Refine
Year of publication
- 2012 (30) (remove)
Document Type
Conference Type
- Konferenzartikel (30) (remove)
Is part of the Bibliography
- yes (30) (remove)
Keywords
- 2D-TLC (1)
- Aircraft (1)
- Attenuation (1)
- BLE (1)
- Batterie (1)
- Brennstoffzelle (1)
- Bruchmechanik (1)
- Collaborative learning (1)
- Communication networks (1)
- Couplings (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (19)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (7)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (3)
- CRT - Campus Research & Transfer (2)
- WLRI - Work-Life Robotics Institute (2)
- Fakultät Wirtschaft (W) (1)
- INES - Institut für nachhaltige Energiesysteme (1)
Open Access
- Closed (10)
- Closed Access (10)
- Open Access (9)
- Bronze (2)
In this paper, a complete passive transponder device has been discussed which is meant to monitor leakage in silicone breast implants. The passive tag operates in the HF frequency range of 13.56MHz using RFID ISO 15693 standard. The complete system consists of the transponder, reader and a PC. This paper focusses on the development of such a state of the art passive RFID transponder to monitor the wellness of the silicone breast implants periodically in order to detect leakage in the same. Keyword: RFID (Radio frequency identification device), EM (Electromagnetic) field, Passive Transponder, Silicone breast implants.
The paper focuses on a numerical model which describes the radial temperature evolution in an optical fiber during the heating and cooling process according to the SP1 approximation. Based on this model, experimental methods for temperature measurement with optical fibers and for splice process optimization can be developed.
Die hohen Anforderungen vor allem an Drehmoment übertragende und mehrfachgekerbte Profilwellen im konstruktiven Umfeld moderner Maschinen zwingen uns, der Frage der Kerbwirkungen sowie Maßnahmen zu deren Milderung erhöhte Aufmerksamkeit zu widmen. Während die Kerbwirkung der geometrischen Einzelkerben bereits recht eingehend erforscht ist, liegen wesentlich komplexere Verhältnisse bei Mehrfachkerben vor, die durch die gegenseitige Beeinflussung mehrerer benachbarter Kerben entstehen. Der hier vorliegende Beitrag beschreibt erste Untersuchungsergebnisse mit der Finite-Elemente-Methode (FEM) zur gegenseitigen Wechselwirkung zweier Kerbformen "Sicherungsringnut und Zahnfußrundung" bei Zahnwellen mit Evolventenflanken nach DIN 5480. Diese Kerbkombination tritt in der Praxis häufig auf. Entsprechende Formzahldiagramme und Gestaltungshinweise werden angegeben und Näherungsformeln für die genauere Formzahlbestimmung je nach Belastungsart aufgestellt.
This paper analyzes the applicability of existing communication technology on the Smart Grid. In particular it evaluates how networks, e.g. Peer-to-Peer (P2P) and decentralized Virtual Private Network (VPN) can help set up an agent-based system. It is expected that applications on Smart Grid devices will become more powerful and be able to operate without a central control instance. We analyze which requirements agents and Smart Grid devices place on communication systems and validate promising approaches. The main focus is to create a logical overlay network that provides direct communication between network nodes. We provide a comparison of different approaches of P2P networks and mesh-VPNs. Finally the advantages of mesh-VPN for agent-based systems are worked out.
Cardiac resynchronization therapy (CRT) with biventricular (BV) pacing is an established therapy in approximately two-thirds of symptomatic heart failure (HF) patients (P) with left bundle branch block (LBBB). The aim of this study was to evaluate left atrial (LA) conduction delay (LACD) and left ventricular (LV) conduction delay (LVCD) using pre-implantational transesophageal electrocardiography (ECG) in sinus rhythm (SR) CRT responder (R) and non-responder (NR).
Methods: SR HF P (n=52, age 63.6±10.4 years; 6 females, 46 males) with New York Heart Association (NYHA) class 3.0±0.2, 24.4±7.1 % LV ejection fraction and 171.2±37.6 ms QRS duration (QRSD) were measured by bipolar filtered transesophageal LA and LV ECG recording with hemispherical electrodes (HE) TO catheter (Osypka AG, Rheinfelden, Germany). LACD was measured between onset of P-wave in the surface ECG and onset of LA deflection in the LA ECG. LVCD was measured between onset of QRS in the surface ECG and onset of LV deflection in the LV ECG.
Results: There were 78.8 % SR CRT R (n=41) with 171.2±36.9 ms QRSD, 73.3±25.7 ms LACD, 80.0±24.0 ms LVCD and 2.3±0.5 QRSD-LVCD-ratio. SR CRT R QRSD correlated with LACD (r=0.688, P<0.001) and LVCD (r=0.699, P<0.001). There were 21.2 % SR CRT NR (n=11) with 153.4±22.4 ms QRSD (P=0.133), 69.8±24.8 ms LACD (n=6, P=0.767), 54.2±31.0 ms LVCD (P<0.0046) and 3.9±2.5 QRSD-LVCD-ratio (P<0.001). SR CRT NR QRSD not corre-lated with IACD (r=-0.218, P=0.678) and IVCD (r=0.042, P=0.903). During a 22.8±21.3 month CRT follow-up, the CRT R NYHA class improved from 3.1±0.3 to 1.9±0.3 (P<0.001). In CRT NR, NYHA class not improved (2.9±0.4 to 2.9±0.2, P=1) during 11.2±9.8 months BV pacing.
Conclusions: Transesophageal LA and LV ECG with HE can be utilized to analyse LACD and LVCD in HF P. Pre-implantational LVCD and QRSD-LVCD-ratio may be additional useful parameters to improve P selection for SR CRT.
Capture threshold (CT) for transesophageal left atrial (LA) pacing (TLAP) and transesophageal left ventricular (LV) pacing (TLVP) with conventional cylindrical electrodes (CE) are higher than TLAP feeling threshold (FT). Purpose of the study was to evaluate focused TLAP CT and FT for supraventricular tachycardia (SVT) initiation and focused TLVP CT for cardiac resynchronisation therapy (CRT) simulation.
Methods: SVT initiation in patients (P) with palpitations (n=49, age 47 ± 17 years) was analysed during spontaneous rhythm and during focused bipolar TLAP with atrial constant current stimulus output, distal CE and three or seven 6 mm hemispherical electrodes (HE) (TO, Osypka AG, Rheinfelden, Germany). CRT simulation in heart failure P (n=75, age 62 ± 11 years) was evaluated by focused bipolar TLAP and/or TLVP with ventricular constant voltage stimulus output and different pacing mode.
Results: Focused electrical pacing field between CE and HE (n=28) allowed low threshold TLAP with 8.0 ± 2.6 mA CT at 9.9 ms stimulus duration (SD) which was lower than 9.2 ± 4.5 mA FT at 9.9 ms SD. Focused electrical pacing field between HE and HE (n=21) allowed low threshold TLAP with 8.1 ± 2.2 mA CT at 9.9 ms SD which was lower than 9.8 ± 5.0 mA FT at 9.9 ms SD. SVT initiation by programmed AAI TLAP was possible in 23 P and not possible in 26 P. CRT simulation was evaluated with TLAP and TLVP with VAT, D00 and V00 pacing mode and 95.5 ± 10.9 V TLVP CT at 4.0 ms SD.
Conclusions: Programmed focused AAI TLAP allowed initiation of SVT with very low CT and high FT and focused electrical pacing field between CE-HE and HE-HE.CRT simulation with focused TLAP and/or TLVP with VAT, D00 and V00 pacing mode may be a useful technique to detect responders to CRT.