Enzyme‐assisted HPTLC method for the simultaneous analysis of inositol phosphates and phosphate
(2023)
Background
The analysis of myo‐inositol phosphates (InsPx) released by phytases during phytic acid degradation is challenging and time‐consuming, particularly in terms of sample preparation, isomer separation, and detection. However, a fast and robust analysis method is crucial when screening for phytases during protein engineering approaches, which result in a large number of samples, to ensure reliable identification of promising novel enzymes or target variants with improved characteristics, for example, pH range, thermal stability, and phosphate release kinetics.
Results
The simultaneous analysis of several InsPx (InsP1‐InsP4 and InsP5 + 6) as well as free phosphate was established on cellulose HPTLC plates using a buffered mobile phase. Inositol phosphates were subsequently stained using a novel enzyme‐assisted staining procedure. Immobilized InsPx were hydrolyzed by a phytase solution of Quantum® Blueliquid 5G followed by a molybdate reagent derivatization. Resulting blue zones were captured by DAD scan. The method shows good repeatability (intra‐day and intra‐lab) with maximum deviations of the Rf value of 0.01. The HPTLC method was applied to three commercially available phytases at two pH levels relevant to the gastrointestinal tract of poultry (pH 5.5 and pH 3.6) to observe their phytate degradation pattern and thus visualize their InsPx fingerprint.
Conclusion
This HPTLC method presents a semi‐high‐throughput analysis for the simultaneous analysis of phytic acid and the resulting lower inositol phosphates after its enzymatic hydrolysis and is also an effective tool to visualize the InsPx fingerprints and possible accumulations of inositol phosphates.
High-performance thin-layer chromatography (HPTLC), as the modern form of TLC (thin-layer chromatography), is suitable for detecting pharmaceutically active compounds over a wide polarity range using the gradient multiple development (GMD) technique. Diode-array detection (DAD) in conjunction with HPTLC can simultaneously acquire ultraviolet‒visible (UV‒VIS) and fluorescence spectra directly from the plate. Visualization as a contour plot helps to identify separated zones. An orange peel extract is used as an example to show how GMD‒DAD‒HPTLC in seven different developments with seven different solvents can provide an overview of the entire sample. More than 50 compounds in the extract can be separated on a 6-cm HPTLC plate. Such separations take place in the biologically inert stationary phase of HPTLC, making it a suitable method for effect-directed analysis (EDA). HPTLC‒EDA can even be performed with living organism, as confirmed by the use of Aliivibrio fischeri bacteria to detect bioluminescence as a measure of toxicity. The combining of gradient multiple development planar chromatography with diode-array detection and effect-directed analysis (GMD‒DAD‒HPTLC‒EDA) in conjunction with specific staining methods and time-of-flight mass spectrometry (TOF‒MS) will be the method of choice to find new chemical structures from plant extracts that can serve as the basic structure for new pharmaceutically active compounds.
Two solvent mixtures for high-performance thin-layer chromatographic (HPTLC) separation of some compounds showing estrogenic activity in the yeast estrogen screen (YES) assay are presented. The new method, planar yeast estrogen screen (pYES) combines the YES assay and a chromatographic separation on silica gel HPTLC plates with the performance of the YES assay. For separation, the analytes were applied bandwise to HPTLC plates (10 × 20 cm) with fluorescent dye (Merck, Germany). The plates were developed in a vertical developing chamber after 30 min of chamber saturation over a separation distance of 70 mm, using cyclohexane‒methyl-ethyl ketone (2:1, V/V) or cyclohexane‒CPME (3:2, V/V) as solvents. Both solvents allow separation of estriol, daidzein, genistein, 17β-estradiol, 17α-ethinyl estradiol, estrone, 4-nonylphenol and bis(2-ethylhexyl) phthalate.
We present a densitometric quantification method for triclosan in toothpaste, separated by high-performance thin-layer chromatography (HPTLC) and using a 48-bit flatbed scanner as the detection system. The sample was band-wise applied to HPTLC plates (10 × 20 cm), with fluorescent dye, Merck, Germany (1.05554). The plates were developed in a vertical developing chamber with 20 min of chamber saturation over 70 mm, using n-heptane–methyl tert-butyl ether–acetic acid (92:8:0.1, V/V) as solvent. The RF value of triclosan is hRF = 22.4, and quantification is based on direct measurements using an inexpensive 48-bit flatbed scanner for color measurements (in red, green, and blue) after plate staining with 2,6-dichloroquinone-4-chloroimide (Gibbs' reagent). Evaluation of the red channel makes the measurements of triclosan very specific. For linearization, an extended Kubelka–Munk expression was used for data transformation. The range of linearity covers more than two orders of magnitude and is between 91 and 1000 ng. The separation method is inexpensive, fast and reliable.
HPTLC on amino plates, with simple heating of the plates for derivatization, has been used for quantification of glucosamine in nutritional supplements. On heating the plate glucosamine reacts to form a compound which strongly absorbs light between 305 and 330 nm, with weak fluorescence. The reaction product can be detected sensitively either by absorption of light or by fluorescence detection. The detection limit in absorption mode is approximately 25 ng per spot. In fluorescence mode a detection limit of 15 ng is achievable. A calibration plot for absorption detection is linear in the range 25 to 4000 ng glucosamine. The derivative formed from glucosamine by heating is stable for months, and the relative standard deviation is 1.64% for 600 ng glucosamine. The amounts of glucosamine found in nutritional supplements were in agreement with the label declarations.
A Validated Quantification of Sudan Red Dyes in Spicery using TLC and a 16-bit Flatbed Scanner
(2018)
We present a video-densitometric quantification method for Sudan red dyes in spices and spice mixtures, separated by TLC. Application was done band-wise in small dots using a 5 μL glass pipette. For separation, the RP-18 plates (20 × 20 cm with fluorescent dye; Merck, Germany, 1.05559) were developed in a vertical developing chamber without vapor saturation from the starting point to a distance of 70 mm by using acetonitrile, methanol, and aqueous ammonia solution (25%; 8 + 1.8 + 0.2, v/v) as mobile phase. The quantification is based on direct measurements using an inexpensive 16-bit flatbed scanner for color measurements (in red, green, and blue). Evaluation of only the green channel makes the measurements very specific. For linearization, an extended Kubelka-Munk expression for data transformation was used. The range of linearity covers more than two magnitudes and lies between 20 and 500 ng. The extraction from a 2 g sample with acetonitrile, evaporation, and reconstitution to 200 μL with methanol and the band-wise application (7 mm) of a 10 μL sample allows a statistically defined LOD of less than 500 ppb of Sudan red dyes. To perform the analysis, a separation chamber, RP-18 plates, 5 μL glass pipettes, and a 16-bit flatbed scanner for 105 € are needed; therefore, the separation method is inexpensive, fast, and reliable.