Refine
Year of publication
- 2018 (41) (remove)
Document Type
- Article (reviewed) (41) (remove)
Is part of the Bibliography
- yes (41) (remove)
Keywords
- Mikrostruktur (2)
- Plastizität (2)
- cardiac resynchronization therapy (2)
- 3D modeling (1)
- 3d Heart Simulation (1)
- Aging (1)
- Alexander von Humboldt (1)
- Astaxanthin (1)
- Canthaxanthin (1)
- Catheter Ablation (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (18)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (12)
- Fakultät Wirtschaft (W) (5)
- INES - Institut für nachhaltige Energiesysteme (5)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (3)
- CRT - Campus Research & Transfer (2)
- ACI - Affective and Cognitive Institute (1)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (1)
Open Access
- Closed Access (19)
- Open Access (17)
- Diamond (1)
- Gold (1)
Die Hersteller von Cochlea-Implantat (CI)-Systemen sehen für klinische Audiologen die Möglichkeit vor, die Mikrofonleistung der meisten aktuellen CI-Sprachprozessoren mittels anschließbarer Monitorkopfhörer zu prüfen. Nähere Angaben dazu, nach welchem Prozedere diese Prüfung stattfinden soll, z. B. welche Stimuli mit welchen Pegeln verwendet werden sollen, sind nach Wissen der Autoren seitens der CI-Hersteller nicht verfügbar. Auf der Basis dieser subjektiven Prüfung entscheidet dann der Audiologe, ob der betreffende Sprachprozessor an den Hersteller eingeschickt wird oder nicht. Wir haben eine Messbox entwickelt, mit der die Mikrofonleistung aller abhörbaren CI-Sprachprozessoren der Hersteller Advanced Bionics, Cochlear und MED-EL objektiv geprüft werden kann. Die Box wurde im 3-D-Druckverfahren hergestellt. Der zu prüfende Sprachprozessor wird in die Messbox eingehängt und über einen verbauten Lautsprecher mit definierten Prüfsignalen (Sinustönen unterschiedlicher Frequenz) beschallt. Das Signal des Mikronfons bzw. der Mikrofone wird über das in der Audio-/Abhörbuchse des Prozessors eingesteckte Kabel der Monitorkopfhörer herausgeführt und mit einer Shifting and Scaling-Schaltung in einen Spannungsbereich transformiert, der für die A/D-Wandlung mit einem Mikrokontroller (ATmega1280 verbaut auf einem Arduino Mega) geeignet ist. Derselbe Mikrokontroller übernimmt über einen eigens gebauten D/AWandler die Ausgabe der Prüfsignale über den Lautsprecher. Signalaufnahme und –wiedergabe erfolgt jeweils mit einer Samplingrate von 38,5 kHz. Der frequenzspezifische Effektivwert des abgegriffenen Mikrofonsignals wird mit einem Referenzwert verglichen. Die (frequenzspezifischen) Referenzwerte wurden mit einem neuwertigen Sprachprozessor gleichen Typs ermittelt und im Speicher des Mikrokontrollers abgelegt. Das Ergebnis wird nach Abschluss der Messung grafisch auf einem Touchscreen ausgegeben. Derzeit läuft eine erste Datenerhebung mit in der Klinik subjektiv auffällig gewordenen CI-Sprachprozessoren, die anschließend in der Messbox untersucht werden. Längerfristiges Ziel ist es, die hit und false alarm Raten der subjektiven Prüfung zu ermitteln.
The authors claim that location information of stationary ICT components can never be unclassified. They describe how swarm-mapping crowd sourcing is used by Apple and Google to worldwide harvest geo-location information on wireless access points and mobile telecommunication systems' base stations to build up gigantic databases with very exclusive access rights. After having highlighted the known technical facts, in the speculative part of this article, the authors argue how this may impact cyber deterrence strategies of states and alliances understanding the cyberspace as another domain of geostrategic relevance. The states and alliances spectrum of activities due to the potential existence of such databases may range from geopolitical negotiations by institutions understanding international affairs as their core business, mitigation approaches at a technical level, over means of cyber deterrence-by-retaliation.
In this article, we present a taxonomy in Robot-Assisted Training; a growing body of research in Human–Robot Interaction which focuses on how robotic agents and devices can be used to enhance user’s performance during a cognitive or physical training task. Robot-Assisted Training systems have been successfully deployed to enhance the effects of a training session in various contexts, i.e., rehabilitation systems, educational environments, vocational settings, etc. The proposed taxonomy suggests a set of categories and parameters that can be used to characterize such systems, considering the current research trends and needs for the design, development and evaluation of Robot-Assisted Training systems. To this end, we review recent works and applications in Robot-Assisted Training systems, as well as related taxonomies in Human–Robot Interaction. The goal is to identify and discuss open challenges, highlighting the different aspects of a Robot-Assisted Training system, considering both robot perception and behavior control.
The production of potable water in dry areas nowadays is mainly done by the desalination of seawater. State of the art desalination plants usually are built with high production capacities and consume a lot of electrical energy or energy from primary resources such as oil. This causes difficulties in rural areas, where no infrastructure is available neither for the plants’ energy supply nor the distribution of the produced potable water. To address this need, small, self-sustaining and locally operated desalination plants came into the focus of research. In this work, a novel flash evaporator design is proposed which can be driven either by solar power or by low temperature waste heat. It offers low operation costs as well as easy maintenance. The results of an experimental setup operated with water at a feed flow rate of up to 1,600 l/h are presented. It is shown that the proof of concept regarding efficient evaporation as well as efficient gas-liquid separation is provided successfully. The experimental evaporation yield counts for 98 % of the vapor content that is expected from the vapor pressure curve of water. Neither measurements of the electrical conductivity of the gained condensate, nor the analysis of the vapor flow by optical methods show significant droplet entrainment, so there are no concerns regarding the purity of the produced condensate for the use as drinking water.
Techno-economic comparison of membrane distillation and MVC in a zero liquid discharge application
(2018)
Membrane distillation (MD) is a thermally driven membrane process for the separation of vapour from a liquid stream through a hydrophobic, microporous membrane. However, a commercial breakthrough on a large scale has not been achieved so far. Specific developments on MD technology are required to adapt the technology for applications in which its properties can potentially outshine state of the art technologies such as standard evaporation. In order to drive these developments in a focused manner, firstly it must be shown that MD can be economically attractive in comparison to state of the art systems. Thus, this work presents a technological design and economic analysis for AGMD and v-AGMD for application in a zero liquid discharge (ZLD) process chain and compares it to the costs of mechanical vapour compression (MVC) for the same application. The results show that MD can potentially be ~40% more cost effective than MVC for a system capacity of 100 m3/day feed water, and up to ~75% more cost effective if the MD is driven with free waste heat.
Membrane distillation (MD) is a thermal separation process which possesses a hydrophobic, microporous
membrane as vapor space. A high potential application for MD is the concentration of hypersaline brines, such as
e.g. reverse osmosis retentate or other saline effluents to be concentrated to a near saturation level with a Zero
Liquid Discharge process chain. In order to further commercialize MD for these target applications, adapted MD
module designs are required along with strategies for the mitigation of membrane wetting phenomena. This
work presents the experimental results of pilot operation with an adapted Air Gap Membrane Distillation
(AGMD) module for hypersaline brine concentration within a range of 0–240 g NaCl /kg solution. Key performance
indicators such as flux, GOR and thermal efficiency are analyzed. A new strategy for wetting mitigation
by active draining of the air gap channel by low pressure air blowing is tested and analyzed. Only small reductions
in flux and GOR of 1.2% and 4.1% respectively, are caused by air sparging into the air gap channel.
Wetting phenomena are significantly reduced by avoiding stagnant distillate in the air gap making the air blower
a seemingly worth- while additional system component.
Cardiac contractility modulation (CCM) is a device-based therapy for the treatment of systolic left ventricular chronic heart failure. Unlike other device-based therapies for heart failure, CCM delivers non-excitatory pacing signals to the myocardium. This leads to an extension of the action potential and to an improved contractility of the heart. The modeling and simulation was done with the electromagnetic simulation software CST. Three CCM electrodes were inserted into the Offenburg heart rhythm model and subsequently simulated the electric field propagation in CCM therapy.
In addition, simulations of CCM have been performed with electrodes from other device-based therapies, such as cardiac resynchronization therapy (CRT) and implantable cardioverter / defibrillator (ICD) therapy. At the same distance to the simulation electrode, the electric field is slightly stronger in CCM therapy than in CCM therapy with additionally implanted CRT or ICD electrodes. In addition, there is a change in the electric field propagation at the electrodes of the CRT and the shock electrode of the ICD.
By simulating several different therapy procedures on the heart, it is possible to check how they affect their behavior during normal operation. CCM heart rhythm model simulation allows the evaluation the individual electrical pacing and sensing field during CCM.