Cooling towers or recoolers are one of the major consumers of electricity in a HVAC plant. The implementation and analysis of advanced control methods in a practical application and its comparison with conventional controllers is necessary to establish a framework for their feasibility especially in the field of decentralised energy systems. A standard industrial controller, a PID and a model based controller were developed and tested in an experimental set-up using market-ready components. The characteristics of these controllers such as settling time, control difference, and frequency of control actions are compared based on the monitoring data. Modern controllers demonstrated clear advantages in terms of energy savings and higher accuracy and a model based controller was easier to set-up than a PID.
The variable refrigerant flow system is one of the best heating, ventilation, and air conditioning systems (HVAC) thanks to its ability to provide thermal comfort inside buildings. But, at the same time, these systems are considered one of the most energy-consuming systems in the building sector. Thus, it is crucial to well size the system according to the building’s cooling and heating needs and the indoor temperature fluctuations. Although many researchers have studied the optimization of the building energy performance considering heating or cooling needs, using air handling units, radiant floor heating, and direct expansion valves, few studies have considered the use of multi-objective optimization using only the thermostat setpoints of VRF systems for both cooling and heating needs. Thus, the main aim of this study is to conduct a sensitivity analysis and a multi-objective optimization strategy for a residential building containing a variable refrigerant flow system, to evaluate the effect of the building performance on energy consumption and improve the building energy efficiency. The numerical model was based on the EnergyPlus, jEPlus, and jEPlus+EA simulation engines. The approach used in this paper has allowed us to reach significant quantitative energy saving by varying the cooling and heating setpoints and scheduling scenarios. It should be stressed that this approach could be applied to several HVAC systems to reduce energy-building consumption.
There is a strong interaction between the urban atmospheric canopy layer and the building energy balance. The urban atmospheric conditions affect the heat transfer through exterior walls, the long-wave heat transfer between the building surfaces and the surroundings, the short-wave solar heat gains, and the heat transport by ventilation. Considering also the internal heat gains and the heat capacity of the building structure, the energy demand for heating and cooling and the indoor thermal environment can be calculated based on the urban microclimatic conditions. According to the building energy concept, the energy demand results in an (anthropogenic) waste heat; this is directly transferred to the urban environment. Furthermore, the indoor temperature is re-coupled via the building envelope to the urban environment and affects indirectly the urban microclimate with a temporally lagged and damped temperature fluctuation. We developed a holistic building model for the combined calculation of indoor climate and energy demand based on an analytic solution of Fourier's equation and implemented this model into the PALM model.
It is considered necessary to implement advanced controllers such as model predictive control (MPC) to utilize the technical flexibility of a building polygeneration system to support the rapidly expanding renewable electricity grid. These can handle multiple inputs and outputs, uncertainties in forecast data, and plant constraints, amongst other features. One of the main issues identified in the literature regarding deploying these controllers is the lack of experimental demonstrations using standard components and communication protocols. In this original work, the economic-MPC-based optimal scheduling of a real-world heat pump-based building energy plant is demonstrated, and its performance is evaluated against two conventional controllers. The demonstration includes the steps to integrate an optimization-based supervisory controller into a typical building automation and control system with off-the-shelf HVAC components and usage of state-of-art algorithms to solve a mixed integer quadratic problem. Technological benefits in terms of fewer constraint violations and a hardware-friendly operation with MPC were identified. Additionally, a strong dependency of the economic benefits on the type of load profile, system design and controller parameters was also identified. Future work for the quantification of these benefits, the application of machine learning algorithms, and the study of forecast deviations is also proposed.
In this article we outline the model development planned within the joint projectModel-based city planningand application in climate change (MOSAIK). The MOSAIK project is funded by the German FederalMinistry of Education and Research (BMBF) within the frameworkUrban Climate Under Change ([UC]2)since 2016. The aim of MOSAIK is to develop a highly-efficient, modern, and high-resolution urban climatemodel that allows to be applied for building-resolving simulations of large cities such as Berlin (Germany).The new urban climate model will be based on the well-established large-eddy simulation code PALM, whichalready has numerous features related to this goal, such as an option for prescribing Cartesian obstacles. Inthis article we will outline those components that will be added or modified in the framework of MOSAIK.Moreover, we will discuss the everlasting issue of acquisition of suitable geographical information as inputdata and the underlying requirements from the model's perspective.
This paper presents a framework for numerical building validation enhancement based on detailed building specifications from in-situ measurements and evidence-based validation assessment undertaken on a detached sustainable lightweight building in a semi-arid climate. The validation process has been undergone in a set of controlled experiments – a free-float period, and steady-state internal temperatures. The validation was conducted for a complete year with a 1-min time step for the hourly indoor temperature and the variable refrigerant flow (VRF) energy consumption. The initial baseline model was improved by three series of validation steps per three different field measurements including thermal transmittance, glazing thermal and optical properties, and airtightness. Then, the accurate and validated model was used for building energy efficiency assessment in 12 regions of Morocco. This study aims to assess the effect of accurate building characteristics values on the numerical model enhancement. The initial CV(RMSE) and NMBE have improved respectively from 14.58 % and −11.23 %–7.85 % and 1.86 % for the indoor temperature. Besides, from 31.17 % to 14.37 %–20.57 % and 9.77 % for energy consumption. The findings demonstrate that the lightweight construction with the use of a variable refrigerant flow system could be energy efficient in the southern regions of Morocco.
The transformation of the building energy sector to a highly efficient, clean, decentralised and intelligent system requires innovative technologies like microscale trigeneration and thermally activated building structures (TABS) to pave the way ahead. The combination of such technologies however presents a scientific and engineering challenge. Scientific challenge in terms of developing optimal thermo-electric load management strategies based on overall energy system analysis and an engineering challenge in terms of implementing these strategies through process planning and control. Initial literature research has pointed out the need for a multiperspective analysis in a real life laboratory environment. To this effect an investigation is proposed wherein an analytical model of a microscale trigeneration system integrated with TABS will be developed and compared with a real life test-rig corresponding to building management systems. Data from the experimental analysis will be used to develop control algorithms using model predictive control for achieving the thermal comfort of occupants in the most energy efficient and grid reactive manner. The scope of this work encompasses adsorption cooling based microscale trigeneration systems and their deployment in residential and light commercial buildings.
Microscale trigeneration systems are highly flexible in their operation and thus offer the technical possibility for peak load shifting in building demand side management. However to harness their potential modern control methods such as model predictive control must be implemented for their optimal scheduling. In literature the need for experimental investigation of microscale trigeneration systems to identify typical characteristics of the components and their interactions has been identified. On a real-life setup control specific information of the components is collected and lessons learnt during commissioning of the equipment is shared. The data is analysed to draw the vital characteristics of the system and it will be used for creating models of the components that can be utilised for optimal control.
Experimental Investigation of the Air Exchange Effectiveness of Push-Pull Ventilation Devices
(2020)
The increasing installation numbers of ventilation units in residential buildings are driven by legal objectives to improve their energy efficiency. The dimensioning of a ventilation system for nearly zero energy buildings is usually based on the air flow rate desired by the clients or requested by technical regulations. However, this does not necessarily lead to a system actually able to renew the air volume of the living space effectively. In recent years decentralised systems with an alternating operation mode and fairly good energy efficiencies entered the market and following question was raised: “Does this operation mode allow an efficient air renewal?” This question can be answered experimentally by performing a tracer gas analysis. In the presented study, a total of 15 preliminary tests are carried out in a climatic chamber representing a single room equipped with two push-pull devices. The tests include summer, winter and isothermal supply air conditions since this parameter variation is missing till now for push-pull devices. Further investigations are dedicated to the effect of thermal convection due to human heat dissipation on the room air flow. In dependence on these boundary conditions, the determined air exchange efficiency varies, lagging behind the expected range 0.5 < εa < 1 in almost all cases, indicating insufficient air exchange including short-circuiting. Local air exchange values suggest inhomogeneous air renewal depending on the distance to the indoor apertures as well as the temperature gradients between in- and outdoor. The tested measurement set-up is applicable for field measurements.
The German Weather Service (DWD) releases a heat warning, when the weather forecast provides a warm, humid, sunny, and windless weather condition during the next days. The heat stress is calculated by the so called Klima-Michel model. If the apparent air temperature exceeds ca. 32°C / 38°C, there is a strong / extreme heat stress. The smallest forecast area is each administrative district. As people (and especially the vulnerable population) stay most of the time indoors, the heat health warning system was extended by the prediction of heat stress in typical rooms. Therewith it is feasible to forecast the heat stress using a combination of the outdoor and indoor heat stress. The prediction for the indoor heat stress is based on the same weather forecast like the Heat Health Warning Systems (HHWS).and calculates the heat stress by the PMV-model (predicted mean vote). Based on a sophisticated data analysis and simulation study, realistic but summer-critical living situations were defined and implemented in the building simulation program ESP-r. As the simulation runs especially for extreme weather conditions, a simplified building model cannot be used. Standardized input/output routines and an adaptive handover of start values provide for short run times for each forecast area. Good building designs and urban planning provide effective measures to reduce heat stress in cities. However, we have to also pay attention to the present building stock under climate change and a higher heat-wave risk. The extended German HHWS provide information for the emergency services to support the social assistants during heat waves.