages (1)
Is part of the Bibliography
- yes (107) (remove)
Keywords
- CST (7)
- HF-Ablation (7)
- CRT (6)
- Herzrhythmusmodell (6)
- Heart rhythm model (5)
- Herzkrankheit (5)
- Modeling and simulation (5)
- Kardiale Resynchronisationstherapie (4)
- Synchronisierung (4)
- heart rhythm model (4)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (76)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (28)
- POIM - Peter Osypka Institute of Medical Engineering (12)
- CRT - Campus Research & Transfer (2)
- Zentrale Einrichtungen (2)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (1)
Open Access
- Open Access (70)
- Closed Access (29)
- Bronze (4)
- Closed (2)
本发明涉及一种用于生物阻抗测量和/或用于神经刺激的食道电极探针(10);用于经食道心脏病治疗和/或心脏病诊断的设备(100);以及一种用于控制或调节用于心脏导管消融装置和/或心脏、循环和/或肺支持装置的方法。食道电极探针包括生物阻抗测量装置,用于测量围绕食道电极探针的组织中的至少一部分组织的生物阻抗。生物阻抗装置包括至少一个第一电极和至少一个第二电极,其中至少一个第一电极(12A)布置在食道电极探针的面向心脏的一侧(14)上,并且至少一个第二电极(12B)布置在食道电极探针背离心脏的一侧(16)上。装置(100)包括食道电极探针(10)和控制和/或评估装置(30),其被配置用于从至少一个第一电极(12A)接收第一生物阻抗测量信号并从至少一个第二电极(12B)接收第二生物阻抗测量信号,并对这些信号进行比较,并且在比较的基础上产生控制信号。该控制信号可以是用于控制或调节心脏导管消融装置和/或心脏、循环和/或肺支持装置的信号。
Die Erfindung betrifft eine Ösophaguselektrodensonde bzw. einen Ösophaguskatheter 10 zur Bioimpedanzmessung und/oder zur Neurostimulation, eine Vorrichtung 100 zur transösophagealen kardiologischen Behandlung und/oder kardiologischen Diagnose und ein Verfahren zum Steuern oder Regeln einer Ablationseinrichtung zum Durchführen einer Herzablation. Die Ösophaguselektrodensonde 10 umfasst eine Bioimpedanzmesseinrichtung zur Messung der Bioimpedanz von zumindest einem Teil des die Ösophaguselektrodensonde 10 umgebenden Gewebes. Die Bioimpedanzmesseinrichtung umfasst mindestens eine erste Elektrode 12A und mindestens eine zweite Elektrode 12B, wobei die mindestens eine erste Elektrode 12A auf einer dem Herzen zugewandten Seite 14 der Ösophaguselektrodensonde 10 angeordnet ist, und die mindestens eine zweite Elektrode 12B auf einer vom Herzen abgewandten Seite 16 der Ösophaguselektrodensonde 10 angeordnet ist.Die Vorrichtung 100 umfasst die Ösophaguselektrodensonde 10 und eine Steuer- und/oder Auswerteinrichtung 30. Die Steuer- und/oder Auswerteinrichtung 30 ist eingerichtet, ein erstes Bioimpedanzmesssignal von der mindestens einen ersten Elektrode 12A und ein zweites Bioimpedanzmesssignal von der mindestens einen zweiten Elektrode 12B zu empfangen und zu vergleichen, und ein Kontrollsignal auf Basis des Vergleichs zu generieren. Das Kontrollsignal kann ein Signal zum Steuern oder Regeln einer Ablationseinrichtung zum Durchführen einer Herzablation sein.
In cardiac resynchronization therapy (CRT) for heart failure, individualization of the AV delay is essential to improve hemodynamics and to minimize non-responder rate. In patients in sinus rhythm having additional disposition to bradycardia, optimization is necessary for both situations, atrial sensing and pacing. Therefore, echo-optimization is the goldstandard but time consuming. Unfortunately, it depends on the particular CRT systems parameter set if the resulting individually optimal AV delays can be programmed or not. Some CRT systems provide a set of AV delays for DDD operation combined with a set of the pace-sense-compensation to optimize the AV delay in DDD and VDD operation. The pace-sense-compensation (PSC) can be defined by the difference of implant-related interatrial conduction intervals in DDD and VDD operation measured in the esophageal left atrial electrogram. In a cohort of 96 CRT patients we found mean PSC of 59-35ms ranging between 0-143ms. As a consequence, allowing 10ms tolerance, AVD optimization is completely impossible in one of the two modes, VDD or DDD operation, in 34 (35%) or 5 (5%) patients with implants restricting the PSC range to 60ms or 100ms, respectively. Thus, we propose companies to provide CRT systems with programmable pace-sense- compensation between 0ms and 150ms.
Die vorliegende Erfindung betrifft Vorrichtungen zum Überwachen und Optimieren einer zeitlichen Triggerstabilität einer extrakorporalen Kreislaufunterstützung sowie Steuer- und Regeleinheiten zur extrakorporalen Kreislaufunterstützung, umfassend eine solche Vorrichtung und entsprechende Verfahren. Entsprechend wird eine Vorrichtung (10) zum Überwachen einer zeitlichen Triggerstabilität einer extrakorporalen Kreislaufunterstützung vorgeschlagen, welche dazu eingerichtet ist, einen ersten Datensatz (14) einer Messung eines EKG-Signals eines unterstützten Patienten über einen vorgegebenen Zeitraum zu empfangen. Die Vorrichtung (10) umfasst eine Auswerteeinheit (16), welche dazu eingerichtet ist, mehrere R-Trigger (26) aus dem ersten Datensatz (14) zu bestimmen oder zu identifizieren, wobei die Auswerteeinheit (16) weiterhin dazu eingerichtet ist, einen zweiten Datensatz (20) mit ausgewerteten EKG-Signalen und mehreren R-Triggern (28) zu empfangen oder bereitzustellen und den zweiten Datensatz (20) selektiv auf dem ersten Datensatz (14) abzubilden. Die Vorrichtung ist weiterhin dazu eingerichtet, ein Signal (22) auszugeben, welches kennzeichnend für einen zeitlichen Abstand sukzessiver R-Trigger (26) aus dem ersten Datensatz (14) und darauf abgebildeten sukzessiven R-Trigger (28) aus dem zweiten Datensatz (20) ist.
Background: Transesophageal left atrial (LA) pacing and transesophageal LA ECG recording are semi-invasive techniques for diagnostic and therapy of supraventricular rhythm disturbance. Cardiac resynchronization therapy (CRT) with right atrial (RA) sensed biventricular pacing is an established therapy for heart failure patients with reduced left ventricular (LV) ejection fraction, sinus rhythm and interventricular electrical desynchronization.
Purpose: The aim of the study was to evaluate electromagnetic and voltage pacing fields of the combination of RA pacing, LA pacing and biventricular pacing in patients with long interatrial and interventricular electrical desynchronization.
Methods: The modelling and electromagnetic simulations of transesophageal LA pacing in combination with RA pacing and biventricular pacing would be staged and analyzed with the CST (Computer Simulation Technology) software. Different electrodes were modelled in order to simulate different types of bipolar pacing in the 3D-CAD Offenburg heart rhythm model: The bipolar Solid S (Biotronik) electrode where modelled for RA pacing and right ventricular (RV) pacing, Attain 4194 (Medtronic) for LV pacing and TO8 (Osypka) multipolar esophageal electrode with hemispheric electrodes for LA pacing.
Results: The pacemaker amplitudes for the electromagnetic pacing simulations were performed with 3 V for RA pacing, 1.5 V for RV pacing, 50 V for LA pacing and 3V for LV pacing with pacing impulse duration of 0.5 ms for RA, RV and LV pacing and 10 ms for LA pacing. The atrioventricular pacing delay after RA pacing was 140 ms. The different pacing modes AAI, VVI, DDD, DDD0V and DDD0D were evaluated for the analysis of the electric pacing field propagation of pacemaker, CRT and LA pacing. The pacing results were compared at minimum (LOW) and maximum (HIGH) parameter settings. While the LOW setting produced fewer tetrahedral and more inaccurate results, the HIGH setting produced many tetrahedral and therefore more accurate results.
Conclusions: The simulation of the combination of transesophageal LA pacing with RA sensed biventricular pacing is possible with the Offenburg heart rhythm model. The new temporary 4-chamber pacing method may be additional useful method in CRT non-responders with long interatrial electrical delay.
Vergleich der hämodynamischen Reaktion auf VV-Delay Änderungen bei Sinusrhythmus und Vorhofflimmern
(2010)
Das Ausmaß der elektrischen ventrikulären Desynchronisation bei reduzierter linksventrikulärer Funktion ist von Bedeutung für den Erfolg der Resynchronisationstherapie der Herzinsuffizienz mit biventrikulärer Stimulation. Das Ziel der Untersuchung besteht in der nichtinvasiven Messung der elektrischen inter-ventrikulären Desynchronisation mit und ohne ischämische Herzerkrankung bei kardialen Resynchronisationstherapie Respondern. Bei Patienten mit 25,3 ± 7,3 % reduzierter linksventrikulärer Ejektionsfraktion und 166,9 ± 38,5 ms QRS-Dauer wurde das transösophageale linksventrikuläre EKG abgeleitet. Die QRS-Dauer korrelierte mit dem interventrikulären und links-ventrikulären Delay bei Resynchronisationstherapie Respondern mit nicht-ischämischer Herzerkrankung.
Cardiac resynchronization therapy is an established therapy for heart failure patients with sinus rhythm, reduced left ventricular ejection fraction and prolongation of QRS duration. The aim of the study was to evaluate ventricular desynchronization with electrical interventricular delay (IVD) to left ventricular delay (LVD) ratio in atrial fibrillation heart failure patients. IVD and LVD were measured by transesophageal posterior left ventricular ECG recording. In atrial fibrillation heart failure patients with prolonged QRS duration, the mean IVD-to-LVD-ratio was 0.84 +/- 0.42 with a range from 0.17 to 2.2 IVD-to-LVD-ratio. IVD-to-LVD-ratio correlated with QRS duration. IVD-to-LVD-ratio may be a useful parameter to evaluate electrical ventricular desynchronization in atrial fibrillation heart failure patients.
Introduction: Cardiac resynchronization therapy (CRT) with biventricular pacing (BV) is an established therapy for heart failure (HF) patients (P) with ventricular desynchronisation, but not all patients improved clinically. Aim of this study was to evaluate electrical intra-left ventricular conduction delay (LVCD) and interventricular conduction delay (IVCD), to better select patients for CRT.
Methods: 65 HF patients (age 63.4 ± 10.6 years; 7 females, 58 males) with New York Heart Association (NYHA) class 3 ± 0.2, 24.4 ± 6.7 % left ventricular (LV) ejection fraction and 167.4 ± 35.6 ms QRSD were included. Esophageal TO Osypka focused hemispherical electrodes catheter was perorally applied in position of maximum LV deflection to measure LVCD between onset and offset of LV deflection and IVCD between earliest onset of QRS in the 12-channel surface ECG and onset of LV deflection in the focused bipolar transesophageal LV electrogram.
Results: There were 50 responders with LVCD of 76.5 ± 20.4 ms, IVCD of 80.5 ± 26.1 ms (P=0.34) and QRSD of 171 ± 37.7 ms. 15 non-responders had longer LVCD of 90 ± 28.5 ms (P = 0.045), shorter IVCD of 50.1 ± 29.1 ms (P < 0.001) and QRSD of 155.3 ± 25 ms (P=0.14). During 21.3 ± 20.3 month BV pacing follow-up, the responder`s NYHA classes improved from 3 ± 0.2 to 2. ± 0.3 (P < 0.001) whereas the non-responders NYHA classes did not improve from 3 ± 0.2 to 2.9 ± 0.3 (P = 0.43) during 15.7 ± 13.9 month BV pacing follow-up (53 Boston, 10 Medtronic and 2 St. Jude CRT devices).
Conclusion: Determination of electrical LVCD and IVCD by focused bipolar transesophageal LV electrogram recording may be an additional useful technique to improve patient selection for CRT.
Transösophageales interventrikuläres Delay bei Vorhofflimmern und kardialer Resynchronisation
(2013)
Die transösophageale linksventrikuläre Elektrokardiographie ermöglicht die Evaluierung der elektrischen ventrikulären Desynchronisation im Rahmen der kardialen Resynchronisationstherapie der Herzinsuffizienz. Das Ziel der Untersuchung besteht in der präoperativen Abschätzung des transösophagealen interventrikulären Delays bei Vorhofflimmern und kardialer Resynchronisationstherapie. Bei Patienten mit Vorhofflimmern, Herzinsuffizienz New York Heart Association Klasse 3,0 ± 0,2 und QRS-Dauer 159,6 ± 23,9 ms wurde das fokusierte transösophageale linksventrikuläre EKG abgeleitet. Die kardiale Resynchronisationstherapie Responder QRS-Dauer korrelierte mit dem transösophagealen interventrikulären Delay bei Vorhofflimmern.