The German Weather Service (DWD) releases a heat warning, when the weather forecast provides a warm, humid, sunny, and windless weather condition during the next days. The heat stress is calculated by the so called Klima-Michel model. If the apparent air temperature exceeds ca. 32°C / 38°C, there is a strong / extreme heat stress. The smallest forecast area is each administrative district. As people (and especially the vulnerable population) stay most of the time indoors, the heat health warning system was extended by the prediction of heat stress in typical rooms. Therewith it is feasible to forecast the heat stress using a combination of the outdoor and indoor heat stress. The prediction for the indoor heat stress is based on the same weather forecast like the Heat Health Warning Systems (HHWS).and calculates the heat stress by the PMV-model (predicted mean vote). Based on a sophisticated data analysis and simulation study, realistic but summer-critical living situations were defined and implemented in the building simulation program ESP-r. As the simulation runs especially for extreme weather conditions, a simplified building model cannot be used. Standardized input/output routines and an adaptive handover of start values provide for short run times for each forecast area. Good building designs and urban planning provide effective measures to reduce heat stress in cities. However, we have to also pay attention to the present building stock under climate change and a higher heat-wave risk. The extended German HHWS provide information for the emergency services to support the social assistants during heat waves.
This study presents some results from a monitoring project with night ventilation and earthto-air heat exchanger. Both techniques refer to air-based low-energy cooling. As these technologies are limited to specific boundary conditions (e.g. moderate summer climate, low temperatures during night, or low ground temperatures, respectively), water-based low-energy cooling may be preferred in many projects. A comparison of the night-ventilated building with a ground-cooled building shows major differences in both concepts.
Unter dem europäischen Programm Intelligent Energy for Europe (IEE) fanden sich acht europäische Partner zusammen, um im Rahmen des Projektes ThermCo Lüftungs‐ und Kühlenergiekonzepte für Nichtwohngebäude mit niedrigem Energieeinsatz im Hinblick auf die Energieeffizienz und den thermischen Raumkomfort zu bewerten. Die Analyse erfolgte auf Basis von detaillierten Langzeitmessungen über ein Betriebsjahr in acht Demonstrationsgebäuden in unterschiedlichen klimatischen Zonen Europas und einer standardisierten Datenauswertung. Im Quervergleich aller acht Gebäude werden die Kühlkonzepte gleichermaßen nach dem thermischen Kühlenergiebezug, dem thermischen Raumkomfort und dem Primärenergieeinsatz für die technische Gebäudeausrüstung und die Beleuchtung bewertet. Ein Energiekonzept ist erst dann zufriedenstellend, wenn mit möglichst geringem Energieeinsatz und bei hoher Anlageneffizienz ein guter thermischer Raumkomfort zur Verfügung gestellt werden kann. Mit entsprechenden Gebäudesignaturen werden diese Parameter in einen Zusammenhang gebracht und die Zielstellung überprüft. Detaillierte Komfortuntersuchungen nach der europäischen Komfortnorm DIN EN 15251:2007‐08 geben Hinweise auf die Wirksamkeit der eingesetzten Kühltechnologien in den jeweiligen Klimazonen. Daraus lassen sich Handlungsempfehlungen ableiten.
Buildings that are cooled and, if applicable, heated by thermo-active building systems (TABS) in combination with environmental energy have been established in the market during the last years. Many successful and efficient examples prove, that these systems can achieve a good thermal room comfort with a high energy efficiency of the plant system using environmental energy (mainly surface-near geothermal energy). However, operating experience and a systematic evaluation of several building projects demonstrate that there is potential improvement in the design, implementation, and operation of TABS systems. The article presents operating experience and a detailed evaluation of the operation performance of several non-residential buildings with thermo-active building systems with respect to thermal comfort and energy efficiency.
Energy consumption for cooling is growing dramatically. In the last years, electricity peak consumption grew significantly, switching from winter to summer in many EU countries. This is endangering the stability of electricity grids. This article outlines a comprehensive analysis of an office building performances in terms of energy consumption and thermal comfort (in accordance with static – ISO 7730:2005 – and adaptive thermal comfort criteria – EN 15251:2007 –) related to different cooling concepts in six different European climate zones. The work is based on a series of dynamic simulations carried out in the Trnsys 17 environment for a typical office building. The simulation study was accomplished for five cooling technologies: natural ventilation (NV), mechanical night ventilation (MV), fan-coils (FC), suspended ceiling panels (SCP), and concrete core conditioning (CCC) applied in Stockholm, Hamburg, Stuttgart, Milan, Rome, and Palermo. Under this premise, the authors propose a methodology for the evaluation of the cooling concepts taking into account both, thermal comfort and energy consumption.
Mit längerfristigen Nutzerbefragungen in zwei unmittelbar benachbarten Bürogebäuden in Freiburg wurden das Temperaturempfinden der Nutzer und deren Zufriedenheit mit dem thermischen Raumkomfort zweimal täglich erfasst. Ein Bürogebäude wird im Sommer mit einem maschinellen Nachtlüftungskonzept konditioniert und das zweite verfügt über eine Betonkerntemperierung und eine Zu‐ und Abluftanlage. Auf Basis der vorhandenen Daten aus der Erhebung wurde mit Hilfe von Regressionsanalysen ein Modell zur Vorhersage der Komforttemperatur berechnet und mit den Modellen in DIN EN 15251 verglichen.
Unter dem europäischen Programm Intelligent Energy for Europe (IEE) fanden sich acht europäische Partner zusammen, um im Rahmen des Projektes ThermCo Lüftungs‐ und Kühlenergiekonzepte für Nichtwohngebäude mit niedrigem Energieeinsatz im Hinblick auf die Energieeffizienz und den thermischen Raumkomfort zu bewerten (siehe Teil 1 dieser Veröffentlichung in Bauphysik 34 (2012), Heft 6. Mit Hilfe einer Simulationsstudie für ein typisches Bürogebäude wird das Potenzial unterschiedlicher Lüftungs‐ und Kühlstrategien unter Berücksichtigung von Energieeffizienz und Raumkomfort für verschiedene europäische Klimazonen bewertet. Die Ergebnisse weisen eine hohe Wirksamkeit von Nachtlüftungskonzepten im nord‐europäischen Sommerklima mit verhältnismäßig niedrigen Außentemperaturen nach. Im mitteleuropäischen Sommerklima bietet das Erdreich ein ausreichend niedriges Temperaturniveau für den effizienten Einsatz von wassergeführten Flächentemperiersystemen. Im südeuropäischen Sommerklima kann eine aktive Kühlung über Luft die hohen und schnell fluktuierenden Kühllasten effizient abführen.
Mit längerfristigen Nutzerbefragungen in zwei unmittelbar benachbarten Bürogebäuden in Freiburg wurden das Temperaturempfinden der Nutzer und deren Zufriedenheit mit dem thermischen Raumkomfort zweimal täglich erfasst. Ein Bürogebäude wird im Sommer mit einem maschinellen Nachtlüftungskonzept konditioniert und das zweite verfügt über eine Betonkerntemperierung und eine Zu- und Abluftanlage. Auf Basis der vorhandenen Daten aus der Erhebung wurde mit Hilfe von Regressionsanalysen ein Modell zur Vorhersage der Komforttemperatur berechnet und mit den Modellen in DIN EN 15251 verglichen.