Refine
Year of publication
Document Type
- Conference Proceeding (401) (remove)
Conference Type
- Konferenzartikel (252)
- Konferenz-Abstract (101)
- Sonstiges (30)
- Konferenz-Poster (17)
- Konferenzband (5)
Language
- English (305)
- German (95)
- Multiple languages (1)
Has Fulltext
- no (401) (remove)
Is part of the Bibliography
- yes (401) (remove)
Keywords
- RoboCup (32)
- injury (9)
- Machine Learning (8)
- Ausbildung (6)
- Biomechanik (6)
- Herzkrankheit (5)
- Konstruktion (5)
- biomechanics (5)
- running (5)
- ACL (4)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (131)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (115)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (65)
- Fakultät Wirtschaft (W) (46)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (41)
- IMLA - Institute for Machine Learning and Analytics (28)
- INES - Institut für nachhaltige Energiesysteme (16)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (11)
- Fakultät Medien (M) (ab 22.04.2021) (9)
- ACI - Affective and Cognitive Institute (6)
Open Access
- Open Access (401) (remove)
Die drei großen Hersteller von Cochlea-Implantat (CI)-Systemen ermöglichen es klinischen Audiologen, die Mikrofoneigenschaften der meisten CI-Sprachprozessoren zu prüfen. Dazu können bei diesen Sprachprozessoren Monitorkopfhörer angeschlossen und das/die Mikrofon(e) inklusive eines Teils der Signalvorverarbeitung abgehört werden. Präzise Angaben dazu, mit welchen Stimuli, bei welchem Pegel und nach welchem Kriterium diese Prüfung stattfinden soll, machen die CI-Hersteller nicht. Auf Basis dieser Prüfung soll der Audiologe dann über die Funktion der Mikrofone und damit darüber entscheiden, ob der betreffende Sprachprozessor an den Hersteller eingeschickt wird oder nicht.
Zur Objektivierung der CI-Sprachprozessor-Mikrofon-Prüfung haben wir eine Testbox entwickelt, mit der alle abhörbaren aktuellen CI-Sprachprozessoren der drei großen Hersteller geprüft werden können. Die Box wurde im 3D-Druck-Verfahren hergestellt. Der zu prüfende Sprachprozessor wird in die Messbox eingehängt und über einen darin verbauten Lautsprecher mit definierten Prüfsignalen (Sinustöne unterschiedlicher Frequenz) beschallt. Das Mikrofonsignal wird über das Kabel der Monitorkopfhörer herausgeführt und mit einer Shifting- and Scaling-Schaltung in einen Spannungsbereich transformiert, der für die AD-Wandlung mit einem Mikrokontroller (ATmega1280 verbaut auf einem Arduino Mega) geeignet ist. Derselbe Mikrokontroller übernimmt über einen eigens gebauten DA-Wandler die Ausgabe der Sinustöne über den Lautsprecher. Signalaufnahme und –wiedergabe erfolgen mit jeweils 38,5 kHz Samplingrate. Der für jede Frequenz über mehrere Perioden des Prüfsignals ermittelte Effektivwert wird mit dem Effektivwert, der mit einem neuwertigen Referenzprozessor für diese Frequenz gemessen wurde, verglichen. Die Messergebnisse werden graphisch auf einem Display ausgegeben.
Derzeit läuft eine erste Datenerhebung mit in der Klinik subjektiv auffällig gewordenen CI-Sprachprozessoren, die anschließend in der Messbox untersucht werden. So sollen realistische Schwellen für kritische Abweichungen von den Referenz-Effektivwerten ermittelt werden. Im weiteren Verlauf sollen dann Hit und False Alarm-Raten der subjektiven Prüfung bestimmt werden.
In bimodal cochlear implant (CI) / hearing aid (HA) users a constant interaural time delay in the order of several milliseconds occurs due to differences in signal processing of the devices. For MED-EL CI systems in combination with different HA types, we have quantified the respective device delay mismatch (Zirn et al. 2015). In the current study, we investigate the effect of the device delay mismatch in simulated and actual bimodal listeners on sound localization accuracy.
To deal with the device delay mismatch in actual bimodal listeners we delayed the CI stimulation according to the measured HA processing delay and two other values. With all delay values highly significant improvements of the rms error in the localization task were observed compared to the test without the delay. The results help to narrow down the optimal patient-specific delay value.
Zeitliche Anpassung führt zu verbesserter Schalllokalisation bei bimodal versorgten CI-/HG-Trägern
(2021)
Bei bimodal versorgten Cochlea-Implantaten (CI) / Hörgerät (HG)-Trägern entsteht durch die unterschiedliche Signalverarbeitung der Geräte eine konstante interaurale Zeitverzögerung in der Größenordnung von mehreren Millisekunden. Für MED-EL CI-Systeme in Kombination mit verschiedenen HG-Typen haben wir den jeweiligen Device-Delay-Mismatch quantifiziert. In der aktuellen Studie untersuchen wir den Einfluss der Device-Delay-Mismatch bei simulierten und tatsächlichen bimodalen Hörern auf die Genauigkeit der Schalllokalisation.
Um den Device-Delay-Mismatch bei bimodal versorgten Patienten zu verringern, haben wir die CI-Stimulation um die gemessene HG-Signallaufzeit und zwei weitere Werte verzögert. Nach einer Angewöhnungsphase war der effektive Winkelfehler bei Verzögerung um die HG-Signallaufzeit hochsignifikant reduziert im Vergleich zu der Testkondition ohne CI-Verzögerung (mittlere Verbesserung: 11 % ; p < .01, Wilcoxon Signed Rank Test). Aber auch mit den beiden weiteren Verzögerungswerten wurden Verbesserungen erreicht. Anhand der Ergebnisse lässt sich der optimale patientenspezifische Verzögerungswert näher eingrenzen.
The ability to detect a target signal masked by noise is improved in normal-hearing listeners when interaural phase differences (IPDs) between the ear signals exist either in the masker or in the signal. To improve binaural hearing in bilaterally implanted cochlear implant (BiCI) users, a coding strategy providing the best possible access to IPDs is highly desirable. Outcomes of a previous study (Zirn, Arndt et al. 2016) revealed that a subset of BiCI users showed improved IPD detection thresholds with the fine structure processing strategy FS4 compared to the constant rate strategy HDCIS using narrowband stimuli. In contrast, little differences between the coding strategies were found for broadband stimuli with regard to binaural speech intelligibility level differences (BILD) as an estimate of binaural unmasking. Compared to normalhearing listeners (7.5 ± 1.2 dB) BILD were small in BiCI users (around 0.5 dB with both coding strategies).
In the present work, we investigated the influence of binaural fitting parameters on BILD. In our cohort of BiCI users many were implanted with electrode arrays differing in length left versus right. Because this length difference typically corresponded to the distance of two electrode contacts the first modification of bilateral fitting was a tonotopic adjustment by deactivation of the most apical electrode contact on the side with the deeper inserted array (tonotopic approach).
The second modification was the isolation of the residual, most apical electrode contacts by deactivation of the basally adjacent electrode contact on each side (tonotopic sparse approach). Applying these modifications, BILD improved by up to 1.5 dB.
The ability to detect a signal masked by noise is improved in normal-hearing (NH) listeners when interaural phase differences (IPD) between the ear signals exist either in the masker or the signal. We determined the impact of different coding strategies in bilaterally implanted cochlear implant (BiCI) users with and without fine-structure coding (FSC) on masking level differences. First, binaural intelligibility level differences (BILD) were determined in NH listeners and BiCI users using their clinical speech processors. NH subjects (n=8) showed a significant mean BILD of 7.5 dB. In contrast, BiCI users (n=9) without FSC as well as with FSC revealed a barely significant mean BILD (0.4 dB respectively 0.6 dB). Second, IPD thresholds were measured in BiCI users using either their speech processors with FS4 or direct stimulation with FSC. With the latter approach, synchronized stimulation providing an interaural accuracy of stimulation timing of 1.67 µs was realized on pitch matched electrode pairs. The resulting individual IPD threshold was lower in most of the subjects with direct stimulation than with their speech processors. These outcomes indicate that some BiCI users can benefit from increased temporal precision of interaural FSC and adjusted interaural frequency-place mapping presumably resulting in improved BILD.
Das normalhörende auditorische System ist in der Lage, interaurale Zeit- bzw. Phasendifferenzen zur verbesserten Signaldetektion im Störgeräusch zu nutzen. Dieses Phänomen wird häufig als binaurale Entmaskierung bezeichnet und ist sowohl bei einfachen Signalen wie Sinustönen, als auch bei Sprachsignalen im Störgeräusch wirksam. Vorangegangene Studien haben gezeigt, dass binaurale Entmaskierung eingeschränkt auch bei bilateralen CI-Trägern beobachtbar ist (Zirn et al., 2016).
Aktuelle Ergebnisse zeigen, dass die binaurale Entmaskierung sensitiv gegenüber der bilateralen CI-Anpassung ist. So lässt sich der Effekt durch tonotopen Abgleich und Herausstellen eines apikalen Feinstrukturkanals modulieren. Steigerungen der binauralen Entmaskierung um bis zu 1,5 dB sind auf diese Weise gegenüber der konventionellen CI-Anpassung möglich. Allerdings variiert der Einfluss der CI-Anpassung interindividuell erheblich.
BiCI users’ sensitivity to interaural phase differences for single- and multi-channel stimulation
(2016)
The main advantage of mobile context-aware applications is to provide effective and tailored services by considering the environmental context, such as location, time, nearby objects and other data, and adapting their functionality according to the changing situations in the context information without explicit user interaction. The idea behind Location-Based Services (LBS) and Object-Based Services (OBS) is to offer fully-customizable services for user needs according to the location or the objects in a mobile user's vicinity. However, developing mobile context-aware software applications is considered as one of the most challenging application domains due to the built-in sensors as part of a mobile device. Visual Programming Languages (VPL) and hybrid visual programming languages are considered to be innovative approaches to address the inherent complexity of developing programs. The key contribution of our new development approach for location and object-based mobile applications is a use case driven development approach based on use case templates and visual code templates to enable even programming beginners to create context-aware mobile applications. An example of the use of the development approach is presented and open research challenges and perspectives for further development of our approach are formulated.
Sensors and actuators enable creation of context-aware applications in which applications can discover and take advantage of contextual information, such as user location, nearby people and objects. In this work, we use a general context definition, which can be applied to various devices, e.g., robots and mobile devices. Developing context-based software applications is considered as one of the most challenging application domains due to the sensors and actuators as part of a device. We introduce a new development approach for context-based applications by using use-case descriptions and Visual Programming Languages (VPL). The introduction of web-based VPLs, such as Scratch and Snap, has reinvigorated the usefulness of VPLs. We provide an in-depth discussion of our new VPL based method, a step by step development process to enable development of context-based applications. Two case studies illustrate how to apply our approach to different problem domains: Context-based mobile apps and context-based humanoid robot applications.
The aim of the smart grid is to achieve more efficient, distributed and secure supply of energy over the traditional power grid by using a bidirectional information flow between the grid agents (e.g. generator node, customer). One of the key optimization problems in smart grid is to produce power among generator nodes with a minimum cost while meeting the customer demand, known as Economic Dispatch Problem (EDP). In recent years, many distributed approaches to solve EDP have been proposed. However, protecting the privacy-sensitive data of individual generator nodes has been largely overlooked in the existing solutions. In this work, we show an attack against an existing auction-based EDP protocol considering a non-colluding semi-honest adversary. We briefly introduce our approach to a practical privacy-preserving EDP solution as our work in progress.