Keywords
- injury (11)
- running (9)
- biomechanics (8)
- Biomechanik (7)
- ACL (4)
- COVID-19 (3)
- footwear (3)
- injury prevention (3)
- sport (3)
- Advanced Footwear Technology (2)
Institute
Open Access
- Open Access (44)
- Bronze (19)
- Closed (14)
- Gold (8)
- Closed Access (6)
- Hybrid (6)
- Diamond (4)
Activities for rehabilitation and prevention are often lengthy and associated with pain and frustration. Their playful enrichment (hereafter: gamification) can counteract this, resulting in so-called “exergames”. However, in contrast to games designed solely for entertainment, the increased motivation and immersion in gamified training can lead to a reduced perception of pain and thus to health deterioration. Therefore, it is necessary to monitor activities continuously. However, only an AI-based system able to generate autonomous interventions could vacate the therapists’ costly time and allow better training at home. An automated adjustment of the movement training’s difficulty as well as individualized goal setting and control are essential to achieve such autonomy. This article’s contribution is two-fold: (1) We portray the potentials of gamification in the health area. (2) We present a framework for smart rehabilitation and prevention training allowing autonomous, dynamic, and gamified interactions.
Treadmills are essential to the study of human and animal locomotion as well as for applied diagnostics in both sports and medicine. The quantification of relevant biomechanical and physiological variables requires a precise regulation of treadmill belt velocity (TBV). Here, we present a novel method for time-efficient tracking of TBV using standard 3D motion capture technology. Further, we analyzed TBV fluctuations of four different treadmills as seven participants walked and ran at target speeds ranging from 1.0 to 4.5 m/s. Using the novel method, we show that TBV regulation differs between treadmill types, and that certain features of TBV regulation are affected by the subjects’ body mass and their locomotion speed. With higher body mass, the TBV reductions in the braking phase of stance became higher, even though this relationship differed between locomotion speeds and treadmill type (significant body mass × speed × treadmill type interaction). Average belt speeds varied between about 98 and 103% of the target speed. For three of the four treadmills, TBV reduction during the stance phase of running was more intense (> 5% target speed) and occurred earlier (before 50% of stance phase) unlike the typical overground center of mass velocity patterns reported in the literature. Overall, the results of this study emphasize the importance of monitoring TBV during locomotor research and applied diagnostics. We provide a novel method that is freely accessible on Matlab’s file exchange server (“getBeltVelocity.m”) allowing TBV tracking to become standard practice in locomotion research.
Quantifying the midsole material characteristics of athletic footwear is a standard task in footwear research and development. Current material testing protocols primarily focus on the determination of cushioning properties of the heel region or the quantification of the midsole properties as one assembly. However, midsoles possess different spatial material properties that have not been quantified from previous methodologies. Therefore, new material testing methods are required to quantify the local material response of athletic footwear. We developed a cyclical force-controlled material testing protocol for the determination of non-homogeneously distributed material stiffness with a high spatial resolution. In five prototype shoes varying in their stiffness distribution, we found that the material properties can be reliably measured across the midsole. Furthermore, we observed a characteristic non-linear material response regardless of the midsole location. We found that the material stiffness increased with an increase of the applied force and that this effect is further intensified by higher testing cycles. Additionally, the obtained midsole stiffness depends on the geometry of the midsole. We explored different approaches to reduce the measurement time of the testing protocol and found that the number of measurements can be reduced by 70% using 2 D-interpolation procedures. Determining the spatial material properties of midsoles needs to be considered to understand foot-shoe interactions. Furthermore, this measurement protocol can be used for quality control within the footwear and can be adapted for considering the effects of different running styles or speeds on ground force application characteristics.
Uphill training is applied to induce specific overload on the musculoskeletal system to improve sprinting mechanics. This study aimed to identify unique kinematic features of uphill sprinting at different slopes and to suggest practical implications based on comparisons we early stance phase. At take-off, steeper slopes induced significantly more extended joint angles and higher ROMs during the late stance phase. Compared with moderate slopes, more anti-phase coordination patterns were detected at steeper slopes. Thus, uphill sprinting at steeper slopes shares essential kinematic features with the early acceleration phase of level sprinting. Moderate inclinations induce biomechanical adaptations similar to those in the late acceleration phase of level sprinting. Hence, the specific transfer of uphill sprinting to acceleration depends on the slope inclinations.
The aim of this review was to determine whether smartphone applications are reliable and valid to measure range of motion (RoM) in lower extremity joints. A literature search was performed up to October 2020 in the databases PubMed and Cochrane Library. Studies that reported reliability or validity of smartphone applications for RoM measurements were included. The study quality was assessed with the QUADAS-2 tool and baseline information, validity and reliability were extracted. Twenty-five studies were included in the review. Eighteen studies examined knee RoM, whereof two apps were analysed as having good to excellent reliability and validity for knee flexion (“DrGoniometer”, “Angle”) and one app showed good results for knee extension (“DrGoniometer”). Eight studies analysed ankle RoM. One of these apps showed good intra-rater reliability and excellent validity for dorsiflexion RoM (“iHandy level”), another app showed excellent reliability and moderate validity for plantarflexion RoM (“Coach’s Eye”). All other apps concerning lower extremity RoM had either insufficient results, lacked study quality or were no longer available. Some apps are reliable and valid to measure RoM in the knee and ankle joint. No app can be recommended for hip RoM measurement without restrictions.
Governments have restricted public life during the COVID-19 pandemic, inter alia closing sports facilities and gyms. As regular exercise is essential for health, this study examined the effect of pandemic-related confinements on physical activity (PA) levels. A multinational survey was performed in 14 countries. Times spent in moderate-to-vigorous physical activity (MVPA) as well as in vigorous physical activity only (VPA) were assessed using the Nordic Physical Activity Questionnaire (short form). Data were obtained for leisure and occupational PA pre- and during restrictions. Compliance with PA guidelines was calculated based on the recommendations of the World Health Organization (WHO). In total, n = 13,503 respondents (39 ± 15 years, 59% females) were surveyed. Compared to pre-restrictions, overall self-reported PA declined by 41% (MVPA) and 42.2% (VPA). Reductions were higher for occupational vs. leisure time, young and old vs. middle-aged persons, previously more active vs. less active individuals, but similar between men and women. Compared to pre-pandemic, compliance with WHO guidelines decreased from 80.9% (95% CI: 80.3–81.7) to 62.5% (95% CI: 61.6–63.3). Results suggest PA levels have substantially decreased globally during the COVID-19 pandemic. Key stakeholders should consider strategies to mitigate loss in PA in order to preserve health during the pandemic.
The compliant nature of distal limb muscle-tendon units is traditionally considered suboptimal in explosive movements when positive joint work is required. However, during accelerative running, ankle joint net mechanical work is positive. Therefore, this study aims to investigate how plantar flexor muscle-tendon behavior is modulated during fast accelerations. Eleven female sprinters performed maximum sprint accelerations from starting blocks, while gastrocnemius muscle fascicle lengths were estimated using ultrasonography. We combined motion analysis and ground reaction force measurements to assess lower limb joint kinematics and kinetics, and to estimate gastrocnemius muscle-tendon unit length during the first two acceleration steps. Outcome variables were resampled to the stance phase and averaged across three to five trials. Relevant scalars were extracted and analyzed using one-sample and two-sample t-tests, and vector trajectories were compared using statistical parametric mapping. We found that an uncoupling of muscle fascicle behavior from muscle-tendon unit behavior is effectively used to produce net positive mechanical work at the joint during maximum sprint acceleration. Muscle fascicles shortened throughout the first and second steps, while shortening occurred earlier during the first step, where negative joint work was lower compared with the second step. Elastic strain energy may be stored during dorsiflexion after touchdown since fascicles did not lengthen at the same time to dissipate energy. Thus, net positive work generation is accommodated by the reuse of elastic strain energy along with positive gastrocnemius fascicle work. Our results show a mechanism of how muscles with high in-series compliance can contribute to net positive joint work.
Objective: To identify and evaluate the evidence of the most relevant running-related risk factors (RRRFs) for running-related overuse injuries (ROIs) and to suggest future research directions.
Design: Systematic review considering prospective and retrospective studies. (PROSPERO_ID: 236832)
Data sources: Pubmed. Connected Papers. The search was performed in February 2021.
Eligibility criteria: English language. Studies on participants whose primary sport is running addressing the risk for the seven most common ROIs and at least one kinematic, kinetic (including pressure measurements), or electromyographic RRRF. An RRRF needed to be identified in at least one prospective or two retrospective studies.
Results: Sixty-two articles fulfilled our eligibility criteria. Levels of evidence for specific ROIs ranged from conflicting to moderate evidence. Running populations and methods applied varied considerably between studies. While some RRRFs appeared for several ROIs, most RRRFs were specific for a particular ROI. The biomechanical measurements performed in many studies would have allowed for consideration of many more RRRFs than have been reported, highlighting a potential for more effective data usage in the future.
Conclusion: This study offers a comprehensive overview of RRRFs for the most common ROIs, which might serve as a starting point to develop ROI-specific risk profiles of individual runners. Future work should use macroscopic (big data) approaches involving long-term data collections in the real world and microscopic approaches involving precise stress calculations using recent developments in biomechanical modelling. However, consensus on data collection standards (including the quantification of workload and stress tolerance variables and the reporting of injuries) is warranted.
In diesem Artikel werden die neuesten Entwicklungen in der Forschungsgruppe um Herrn Prof. Dr. Wendt vorgestellt. Es wird der Einsatz des neuen 3-D-Druckers der Firma Neotech, sowie die neuesten Entwicklungen im Leuchtturmprojekt Flitzmo beschrieben. Zudem konnte dieses Jahr mit dem Projekt zum Einsatz von Robotik im Bereich Assisted Living begonnen werden.