Refine
Year of publication
Document Type
Conference Type
- Konferenz-Abstract (22) (remove)
Language
- German (22) (remove)
Has Fulltext
- no (22)
Is part of the Bibliography
- yes (22) (remove)
Keywords
- Herzrhythmusmodell (2)
- Synchronisierung (2)
- Vorhofflimmern (2)
- Abwasser (1)
- Bioelektrochemische Brennstoffzelle (1)
- Business Intelligence (1)
- Dimensional Modelling (1)
- E-Learning (1)
- Elektrizitätserzeugung (1)
- Herzkrankheit (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (15)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (4)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (2)
- Fakultät Wirtschaft (W) (1)
- IBMS - Institute for Advanced Biomechanics and Motion Studies (ab 16.11.2022) (1)
- POIM - Peter Osypka Institute of Medical Engineering (1)
Open Access
- Open Access (19)
- Bronze (3)
- Closed (2)
- Closed Access (1)
Energetische Aspekte gewinnen bei nachhaltig optimierten Systemen zunehmend an Bedeutung. Klassische Lösungen der Strömungsmechanik sind für viele technische Anwendungen von enormerWichtigkeit. In dieser Arbeit präsentieren wir energetische Analysen zu den unterschiedlichen Rayleigh-Stokes Problemen wie der plötzlich in Gang gesetzten oder gestoppten Platte sowie der periodisch oszillierenden Platte. Die in [1] beschriebenen klassischen Rayleigh-Stokes Probleme sind in vielfältigerWeise für verallgemeinerte Rand- und Anfangsbedingungen untersucht worden. Beispiele hierzu sind in [2, 3] dargestellt. Theoretische Grundlagen zu den folgenden energetischen Betrachtungen sind in [4, 5] enthalten.
The identification and quantification of compounds in the gas phase becomes of increasing interest in the context of environmental protection, as well as in the analytical field. In this respect, the high extinction coefficients of vapours and gases in the ultraviolet wavelength region allow a very sensitive measurement system. In addition, the increased performance of the components necessary for setting up a measurement system, such as fibres, light sources and detectors has been improved. In particular the light sources and detectors offer improved stability, and the deep UV performance and solarisation resistance of fused silica fibres allow have been significantly optimized in the past years. Therefore a compact and reliable detection system with high measuring accuracy is developed. Within this paper possible applications of the system under development and recent results will be discussed.
Vergleich der hämodynamischen Reaktion auf VV-Delay Änderungen bei Sinusrhythmus und Vorhofflimmern
(2010)
About 20% of those heart failure patients receiving cardiac resynchronization therapy (CRT) are in atrial fibrillation (AF). Current guidelines apply for patients in sinus rhythm only. Recent studies have shown again, that successful resynchronization is closely linked to a pre-existent ventricular desynchronization. In those studies, the interventricular conduction delay (IVCD) was determined prior to device implantation by ultrasound in patients with sinus rhythm (SR)only. In patients with AF this method ́s use is limited.
To implement left-heart electrogram (LHE) into standard programmers and to simplify IVCD measurement in heart failure patients with AF, LHE was recorded in 11 AF patients with heart failure by Biotronik ICS3000 programmer via a15Hz Butterworth high-pass filter. Therefore, TOslim esophageal electrode (Dr. Osypka GmbH, Rheinfelden, Germany) was perorally applied and fixed in position of maximal left ventricular defection. IVCD was measured between onset of QRS in surface ECG and left ventricular defection (LV) in LHE. In addition, intra-left ventricular conduction delay (ILVCD) was measured as duration of LV in LHE.
In all of the 11 AF patients, desynchronization was quantifiable by LHE. Mean QRS of 162 ± 27ms (120-206ms) was linked with IVCD of 62ms ± 27ms (37-98ms) and ILVCD of 110 ± 20ms (80-144ms), at mean. Correlation between IVCD and QRS was 0.39 (n. s.) with IVCD/QRS ratio of 0.38 ± 0.11 (0.22-0.81).
A 15Hz high-pass filtered LHE feature of the Biotronik ICS3000 programmer is feasible to quantify ventricular dyssynchrony in heart failure patients with AF in order to clearly indicate implantation of CRT systems. As relations between QRS duration, IVCD and ILVCD considerably differ interindividually, the predictive values of IVCD, ILVCD and IVCD/QRS ratio for individual CRT response or non-response shall be identified in follow-up studies.
Das Ausmaß der elektrischen ventrikulären Desynchronisation bei reduzierter linksventrikulärer Funktion ist von Bedeutung für den Erfolg der Resynchronisationstherapie der Herzinsuffizienz mit biventrikulärer Stimulation. Das Ziel der Untersuchung besteht in der nichtinvasiven Messung der elektrischen inter-ventrikulären Desynchronisation mit und ohne ischämische Herzerkrankung bei kardialen Resynchronisationstherapie Respondern. Bei Patienten mit 25,3 ± 7,3 % reduzierter linksventrikulärer Ejektionsfraktion und 166,9 ± 38,5 ms QRS-Dauer wurde das transösophageale linksventrikuläre EKG abgeleitet. Die QRS-Dauer korrelierte mit dem interventrikulären und links-ventrikulären Delay bei Resynchronisationstherapie Respondern mit nicht-ischämischer Herzerkrankung.
Transösophageales interventrikuläres Delay bei Vorhofflimmern und kardialer Resynchronisation
(2013)
Die transösophageale linksventrikuläre Elektrokardiographie ermöglicht die Evaluierung der elektrischen ventrikulären Desynchronisation im Rahmen der kardialen Resynchronisationstherapie der Herzinsuffizienz. Das Ziel der Untersuchung besteht in der präoperativen Abschätzung des transösophagealen interventrikulären Delays bei Vorhofflimmern und kardialer Resynchronisationstherapie. Bei Patienten mit Vorhofflimmern, Herzinsuffizienz New York Heart Association Klasse 3,0 ± 0,2 und QRS-Dauer 159,6 ± 23,9 ms wurde das fokusierte transösophageale linksventrikuläre EKG abgeleitet. Die kardiale Resynchronisationstherapie Responder QRS-Dauer korrelierte mit dem transösophagealen interventrikulären Delay bei Vorhofflimmern.