Refine
Year of publication
Document Type
- Article (reviewed) (285) (remove)
Is part of the Bibliography
- yes (285) (remove)
Keywords
- Dünnschichtchromatographie (17)
- Adsorption (10)
- Metallorganisches Netzwerk (9)
- Ermüdung (8)
- Plastizität (8)
- Simulation (6)
- 3D printing (5)
- Energieversorgung (5)
- HPTLC (5)
- Mikrostruktur (5)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (285) (remove)
Open Access
- Open Access (114)
- Closed Access (104)
- Closed (30)
- Gold (29)
- Hybrid (14)
- Diamond (10)
The significant market growth of stationary electrical energy storage systems both for private and commercial applications has raised the question of battery lifetime under practical operation conditions. Here, we present a study of two 8 kWh lithium-ion battery (LIB) systems, each equipped with 14 lithium iron phosphate/graphite (LFP) single cells in different cell configurations. One system was based on a standard configuration with cells connected in series, including a cell-balancing system and a 48 V inverter. The other system featured a novel configuration of two stacks with a parallel connection of seven cells each, no cell-balancing system, and a 4 V inverter. The two systems were operated as part of a microgrid both in continuous cycling mode between 30% and 100% state of charge, and in solar-storage mode with day–night cycling. The aging characteristics in terms of capacity loss and internal resistance change in the cells were determined by disassembling the systems for regular checkups and characterizing the individual cells under well-defined laboratory conditions. As a main result, the two systems showed cell-averaged capacity losses of 18.6% and 21.4% for the serial and parallel configurations, respectively, after 2.5 years of operation with 810 (serial operation) and 881 (parallel operation) cumulated equivalent full cycles. This is significantly higher than the aging of a reference single cell cycled under laboratory conditions at 20 °C, which showed a capacity loss of only 10% after 1000 continuous full cycles.
This article presents a comparative experimental study of the electrical, structural and chemical properties of large‐format, 180 Ah prismatic lithium iron phosphate (LFP)/graphite lithium‐ion battery cells from two different manufacturers. These cells are particularly used in the field of stationary energy storage such as home‐storage systems. The investigations include (1) cell‐to‐cell performance assessment, for which a total of 28 cells was tested from each manufacturer, (2) electrical charge/discharge characteristics at different currents and ambient temperatures, (3) internal cell geometries, components, and weight analysis after cell opening, (4) microstructural analysis of the electrodes via light microscopy and scanning electron microscopy, (5) chemical analysis of the electrode materials using energy‐dispersive X‐ray spectroscopy, and (6) mathematical analysis of the electrode balances. The combined results give a detailed and comparative insight into the cell characteristics, providing essential information needed for system integration. The study also provides complete and self‐consistent parameter sets for the use in cells models needed for performance prediction or state diagnosis.
We present a two-dimensional (2D) planar chromatographic separation of estrogenic active compounds on RP-18 W (Merck, 1.14296) phase. A mixture of 8 substances was separated using a solvent mix consisting of hexane, ethyl acetate, acetone (55:15:10, v/v) in the first direction and of acetone and water (15:10, v/v) in the second direction. Separation was performed on an RP-18 W plate over a distance of 70 mm. This 2D-separation method can be used to quantify 17α-ethinylestradiol (EE2) in an effect-directed analysis, using the yeast strain Saccharomyces cerevisiae BJ3505. The test strain (according to McDonnell) contains the estrogen receptor. Its activation by estrogen active compounds is measured by inducing the reporter gene lacZ which encodes the enzyme β-galactosidase. This enzyme activity is determined on plate by using the fluorescent substrate MUG (4-methylumbelliferyl-β-d-galactopyranoside).
Footwear plays a critical role in our daily lives, affecting our performance, health and overall well-being. Well-designed footwear can provide protection, comfort and improved foot functionality, while poorly designed footwear can lead to mobility problems and declines in physical activity. The overall goal of footwear research is to provide a scientific basis for professionals in the field to provide an optimal footwear solution for a given person, for a given task, in a given environment, while using sustainable manufacturing processes. This article suggests potential directions for future research with a focus on athletic footwear biomechanics. Directions include the evidence-based individualisation of footwear, the interaction between design and prolonged use, and improving the sustainability of footwear. The authors also provide a speculative outlook on methodological developments that may provide greater insight into these areas. These developments may include: (1) the use of larger scale, real-world and representative data, (2) the use of 3D printing to create experimental footwear, (3) the advancement of in silico research methods, and (4) furthering multidisciplinary collaboration. If successfully applied in the future, footwear research will contribute to active and healthy lifestyles across the lifespan.
Bewegungsanalysesysteme in der Forschung und für niedergelassene Orthopädinnen und Orthopäden
(2023)
Hintergrund
Komplexe biomechanische Bewegungsanalysen können für eine Vielzahl orthopädischer Fragestellungen wichtige Informationen liefern. Bei der Beschaffung von Bewegungsanalysesystemen sind neben den klassischen Messgütekriterien (Validität, Reliabilität, Objektivität) auch räumliche und zeitliche Rahmenbedingungen sowie Anforderungen an die Qualifikation des Messpersonals zu berücksichtigen.
Anwendung
In der komplexen Bewegungsanalyse werden Systeme zur Bestimmung der Kinematik, der Kinetik und der Muskelaktivität (Elektromyographie) eingesetzt. Der vorliegende Artikel gibt einen Überblick über Methoden der komplexen biomechanischen Bewegungsanalyse für den Einsatz in der orthopädischen Forschung oder in der individuellen Patientenversorgung. Neben dem Einsatz zur reinen Bewegungsanalyse wird auch der Einsatz von Bewegungsanalyseverfahren im Bereich des Biofeedbacktrainings diskutiert.
Beschaffung
Für die konkrete Anschaffung von Bewegungsanalysesystemen empfiehlt sich die Kontaktaufnahme mit Fachgesellschaften (z. B. Deutsche Gesellschaft für Biomechanik), Hochschulen und Universitäten mit vorhandenen Bewegungsanalyseeinrichtungen oder Vertriebsfirmen im Bereich der Biomechanik.
Treadmills are essential to the study of human and animal locomotion as well as for applied diagnostics in both sports and medicine. The quantification of relevant biomechanical and physiological variables requires a precise regulation of treadmill belt velocity (TBV). Here, we present a novel method for time-efficient tracking of TBV using standard 3D motion capture technology. Further, we analyzed TBV fluctuations of four different treadmills as seven participants walked and ran at target speeds ranging from 1.0 to 4.5 m/s. Using the novel method, we show that TBV regulation differs between treadmill types, and that certain features of TBV regulation are affected by the subjects’ body mass and their locomotion speed. With higher body mass, the TBV reductions in the braking phase of stance became higher, even though this relationship differed between locomotion speeds and treadmill type (significant body mass × speed × treadmill type interaction). Average belt speeds varied between about 98 and 103% of the target speed. For three of the four treadmills, TBV reduction during the stance phase of running was more intense (> 5% target speed) and occurred earlier (before 50% of stance phase) unlike the typical overground center of mass velocity patterns reported in the literature. Overall, the results of this study emphasize the importance of monitoring TBV during locomotor research and applied diagnostics. We provide a novel method that is freely accessible on Matlab’s file exchange server (“getBeltVelocity.m”) allowing TBV tracking to become standard practice in locomotion research.
Background: Running overuse injuries (ROIs) occur within a complex, partly injury-specific interplay between training loads and extrinsic and intrinsic risk factors. Biomechanical risk factors (BRFs) are related to the individual running style. While BRFs have been reviewed regarding general ROI risk, no systematic review has addressed BRFs for specific ROIs using a standardized methodology.
Objective: To identify and evaluate the evidence for the most relevant BRFs for ROIs determined during running and to
suggest future research directions.
Design: Systematic review considering prospective and retrospective studies. (PROSPERO_ID: 236,832).
Data Sources: PubMed. Connected Papers. The search was performed in February 2021.
Eligibility Criteria: English language. Studies on participants whose primary sport is running addressing the risk for the seven most common ROIs and at least one kinematic, kinetic (including pressure measurements), or electromyographic BRF. A BRF needed to be identified in at least one prospective or two independent retrospective studies. BRFs needed to be determined during running.
Results: Sixty-six articles fulfilled our eligibility criteria. Levels of evidence for specific ROIs ranged from conflicting to moderate evidence. Running populations and methods applied varied considerably between studies. While some BRFs appeared for several ROIs, most BRFs were specific for a particular ROI. Most BRFs derived from lower-extremity joint kinematics and kinetics were located in the frontal and transverse planes of motion. Further, plantar pressure, vertical ground reaction force loading rate and free moment-related parameters were identified as kinetic BRFs.
Conclusion: This study offers a comprehensive overview of BRFs for the most common ROIs, which might serve as a starting point to develop ROI-specific risk profiles of individual runners. We identified limited evidence for most ROI-specific risk factors, highlighting the need for performing further high-quality studies in the future. However, consensus on data collection standards (including the quantification of workload and stress tolerance variables and the reporting of injuries) is warranted.
Background: Many countries have restricted public life in order to contain the spread of the novel coronavirus (SARS-CoV2). As a side effect of related measures, physical activity (PA) levels may have decreased.
Objective: We aimed (1) to quantify changes in PA and (2) to identify variables potentially predicting PA reductions.
Methods: A systematic review with random-effects multilevel meta-analysis was performed, pooling the standardized mean differences in PA measures before and during public life restrictions.
Results: A total of 173 trials with moderate methodological quality (modified Downs and Black checklist) were identified. Compared to pre-pandemic, total PA (SMD − 0.65, 95% CI − 1.10 to − 0.21) and walking (SMD − 0.52, 95% CI − 0.29 to − 0.76) decreased while sedentary behavior increased (SMD 0.91, 95% CI: 0.17 to 1.65). Reductions in PA affected all intensities (light: SMD − 0.35, 95% CI − 0.09 to − 0.61, p = .013; moderate: SMD − 0.33, 95% CI − 0.02 to − 0.6; vigorous: SMD − 0.33, − 0.08 to − 0.58, 95% CI − 0.08 to − 0.58) to a similar degree. Moderator analyses revealed no influence of variables such as sex, age, body mass index, or health status. However, the only continent without a PA reduction was Australia and cross-sectional trials yielded higher effect sizes (p < .05).
Conclusion: Public life restrictions associated with the COVID-19 pandemic resulted in moderate reductions in PA levels and large increases in sedentary behavior. Health professionals and policy makers should therefore join forces to develop strategies counteracting the adverse effects of inactivity.
Governments have restricted public life during the COVID-19 pandemic, inter alia closing sports facilities and gyms. As regular exercise is essential for health, this study examined the effect of pandemic-related confinements on physical activity (PA) levels. A multinational survey was performed in 14 countries. Times spent in moderate-to-vigorous physical activity (MVPA) as well as in vigorous physical activity only (VPA) were assessed using the Nordic Physical Activity Questionnaire (short form). Data were obtained for leisure and occupational PA pre- and during restrictions. Compliance with PA guidelines was calculated based on the recommendations of the World Health Organization (WHO). In total, n = 13,503 respondents (39 ± 15 years, 59% females) were surveyed. Compared to pre-restrictions, overall self-reported PA declined by 41% (MVPA) and 42.2% (VPA). Reductions were higher for occupational vs. leisure time, young and old vs. middle-aged persons, previously more active vs. less active individuals, but similar between men and women. Compared to pre-pandemic, compliance with WHO guidelines decreased from 80.9% (95% CI: 80.3–81.7) to 62.5% (95% CI: 61.6–63.3). Results suggest PA levels have substantially decreased globally during the COVID-19 pandemic. Key stakeholders should consider strategies to mitigate loss in PA in order to preserve health during the pandemic.