Refine
Year of publication
- 2018 (87) (remove)
Document Type
- Conference Proceeding (33)
- Article (reviewed) (17)
- Article (unreviewed) (12)
- Working Paper (12)
- Letter to Editor (4)
- Report (3)
- Part of a Book (2)
- Contribution to a Periodical (2)
- Periodical Part (2)
Conference Type
- Konferenzartikel (21)
- Konferenz-Abstract (10)
- Sonstiges (2)
Is part of the Bibliography
- yes (87) (remove)
Keywords
- Betriebstypenmarke (3)
- Handelsmarke (3)
- Marke (3)
- RoboCup (3)
- Einzelhandel (2)
- Ganztagsschule (2)
- Markenartikel (2)
- Roboter (2)
- Robotics (2)
- Simulation (2)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (37)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (17)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (17)
- Fakultät Wirtschaft (W) (13)
- INES - Institut für nachhaltige Energiesysteme (7)
- ACI - Affective and Cognitive Institute (4)
- CRT - Campus Research & Transfer (3)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (2)
- Rektorat/Verwaltung (1)
- Zentrale Einrichtungen (1)
Open Access
- Open Access (87) (remove)
In the 19th century Alexander von Humboldt explored the nature and was conceived a new vision of nature that still influences the way we understand the new world. Humboldt believed in the importance of accurate measurements and precise description of observations. His vision of nature included not only facts but also emotions.
Nowadays smart solutions will be developed by using computer technology, which will influence our relationship to nature, our handling of the complexity and diversity of nature itself and the technological influences on the society. Could we avoid a new form of “Colonialism”, when a network of super computers will create a smarter world?
Die Einbindung von Mini- und Mikro-BHKW in ein virtuelles Kleinkraftwerk (VKK) bietet vielfältige wirtschaftliche, Smart-Grids- und Klimaschutzpotentiale zur Unterstützung der "Wärmewende". Eine Einbindung solcher Anlagen ist bisher jedoch mit zumeist hohen Kosten verbunden, weshalb i.d.R. nur Anlagen in höheren Leistungsklassen (> 500 kWel) umgesetzt werden. Im Rahmen des Projekts mikroVKK wurde deshalb das Ziel verfolgt zu demonstriert und nachzuweisen, dass auch BHKW-Anlagen unter 100 kWel in ein virtuelles Kleinkraftwerk (VKK) wirtschaftlich einzubinden sind.
GridSystronic Energy (GSE) hat hierfür ein spezielles VKK-System (gs.system) entwickelt, welches im Rahmen des Projekts unter realen Bedingungen erprobt, weiterentwickelt und möglichst zur Marktreife gebracht wurde. Durch die Konfiguration des Systems - d.h. einfache Steuerboxen (gs.box) werden als Gateway für die Kommunikation vor Ort zur Anlagen- und Zähleranbindung verbaut, wohingegen die Berechnungen, Simulationen und Optimierung der Steuersignale auf dem zentralen gs.server erfolgt - lässt sich eine kostengünstige und skalierbare Lösung darstellen.
Zusammen mit zehn Stadtwerken als Praxispartner wurden unterschiedliche BHKW- Standorte identifiziert und auf deren technische Eignung und die Umsetzbarkeit neuer Geschäftsmodelle auf Basis einer intelligenten Steuerung analysiert. Für ausgewählte Objekte, wie z.B. Schulen, Wärmenetze, Mehrfamiliengebäude, wurde durch GSE eine Anbindung der für die Regelung notwendigen Geräte und Zähler realisiert. Regelwerke, wie z.B. "Lastprofil folgen", als Basis für neue Geschäftsmodelle wurden mit den Praxispartnern abgestimmt und entwickelt. Anhand der Erkenntnisse zu den Effekten der intelligenten Steuerung (z.B. Nutzung von möglichen Flexibilitäten, Stabilität des Systems, Verschiebung der Betriebszeiten, Änderung der Lieferquoten etc.) wurden neue Geschäftsmodelle detailliert analysiert und mit den Praxispartnern prototypisch umgesetzt. Die Evaluation zu den Smart-Grids-Potenzialen (Flexibilität, netzdienliche Einspeisung etc.) sowie die Potenziale zur Unterstützung des Klimaschutzes (CO2-Minderung) erfolgte anhand von gemessenen und simulierten Werten.
Während der Projektlaufzeit konnte die technische Anbindbarkeit von BHKW-Anlagen mit einer elektrischen Leistung bis 100 kWel demonstriert werden. Die Vorarbeiten für die Erarbeitung einer standardisierten und kostengünstigen Anbindungslösung war jedoch sehr viel zeitintensiver als ursprünglich geplant, weshalb die Anlagen verspätet oder z.T. gar nicht angebunden werden konnten. Wegen der geringen Datenbasis konnten die grundsätzlichen wirtschaftlichen Potenziale einer VKK Steuerung deshalb nur auf theoretischer Basis nachgewiesen werden. Die Anbindungs- und Integrationskosten hängen stark von den örtlichen Gegebenheiten ab, weshalb es hierfür keine pauschale Aussage getroffen werden kann. Durch die gewonnenen Erfahrungen und Lernprozesse konnte jedoch im Laufe des Projektes bereits eine erhebliche Kostenreduktion erzielt werden. Auch bei Neuanlagen, bei denen die Anbindung bereits vorab eingeplant werden kann, können die Kosten der Anbindung stark reduziert werden. Die Smart-Grid-Potenziale und die Klimaschutzpotenziale eines VKK-Einsatzes wurden von der Hochschule Offenburg ebenfalls auf einer theoretischen Basis ermittelt. In einem nächsten Schritt wäre es deshalb notwendig zu analysieren, ob sich die ermittelten Effekte auch unter realen Bedingungen einstellen.
The growing demand for active medical implantable devices requires data and or power links between the implant and the outside world. Every implant has to be encapsulated from the body by a specific housing and one of the most common materials used is titanium or titanium alloy. Titanium thas the necessary properties in terms of mechanical and chemical stability and biocompatibility. However, its electrical conductivity presents a challenge for the electromagnetic transmission of data and power. The proposed paper presents a fast and practical method to determine the necessary transmission parameters for titanium encapsulated implants. Therefore, the basic transformer-transmission-model is used with measured or calculated key values for the inductances. Those are then expanded with correction factors to determine the behavior with the encapsulation. The correction factors are extracted from finite element method simulations. These also enable the analysis of the magnetic field distribution inside of the housing. The simulated transmission properties are very close to the measured values. Additionally, based on lumped elements and magnetic field distribution, the influential parameters are discussed in the paper. The parameter discussion describes how to enhance the transmitted power, data-rate or distance, or to reduce the size of the necessary coils. Finally, an example application demonstrates the usage of the methods.
Hintergrund: Richtung und Stärke des elektrischen Feldes (E-Feld) der biventrikulären (BV) Stimulation und elektrische interventrikuläre Desynchronisation sind bei Patienten mit Herzinsuffizienz und verbreitertem QRS Komplex von Bedeutung für den Erfolg der kardialen Resynchronisationstherapie (CRT). Das 3D Herzrhythmusmodell (HRM) ermöglicht die
Simulation von CRT und Hochfrequenz (HF) Ablation. Das Ziel der Studie besteht in der Integration von Schrittmacher- und Ablationselektroden in das HRM zur E-Feld Simulation der BV Stimulation und thermischen Feld (T-Feld) Simulation der HF Ablation von Vorhofflimmern (AF).
Methoden: Es wurden fünf multipolare linksventrikuläre (LV) Elektroden, eine epikardiale LV Elektrode, vier bipolare rechtsatriale (RA) Elektroden, zwei rechtsventrikuläre (RV) Elektroden und ein HF Ablationskatheter mit CST (Computer Simulation Technology, Darmstadt) modelliert und das HRM (Schalk et al: Clin Res Cardiol 106, Suppl 1, April 2017, P1812) um den Koronarvenensinus (CS) erweitert (HRM-CS). E-Feld Simulationen bei vorhofsynchroner BV Stimulation und bei RA Stimulation mit RV und LV Ableitung erfolgten mit den Elektroden Select Secure 3830, Capsure VDD-2 5038 und Attain OTW 4194 im HRM+CS (Fig.). F-Feld Simulationen der HF Ablation von AF bei CRT wurden mit integriertem Ablationskatheter AlCath G FullCircle (Biotronik) simuliert.
Ergebnisse: HRM-CS ermöglichte 3D E-Feld Simulationen bei vorhofsynchroner bipolarer BV Stimulation und bei bipolarer RA Stimulation mit bipolarer RV und LV Ableitung. RV und LV Stimulation erfolgten zeitgleich bei einer Amplitude von 3 V an der LV Elektrode und 1 V an der RV Elektrode mit einer Impulsbreite von jeweils 0,5 ms. Die von der BV Stimulationen erzeugten Fernpotentiale konnten von der RA Elektrode wahrgenommen werden. Das Fernpotential an der RA Elektrodenspitze betrug 32,86 mV und in 1 mm Abstand von der RA Elektrodenspitze ergab sich ein Fernpotential von 185,97 mV. HRM-CS ermöglichte 3D T-Feld Simulationen der HF Ablation von AF bei CRT. Das T-Feld bei HF Ablation des AV-Knotens wurde mit einer anliegenden Leistung von 5 W bei 420 kHz an der distalen 8 mm Ablationselektrode simuliert. Die Temperatur an der Katheterspitze betrug nach 5 s Ablationsdauer 88,66 °C, in 1 mm Abstand von der Katheterspitze im Myokard 42,17 °C und in 2 mm Abstand 37,49 °C.
Schlussfolgerungen: HRM-CS und Elektrodenmodelle ermöglichen die 3D Simulationen von E-Feldern bei vorhofsynchroner BV Stimulation, RA Stimulation mit RV und LV Wahrnehmung und von T-Feldern bei HF Ablation. E-Feld Simulationen von RA, RV und LV Stimulation und Sensing können möglicherweise zur Vorhersage von CRT Respondern genutzt werden.
Die Erstellung und der Einsatz digitaler Medien basieren häufig auf der Annahme eines idealtypischen Lernprozesses, welcher die effektive Erarbeitung von Inhalten unter Berücksichtigung individueller Vorkenntnisse und Lebensumstände ermöglicht. Erfahrungen Lehrender legen jedoch die Vermutung nahe, dass Studierende selten ein idealtypisches Lernverhalten an den Tag legen. Für den Beitrag „Nutzungsmuster bei digitalen Medien“ wurden Forschungsarbeiten zu digitalen instruktionalen Medien gezielt ausgewertet, um die tatsächlichen Verhaltensweisen beim Lernen und die hiermit verbundenen Wirkungen aufzuzeigen. Aufbauend auf den Erkenntnissen soll eine Diskussion um mögliche Folgerungen für die Lehre angeregt werden.