Modeling and Simulation the Influence of Solid Carbon Formation on SOFC Performance and Degradation
(2013)
Impedance of the Surface Double Layer of LSCF/CGO Composite Cathodes: An Elementary Kinetic Model
(2014)
The significant market growth of stationary electrical energy storage systems both for private and commercial applications has raised the question of battery lifetime under practical operation conditions. Here, we present a study of two 8 kWh lithium-ion battery (LIB) systems, each equipped with 14 lithium iron phosphate/graphite (LFP) single cells in different cell configurations. One system was based on a standard configuration with cells connected in series, including a cell-balancing system and a 48 V inverter. The other system featured a novel configuration of two stacks with a parallel connection of seven cells each, no cell-balancing system, and a 4 V inverter. The two systems were operated as part of a microgrid both in continuous cycling mode between 30% and 100% state of charge, and in solar-storage mode with day–night cycling. The aging characteristics in terms of capacity loss and internal resistance change in the cells were determined by disassembling the systems for regular checkups and characterizing the individual cells under well-defined laboratory conditions. As a main result, the two systems showed cell-averaged capacity losses of 18.6% and 21.4% for the serial and parallel configurations, respectively, after 2.5 years of operation with 810 (serial operation) and 881 (parallel operation) cumulated equivalent full cycles. This is significantly higher than the aging of a reference single cell cycled under laboratory conditions at 20 °C, which showed a capacity loss of only 10% after 1000 continuous full cycles.
This article presents a comparative experimental study of the electrical, structural and chemical properties of large‐format, 180 Ah prismatic lithium iron phosphate (LFP)/graphite lithium‐ion battery cells from two different manufacturers. These cells are particularly used in the field of stationary energy storage such as home‐storage systems. The investigations include (1) cell‐to‐cell performance assessment, for which a total of 28 cells was tested from each manufacturer, (2) electrical charge/discharge characteristics at different currents and ambient temperatures, (3) internal cell geometries, components, and weight analysis after cell opening, (4) microstructural analysis of the electrodes via light microscopy and scanning electron microscopy, (5) chemical analysis of the electrode materials using energy‐dispersive X‐ray spectroscopy, and (6) mathematical analysis of the electrode balances. The combined results give a detailed and comparative insight into the cell characteristics, providing essential information needed for system integration. The study also provides complete and self‐consistent parameter sets for the use in cells models needed for performance prediction or state diagnosis.
Battery degradation is a complex physicochemical process that strongly depends on operating conditions. We present a model-based analysis of lithium-ion battery degradation in a stationary photovoltaic battery system. We use a multi-scale multi-physics model of a graphite/lithium iron phosphate (LiFePO4, LFP) cell including solid electrolyte interphase (SEI) formation. The cell-level model is dynamically coupled to a system-level model consisting of photovoltaics (PV), inverter, load, grid interaction, and energy management system, fed with historic weather data. Simulations are carried out for two load scenarios, a single-family house and an office tract, over annual operation cycles with one-minute time resolution. As key result, we show that the charging process causes a peak in degradation rate due to electrochemical charge overpotentials. The main drivers for cell ageing are therefore not only a high state of charge (SOC), but the charging process leading towards high SOC. We also show that the load situation not only influences system parameters like self-sufficiency and self-consumption, but also has a significant impact on battery ageing. We assess reduced charge cut-off voltage as ageing mitigation strategy.
Silicon (Si) has turned out to be a promising active material for next‐generation lithium‐ion battery anodes. Nevertheless, the issues known from Si as electrode material (pulverization effects, volume change etc.) are impeding the development of Si anodes to reach market maturity. In this study, we are investigating a possible application of Si anodes in low‐power printed electronic applications. Tailored Si inks are produced and the impact of carbon coating on the printability and their electrochemical behavior as printed Si anodes is investigated. The printed Si anodes contain active material loadings that are practical for powering printed electronic devices, like electrolyte gated transistors, and are able to show high capacity retentions. A capacity of 1754 mAh/gSi is achieved for a printed Si anode after 100 cycles. Additionally, the direct applicability of the printed Si anodes is shown by successfully powering an ink‐jet printed transistor.
Mass transfer phenomena in membrane fuel cells are complex and diversified because of the presence of complex transport pathways including porous media of very different pore sizes and possible formation of liquid water. Electrochemical impedance spectroscopy, although allowing valuable information on ohmic phenomena, charge transfer and mass transfer phenomena, may nevertheless appear insufficient below 1 Hz. Use of another variable, that is, back pressure, as an excitation variable for electrochemical pressure impedance spectroscopy is shown here a promising tool for investigations and diagnosis of fuel cells.
Lithium-ion battery cells exhibit a complex and nonlinear coupling of thermal, electrochemical,and mechanical behavior. In order to increase insight into these processes, we report the development of a pseudo-three-dimensional (P3D) thermo-electro-mechanical model of a commercial lithium-ion pouch cell with graphite negative electrode and lithium nickel cobalt aluminum oxide/lithium cobalt oxide blend positive electrode. Nonlinear molar volumes of the active materials as function of lithium stoichiometry are taken from literature and implemented into the open-source software Cantera for convenient coupling to battery simulation codes. The model is parameterized and validated using electrical, thermal and thickness measurements over a wide range of C-rates from 0.05 C to 10 C. The combined experimental and simulated analyses show that thickness change during cycling is dominated by intercalation-induced swelling of graphite, while swelling of the two blend components partially cancel each other. At C-rates above 2 C, electrochemistry-induced temperature increase significantly contributes to cell swelling due to thermal expansion. The thickness changes are nonlinearly distributed over the thickness of the electrode pair due to gradients in the local lithiation, which may accelerate local degradation. Remaining discrepancies between simulation and experiment at high C-rates might be attributed to lithium plating, which is not considered in the model at present.
Electrochemical pressure impedance spectroscopy (EPIS) has recently been developed as a potential diagnosis tool for polymer electrolyte membrane fuel cells (PEMFC). It is based on analyzing the frequency response of the cell voltage with respect to an excitation of the gas-phase pressure. We present here a combined modeling and experimental study of EPIS. A pseudo-twodimensional PEMFC model was parameterized to a 100 cm2 laboratory cell installed in its test bench, and used to reproduce steady-state cell polarization and electrochemical impedance spectra (EIS). Pressure impedance spectra were obtained both in experiment and simulation by applying a harmonic pressure excitation at the cathode outlet. The model shows good agreement with experimental data for current densities ⩽ 0.4 A cm−2. Here it allows a further simulative analysis of observed EPIS features, including the magnitude and shape of spectra. Key findings include a strong influence of the humidifier gas volume on EPIS and a substantial increase in oxygen partial pressure oscillations towards the channel outlet at the resonance frequency. At current densities ⩾ 0.8 A cm−2 the experimental EIS and EPIS data cannot be fully reproduced. This deviation might be associated with the formation and transport of liquid water, which is not included in the model.
Electrochemical pressure impedance spectroscopy (EPIS) is an emerging tool for the diagnosis of polymer electrolyte membrane fuel cells (PEMFC). It is based on analyzing the frequency response of the cell voltage with respect to an excitation of the gas-phase pressure. Several experimental studies in the past decade have shown the complexity of EPIS signals, and so far there is no agreement on the interpretation of EPIS features. The present study contributes to shed light into the physicochemical origin of EPIS features, by using a combination of pseudo-two-dimensional modeling and analytical interpretation. Using static simulations, the contributions of cathode equilibrium potential, cathode overpotential, and membrane resistance on the quasi-static EPIS response are quantified. Using model reduction, the EPIS responses of individual dynamic processes are predicted and compared to the response of the full model. We show that the EPIS signal of the PEMFC studied here is dominated by the humidifier. The signal is further analyzed by using transfer functions between various internal cell states and the outlet pressure excitation. We show that the EPIS response of the humidifier is caused by an oscillating oxygen molar fraction due to an oscillating mass flow rate.