Refine
Year of publication
Document Type
- Conference Proceeding (18)
- Article (reviewed) (8)
- Part of a Book (2)
- Contribution to a Periodical (2)
- Report (2)
Conference Type
- Konferenzartikel (17)
- Konferenz-Abstract (1)
Is part of the Bibliography
- yes (32) (remove)
Keywords
- Demand side flexibility (2)
- Digitalization (2)
- Energie (2)
- Energy Flexibility (2)
- Energy Management (2)
- Energy systems modeling (2)
- MPC (2)
- Optimization and control (2)
- Umweltforschung (2)
- heat pump (2)
Institute
- INES - Institut für nachhaltige Energiesysteme (23)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (19)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (11)
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (5)
- CRT - Campus Research & Transfer (2)
- Zentrale Einrichtungen (2)
Open Access
- Closed Access (12)
- Open Access (11)
- Closed (8)
- Bronze (2)
- Diamond (1)
- Gold (1)
Encapsulant-free N.I.C.E. modules have strong ecological advantages compared to conventional laminated modules but suffer generally from lower electrical performance. Via long-term outdoor monitoring of fullsize industrial modules of both types with identical solar cells, we investigated if the performance difference remains constant over time and which parameters influence its value. After assessing about a full year’s data, two obvious levers for N.I.C.E. optimization are identified: The usage of textured glass and transparent adhesives on the module rear side. Also, the performance loss could be alleviated using tracking systems due to lower AOI values. Our measurements show additionally that N.I.C.E. module surfaces are in average about 2.5°C cooler compared to laminated modules. With these findings, we lay out a roadmap to reduce today’s LIV gap of about 5%rel by different optimizations.
In this paper we report on further success of our work to develop a multi-method energy optimization which works with a digital twin concept. The twin concept serves to replicate production processes of different kinds of production companies, including complex energy systems and test market interactions to then use them for model predictive optimizing. The presented work finally reports about the performed flexibility assessment leading to a flexibility audit with a list of measures and the impact of energy optimizations made related to interactions with the local power grid i.e., the exchange node of the low voltage distribution grid. The analysis and continuous exploration of flexibilities as well as the exchange with energy markets require a “guide” leading to continuous optimization with a further tool like the Flexibility Survey and Control Panel helping decision-making processes on the day-ahead horizon for real production plants or the investment planning to improve machinery, staff schedules and production
infrastructure.
Soiling is an important issue in the renewable energy sector since it can result in significant yield losses, especially in regions with higher pollution or dust levels. To mitigate the impact of soiling on photovoltaic (PV) plants, it is essential to regularly monitor and clean the panels, as well as develop accurate soiling predictions that can affect cleaning strategies and enhance the overall performance of PV power plants. This research focuses on the problem of soiling loss in photovoltaic power plants and the potential to improve the accuracy of soiling predictions. The study examines how soiling can affect the efficiency and productivity of the modules and how to measure and predict soiling using machine learning (ML) algorithms. The research includes analyzing real data from large-scale ground-mounted PV sites and comparing different soiling measurement methods. It was observed that there were some deviations in the real soiling loss values compared to the expected values for some projects in southern Spain, thus, the main goal of this work is to develop machine learning models that could predict the soiling more accurately. The developed models have a low mean square error (MSE), indicating the accuracy and suitability of the models to predict the soiling rates. The study also investigates the impact of different cleaning strategies on the performance of PV power plants and provides a powerful application to predict both the soiling and the number of cleaning cycles.
This paper focuses on appropriately measuring the accuracy of forecasts of load behavior and renewable generation in micro-grid operation. Common accuracy measures like the root mean square of the error are often difficult to interpret for system design, as they describe the mean accuracy of the forecast. Micro-grid systems, however, have to be designed to handle also worst case situations. This paper therefore suggests two error measures that are based on the maximum function and that better allow understanding worst case requirements with respect to balancing power and balancing energy supply.
A balcony photovoltaic (PV) system, also known as a micro-PV system, is a small PV system consisting of one or two solar modules with an output of 100–600 Wp and a corresponding inverter that uses standard plugs to feed the renewable energy into the house grid. In the present study we demonstrate the integration of a commercial lithium-ion battery into a commercial micro-PV system. We firstly show simulations over one year with one second time resolution which we use to assess the influence of battery and PV size on self-consumption, self-sufficiency and the annual cost savings. We then develop and operate experimental setups using two different architectures for integrating the battery into the micro-PV system. In the passive hybrid architecture, the battery is in parallel electrical connection to the PV module. In the active hybrid architecture, an additional DC-DC converter is used. Both architectures include measures to avoid maximum power point tracking of the battery by the module inverter. Resulting PV/battery/inverter systems with 300 Wp PV and 555 Wh battery were tested in continuous operation over three days under real solar irradiance conditions. Both architectures were able to maintain stable operation and demonstrate the shift of PV energy from the day into the night. System efficiencies were observed comparable to a reference system without battery. This study therefore demonstrates the feasibility of both active and passive coupling architectures.
Mit dem Klimaschutzgesetz 2021 wurden von der Bundesregierung die Klimaschutzvorgaben verschärft und die Treibhausgasneutralität bis 2045 als Ziel verankert. Zur Erreichung dieses ambitionierten Ziels ist es notwendig, im Bereich der Mobilität weitgehend von Verbrennungsmotoren mit fossilen Kraftstoffen auf Elektromobilität mit regenerativ erzeugtem Strom umzusteigen. Dabei ist die zügige Bereitstellung einer ausreichenden Ladeinfrastruktur für die Elektrofahrzeuge eine große Herausforderung. Neben der Installation einer ausreichend großen Zahl von Ladepunkten selbst besteht die Herausforderung darin, diese in das bestehende Verteilungsnetz zu integrieren bzw. das Verteilungsnetz so auszubauen, dass weiter ein sicherer Netzbetrieb gewährleistet werden kann. Dabei sind insbesondere Lösungen gefragt, bei denen der Ausbau der Ladeinfrastruktur und der Netzbetriebsmittel durch intelligentes Management des Ladens so gering wie möglich gehalten wird, indem vorhandene oder neu zu installierender Hardware möglichst effizient genutzt wird.
Hier setzte das Projekt „Intelligente Ladeinfrastruktur für Elektrofahrzeuge auf dem Parkplatz der Hochschule Offenburg (INTLOG)“ (Projektlaufzeit 15.11.2020 – 30.09.2022) an. Inhalt des Projekts war es, einen Ladepark für den Parkplatz der Hochschule Offenburg mit 20 Ladepunkten à 11 kW und somit einer Gesamtladeleistung von 220 kW an einen vorhandenen Ortsnetztransformator mit 200 kW Nennleistung anzuschließen, der aber bereits von anderen Verbrauchern genutzt wurde. Das übergeordnete Ziel war es also, eine Ladeinfrastruktur von maßgeblichem Umfang in die bestehende Netzinfrastruktur ohne zusätzlichen Ausbau zu integrieren.
Dabei wurden zukunftsweisende Technologien genutzt und weiterentwickelt sowie teilweise in Praxis, im Labor und in der Computersimulation demonstriert.
One of the major challenges impeding the energy transition is the intermittency of solar and wind electricity generation due to their dependency on weather changes. The demand-side energy flexibility contributes considerably to mitigate the energy supply/demand imbalances resulting from external influences such as the weather. As one of the largest electricity consumers, the industrial enterprises present a high demand-side flexibility potential from their production processes and on-site energy assets. In this direction, methods are needed with a focus on enabling the energy flexibility and ensure an active participation of such enterprises in the electricity markets especially with variable prices of electricity. This paper presents a generic model library for an industrial enterprise implemented with optimal control for energy flexibility purposes. The components in the model library represent the typical technical units of an industrial enterprise on material, media, and energy flow levels with their operative constraints. A case study of a plastic manufacturing plant using the generic model library is also presented, in which the results of two simulation with different electricity prices are compared and the behavior of the model can be assessed. The results show that the model provides an optimal scheduling of the manufacturing system according to the variations in the electricity prices, and ensures an optimal control for utilities and energy systems needed for the production.
The conversion of space heating for private households to climate-neutral energy sources is an essential component of the energy transition, as this sector as of 2018 was responsible for 9.4 % of Germany’s carbon dioxide emissions. In addition to reducing demand through better insulation, the use of heat pumps fed with electricity from renewable energy sources, such as on-site photovoltaics (PV) systems, is an important solution approach.
Advanced energy management and control can help to make optimal use of such heating systems. Optimal here can e.g. refer to maximizing self-consumption of self-generated PV power, extended component lifetime or a grid-friendly behavior that avoids load peaks. A powerful method for this is model predictive control (MPC), which calculates optimal schedules for the controllable influence variables based on models of the system dynamics, current measurements of system states and predictions of future external influence parameters.
In this paper, we will discuss three different use cases that show how artificial intelligence can contribute to the realization of such an MPC-based energy management and control system. This will be done using the example of a real inhabited single family home that has provided the necessary data for this purpose and where the methods are implemented and tested. The heating system consists of an air-water heat pump with direct condensation, a thermal stratified storage tank, a pellet burner and a heating rod and provides both heating and hot water. The house generates a significant portion of its electricity needs through a rooftop PV system.