Refine
Year of publication
- 2015 (22) (remove)
Document Type
- Conference Proceeding (13)
- Article (reviewed) (5)
- Patent (2)
- Article (unreviewed) (2)
Conference Type
- Konferenzartikel (10)
- Konferenz-Abstract (2)
- Sonstiges (1)
Is part of the Bibliography
- yes (22) (remove)
Keywords
- Physik (2)
- Abtragung (1)
- Applikation (1)
- Automotive engineering (1)
- Biomedizin (1)
- Boiler (1)
- Eingebettetes System (1)
- Elektrokardiografie (1)
- Embedded Software (1)
- Energieversorgung (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (22) (remove)
Open Access
- Open Access (22) (remove)
In this paper an RFID/NFC (ISO 15693 standard) based inductively powered passive SoC (system on chip) for biomedical applications is presented. A brief overview of the system design, layout techniques and verification method is dis-cussed here. The SoC includes an integrated 32 bit microcontroller, sensor interface circuit, analog to digital converter, integrated RAM, ROM and some other peripherals required for the complete passive operation. The entire chip is realized in CMOS 0.18 μm technology with a chip area of 1.52mm x 3.24 mm.
The invention concerns a method for spectrum monitoring a given frequency band, in which the spectral power density (S(f)) within the given frequency band is determined for all noise and signal components in the frequency band and, in order to detect the presence of one or more signals within the given frequency band, it is evaluated whether the spectral power density (S(f)) exceeds a threshold value (&lgr;). According to the invention, the threshold value (&lgr;) is calculated in accordance with an estimation of a distribution density (hR(S)) for the noise component of the spectral power density (S(f)) within the given frequency band and in accordance with a predefined value for the false-alarm probability (Pfa).
Der Studienbeginn wird an der Hochschule Offenburg durch Vorbereitungskurse, sogenannte Brückenkurse, unterstützt. Wir stellen vorläufige Ergebnisse beim Einsatz von Smartphones und Tablets im Rahmen des Physik-Brückenkurses vor, bei dem die Studenten Hilfen zum selbständigen Üben durch eine App erhalten. Durch die Überarbeitung des Kurses und den Einsatz der App konnte der Teilnehmerschwund verringert werden. Die Evaluationsergebnisse bestätigen eine hohe Akzeptanz der Neuerungen seitens der Studierenden. Erste Auswertungen von Ein- und Ausgangstests deuten darauf hin, dass durch den Brückenkurs eine Angleichung der Vorkenntnisse der Studienanfänger erreicht wird, da Teilnehmer mit geringeren Vorkenntnissen tendenziell einen größeren Lernfortschritt erreichen. Durch unterschiedliche Schwierigkeitsstufen und selbstregulierte Übungsphasen in individuellem Tempo können aber auch die Erfordernisse der stärkeren Teilnehmer angemessen berücksichtigt werden.
The aim of this research work was to develop a boiler model with few parameters required for energy planning. The showcase considered for this work was the boiler system of the energy center at Offenburg University of Applied Sciences. A grey box model of the boiler was developed systematically starting from model abstraction, simplification, model break-down and to the use of empirical correlations wherever necessary to describe the intermediate effects along with the use of information from manufacturer’s specification in order to reduce parameters. This strategy had resulted in a boiler model with only 6 parameters, namely, nominal burner capacity, water gallery capacity, air ratio, heat capacity of wall, thermal conductance on flue gas and hot water side. Most of these parameters can be obtained through the information available in the spec sheets and thus an energy planner will be able to parameterize the model with low effort. The model was validated with the monitored data of the showcase. It was tested for the start-up, shut-down behavior and the effect of storage.
Cardiac resynchronization therapy with atrioventricular and interventricular delay optimized biventricular pacing is an established therapy for symptomatic heart failure patients with prolongation of QRS duration, left bundle branch block and reduced left ventricular ejection fraction. The aim of the investigation was to evaluate right atrial, right ventricular and left ventricular electrical signals of implantable electronic cardiac devices with and without signal averaging technique with novel LabVIEW software. Electrical interatrial conduction delay and inter-ventricular conduction delay may be useful parameters to evaluate electrical atrial and ventricular desynchronization in heart failure patients.
In der Wertanalyse ist die Methodik TRIZ (Theorie der Lösung erfinderischer Problemstellungen) seit vielen Jahren als Werkzeug zur Kostensenkung oder zur Steigerung der Funktionalität von Produkten bekannt. Seit ihrem ersten Bekanntwerden in Westeuropa hat sich auch TRIZ weiterentwickelt. So wurden Methoden zur Modellierung von Systemen inzwischen erweitert und um Werkzeuge zur schnellen Lösungsfindung, zur Fehlervoraussage und zur Produktplanung neu entwickelt. Durch den weltweiten wissenschaftlichen Fortschritt, die Verwendung unterschiedlicher Sprachen und neue Literatur ist andererseits auch die verwendete Terminologie angewachsen und nicht mehr eindeutig. Die neue VDI-Richtlinie 4521, von deren erstem Teil nun der Gründruck vorliegt, zielt deswegen auf eine Standardisierung der Terminologie und eine vereinheitlichte Beschreibung der Methoden ab. Mit ihrer Hilfe sollen das Studium der Methodik erleichtert, die Benutzung von Literatur vereinfacht und Inhalte der TRIZ klarer darstellbar werden.
The Metering Bus, also known as M-Bus, is a European standard EN13757-3 for reading out metering devices, like electricity, water, gas, or heat meters. Although real-life M-Bus networks can reach a significant size and complexity, only very simple protocol analyzers are available to observe and maintain such networks. In order to provide developers and installers with the ability to analyze the real bus signals easily, a web-based monitoring tool for the M-Bus has been designed and implemented. Combined with a physical bus interface it allows for measuring and recording the bus signals. For this at first a circuit has been developed, which transforms the voltage and current-modulated M-Bus signals to a voltage signal that can be read by a standard ADC and processed by an MCU. The bus signals and packets are displayed using a web server, which analyzes and classifies the frame fragments. As an additional feature an oscilloscope functionality is included in order to visualize the physical signal on the bus. This paper describes the development of the read-out circuit for the Wired M-Bus and the data recovery.