Refine
Year of publication
- 2021 (74) (remove)
Document Type
- Article (reviewed) (74) (remove)
Is part of the Bibliography
- yes (74) (remove)
Keywords
- Corporate Governance (3)
- Blockchain (2)
- Götz von Berlichingen (2)
- Handprothese (2)
- Predictive maintenance (2)
- Surface acoustic waves (2)
- 3D CAD (1)
- 3D computer-aided design (1)
- 3D print (1)
- 3D printed (1)
Institute
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (31)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (28)
- POIM - Peter Osypka Institute of Medical Engineering (12)
- Fakultät Wirtschaft (W) (11)
- INES - Institut für nachhaltige Energiesysteme (9)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (7)
- Fakultät Medien (M) (ab 22.04.2021) (4)
- ACI - Affective and Cognitive Institute (2)
- WLRI - Work-Life Robotics Institute (2)
- Zentrale Einrichtungen (2)
Open Access
- Open Access (44)
- Closed Access (30)
A Hybrid Optoelectronic Sensor Platform with an Integrated Solution‐Processed Organic Photodiode
(2021)
Hybrid systems, unifying printed electronics with silicon‐based technology, can be seen as a driving force for future sensor development. Especially interesting are sensing elements based on printed devices in combination with silicon‐based high‐performance electronics for data acquisition and communication. In this work, a hybrid system integrating a solution‐processed organic photodiode in a silicon‐based system environment, which enables flexible device measurement and application‐driven development, is presented. For performance evaluation of the integrated organic photodiode, the measurements are compared to a silicon‐based counterpart. Therefore, the steady state response of the hybrid system is presented. Promising application scenarios are described, where a solution‐processed organic photodiode is fully integrated in a silicon system.
Quantifying the midsole material characteristics of athletic footwear is a standard task in footwear research and development. Current material testing protocols primarily focus on the determination of cushioning properties of the heel region or the quantification of the midsole properties as one assembly. However, midsoles possess different spatial material properties that have not been quantified from previous methodologies. Therefore, new material testing methods are required to quantify the local material response of athletic footwear. We developed a cyclical force-controlled material testing protocol for the determination of non-homogeneously distributed material stiffness with a high spatial resolution. In five prototype shoes varying in their stiffness distribution, we found that the material properties can be reliably measured across the midsole. Furthermore, we observed a characteristic non-linear material response regardless of the midsole location. We found that the material stiffness increased with an increase of the applied force and that this effect is further intensified by higher testing cycles. Additionally, the obtained midsole stiffness depends on the geometry of the midsole. We explored different approaches to reduce the measurement time of the testing protocol and found that the number of measurements can be reduced by 70% using 2 D-interpolation procedures. Determining the spatial material properties of midsoles needs to be considered to understand foot-shoe interactions. Furthermore, this measurement protocol can be used for quality control within the footwear and can be adapted for considering the effects of different running styles or speeds on ground force application characteristics.
Pure orbital blowout fractures occur within the confines of the internal orbital wall. Restoration of orbital form and volume is paramount to prevent functional and esthetic impairment. The anatomical peculiarity of the orbit has encouraged surgeons to develop implants with customized features to restore its architecture. This has resulted in worldwide clinical demand for patient-specific implants (PSIs) designed to fit precisely in the patient’s unique anatomy. Material extrusion or Fused filament fabrication (FFF) three-dimensional (3D) printing technology has enabled the fabrication of implant-grade polymers such as Polyetheretherketone (PEEK), paving the way for a more sophisticated generation of biomaterials. This study evaluates the FFF 3D printed PEEK orbital mesh customized implants with a metric considering the relevant design, biomechanical, and morphological parameters. The performance of the implants is studied as a function of varying thicknesses and porous design constructs through a finite element (FE) based computational model and a decision matrix based statistical approach. The maximum stress values achieved in our results predict the high durability of the implants, and the maximum deformation values were under one-tenth of a millimeter (mm) domain in all the implant profile configurations. The circular patterned implant (0.9 mm) had the best performance score. The study demonstrates that compounding multi-design computational analysis with 3D printing can be beneficial for the optimal restoration of the orbital floor.
Treadmills are essential to the study of human and animal locomotion as well as for applied diagnostics in both sports and medicine. The quantification of relevant biomechanical and physiological variables requires a precise regulation of treadmill belt velocity (TBV). Here, we present a novel method for time-efficient tracking of TBV using standard 3D motion capture technology. Further, we analyzed TBV fluctuations of four different treadmills as seven participants walked and ran at target speeds ranging from 1.0 to 4.5 m/s. Using the novel method, we show that TBV regulation differs between treadmill types, and that certain features of TBV regulation are affected by the subjects’ body mass and their locomotion speed. With higher body mass, the TBV reductions in the braking phase of stance became higher, even though this relationship differed between locomotion speeds and treadmill type (significant body mass × speed × treadmill type interaction). Average belt speeds varied between about 98 and 103% of the target speed. For three of the four treadmills, TBV reduction during the stance phase of running was more intense (> 5% target speed) and occurred earlier (before 50% of stance phase) unlike the typical overground center of mass velocity patterns reported in the literature. Overall, the results of this study emphasize the importance of monitoring TBV during locomotor research and applied diagnostics. We provide a novel method that is freely accessible on Matlab’s file exchange server (“getBeltVelocity.m”) allowing TBV tracking to become standard practice in locomotion research.
In recent years, physically unclonable functions (PUFs) have gained significant attraction in IoT security applications, such as cryptographic key generation and entity authentication. PUFs extract the uncontrollable production characteristics of different devices to generate unique fingerprints for security applications. When generating PUF-based secret keys, the reliability and entropy of the keys are vital factors. This study proposes a novel method for generating PUF-based keys from a set of measurements. Firstly, it formulates the group-based key generation problem as an optimization problem and solves it using integer linear programming (ILP), which guarantees finding the optimum solution. Then, a novel scheme for the extraction of keys from groups is proposed, which we call positioning syndrome coding (PSC). The use of ILP as well as the introduction of PSC facilitates the generation of high-entropy keys with low error correction costs. These new methods have been tested by applying them on the output of a capacitor network PUF. The results confirm the application of ILP and PSC in generating high-quality keys.
Governments have restricted public life during the COVID-19 pandemic, inter alia closing sports facilities and gyms. As regular exercise is essential for health, this study examined the effect of pandemic-related confinements on physical activity (PA) levels. A multinational survey was performed in 14 countries. Times spent in moderate-to-vigorous physical activity (MVPA) as well as in vigorous physical activity only (VPA) were assessed using the Nordic Physical Activity Questionnaire (short form). Data were obtained for leisure and occupational PA pre- and during restrictions. Compliance with PA guidelines was calculated based on the recommendations of the World Health Organization (WHO). In total, n = 13,503 respondents (39 ± 15 years, 59% females) were surveyed. Compared to pre-restrictions, overall self-reported PA declined by 41% (MVPA) and 42.2% (VPA). Reductions were higher for occupational vs. leisure time, young and old vs. middle-aged persons, previously more active vs. less active individuals, but similar between men and women. Compared to pre-pandemic, compliance with WHO guidelines decreased from 80.9% (95% CI: 80.3–81.7) to 62.5% (95% CI: 61.6–63.3). Results suggest PA levels have substantially decreased globally during the COVID-19 pandemic. Key stakeholders should consider strategies to mitigate loss in PA in order to preserve health during the pandemic.
Time-Sensitive Networking (TSN) is the most promising time-deterministic wired communication approach for industrial applications. To extend TSN to "IEEE 802.11" wireless networks two challenging problems must be solved: synchronization and scheduling. This paper is focused on the first one. Even though a few solutions already meet the required synchronization accuracies, they are built on expensive hardware that is not suited for mass market products. While next Wi-Fi generation might support the required functionalities, this paper proposes a novel method that makes possible high-precision wireless synchronization using commercial low-cost components. With the proposed solution, a standard deviation of synchronization error of less than 500 ns can be achieved for many use cases and system loads on both CPU and network. This performance is comparable to modern wired real-time field busses, which makes the developed method a significant contribution for the extension of the TSN protocol to the wireless domain.
A Review on Kinetic Energy Harvesting with Focus on 3D Printed Electromagnetic Vibration Harvesters
(2021)
The increasing amount of Internet of Things (IoT) devices and wearables require a reliable energy source. Energy harvesting can power these devices without changing batteries. Three-dimensional printing allows us to manufacture tailored harvesting devices in an easy and fast way. This paper presents the development of hybrid and non-hybrid 3D printed electromagnetic vibration energy harvesters. Various harvesting approaches, their utilised geometry, functional principle, power output and the applied printing processes are shown. The gathered harvesters are analysed, challenges examined and research gaps in the field identified. The advantages and challenges of 3D printing harvesters are discussed. Reported applications and strategies to improve the performance of printed harvesting devices are presented.
It is important to minimize the unscheduled downtime of machines caused by outages of machine components in highly automated production lines. Considering machine tools such as, grinding machines, the bearing inside of spindles is one of the most critical components. In the last decade, research has increasingly focused on fault detection of bearings. In addition, the rise of machine learning concepts has also intensified interest in this area. However, up to date, there is no single one-fits-all solution for predictive maintenance of bearings. Most research so far has only looked at individual bearing types at a time.
This paper gives an overview of the most important approaches for bearing-fault analysis in grinding machines. There are two main parts of the analysis presented in this paper. The first part presents the classification of bearing faults, which includes the detection of unhealthy conditions, the position of the error (e.g. at the inner or at the outer ring of the bearing) and the severity, which detects the size of the fault. The second part presents the prediction of remaining useful life, which is important for estimating the productive use of a component before a potential failure, optimizing the replacement costs and minimizing downtime.